Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high throughput”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Protein Crystal Growth With the Aid of Microfluidics

Protein crystallography is one of three well-known methods to obtain the structure of proteins. A major rate limiting step in protein crystallography is protein crystal nucleation and growth, which is still largely a process conducted by trial-and-error methods. Many attempts have been made to improve protein crystal growth by performing growth in microgravity. Although the use of microgravity appears to improve crystal quality in some attempts, this method has been inefficient because several reasons: we lack a fundamental understanding of macromolecular crystal growth in general and of the influence of microgravity in particular, we have to start with crystal growth conditions in microgravity based on conditions on the ground and finally the hardware does not allow for experimental iteration without reloading samples on the ground. To partially accommodate the disadvantages of the current hardware, we have used microfluidic technology (Lab-on-a-Chip devices) to design the concept of a more efficient crystallization device, suitable for use on the International Space Station and in high-throughput applications on the ground. The concept and properties of microfluidics, the application design process, and the advances in protein crystal growth hardware will be discussed in this presentation. Some examples of proteins crystallized in the new hardware will be discussed, including the differences between conventional crystallization versus crystallization in microfluidics.

vanderWoerd, Mark↗

Monolithic Hydrogen Peroxide Catalyst Bed Development

With recent increased industry and government interest in rocket grade hydrogen peroxide as a viable propellant, significant effort has been expended to improve on earlier developments. This effort has been predominately centered in improving heterogeneous. typically catalyst beds; and homogeneous catalysts, which are typically solutions of catalytic substances. Heterogeneous catalyst beds have traditionally consisted of compressed wire screens plated with a catalytic substance, usually silver, and were used m many RCS applications (X-1, Mercury, and Centaur for example). Aerojet has devised a heterogeneous catalyst design that is monolithic (single piece), extremely compact, and has pressure drops equal to or less than traditional screen beds. The design consists of a bonded stack of very thin, photoetched metal plates, silver coated. This design leads to a high surface area per unit volume and precise flow area, resulting in high, stable, and repeatable performance. Very high throughputs have been demonstrated with 90% hydrogen peroxide. (0.60 lbm/s/sq in at 1775-175 psia) with no flooding of the catalyst bed. Bed life of over 900 seconds has also been demonstrated at throughputs of 0.60 lbm/s/sq in across varying chamber pressures. The monolithic design also exhibits good starting performance, short break-in periods, and will easily scale to various sizes.

Ponzo, J. B.↗

NETMARK: A Schema-less Extension for Relational Databases for Managing Semi-structured Data Dynamically

Object-Relational database management system is an integrated hybrid cooperative approach to combine the best practices of both the relational model utilizing SQL queries and the object-oriented, semantic paradigm for supporting complex data creation. In this paper, a highly scalable, information on demand database framework, called NETMARK, is introduced. NETMARK takes advantages of the Oracle 8i object-relational database using physical addresses data types for very efficient keyword search of records spanning across both context and content. NETMARK was originally developed in early 2000 as a research and development prototype to solve the vast amounts of unstructured and semi-structured documents existing within NASA enterprises. Today, NETMARK is a flexible, high-throughput open database framework for managing, storing, and searching unstructured or semi-structured arbitrary hierarchal models, such as XML and HTML.

Maluf, David A.↗

WaFIRS, a Waveguide Far-IR Spectrometer: Enabling Space-Borne Spectroscopy of High-z Galaxies in the Far-IR and Submm

The discovery of galaxies beyond z approximately equal to 1 which emit the bulk of their luminosity at long wavelengths has demonstrated the need for high sensitivity, broadband spectroscopy in the far-IR/submm/mm bands. Because many of these sources are not detectable in the optical, long wavelength spectroscopy is key to measuring their redshifts and ISM conditions. The continuum source list will increase in the next decade with new ground-based instruments (SCUBA2, Bolocam, MAMBO) and the surveys of HSO and SIRTF. Yet the planned spectroscopic capabilities lag behind, primarily due to the difficulty in scaling existing IR spectrograph designs to longer wavelengths. To overcome these limitations, we are developing WaFIRS, a novel concept for long-wavelength spectroscopy which utilizes a parallel-plate waveguide and a curved diffraction grating. WaFIRS provides the large (approximately 60%) instantaneous bandwidth and high throughput of a conventional grating system, but offers a dramatic reduction in volume and mass. WaFIRS requires no space overheads for extra optical elements beyond the diffraction grating itself, and is two-dimensional because the propagation is confined between two parallel plates. Thus several modules could be stacked to multiplex either spatially or in different frequency bands. The size and mass savings provide opportunities for spectroscopy from space-borne observatories which would be impractical with conventional spectrographs. With background-limited detectors and a cooled 3.5 telescope, the line sensitivity would be better than that of ALMA, with instantaneous broad-band coverage. We have built and tested a WaFIRS prototype for 1-1.6 mm, and are currently constructing Z-Spec, a 100 mK model to be used as a ground-based lambda/DELTAlambda approximately equal to 350 submillimeter galaxy redshift machine.

