Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

High resolution spectroscopy of the 11.3 micron emission band

High resolution spectra of the 11.3 micron emission band in M82 and NGC 7027 were obtained using the University of Texas IR echelle spectrometer on the IRTF in April 1988. The spectral resolution was 0.004 micron, with coverage from 11.0 to 11.6 microns. Spectra were measured at ten positions along a 10 min. long slit. Analysis of the data is still in progress, but initial results show no clear evidence of narrow structure within the feature. The analysis will involve comparison of the observed spectra to laboratory and predicted spectra of Polycylic Aromatic Hydrocarbons (PAHs) and Quenched Carbonaceous Composite (QCCs) to determine which may be responsible for the emission. The spectra will be examined with a goal of determining whether the emission is caused by molecular or solid state material. The data are also examined for evidence of variations in the shape and strength of the 11.3 micron feature with position on the sky. In NGC 7027 the 10 min. long slit went across the edge of the ionized nebulae, allowing comparison of emission from both ionized and neutral regions.

Achtermann, Jeff M.↗

Hubble Space Telescope: Goddard high resolution spectrograph instrument handbook. Version 2.1

The Goddard High Resolution Spectrograph (GHRS) is an ultraviolet spectrometer which has been designed to exploit the imaging and pointing capabilities of the Hubble Space Telescope. It will obtain observations of astronomical sources with greater spectral, spatial and temporal resolution than has been possible with previous space-based instruments. Data from the GHRS will be applicable to many types of scientific investigations, including studies of the interstellar medium, stellar winds, chromospheres and coronae, the byproducts and endproducts of stellar evolution, planetary atmospheres, comets, and many kinds of extragalactic sources. This handbook is intended to introduce the GHRS to potential users. The main purpose is to provide enough information to explore the feasibility of possible research projects and to plan, propose and execute a set of observations. An overview of the instrument performance, which should allow one to evaluate the suitability of the GHRS to specific projects, and a somewhat more detailed description of the GHRS hardware are given. How observing programs will be carried out, the various operating modes of the instrument, and the specific information about the performance of the instrument needed to plan an observation are discussed.

Duncan, Douglas K.↗

Calibration of the Rosat High Resolution Imager (HRI)

The microchannel plate-based High Resolution Imager (HRI) is one of the focal plane instruments of the Rosat X-ray telescope that was launched on 1 June 1990. The calibration of the HRI is reported and preliminary results from the in-orbit calibration are presented. The quantum efficiency of the detector has been determined as a function of energy, the spatial variation of quantum efficiency, geometric nonlinearities, background, imaging performance, and UV sensitivity. Results of periodic tests of the temporal stability of the instrument are also reported.

Zombeck, M. V.↗

On the accuracy of CO line positions for high resolution IR stellar spectroscopy

The paper demonstrates the high accuracy of line positions derived from improved sets of Dunham coefficients for the four more abundant isotopic species of carbon monoxide - (C-12)(O-16), (C-13)(O-16), (C-12)(O-18), and (C-12)(O-17) - which are present in the sun and in cool stellar atmospheres. These new spectroscopic constants make it possible to predict very accurate positions of CO lines at any J-values, especially at very high rotational excitation (up to J around 135). Earlier proposed identifications of CO lines at large J-values are checked, and some incorrect identifications in sunspot spectra are found. The present accurate line positions are also compared with predictions from other available sets of molecular constants. It is concluded that the present improved sets of molecular constants are the most appropriate to all problems of high-resolution stellar and solar spectroscopy at any J- and v-values, particularly for synthetic spectra of cool stars.

Sauval, A. J.↗

A search for chromospheric emission in A-type stars using the Goddard High-Resolution Spectrograph

We have used the Goddard High-Resolution Spectrograph (GHRS) on the Hubble Space Telescope (HST) to search for chromospheric emission in the ultraviolet C II 1335 A lines of eight A-type stars. The B-V colors of these stars range from 0.12 to 0.22. We have detected emission in the spectrum of the A7 V star Altair, but in no other star. We present tentative evidence that the emission from Altair is blueshifted by approximately 60 km per sec or more with respect to the photospheric spectrum of this star. We interpret this as expansion and suggest that the base of the A star winds that we have proposed in earlier work may lie within the chromosphere. Together with International Ultraviolet Explorer (IUE) spectra, our observations indicate that in ordinary main-sequence stars the onset of convection zones capable of supporting detectable chromospheres occurs in the close vicinity of B-V = 0.22.

