Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image plates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Comparison of implosion core metrics: A 10 ps dilation X-ray imager vs a 100 ps gated microchannel plate [Comparison of implosion core shape observations, 10 ps dilation X-ray imager vs 100 ps gated microchannel plate]

The dilation x-ray imager (DIXI) is a high-speed x-ray framing camera that uses the pulse-dilation technique to achieve a temporal resolution of less than 10 ps. This is a 10× improvement over conventional framing cameras currently employed on the National Ignition Facility (NIF) (100 ps resolution), and otherwise only achievable with 1D streaked imaging. A side effect of the dramatically reduced gate width is the comparatively lower detected signal level. Therefore we implement a Poisson noise reduction with non-local principal component analysis method to improve the robustness of the DIXI data analysis. Furthermore, we present results on ignition-relevant experiments at the NIF using DIXI. In particular we focus on establishing that/when DIXI gives reliable shape metrics (P 0 , P 2 and P 4 Legendre modes, and their temporal evolution/swings).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

System and method for underwater radiography

A system for subsea imaging comprises a first plate having an inner surface, an outer surface, and a cavity formed in the inner surface. In addition, the system comprises a phosphor imaging plate disposed in the cavity. Further, the system comprises a second plate having an inner surface facing the inner surface of the first plate and an outer surface facing away from the outer surface of the first plate. Still further, the system comprises a seal member disposed between the inner surface of the first plate and the inner surface of the second plate. The seal member extends around the perimeter of the cavity and is configured to seal the phosphor imaging plate and the cavity from intrusion water.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DISCOVERY OF A SECOND NOVA ERUPTION OF V2487 OPHIUCHI

A directed search for previously undiscovered nova eruptions was conducted in the astronomical plate archives at Harvard College Observatory and Sonneberg Observatory. We found that an eruption of V2487 Oph (Nova Oph 1998) occurred on 1900 June 20. V2487 Oph was previously classified as a classical nova, which we identified as a probable recurrent nova based on its large expansion velocities and the presence of high excitation lines in the outburst spectrum. The event was recorded on Harvard plate AM 505, at a B magnitude of 10.27 {+-} 0.11, which is near the peak. The outburst can only be seen on one plate, but the image has a characteristic dumbbell shape (caused by a double exposure) that is identical to the other star images on the plate, and thus is not a plate defect. We conclude that this is in fact a previously undiscovered nova outburst of V2487 Oph, confirming our prediction that it is a recurrent nova. We also examine the discovery efficiency for eruptions of the system and conclude that a randomly timed outburst has, on average, a 30% chance of being discovered in the past century. Using this, we deduce a recurrence time for V2487 Oph of approximately 18 years, which implies that the next eruption is expected around 2016.

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging of large-area microchannel plates using phosphor screens

A testing system was built, using UV illumination at 254 nm and a cathodoluminescent phosphor screen, to measure the gain uniformity of large area (20 x 20 cm(2)) microchannel plates. The phosphor screen image is captured with a wide-angle CMOS digital camera (4032 x 3024 pixels) and analyzed. First a reference MCP is illuminated and the generated phosphor screen image is captured with a CCD camera. In a second step, another image is captured with the MCP under test inserted between the reference MCP and the phosphor screen. The ratio of the two images is analyzed and provides a quantitative measure of the relative gain uniformity of the MCP under test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FIRST RESULTS FROM VERY LARGE TELESCOPE NACO APODIZING PHASE PLATE: 4 {mu}m IMAGES OF THE EXOPLANET {beta} PICTORIS b

Direct imaging of exoplanets requires both high contrast and high spatial resolution. Here, we present the first scientific results obtained with the newly commissioned apodizing phase plate coronagraph (APP) on VLT/NACO. We detected the exoplanet {beta} Pictoris b in the narrowband filter centered at 4.05 {mu}m (NB4.05). The position angle (209.{sup 0}13 {+-} 2.{sup 0}12) and the projected separation to its host star (0.''354 {+-} 0.''012, i.e., 6.8 {+-} 0.2 AU at a distance of 19.3 pc) are in good agreement with the recently presented data from Lagrange et al. Comparing the observed NB4.05 magnitude of 11.20 {+-} 0.23 mag to theoretical atmospheric models, we find a best fit with a 7-10 M {sub Jupiter} object for an age of 12 Myr, again in agreement with previous estimates. Combining our results with published L' photometry, we can compare the planet's [L' - NB4.05] color to that of cool field dwarfs of higher surface gravity suggesting an effective temperature of {approx}1700 K. The best-fit theoretical model predicts an effective temperature of {approx}1470 K, but this difference is not significant given our photometric uncertainties. Our results demonstrate the potential of NACO/APP for future planet searches and provide independent confirmation as well as complementary data for {beta} Pic b.

