Watershed Modeling with Remotely Sensed Big Data: MODIS Leaf Area Index Improves Hydrology and Water Quality Predictions

Traditional watershed modeling often overlooks the role of vegetation dynamics. There is also little quantitative evidence to suggest that increased physical realism of vegetation dynamics in process-based models improves hydrology and water quality predictions simultaneously. In this study, we applied a modified Soil and Water Assessment Tool (SWAT) to quantify the extent of improvements that the assimilation of remotely sensed Leaf Area Index (LAI) would convey to streamflow, soil moisture, and nitrate load simulations across a 16,860 km2 agricultural watershedin the midwestern United States. We modified the SWAT source code to automatically override the model’s built-in semiempirical LAI with spatially distributed and temporally continuous estimates from Moderate Resolution Imaging Spectroradiometer (MODIS). Compared to a “basic” traditional model with limited spatial information, our LAI assimilation model (i) significantly improved daily streamflow simulations during medium-to-low flow conditions, (ii) provided realistic spatial distributions of growing season soil moisture, and (iii) substantially reproduced the long-term observed variability of daily nitrate loads. Further analysis revealed that the overestimation or underestimation of LAI imparted a proportional cascading effect on how the model partitions hydrologic fluxes and nutrient pools. As such, assimilation of MODIS LAI data corrected the model’sLAI overestimation tendency, which led to a proportionally increased rootzone soil moisture and decreased plant nitrogen uptake. With these new findings, our study fills the existing knowledge gap regarding vegetation dynamics in watershed modeling and confirms that assimilation of MODIS LAI data in watershed models can effectively improve both hydrology and water quality predictions.

Adnan Rajib↗

An Overall Assessment of JPSS-3 VIIRS Radiometric Performance Based on Pre-Launch Testing

Satellite imagery and data are playing an increasingly important role in scientific studies of the Earth and its climate. The scientific community has been demanding ever-increasing capabilities and accuracy from the data provided by these satellites. One key instrument on board a series of satellite platforms is the Visible Infrared Imaging Radiometer Suite (VIIRS), which provides high-quality data of the Earth from low Earth orbit covering the visible to long-wave infrared parts of the spectrum. The fourth build in the series, set to be launched on the Joint Polar-orbiting Satellite System 3 (JPSS-3) platform, has recently completed its main ground calibration program and is set to be integrated into the satellite bus in the near future. This calibration program covered a comprehensive series of performance metrics designed to demonstrate the quality of the science data and ensure the instrument can maintain its calibration successfully once on-orbit. The subject of this work covers the radiometric calibration metrics including dynamic range, signal-to-noise ratio/noise equivalent differential temperature (SNR/NEdT), polarization sensitivity, scattered light response, relative spectral response, response versus scan angle, and uniformity, as well as uncertainties; all key metrics met or exceeded their design requirements with some minor exceptions. Comparisons to previous builds will also be provided.

JPSS-3↗

The first earth resources technology satellite nearly two years of operation

A brief status report on the performance of the ERTS-1, and an overview of the applications derived from the images are presented. The ERTS-1 spacecraft, sensor and picture processing systems have continued to perform almost flawlessly since August 1972. Registered, multispectral images of all major land masses of the earth, both polar and some oceanic regions are continuously made, covering daily an area of about 5 million square kilometers. The systematic repetition of these observations, which were made over most parts of the world at least once every season, and the high accuracy of thematic mapping that can be obtained from the images, have resulted in many applications that have immense potential benefits for developing countries. Among these applications are the detection and accurate mensuration of surface water; the identification and mensuration of forests, rangeland, crops and soils; the monitoring and mapping of water quality, wildlife habitats and of the effects of land use practices on food and water resources; the assessment of flooding and earthquake hazards; and the facilitation of mineral exploration.

Nordberg, W.↗

Evolution of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) flight and ground data processing system

The modifications made to both the AVIRIS instrument and the data processing facility since the instrument made its initial flight in the summer of 1987 are described. Historical development of the data system is discussed and attention is given to enhancements to instrument stability and noise performance. AVIRIS data facility objectives include rapid and automated decommutation and archiving of data, the ability to assess the quality of the data and health of the instrument, and the provision of an automated procedure for applying radiometric corrections to the data and providing responsive processing of data requests from investigators. The modifications described have resulted in an overall radiometric stability of better than 10 percent, with stability of only a few percent during a single flight.