Simon, Theodore↗

Goddard High-Resolution Spectrograph Observations of Procyon and HR1099

Goddard High Resolution Spectrograph (GHRS) observations have revealed the presence of broad wings in the transition-region lines of AU Mic and Capella. It has been proposed that these wings are signatures of microflares in the transition regions of these stars and that the solar analog for this phenomenon might be the 'transition region explosive events' discussed by Dere, Bartoe, & Brueckner. We have analyzed GHRS observations of Procyon (F5 IV-V) and HR 1099 (K1 IV + G5 IV) to search for broad wings in the UV emission lines of these stars. We find that the transition-region lines of HR 1099, which are emitted almost entirely by the K1 star, do indeed have broad wings that are even more prominent than those of AU Mic and Capella. This is consistent with the association of the broad wings with microflaring since HR 1099 is a very active binary system. In contrast, the transition-region lines of Procyon, a relatively inactive star, do not show evidence for broad wings, with the possible exception of N v lambda1239. However, Procyon's lines do appear to have excess emission in their blue wings. Linsky et al. found no evidence for broad wings in Capella's chromospheric lines, but we find that the Mg II resonance lines of HR 1099 do have broad wings. The striking resemblance between HR 1099's Mg II and C iv lines suggests that the Mg II line profiles may be regulated by turbulent processes similar to those that control the transition-region line profiles. If this is the case, microflaring may be occurring in the K1 star's chromosphere as well as in its transition region. However, radiative transfer calculations suggest that the broad wings of the Mg II lines can also result from normal chromospheric opacity effects rather than pure turbulence. The prominence of broad wings in the transition region and perhaps even chromospheric lines of active stars suggests that microflaring is very prevalent in the outer atmospheres of active stars.

Wood, Brian E.↗

High Resolution Imaging Spectrometer (HIRIS): Science and Instrument

The High Resolution Imaging Spectrometer (HIRIS) is a facility instrument slated for flight on the second of the EOS-A series of platforms. HIRIS is designed to acquire 24-km wide, 30-m pixel images in 192 spectral bands simultaneously in the 0.4-2.45-micrometer wavelength region. With pointing mirrors it can sample any place on Earth, except the poles, every two days. HIRIS operates at the intermediate scale between the human and the global and therefore links studies of Earth surface processes to global monitoring carried out by lower-resolution instruments. So far, over 50 science data products from HIRIS images have been identified in the fields of atmospheric gases, clouds, snow and ice, water, vegetation, and rocks and soils. The key attribute of imaging spectrometry that makes it possible to derive quantitative information from the data is the large number of contiguous spectral bands. Therefore spectrum matching techniques can be applied. Such techniques are not possible with present-day, multispectral scanner data.

Goetz, Alexander F. H.↗

Soot Nanostructure: Using Fringe Analysis Software on High Resolution Transmission Electron Microscopy of Carbon Soot

Using high resolution transmission electron images of carbon nanotubes and carbon particles, we are able to use image analysis program to determine several carbon fringe properties, including length, separation, curvature and orientation. Results are shown in the form of histograms for each of those quantities. The combination of those measurements can give a better indication of the graphic structure within nanotubes and particles of carbon and can distinguish carbons based upon fringe properties. Carbon with longer, straighter and closer spaced fringes are considered graphite, while amorphous carbon contain shorter, less structured fringes.

King, James D.↗

High Resolution Infrared Spectroscopy of Molecules of Terrestrial and Planetary Interest

In collaboration with the laboratory spectroscopy group of the Ames Atmospheric Physics Research Branch (SGP), high resolution infrared spectra of molecules that are of importance for the dynamics of the earth's and other planets' atmospheres were acquired using the SGP high resolution Fourier transform spectrometer and gas handling apparatus. That data, along with data acquired using similar instrumentation at the Kitt Peak National Observatory was analyzed to determine the spectral parameters for each of the rotationally resolved transitions for each molecule. Those parameters were incorporated into existing international databases (e.g. HITRANS and GEISA) so that field measurements could be converted into quantitative information regarding the physical and chemical structures of earth and planetary atmospheres.