79 ASTRONOMY AND ASTROPHYSICS↗

Development and characterization of monolithic multilayer Laue lens nanofocusing optics

We have developed an experimental approach to bond two independent linear Multilayer Laue Lenses (MLLs) together. A monolithic MLL structure was characterized using ptychography at 12 keV photon energy, and we demonstrated 12 nm and 24 nm focusing in horizontal and vertical directions, respectively. Fabrication of 2D MLL optics allows installation of these focusing elements in more conventional microscopes suitable for x-ray imaging using zone plates, and opens easier access to 2D imaging with high spatial resolution in the hard x-ray regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging flaws in thin metal plates using a magneto-optic device

An account is given of the capabilities of the magnetooptic/eddy-current imager (MEI) apparatus in the case of aging aircraft structure-type flaws in 2024-T3 Al alloy plates. Attention is given to images of cyclically grown fatigue cracks from rivetted joints in fabricated lap-joint structures, electrical discharge machining notches, and corrosion spots. Although conventional eddy-current methods could have been used, the speed and ease of MEI's use in these tests is unmatched by such means. Results are displayed in real time as a test piece is scanned, furnishing easily interpreted flaw images.

Wincheski, B.↗

Method of obtaining intensified image from developed photographic films and plates

A method is explained of obtaining intensified images from silver images on developed photographic films and plates. The steps involve converting silver of the developed film or plate to a radioactive compound by treatment with an aqueous alkaline solution of an organo-S35 compound; placing the treated film or plate in direct contact with a receiver film which is then exposed by radiation from the activated film; and developing and fixing the resulting intensified image on the receiver film.

Askins, B. S.↗

Saturation and Dynamic Range of Microchannel Plate-Based X-Ray Imagers

This paper describes recent advances in Monte Carlo simulations of microchannel plate (MCP)–based x-ray detectors, a continuation of ongoing work in this area. A Monte Carlo simulation model has been developed over the past several years by National Security Technologies, LLC (NSTec). The model simulates the secondary electron emission process in an MCP pore and includes the effects of gain saturation. In this work we focus on MCP gain saturation and dynamic range. We have performed modeling and experimental characterizations of L/D = 46, 10-micron diameter, MCP-based detectors. The detectors are typically operated by applying a subnanosecond voltage pulse, which gates the detector on. Agreement between the simulations and experiment is very good for a variety of voltage pulse waveforms ranging in width from 150 to 300 ps. The results indicate that such an MCP begins to show nonlinear gain around 5 × 10^4 electrons per pore and hard saturation around 105 electrons per pore. The simulations show a difference in MCP sensitivity vs voltage for high flux of photons producing large numbers of photoelectrons on a subpicosecond timescale. Simulations and experiments both indicate an MCP dynamic range of 1 to 10,000, and the dynamic range depends on how the voltage is applied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cumulative phase delay imaging - A new contrast enhanced ultrasound modality

Recently, a new acoustic marker for ultrasound contrast agents (UCAs) has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental pressure wave field components is in fact observable for ultrasound propagating through UCAs. This phenomenon is absent in the case of tissue nonlinearity and is dependent on insonating pressure and frequency, UCA concentration, and propagation path length through UCAs. In this paper, ultrasound images based on this marker are presented. The ULA-OP research platform, in combination with a LA332 linear array probe (Esaote, Firenze Italy), were used to image a gelatin phantom containing a PVC plate (used as a reflector) and a cylindrical cavity measuring 7 mm in diameter (placed in between the observation point and the PVC plate). The cavity contained a 240 µL/L SonoVueO{sup ®} UCA concentration. Two insonating frequencies (3 MHz and 2.5 MHz) were used to scan the gelatine phantom. A mechanical index MI = 0.07, measured in water at the cavity location with a HGL-0400 hydrophone (Onda, Sunnyvale, CA), was utilized. Processing the ultrasound signals backscattered from the plate, ultrasound images were generated in a tomographic fashion using the filtered back-projection method. As already observed in previous studies, significantly higher CPD values are measured when imaging at a frequency of 2.5 MHz, as compared to imaging at 3 MHz. In conclusion, these results confirm the applicability of the discussed CPD as a marker for contrast imaging. Comparison with standard contrast-enhanced ultrasound imaging modalities will be the focus of future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Meteor44 Video Meteor Photometry

Meteor44 is a software system developed at MSFC for the calibration and analysis of video meteor data. The dynamic range of the (8bit) video data is extended by approximately 4 magnitudes for both meteors and stellar images using saturation compensation. Camera and lens specific saturation compensation coefficients are derived from artificial variable star laboratory measurements. Saturation compensation significantly increases the number of meteors with measured intensity and improves the estimation of meteoroid mass distribution. Astrometry is automated to determine each image's plate coefficient using appropriate star catalogs. The images are simultaneously intensity calibrated from the contained stars to determine the photon sensitivity and the saturation level referenced above the atmosphere. The camera s spectral response is used to compensate for stellar color index and typical meteor spectra in order to report meteor light curves in traditional visual magnitude units. Recent efforts include improved camera calibration procedures, long focal length 'streak' meteor photometry and two-station track determination. Meteor44 has been used to analyze data from the 2001, 2002 and 2003 MSFC Leonid observational campaigns as well as several lesser showers. The software is interactive and can be demonstrated using data from recent Leonid campaigns.