Bradford, C. M.↗

Fidelity and enhanced sensitivity of differential transcription profiles following linear amplification of nanogram amounts of endothelial mRNA

Although mRNA amplification is necessary for microarray analyses from limited amounts of cells and tissues, the accuracy of transcription profiles following amplification has not been well characterized. We tested the fidelity of differential gene expression following linear amplification by T7-mediated transcription in a well-established in vitro model of cytokine [tumor necrosis factor alpha (TNFalpha)]-stimulated human endothelial cells using filter arrays of 13,824 human cDNAs. Transcriptional profiles generated from amplified antisense RNA (aRNA) (from 100 ng total RNA, approximately 1 ng mRNA) were compared with profiles generated from unamplified RNA originating from the same homogeneous pool. Amplification accurately identified TNFalpha-induced differential expression in 94% of the genes detected using unamplified samples. Furthermore, an additional 1,150 genes were identified as putatively differentially expressed using amplified RNA which remained undetected using unamplified RNA. Of genes sampled from this set, 67% were validated by quantitative real-time PCR as truly differentially expressed. Thus, in addition to demonstrating fidelity in gene expression relative to unamplified samples, linear amplification results in improved sensitivity of detection and enhances the discovery potential of high-throughput screening by microarrays.

Evaluation Studies↗

Digital echocardiography 2002: now is the time

The ability to acquire echocardiographic images digitally, store and transfer these data using the DICOM standard, and routinely analyze examinations exists today and allows the implementation of a digital echocardiography laboratory. The purpose of this review article is to outline the critical components of a digital echocardiography laboratory, discuss general strategies for implementation, and put forth some of the pitfalls that we have encountered in our own implementation. The major components of the digital laboratory include (1) digital echocardiography machines with network output, (2) a switched high-speed network, (3) a high throughput server with abundant local storage, (4) a reliable low-cost archive, (5) software to manage information, and (6) support mechanisms for software and hardware. Implementation strategies can vary from a complete vendor solution providing all components (hardware, software, support), to a strategy similar to our own where standard computer and networking hardware are used with specialized software for management of image and measurement information.

Review↗

The Constellation-X Spectroscopy X-Ray Telescope

The status of technology development for the Constellation-X Spectroscopy X-ray Telescope (SXT) mirror is presented. The SXT mirror combines a large (1.6 m) aperture with modest (12 arc sec half power diameter) angular resolution and low mass (750 kg). The overall collecting area, larger than 9,600 square cm at 0.25 keV, requires high throughput, and thus nesting of a substantial number of thin reflectors. A phased development program is underway to develop reflectors, mounting and alignment approaches, and metrology techniques for components and the mirror has a whole. The latest results in all these areas are summarized, along with an overview of results of optical testing of reflector performance.

Petre, Robert↗

Replicated Nickel Optics for the Hard-X-Ray Region

Replicated nickel optics has been used extensively in x-ray astronomy, most notable for the XMM/Newton mission. Thc combination of relative ease of fabrication and the inherent stability of full shell optics, make them FIJI attractive approach for medium-resolution, high-throughput applications. MSFC has been developing these optics for use in the hard-x-ray region. Efforts at improving the resolution of these, particularly the very-thin shells required to meet thc weight budget of future missions, will be described together with the prospects for significant improvements down to the 5-arcsec level.

Ramsey, Brian↗

VLSI design of turbo decoder for integrated communication system on a chip applications

A high-throughput low-power turbo decoder core has been developed for integrated communication system applications such as satellite communications, wireless LAN, digital TV, cable modem, Digital Video Broadcast (DVB), and xDSL systems. The turbo decoder is based on convolutional constituent codes, which outperform all other Forward Error Correction techniques. This turbo decoder core is parameterizable and can be modified easily to fit any size for advanced communication system-on-chip products. The turbo decoder core provides Forward Error Correction of up to 15 Mbits/sec on a 0.13-micron CMOS FPGA prototyping chip at a power of 0.1 watts.

turbo decoder↗

Searching Across the International Space Station Databases

Data access in the enterprise generally requires us to combine data from different sources and different formats. It is advantageous thus to focus on the intersection of the knowledge across sources and domains; keeping irrelevant knowledge around only serves to make the integration more unwieldy and more complicated than necessary. A context search over multiple domain is proposed in this paper to use context sensitive queries to support disciplined manipulation of domain knowledge resources. The objective of a context search is to provide the capability for interrogating many domain knowledge resources, which are largely semantically disjoint. The search supports formally the tasks of selecting, combining, extending, specializing, and modifying components from a diverse set of domains. This paper demonstrates a new paradigm in composition of information for enterprise applications. In particular, it discusses an approach to achieving data integration across multiple sources, in a manner that does not require heavy investment in database and middleware maintenance. This lean approach to integration leads to cost-effectiveness and scalability of data integration with an underlying schemaless object-relational database management system. This highly scalable, information on demand system framework, called NX-Search, which is an implementation of an information system built on NETMARK. NETMARK is a flexible, high-throughput open database integration framework for managing, storing, and searching unstructured or semi-structured arbitrary XML and HTML used widely at the National Aeronautics Space Administration (NASA) and industry.