Freedman, Richard S.↗

High Resolution Wavenumber Standards for the Infrared. (IUPAC Recommendations 1995)

The calibration of high resolution infrared spectra is generally more precise than accurate even when they are recorded with Fourier interferometers. In order to improve the consistency of the spectral measurements, an IUPAC project has been undertaken. Its aim was to recommend a selection of spectral lines as wavenumber standards for absolute calibration in the infrared. This paper will report the final recommendations in the spectral range extending from about 4 to about 7000 cm(be).

High Resolution Wavenumber Standards↗

Immunohistochemical myofiber typing and high-resolution myofibrillar lesion detection in LR white embedded muscle

We have developed a method of fixing, embedding, sectioning, and staining that allows high-resolution detection of myofibrillar structure and myosin immunocytochemical muscle fiber typing in serial semithin sections of LR White plastic embedded muscle at the light microscopic level. Traditional approaches, such as cryostat sections, permit fiber typing, but small myofibrillar lesions (1-3 sarcomeres) are difficult to detect because of section thickness. Semithin sections of hydrophobic resins do not stain well either histochemically or immunocytochemically. Electron microscopy can resolve lesions and discriminate fiber types based on morphology, but the sampling area is small. Our goal was to develop a rapid method for defining both fiber type and high-resolution primary myofibrillar lesion damage. Mild fixation (1-4% paraformaldehyde, 0. 05-0.1% glutaraldehyde) and embedment in a hydrophilic resin (LR White) were used. Myofibrillar structure was extremely well preserved at the light microscopic (LM) level, and lesions could be readily resolved in Toluidine blue stained 500-nm sections. Fiber type was defined by LM immunomyosin staining of serial plastic semithin sections, which demonstrated reciprocal staining patterns for "fast (Sigma M4276) and "total" (skeletal muscle) myosins (Sigma M7523). Copyright 2000 Wiley-Liss, Inc.

NASA Program Fundamental Space Biology↗

A Space-based, High-resolution View of Notable Changes in Urban Nox Pollution Around the World (2005 - 2014)

Nitrogen oxides (NOxNO+NO2) are produced during combustion processes and, thus may serve as a proxy for fossil fuel-based energy usage and committed greenhouse gases and other pollutants. We use high-resolution nitrogen dioxide (NO2) data from the Ozone Monitoring Instrument (OMI) to analyze changes in urban NO2 levels around the world from 2005 to 2014, finding complex heterogeneity in the changes. We discuss several potential factors that seem to determine these NOx changes. First, environmental regulations resulted in large decreases. The only large increases in the United States may be associated with three areas of intensive energy activity. Second, elevated NO2 levels were observed over many Asian, tropical, and subtropical cities that experienced rapid economic growth. Two of the largest increases occurred over recently expanded petrochemical complexes in Jamnagar (India) and Daesan (Korea). Third, pollution transport from China possibly influenced the Republic of Korea and Japan, diminishing the impact of local pollution controls. However, in China, there were large decreases over Beijing, Shanghai, and the Pearl River Delta, which were likely associated with local emission control efforts. Fourth, civil unrest and its effect on energy usage may have resulted in lower NO2 levels in Libya, Iraq, and Syria. Fifth, spatial heterogeneity within several megacities may reflect mixed efforts to cope with air quality degradation. We also show the potential of high-resolution data for identifying NOx emission sources in regions with a complex mix of sources. Intensive monitoring of the world's tropical subtropical megacities will remain a priority, as their populations and emissions of pollutants and greenhouse gases are expected to increase significantly.

spatial heterogeneity↗

Measuring molecular flows with high-resolution stimulated Raman spectroscopy

It is proposed to use high-resolution stimulated Raman spectroscopy to directly measure high-speed molecular flow velocities in wind tunnels and in combustive chambers. A feasibility study indicates that flow speeds from Mach 0.04 up may be measured with the proposed method using available laser systems. It is pointed out that the success of the proposed technique will make it possible to measure all interesting flow parameters, i.e., species concentration, temperature, and velocity, in a time of less than 1 microsecond at a repetition rate of 10,000/s using a single experimental arrangement.

