Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Pilot Testing of a Highly Efficient Pre-combustion Sorbent-based Carbon Capture System

TDA developed and demonstrated a highly efficient pre-combustion carbon capture system. The overall objective of this work was to develop a new sorbent-based pre-combustion carbon capture technology for Integrated Gasification Combined Cycle (IGCC) power plants. In this project our goal was to demonstrate the techno-economic viability of the new technology by 1) demonstrating it in large-scale slipstream tests, and 2) carrying out a high fidelity engineering and cost analysis. TDA’s process used an advanced physical adsorbent that selectively removes CO 2 from coal-derived synthesis gas above the dew point of the gas at temperatures as high as 300°C. The sorbent consists of a mesoporous carbon whose surface was grafted with functional groups that remove CO 2 via a well-known acid-base interaction. As documented in bench-scale experiments and field tests with actual coal gas, the sorbent achieved a very high capacity for CO 2 at temperatures as high as 300°C. The sorbent bound CO 2 more strongly than common physical adsorbents, providing the chemical potential needed for the high temperature operation. However, because CO 2 does not form a true covalent bond with the surface sites (as is the case with chemical absorbents), the sorbent regeneration could be carried out with only a very small energy input. The heat input to regenerate our sorbent was only 4.9 kcal per mol of CO 2 , which is much lower than that for chemical absorbents (e.g., 29.9 kcal/mol CO 2 for sodium carbonate) and was similar to the requirements of physical solvents (e.g., 4 kcal/mol CO 2 for Selexol TM ). Because the sorbent operates above the dew point of the synthesis gas (unlike the Selexol TM process), a higher power cycle efficiency can be achieved. With previous DOE/NETL funding (Contract No. DE-FE-0000469), we demonstrated the techno-economic viability of the technology in bench-scale tests and slipstream demonstrations at the National Carbon Capture Center (NCCC), Wilsonville, Alabama and Wabash River IGCC plant in Terra Haute, Indiana. We demonstrated a stable working CO 2 capacity for over 11,650 cycles with simulated synthesis gas. We also evaluated its performance with actual synthesis gas in two test campaigns at the Wabash River IGCC Plant, Terre Haute, IN and the National Carbon Capture Center (NCCC), Wilsonville, AL. The slipstream tests clearly showed that the actual coal gas constituents and potential contaminants (e.g. trace metals, halides, tars) had no effect on the sorbent’s ability to remove CO 2 (the same sorbent beds were used in both field tests with no sign of deactivation for 2,000 cycles with over 26,750 SCF of gas treated). As expected, due to the high temperature CO 2 removal capability and low energy needed to regenerate the sorbent, the power cycle efficiency with our process was greater than 34% on a higher heating value (HHV) basis; in comparison, the same IGCC plant equipped with the Selexol TM solvent for carbon capture can only achieve 31.4% HHV efficiency. The capital cost for an IGCC system with TDA’s process is estimated as $2,417/kW e , which is 12% lower than that of the IGCC/ Selexol TM process. The levelized cost for electricity including the transport, storage and monitoring (TS&M) cost for CO 2 was calculated as $\$ $92.9/MWh (lowest reported to our knowledge), which is much better than the $105.2/MWh estimated for the IGCC/ Selexol TM process. In this project (DE-FE0013105), TDA Research, in collaboration with our partners Gas Technology Institute (GTI), Illinois Clean Coal Institute (ICCI), University of California, Irvine (UCI), University of Alberta (UOA), Siemens, NCCC and Sinopec advanced the technical maturity of the technology; scaling it up by a factor of 100. We optimized the reactor design using computational fluid dynamics (CFD); using adsorption modeling we improved the pressure swing adsorption (PSA) cycle sequence. We carried out two field test campaigns with a fully-equipped 0.1 MW e prototype unit (for a total of 844 hours) using actual synthesis gas to prove the viability of the new technology. A successful 30 day (707 hrs) evaluation was completed at NCCC under air blown gasification conditions. We demonstrated 97.3% carbon capture at 1,500 SLPM, 93% carbon capture at 1,800 SLPM, and 90% carbon capture at 2,100 SLPM in the NCCC tests. We also demonstrated the system for 137 hours at a Sinopec petrochemical plant under oxygen blown gasification, demonstrating 86% carbon capture at 2,660 SLPM. In collaboration with University of California, Irvine (UCI), we completed a techno-economic analysis (TEA) for TDA’s warm gas cleanup technology integrated to IGCC power plant. The net plant efficiencies (on a coal HHV basis) for the warm gas cleanup cases were estimated to be 34.0% for E-GasTM gasifier, 34.4% for GE gasifier, 33.4 for the Shell gasifier and 34.2 for the TRIG TM gasifier (Cases 2, 4, 6 and 8 in this study) with a catalytic combustor for CO 2 purification, which are significantly higher than those for the Cold Gas Case, or an increase of as much as 12% in the heat rate for Case 2, 6% for Case 4, 9% for Case 6, and 9% for Case 8. The 1st year cost of electricity with the transport, storage and monitoring (TS&M) costs for the CO 2 included was $\$ $129.2/MWh for the E-GasTM gasifier Warm Gas Cleanup Case, $\$ $131.9/MWh for the GE gasifier Warm Gas Cleanup Case, $\$ $146.8/MWh for the Shell Gasifier Warm Gas Cleanup Case, and $\$ $129.9/MWh for the TRIG TM gasifier Warm Gas Cleanup Case. For comparison, the costs for the baseline Cold Gas CO 2 removal with Selexol for the different gasifiers were: $\$ $146.6/MWh for the E-Gas TM gasifier, $\$ $142.2/MWh for the GE gasifier, $\$ $159.0/MWh for the Shell gasifier and $\$ $144.3/MWh for the TRIG TM gasifier. In summary, the costs for our system were 7 to 12% lower than the corresponding Cold Gas Cleanup cases. The results of this techno-economic analysis suggested that TDA’s high temperature PSA-based Warm Gas Clean-up Technology can make a substantial improvement in the IGCC plant thermal performance for achieving near zero CO 2 emissions for E-Gas TM , GE, Shell and TRIG TM gasifier based IGCC power plants. The capital expenses were estimated to be lower than that of Selexol’s™. Taken together, the higher net plant efficiency and lower capital and operating costs resulted in substantial reduction in the cost of carbon capture for the IGCC plant equipped with TDA’s high temperature PSA-based carbon capture system. Finally, in collaboration with Gas Technology Institute (GTI) we completed the environmental health and safety assessment for TDA’s warm gas carbon capture technology.