Porter, Wallace M.↗

Microscopy modality transfer of steel microstructures: Inferring scanning electron micrographs from optical microscopy using generative AI

Scanning electron microscopy (SEM) is resource intensive, which limits its throughput in some applications. As an alternative, we propose applying computer vision and machine learning to generate high-quality synthetic SEM micrographs from micrographs obtained using light optical microscopy (LOM). Working with a correlated LOM/SEM dataset of dual-phase steel images, we test generative models of various architectures, including encoder-decoder networks, generative adversarial networks (GANs), and diffusion-based models. We find that the diffusion models significantly outperform other methods on both qualitative and quantitative assessments, while preserving key metallurgical meaning. This work establishes diffusion as the state-of-the-art for microscopy modality transfer and demonstrates the potential of AI-powered microscopy to enhance LOM with micron scale structural recreation.

Computer vision↗

Smart Ultrasound Remote Guidance Experiment (SURGE) Preliminary Findings

To date, diagnostic quality ultrasound images were obtained aboard the International Space Station (ISS) using the ultrasound of the Human Research Facility (HRF) rack in the Laboratory module. Through the Advanced Diagnostic Ultrasound in Microgravity (ADUM) and the Braslet-M Occlusion Cuffs (BRASLET SDTO) studies, non-expert ultrasound operators aboard the ISS have performed cardiac, thoracic, abdominal, vascular, ocular, and musculoskeletal ultrasound assessments using remote guidance from ground-based ultrasound experts. With exploration class missions to the lunar and Martian surfaces on the horizon, crew medical officers will necessarily need to operate with greater autonomy given communication delays (round trip times of up to 5 seconds for the Moon and 90 minutes for Mars) and longer periods of communication blackouts (due to orbital constraints of communication assets). The SURGE project explored the feasibility and training requirements of having non-expert ultrasound operators perform autonomous ultrasound assessments in a simulated exploration mission outpost. The project aimed to identify experience, training, and human factors requirements for crew medical officers to perform autonomous ultrasonography. All of these aims pertained to the following risks from the NASA Bioastronautics Road Map: 1) Risk 18: Major Illness and Trauna; 2) Risk 20) Ambulatory Care; 3) Risk 22: Medical Informatics, Technologies, and Support Systems; and 4) Risk 23: Medical Skill Training and Maintenance.

Hurst, Victor↗

Evaluation of the MODIS Collection 6 Multilayer Cloud Detection Algorithm Through Comparisons with Cloudsat Cloud Profiling Radar and CALIPSO CALIOP Products

Since multilayer cloud scenes are common in the atmosphere and can be an important source of uncertainty in passive satellite sensor cloud retrievals, the MODIS MOD06 and MYD06 standard cloud optical property products include a multilayer cloud detection algorithm to assist with data quality assessment. This paper presents an evaluation of the Aqua MODIS MYD06 Collection 6 multilayer cloud detection algorithm through comparisons with active Cloud Profiling Radar (CPR) and Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) products that have the ability to provide cloud vertical distributions and directly classify multilayer cloud scenes and layer properties. To compare active sensor products with an imager such as MODIS, it is first necessary to define multilayer clouds in the context of their radiative impact on cloud retrievals. Three main parameters have thus been considered in this evaluation: (1) the maximum separation distance between two cloud layers, (2) the thermodynamic phase of those layers and (3) the upper-layer cloud optical thickness. The impact of including the Pavolonis–Heidinger multilayer cloud detection algorithm, introduced in Collection 6, to assist with multilayer cloud detection has also been assessed. For the year 2008, the MYD06 C6 multilayer cloud detection algorithm identifies roughly 20% of all cloudy pixels as multilayer (decreasing to about 13% if the Pavolonis–Heidinger algorithm output is not used). Evaluation against the merged CPR and CALIOP2B-CLDCLASS-lidar product shows that the MODIS multilayer detection results are quite sensitive to how multilayer clouds are defined in the radar and lidar product and that the algorithm performs better when the optical thickness of the upper cloud layer is greater than about 1.2 with a minimum layer separation distance of 1 km. Finally, we find that filtering the MYD06 cloud optical properties retrievals using the multilayer cloud flag improves aggregated statistics, particularly for ice cloud effective radius.