She, C. Y.↗

Routine High-Resolution Forecasts/Analyses for the Pacific Disaster Center: User Manual

Enclosed herein is our HWCMO user manual. This manual constitutes the final report for our NASA/PDC grant, NASA NAG5-8730, "Routine High Resolution Forecasts/Analysis for the Pacific Disaster Center". Since the beginning of the grant, we have routinely provided experimental high resolution forecasts from the RSM/MSM for the Hawaii Islands, while working to upgrade the system to include: (1) a more robust input of NCEP analyses directly from NCEP; (2) higher vertical resolution, with increased forecast accuracy; (3) faster delivery of forecast products and extension of initial 1-day forecasts to 2 days; (4) augmentation of our basic meteorological and simplified fireweather forecasts to firedanger and drought forecasts; (5) additional meteorological forecasts with an alternate mesoscale model (MM5); and (6) the feasibility of using our modeling system to work in higher-resolution domains and other regions. In this user manual, we provide a general overview of the operational system and the mesoscale models as well as more detailed descriptions of the models. A detailed description of daily operations and a cost analysis is also provided. Evaluations of the models are included although it should be noted that model evaluation is a continuing process and as potential problems are identified, these can be used as the basis for making model improvements. Finally, we include our previously submitted answers to particular PDC questions (Appendix V). All of our initially proposed objectives have basically been met. In fact, a number of useful applications (VOG, air pollution transport) are already utilizing our experimental output and we believe there are a number of other applications that could make use of our routine forecast/analysis products. Still, work still remains to be done to further develop this experimental weather, climate, fire danger and drought prediction system. In short, we would like to be a part of a future PDC team, if at all possible, to further develop and apply the system for the Hawaiian and other Pacific Islands as well as the entire Pacific Basin.

Roads, John↗

High resolution magnetic resonance imaging of the calcaneus: age-related changes in trabecular structure and comparison with dual X-ray absorptiometry measurements

A high-resolution magnetic resonance imaging (MRI) protocol, together with specialized image processing techniques, was applied to the quantitative measurement of age-related changes in calcaneal trabecular structure. The reproducibility of the technique was assessed and the annual rates of change for several trabecular structure parameters were measured. The MR-derived trabecular parameters were compared with calcaneal bone mineral density (BMD), measured by dual X-ray absorptiometry (DXA) in the same subjects. Sagittal MR images were acquired at 1.5 T in 23 healthy women (mean age: 49.3 +/- 16.6 [SD]), using a three-dimensional gradient echo sequence. Image analysis procedures included internal gray-scale calibration, bone and marrow segmentation, and run-length methods. Three trabecular structure parameters, apparent bone volume (ABV/TV), intercept thickness (I.Th), and intercept separation (I.Sp) were calculated from the MR images. The short- and long-term precision errors (mean %CV) of these measured parameters were in the ranges 1-2% and 3-6%, respectively. Linear regression of the trabecular structure parameters vs. age showed significant correlation: ABV/TV (r2 = 33.7%, P < 0.0037), I.Th (r2 = 26.6%, P < 0.0118), I.Sp (r2 = 28.9%, P < 0.0081). These trends with age were also expressed as annual rates of change: ABV/TV (-0.52%/year), I.Th (-0.33%/year), and I.Sp (0.59%/year). Linear regression analysis also showed significant correlation between the MR-derived trabecular structure parameters and calcaneal BMD values. Although a larger group of subjects is needed to better define the age-related changes in trabecular structure parameters and their relation to BMD, these preliminary results demonstrate that high-resolution MRI may potentially be useful for the quantitative assessment of trabecular structure.