Maluf, David A.↗

Protein Crystallization Using Room Temperature Ionic Fluids

The ionic liquids (ILs) 1-butyl-3-methylimidizolium chloride (C4mim-C1), 1-butyl-3- methylimidizolium diethyleneglycol monomethylethersulfate ([C4mim]DEMGS), and 1-butyl-1 -methylpyrollidinium dihydrogenphosphate ([p1,4]dhp) were tested for their effects on the crystallization of the proteins canavalin, beta-lactoglobulin B, xylanase, and glucose isomerase, using a standard high throughput screen. The crystallization experiments were set up with the ILs added to the protein solutions at 0.2 and 0.4 M final concentrations. Crystallization droplets were set up at three proteixprecipitant ratios (1:1, 2:1, and 4:l), which served to progressively dilute the effects of the screen components while increasing the equilibrium protein and IL concentrations. Crystals were obtained for all four proteins at a number of conditions where they were not obtained from the IL-free control experiment. Over half of the protein-IL combinations tested had more successful outcomes than negative, where the IL-free crystallization was better than the corresponding IL-containing outcome, relative to the control. One of the most common causes of a negative outcome was solubilization of the protein by the IL, resulting in a clear drop. In one instance, we were able to use the IL-induced solubilizing to obtain beta-lactoglobulin B crystals from conditions that gave precipitated protein in the absence of IL. The results suggest that it may be feasible to develop ILs specifically for the task of macromolecule crystallization.

Pusey, Marc L.↗

Computational Modeling Develops Ultra-Hard Steel

Glenn Research Center's Mechanical Components Branch developed a spiral bevel or face gear test rig for testing thermal behavior, surface fatigue, strain, vibration, and noise; a full-scale, 500-horsepower helicopter main-rotor transmission testing stand; a gear rig that allows fundamental studies of the dynamic behavior of gear systems and gear noise; and a high-speed helical gear test for analyzing thermal behavior for rotorcraft. The test rig provides accelerated fatigue life testing for standard spur gears at speeds of up to 10,000 rotations per minute. The test rig enables engineers to investigate the effects of materials, heat treat, shot peen, lubricants, and other factors on the gear's performance. QuesTek Innovations LLC, based in Evanston, Illinois, recently developed a carburized, martensitic gear steel with an ultra-hard case using its computational design methodology, but needed to verify surface fatigue, lifecycle performance, and overall reliability. The Battelle Memorial Institute introduced the company to researchers at Glenn's Mechanical Components Branch and facilitated a partnership allowing researchers at the NASA Center to conduct spur gear fatigue testing for the company. Testing revealed that QuesTek's gear steel outperforms the current state-of-the-art alloys used for aviation gears in contact fatigue by almost 300 percent. With the confidence and credibility provided by the NASA testing, QuesTek is commercializing two new steel alloys. Uses for this new class of steel are limitless in areas that demand exceptional strength for high throughput applications.

Source record↗

Lightweight and High Angular Resolution X-Ray Optics

The International X-ray Observatory (IXO) mission requires a lightweight and high throughput spectroscopic telescope. The fabrication, alignment, and integration of this mirror assembly require breakthroughs in many areas. In this paper we report on our recent progress in all these areas, including mirror fabrication, coating, metrology, alignment, mechanical characteristics, and their integration into mirror modules. In particular, we will also outline our plan for the next few of years, showing approaches that will progress toward reaching the 5' HPD requirement.