MODIS↗

A Robust Hybrid Deep Learning Model for Spatiotemporal Image Fusion

Dense time-series remote sensing data with detailed spatial information are highly desired for the monitoring of dynamic earth systems. Due to the sensor tradeoff, most remote sensing systems cannot provide images with both high spatial and temporal resolutions. Spatiotemporal image fusion models provide a feasible solution to generate such a type of satellite imagery, yet existing fusion methods are limited in predicting rapid and/or transient phenological changes. Additionally, a systematic approach to assessing and understanding how varying levels of temporal phenological changes affect fusion results is lacking in spatiotemporal fusion research. The objective of this study is to develop an innovative hybrid deep learning model that can effectively and robustly fuse the satellite imagery of various spatial and temporal resolutions. The proposed model integrates two types of network models: super-resolution convolutional neural network (SRCNN) and long short-term memory (LSTM). SRCNN can enhance the coarse images by restoring degraded spatial details, while LSTM can learn and extract the temporal changing patterns from the time-series images. To systematically assess the effects of varying levels of phenological changes, we identify image phenological transition dates and design three temporal phenological change scenarios representing rapid, moderate, and minimal phenological changes. The hybrid deep learning model, alongside three benchmark fusion models, is assessed in different scenarios of phenological changes. Results indicate the hybrid deep learning model yields significantly better results when rapid or moderate phenological changes are present. It holds great potential in generating high-quality time-series datasets of both high spatial and temporal resolutions, which can further benefit terrestrial system dynamic studies. The innovative approach to understanding phenological changes’ effect will help us better comprehend the strengths and weaknesses of current and future fusion models.

spatiotemporal fusion↗

Review of High‐Speed Digital Image Correlation: Advancements and Good Practices

This paper reviews the current state of the art in high‐speed (HS) and ultrahigh‐speed (UHS) digital image correlation (DIC) techniques, emphasizing their critical role in experimental research across various scientific domains. HS and UHS DIC have evolved significantly, driven by advancements in camera systems, image processing algorithms and experimental methodologies. These developments have opened new avenues for capturing and analysing dynamic events with unprecedented temporal and spatial detail, but not without introducing challenges such as optical distortions, motion blur and lighting issues that can affect measurement quality. This review advocates for standardized reporting practices in HS/UHS DIC methodologies to improve reproducibility and reliability across studies, drawing on guidelines from the International Digital Image Correlation Society (iDICs). Through a comprehensive analysis of over 150 articles, this review identifies key advancements in imaging technology and their application in six research domains: material characterization, test development, fracture mechanics, model validation, ballistic and explosive phenomena assessment and measurement uncertainties. Distinctions between two‐dimensional (2D) and stereo‐DIC applications are explored, offering insights into their practical implementation and trade‐offs. Good practices for HS/UHS DIC applications are proposed along with suggestions for future directions for this evolving field, highlighting the indispensable role of technological innovation in expanding the capabilities of optical metrology.

experimental mechanics↗

Information theoretical assessment of digital imaging systems

The end-to-end performance of image gathering, coding, and restoration as a whole is considered. This approach is based on the pivotal relationship that exists between the spectral information density of the transmitted signal and the restorability of images from this signal. The information-theoretical assessment accounts for (1) the information density and efficiency of the acquired signal as a function of the image-gathering system design and the radiance-field statistics, and (2) the improvement in information efficiency and data compression that can be gained by combining image gathering with coding to reduce the signal redundancy and irrelevancy. It is concluded that images can be restored with better quality and from fewer data as the information efficiency of the data is increased. The restoration correctly explains the image gathering and coding processes and effectively suppresses the image-display degradations.