01 COAL, LIGNITE, AND PEAT↗

High efficiency, low cost thin GaAs solar cells

The feasibility of fabricating space-resistant, high efficiency, light-weight, low-cost GaAs shallow-homojunction solar cells for space application is demonstrated. This program addressed the optimal preparation of ultrathin GaAs single-crystal layers by AsCl3-GaAs-H2 and OMCVD process. Considerable progress has been made in both areas. Detailed studies on the AsCl3 process showed high-quality GaAs thin layers can be routinely grown. Later overgrowth of GaAs by OMCVD has been also observed and thin FaAs films were obtained from this process.

Fan, J. C. C.↗

High‐Efficiency Organic Solar Cells with Wide Toleration of Active Layer Thickness

Industrial printing production of organic solar cells (OSCs) requires high power conversion efficiency (PCE) with wide toleration of active layer thickness. Herein, high‐efficiency thick‐film OSCs are demonstrated using a polymer fibril network strategy (FNS), which involves a donor polymer (PT2) that can self‐assemble into fibril nanostructure, and two nonfullerene acceptors with different crystalline properties. The fibril network can form a high‐speed hole transport channel and the addition of IDIC as a third component in active layers can improve the electron transport. As a result, the OSCs show high PCEs of ≈12% with wide toleration of active layer thickness (from 100 to 500 nm). The results indicate that FNS is a promising approach for the fabrication of highly efficient thick‐film PSCs, which can facilitate the commercialization of OSCs.

Weng, Kangkang↗

Thermal Cycling of Stationary Superconducting Rotor Coils for the High Efficiency Megawatt Motor

The self-cooled, superconducting rotor included in the design of the High Efficiency Megawatt Motor (HEMM) can produce magnetic field strengths far higher than those produced using conventional approaches. However, the superconductivity properties of high-temperature superconducting coils can degrade as the coil is repeatedly thermally cycled, significantly impacting the HEMM’s performance. To explore ways to reduce this risk, NASA researchers fabricated and tested several coils of increasing complexity. The results of the testing campaign indicate that NASA can fabricate and test full-scale superconducting coils for the rotor of the HEMM that can reliably survive repeated thermal cycling with no or acceptably slow degradation.