Zhang, William↗

X-Ray Calorimeter Arrays for Astrophysics

High-resolution x-ray spectroscopy is a powerful tool for studying the evolving universe. The grating spectrometers on the XMM and Chandra satellites started a new era in x-ray astronomy, but there remains a need for instrumentation that can provide higher spectral resolution with high throughput in the Fe-K band (around 6 keV) and can enable imaging spectroscopy of extended sources, such as supernova remnants and galaxy clusters. The instrumentation needed is a broad-band imaging spectrometer - basically an x-ray camera that can distinguish tens of thousands of x-ray colors. The potential benefits to astrophysics of using a low-temperature calorimeter to determine the energy of an incident x-ray photon via measurement of a small change in temperature was first articulated by S. H. Moseley over two decades ago. In the time since, technological progress has been steady, though full realization in an orbiting x-ray telescope is still awaited. A low-temperature calorimeter can be characterized by the type of thermometer it uses, and three types presently dominate the field. The first two types are temperature-sensitive resistors - semiconductors in the metal-insulator transition and superconductors operated in the superconducting-normal transition. The third type uses a paramagnetic thermometer. These types can be considered the three generations of x-ray calorimeters; by now each has demonstrated a resolving power of 2000 at 6 keV, but only a semiconductor calorimeter system has been developed to spaceflight readiness. The Soft X-ray Spectrometer on Astro-H, expected to launch in 2013, will use an array of silicon thermistors with I-IgTe x-ray absorbers that will operate at 50 mK. Both the semiconductor and superconductor calorimeters have been implemented in small arrays, kilo-pixel arrays of the superconducting calorimeters are just now being produced, and it is anticipated that much larger arrays will require the non-dissipative advantage of magnetic thermometers.

Kilbourne, Caroline A.↗

Improved Measurement of B(sub 22) of Macromolecules in a Flow Cell

An improved apparatus has been invented for use in determining the osmotic second virial coefficient of macromolecules in solution. In a typical intended application, the macromolecules would be, more specifically, protein molecules, and the protein solution would be pumped through a flow cell to investigate the physical and chemical conditions that affect crystallization of the protein in question. Some background information is prerequisite to a meaningful description of the novel aspects of this apparatus. A method of determining B22 from simultaneous measurements of the static transmittance (taken as an indication of concentration) and static scattering of light from the same location in a flowing protein solution was published in 2004. The apparatus used to implement the method at that time included a dual-detector flow cell, which had two drawbacks: a) The amount of protein required for analysis of each solution condition was of the order of a milligram - far too large a quantity for a high-throughput analysis system, for which microgram or even nanogram quantities of protein per analysis are desirable. b) The design of flow cell was such that two light sources were used to probe different regions of the flowing solution. Consequently, the apparatus did not afford simultaneous measurements at the same location in the solution and, hence, did not guarantee an accurate determination of B22.

Wilson, Wilbur↗

Catalysts for Efficient Production of Carbon Nanotubes

Several metal alloys have shown promise as improved catalysts for catalytic thermal decomposition of hydrocarbon gases to produce carbon nanotubes (CNTs). Heretofore almost every experiment on the production of carbon nanotubes by this method has involved the use of iron, nickel, or cobalt as the catalyst. However, the catalytic-conversion efficiencies of these metals have been observed to be limited. The identification of better catalysts is part of a continuing program to develop means of mass production of high-quality carbon nanotubes at costs lower than those achieved thus far (as much as $100/g for purified multi-wall CNTs or $1,000/g for single-wall CNTs in year 2002). The main effort thus far in this program has been the design and implementation of a process tailored specifically for high-throughput screening of alloys for catalyzing the growth of CNTs. The process includes an integral combination of (1) formulation of libraries of catalysts, (2) synthesis of CNTs from decomposition of ethylene on powders of the alloys in a pyrolytic chemical-vapor-decomposition reactor, and (3) scanning- electron-microscope screening of the CNTs thus synthesized to evaluate the catalytic efficiencies of the alloys. Information gained in this process is put into a database and analyzed to identify promising alloy compositions, which are to be subjected to further evaluation in a subsequent round of testing. Some of these alloys have been found to catalyze the formation of carbon nano tubes from ethylene at temperatures as low as 350 to 400 C. In contrast, the temperatures typically required for prior catalysts range from 550 to 750 C.

Sun, Ted X.↗

Lightweight and High Angular Resolution X-Ray Optics

The International X-ray Observatory (IXO) mission requires a lightweight and high throughput spectroscopic telescope. The fabrication, alignment, and integration of this mirror assembly require breakthroughs in many areas. In this paper we report on our recent progress in all these areas, including mirror fabrication, coating, metrology, alignment, mechanical characteristics, and their integration into mirror modules. In particular, we will also outline our plan for the next few of years, showing approaches that will progress toward reaching the 5" HPD requirement.

Zhang, William W.↗

VLSI Design of a Turbo Decoder

A very-large-scale-integrated-circuit (VLSI) turbo decoder has been designed to serve as a compact, high-throughput, low-power, lightweight decoder core of a receiver in a data-communication system. In a typical contemplated application, such a decoder core would be part of a single integrated circuit that would include the rest of the receiver circuitry and possibly some or all of the transmitter circuitry, all designed and fabricated together according to an advanced communication-system-on-a-chip design concept. Turbo codes are forward-error-correction (FEC) codes. Relative to older FEC codes, turbo codes enable communication at lower signal-to-noise ratios and offer greater coding gain. In addition, turbo codes can be implemented by relatively simple hardware. Therefore, turbo codes have been adopted as standard for some advanced broadband communication systems.

Fang, Wai-Chi↗