John, Sarah↗

Spatially resolved optical and near-infrared spectroscopy of the low-metallicity galaxy UGC 4483

UGC 4483 is a dwarf irregular galaxy in the M81 group. Narrow-band imaging has revealed an H II region in UGC 4483 with an H alpha flux approximately = 1 x 10 (exp - 13) ergs/sq cm/s. Optical and near-infrared spectroscopy of this H ll region yields He, N, O, Ne, and S abundances for the interstellar matter (ISM) in this galaxy. The spectra were acquired with several different telescope/instrument combinations in order to assess the quality of the derived uncertainties. With oxygen abundance of 3.3 x 10 (exp -5) (12 + log (O/H) = 7.5), this galaxy is similar to GR 8 and among the most metal poor dwarf irregulars known to date. However, the H II region in UGC 4483 has high excitation and higher surface brightness than GR 8, allowing very accurate abundance estimates. The N/O ratio is 3%, in good agreement with other low-metallicity dwarf galaxies. The S/O abundance ratio in UGC 4483 is close to the solar ratio, consistent with results for I Zw 18 and other low-metallicity dwarf irregulars. A He/H abundance of 0.079 +/- 0.002 is derived from observations of the lambda 6678 He ll emission line. A comparison of observations obtained with different telescopes and with the same telescope on different nights supports our relatively small estimated uncertainty in this measurement. We determine that the neutral helium fraction is insignificant through both direct observations of the He(+)/H(+) ratio across the nebula and through photoionization modeling. This results in a helium mass fraction of 0.239 +/- 0.006, consistent with the most recent theoretical and observational determinations of the primordial helium abundance. We also discuss remaining systematic uncertainties in the calculation of the primordial helium abundance

Skillman, Evan D.↗

Learning instrument invariant characteristics for generating high-resolution global coral reef maps

Coral reefs are one of the most biologically complex and diverse ecosystems within the shallow marine environment. Unfortunately, these underwater ecosystems are threatened by a number of anthropogenic challenges, including ocean acidification and warming, overfishing, and the continued increase of marine debris in oceans. This requires a comprehensive assessment of the world's coastal environments, including a quantitative analysis on the health and extent of coral reefs and other associated marine species, as a vital Earth Science measurement. However, limitations in observational and technological capabilities inhibit global sustained imaging of the marine environment. Harmonizing multimodal data sets acquired using different remote sensing instruments presents additional challenges, thereby limiting the availability of good quality labeled data for analysis. In this work, we develop a deep learning model for extracting domain invariant features from multimodal remote sensing imagery and creating high-resolution global maps of coral reefs by combining various sources of imagery and limited hand-labeled data available for certain regions. This framework allows us to generate, for the first time, coral reef segmentation maps at 2-meter resolution, which is a significant improvement over the kilometer-scale state-of-the-art maps. Additionally, this framework doubles accuracy and IoU metrics over baselines that do not account for domain invariance.

Domain Adaptation↗

Radiometric Accuracy Assessment of LANDSAT-4 Multispectral Scanner (MSS) Data

The LANDSAT-4 mission has unique characteristics relative to previous LANDSAT missions. The spacecraft is new; the orbit is lower with a more frequent repeat cycle; and the ground processing facility consists of new hardware with different algorithms being applied. How some of these changes affect the character of the radiometric data quality is explored. Banding effects; radiometric differences between LANDSAT 3 and 4; and the woodgrain pattern observed visually in the images are considered.

Alford, W. L.↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

Quantitative phase measurements of human cell nuclei using X-ray ptychography

The human cell nucleus serves as an important organelle holding the genetic blueprint for life. In this work, X-ray ptychography was applied to assess the masses of human cell nuclei using its unique phase shift information. Measurements were carried out at the I13-1 beamline at the Diamond Light Source that has extremely large transverse coherence properties. Furthermore, the ptychographic diffractive imaging approach allowed imaging of large structures that gave quantitative measurements of the phase shift in 2D projections. In this paper a modified ptychography algorithm that improves the quality of the reconstruction for weak scattering samples is presented. The application of this approach to calculate the mass of several human nuclei is also demonstrated.