NASA Discipline Number 26-10↗

Full-Coverage High-Resolution Daily PM(sub 2.5) Estimation using MAIAC AOD in the Yangtze River Delta of China

Satellite aerosol optical depth (AOD) has been used to assess population exposure to fine particulate matter (PM (sub 2.5)). The emerging high-resolution satellite aerosol product, Multi-Angle Implementation of Atmospheric Correction(MAIAC), provides a valuable opportunity to characterize local-scale PM(sub 2.5) at 1-km resolution. However, non-random missing AOD due to cloud snow cover or high surface reflectance makes this task challenging. Previous studies filled the data gap by spatially interpolating neighboring PM(sub 2.5) measurements or predictions. This strategy ignored the effect of cloud cover on aerosol loadings and has been shown to exhibit poor performance when monitoring stations are sparse or when there is seasonal large-scale missngness. Using the Yangtze River Delta of China as an example, we present a Multiple Imputation (MI) method that combines the MAIAC high-resolution satellite retrievals with chemical transport model (CTM) simulations to fill missing AOD. A two-stage statistical model driven by gap-filled AOD, meteorology and land use information was then fitted to estimate daily ground PM(sub 2.5) concentrations in 2013 and 2014 at 1 km resolution with complete coverage in space and time. The daily MI models have an average R(exp 2) of 0.77, with an inter-quartile range of 0.71 to 0.82 across days. The overall Ml model 10-fold cross-validation R(exp 2) (root mean square error) were 0.81 (25 gm(exp 3)) and 0.73 (18 gm(exp 3)) for year 2013 and 2014, respectively. Predictions with only observational AOD or only imputed AOD showed similar accuracy.Comparing with previous gap-filling methods, our MI method presented in this study performed bette rwith higher coverage, higher accuracy, and the ability to fill missing PM(sub 2.5) predictions without ground PM(sub 2.5) measurements. This method can provide reliable PM(sub 2.5)predictions with complete coverage that can reduce biasin exposure assessment in air pollution and health studies.

PM2.5↗

High Resolution Triple Axis X-Ray Diffraction Analysis of II-VI Semiconductor Crystals

The objective of this research program is to develop methods of structural analysis based on high resolution triple axis X-ray diffractometry (HRTXD) and to carry out detailed studies of defect distributions in crystals grown in both microgravity and ground-based environments. HRTXD represents a modification of the widely used double axis X-ray rocking curve method for the characterization of grown-in defects in nearly perfect crystals. In a double axis rocking curve experiment, the sample is illuminated by a monochromatic X-ray beam and the diffracted intensity is recorded by a fixed, wide-open detector. The intensity diffracted by the sample is then monitored as the sample is rotated through the Bragg reflection condition. The breadth of the peak, which is often reported as the full angular width at half the maximum intensity (FWHM), is used as an indicator of the amount of defects in the sample. This work has shown that high resolution triple axis X-ray diffraction is an effective tool for characterizing the defect structure in semiconductor crystals, particularly at high defect densities. Additionally, the technique is complimentary to X-ray topography for defect characterization in crystals.

Volz, H. M.↗

High resolution infrared absorption spectra of various trace gases present in the upper atmosphere of the Earth

The objective of NASA Grant NsG 7473 was to obtain and analyze high resolution infrared absorption spectra of various trace gases present in the Earth's upper atmosphere. The goal of the spectral analysis was to obtain values of absorption line strengths, widths and frequencies of sufficient accuracy for use in upper atmosphere trace gas monitoring. During the early phase of the grant, high resolution spectra were obtained from two instruments. One was the 0.02/cm resolution vacuum grating spectrometer at the Florida State University and the other was the 0.01/cm resolution Fourier transform spectrometer at the McMath solar telescope at the Kitt Peak Observatory. Using these instruments, a considerable amount of spectra of methane and hydrogen peroxide were obtained and analyzed. During the latter years of the project, data taking was halted while efforts were devoted to building a new 0.0025/cm resolution vacuum Fourier transform spectrometer. Progress during this phase of the grant then became greatly slowed due to a lack of suitable graduate students in the program. However, the instrument was completed and brought to the point of producing interferograms.

Hunt, Robert H.↗