Swift, Wesley R.↗

Meteor44 Video Meteor Photometry

Meteor44 is a software system developed at MSFC for the calibration and analysis of video meteor data. The dynamic range of the (8bit) video data is extended by approximately 4 magnitudes for both meteors and stellar images using saturation compensation. Camera and lens specific saturation compensation coefficients are derived from artificial variable star laboratory measurements. Saturation compensation significantly increases the number of meteors with measured intensity and improves the estimation of meteoroid mass distribution. Astrometry is automated to determine each image s plate coefficient using appropriate star catalogs. The images are simultaneously intensity calibrated from the contained stars to determine the photon sensitivity and the saturation level referenced above the atmosphere. The camera s spectral response is used to compensate for stellar color index and typical meteor spectra in order to report meteor light curves in traditional visual magnitude units. Recent efforts include improved camera calibration procedures, long focal length "streak" meteor photome&y and two-station track determination. Meteor44 has been used to analyze data from the 2001.2002 and 2003 MSFC Leonid observational campaigns as well as several lesser showers. The software is interactive and can be demonstrated using data from recent Leonid campaigns.

Swift, Wesley R.↗

Microchannel plate EUV detectors for the Extreme Ultraviolet Explorer

The design and operating characteristics of the prototype imaging microchannel plate (MCP) detector for the Extreme Ultraviolet Explorer (EUVE) Satellite are discussed. It is shown that this detector has achieved high position resolution performance (greater than 512 x 512 pixels) and has low (less than one percent) image distortion. In addition, the channel plate scheme used has tight pulse height distributions (less than 40 percent FWHM) for UV radiation and displays low (less than 0.2 cnt/sq cm-s) dark background counting rates. Work that has been done on EUV filters in relation to the envisaged filter and photocathode complement is also described.

Siegmund, O. H. W.↗

Zone plate-based extreme ultraviolet mask microscope with through-pellicle imaging capability

Mirror-based and zone plate-based imaging systems are being used in actinic extreme ultraviolet (EUV) reticle review tools. With regard to zone plates, a short working distance is advantageous in terms of the required spectral bandwidth, manufacturability, and potential throughput and imaging performance. Zone plates therefore typically have a short working distance. The industry has adopted the use of an EUV pellicle to protect the photomask. Imaging photomask through-pellicle requires a working distance larger than 2.5 mm. A zone-plate-based EUV mask microscope with a 3-mm working distance has been commissioned at beamline 11.3.2 of the Advanced Light Source. Through-pellicle imaging at an exposure time of 2 s is demonstrated. The instrument achieves an image contrast of 95% on large features on a photomask with a tantalum-based absorber. Imaging down to 45-nm half pitch (mask scale) is demonstrated. A NILS of 2.55 is achieved on 60-nm half-pitch (mask scale) lines and spaces. These results demonstrate that zone-plate-based imaging systems can meet the requirements of an actinic EUV mask review tool in terms of imaging performance and throughput in an instrument compatible with EUV pellicles.

Extreme ultraviolet↗

A multi-plate velocity-map imaging design for high-resolution photoelectron spectroscopy

A velocity map imaging (VMI) setup consisting of multiple electrodes with three adjustable voltage parameters, designed for slow electron velocity map imaging applications, is presented. The motivations for this design are discussed in terms of parameters that influence the VMI resolution and functionality. Particularly, this VMI has two tunable potentials used to adjust for optimal focus, yielding good VMI focus across a relatively large energy range. It also allows for larger interaction volumes without significant sacrifice to the resolution via a smaller electric gradient at the interaction region. All the electrodes in this VMI have the same dimensions for practicality and flexibility, allowing for relatively easy modifications to suit different experimental needs. We have coupled this VMI to a cryogenic ion trap mass spectrometer that has a flexible source design. The performance is demonstrated with the photoelectron spectra of S- and CS 2 - . The latter has a long vibrational progression in the ground state, and the temperature dependence of the vibronic features is probed by changing the temperature of the ion trap.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Damage imaging in a laminated composite plate using an air-coupled time reversal mirror

We demonstrate the possibility of selectively imaging the features of a barely visible impact damage in a laminated composite plate by using an air-coupled time reversal mirror. The mirror consists of a number of piezoelectric transducers affixed to wedges of power law profiles, which act as unconventional matching layers. The transducers are enclosed in a hollow reverberant cavity with an opening to allow progressive emission of the ultrasonic wave field towards the composite plate. The principle of time reversal is used to focus elastic waves at each point of a scanning grid spanning the surface of the plate, thus allowing localized inspection at each of these points. The proposed device and signal processing removes the need to be in direct contact with the plate and reveals the same features as vibrothermography and more features than a C-scan. More importantly, this device can decouple the features of the defect according to their orientation, by selectively focusing vector components of motion into the object, through air. For instance, a delamination can be imaged in one experiment using out-of-plane focusing, whereas a crack can be imaged in a separate experiment using in-plane focusing. As a result, this capability, inherited from the principle of time reversal, cannot be found in conventional air-coupled transducers.

36 MATERIALS SCIENCE↗