59 BASIC BIOLOGICAL SCIENCES↗

Remote sensing of land use and water quality relationships - Wisconsin shore, Lake Michigan

This investigation assessed the utility of remote sensing techniques in the study of land use-water quality relationships in an east central Wisconsin test area. The following types of aerial imagery were evaluated: high altitude (60,000 ft) color, color infrared, multispectral black and white, and thermal; low altitude (less than 5000 ft) color infrared, multispectral black and white, thermal, and passive microwave. A non-imaging hand-held four-band radiometer was evaluated for utility in providing data on suspended sediment concentrations. Land use analysis includes the development of mapping and quantification methods to obtain baseline data for comparison to water quality variables. Suspended sediment loads in streams, determined from water samples, were related to land use differences and soil types in three major watersheds. A multiple correlation coefficient R of 0.85 was obtained for the relationship between the 0.6-0.7 micrometer incident and reflected radiation data from the hand-held radiometer and concurrent ground measurements of suspended solids in streams. Applications of the methods and baseline data developed in this investigation include: mapping and quantification of land use; input to watershed runoff models; estimation of effects of land use changes on stream sedimentation; and remote sensing of suspended sediment content of streams. High altitude color infrared imagery was found to be the most acceptable remote sensing technique for the mapping and measurement of land use types.

Haugen, R. K.↗

Big Cypress Water Resources: Using Earth Observations to Assess Water Quality in Big Cypress Reservation, FL

Upstream agricultural development and runoff are driving harmful algal blooms in the Big Cypress Reservation. The Seminole Tribe of Florida Environmental Resource Management Department monitors water quality in the Big Cypress Reservation, located on the north end of Big Cypress National Preserve. The Environmental Resource Management Department aims to incorporate Earth observations into its investigative approach, which consists of Geographic Information Systems and in situ water sampling. We assessed the feasibility of using Earth observations to measure harmful algal blooms over time and identify vulnerable areas. We analyzed data from multiple remote sensing platforms and sensors, including Landsat 8 Thermal Infrared Spectrometer(TIRS), Landsat 9 TIRS-2, Landsat 9 Operational Land Imager 2, Sentinel-2 MultiSpectral Instrument, and Sentinel-3 Ocean and Land Color Instrument. We determined that it was challenging to use Sentinel-3, Landsat 8, and Landsat 9 imagery for monitoring the canals within the Reservation, and that Sentinel-2 was the most capable platform for the study area. Using Sentinel-2, we created spectral indices for the detection of algal blooms. We used these indices to measure algal blooms at 8 stations across the Big Cypress Reservation. We then created time series and seasonal decompositions of in situ water sample data and indices to visualize relationships between datasets, along with correlation matrices. Our correlations were not conclusive. However, we found that the spectral indices have the potential to detect algal blooms. Lastly, we evaluated Maxar WorldView-3 imagery and found that using data from sensors with higher spatial resolutions would improve results.

Remote sensing↗

Evaluation of the VIIRS BRDF, Albedo and NBAR Products Suite and an Assessment of Continuity with the Long Term MODIS Record

Bidirectional Reflectance Distribution Function (BRDF) model parameters, Albedo quantities, and Nadir BRDF Adjusted Reflectance (NBAR) products derived from the Visible Infrared Imaging Radiometer Suite (VIIRS), on the Suomi-NPP (National Polar-orbiting Partnership) satellite are evaluated with spatially representative in situ tower albedometer measurements and through comparison with the MODerate Resolution Imaging Spectroradiometer (MODIS) long term record. White Sky Albedo (WSA), Black Sky Albedo (BSA), NBAR, and Quality Assurance (QA) results show that the VIIRS algorithm is performing well at the global scale and is able to provide global data products comparable with the heritage MODIS (with an absolute bias of 0.0069 for shortwave broadband WSA) despite the spectral, angular, and effective spatial resolution differences between the two sensors. Both VIIRS and MODIS albedo are shown to agree well with in situ albedo measurements at a number of spatially representative sites. This evaluation provides confidence that the high quality, daily VIIRS BRDF model parameters, Albedo, and NBAR products will be able to provide the long term continuity required by the modeling and monitoring communities.