Electrified Aircraft Propulsion↗

Optimization of Triply Periodic Minimal Surface Heat Exchanger to Achieve Compactness, High Efficiency, and Low-Pressure Drop

With advancements in additive manufacturing (AM) techniques, high-quality triply periodic minimal surface (TPMS) structures can now be produced. TPMS walled heat exchangers (HX) hold significant potential for industrial applications and are receiving increasing attention. This paper explores the impact of various TPMS design variables on flow and thermal performance to optimize TPMS heat exchangers for compactness, high efficiency, and low pressure drop. The design variables examined include the type of TPMS lattice, unit cell size, wall thickness, aspect ratio, TPMS orientation, and equivalent thickness. The study reveals that the flow and heat transfer performance of TPMS structures are significantly affected by these design variables. For the Gyroid, Diamond, and SplitP lattices, performance is nearly identical when the surface-to-volume ratio is kept constant. The average velocity of the fluid in the TPMS HX should be 0.3 m/s. The corresponding Re is between 300~800. Thin wall thickness, small equivalent thickness, and flat lattice configurations can significantly reduce pressure drop while maintaining the overall heat transfer coefficient. Additionally, the angle between the flow direction and TPMS orientation can increase pressure drop. Three aluminum heat exchangers were successfully printed using an AM machine, and testing results are comparable with theoretical prediction.

42 ENGINEERING↗

High efficiency epitaxial GaAs/GaAs and GaAs/Ge solar cell technology using OM/CVD

A technology for fabricating high efficiency, thin film GaAs solar cells on substrates appropriate for space and/or terrestrial applications was developed. The approach adopted utilizes organometallic chemical vapor deposition (OM-CVD) to form a GaAs layer epitaxially on a suitably prepared Ge epi-interlayer deposited on a substrate, especially a light weight silicon substrate which can lead to a 300 watt per kilogram array technology for space. The proposed cell structure is described. The GaAs epilayer growth on single crystal GaAs and Ge wafer substrates were investigated.

Wang, K. L.↗

Performance Testing of a Lightweight, High Efficiency 95 K Cryocooler

Performance data are presented for a flight-like, lightweight, high efficiency pulse tube cryogenic cooler. The cooler has a mass of less than 4.0 kg, and an efficiency of 12 W/W, which is 18% of Carnot at 95 K, nearly double the efficiency of previous cooler designs, The mass of the cooler has been reduced by approximately a factor of three. The design point cooling power is 10 watts at 95 K at a heat rejection temperature of 300 K. The no-load temperature is 45 K. The compressor is built by Hymatic Engineering, UK, and is of a horizontally opposed piston design using flexure bearings. The vertical pulse tube is built by TRW with the heat exchanger or cold block located approximately mid-way along the tube. The final assembly and integration is also performed by TRW. The inertance tube and dead volume are contained within one of the compressor end caps. The cooler was developed by TRW under a joint NASA-DOD program, and has a goal of 10 yr operating lifetime. Potential NASA applications will focus on using coolers of this type in Zero boil off (ZBO) cryogen storage topologies for next generation launch vehicles. Zero boil off systems will feature significant reductions in tank size and Initial Mass to Low Earth Orbit (IMLEO), thereby significantly reducing the cost of access to space, and enabling future missions. The coolers can be used directly in liquid oxygen (LOx) or liquid methane ZBO systems, as shield coolers in liquid hydrogen tanks, or as first stage coolers in two-stage liquid hydrogen (LH2) ZBO cooler systems. Finally, the coolers could find applications in exploration missions where either propellants or breathable oxygen are extracted from the planetary atmosphere using a Sabatier or similar process. The gases could then be liquefied for storage either directly in return vehicle propellant tanks or on the planetary surface. Data presented were taken with the cooler operating in a vacuum of 10 (exp -5) torr, at controlled rejection temperatures from 300 K down to 275 K using a cold water heat exchanger bolted to the cooler. Heat loads were varied between 0.5 W and 15 W by supplying current to a 50 omega resistor mounted on a copper cold plate which was bolted to the cooler cold block. Silicon diodes mounted on both the cold plate and the heat exchanger provided accurate temperature measurement to within plus or minus 0.25 K and plus or minus 0.5 K respectively, up to 100 K with plus or minus 1% accuracy above 100 K. Input power to the compressor was limited to 180 W, corresponding to a maximum stroke of 80%.

Salerno, Lou↗

A high efficiency rooftop air conditioning system using multi-speed compressors

This study delineates a meticulous exploration of technologies to enhance the energy efficiency of rooftop air conditioning units, employing the DOE/ORNL heat pump design model for comprehensive engineering design and optimization. A baseline rooftop air conditioning unit, featuring a 13 ton (45.7 kW) cooling capacity and a 17.9 integrated energy efficiency ratio, served as the point of departure for substantive efficiency enhancements. Key modifications included the consolidation of two refrigerant circuits into one, integrating three parallel 2-stage (dual-speed) compressors, fan replacements with high-efficiency substitutes. Notably, a lower global warming potential refrigerant, R452B, was evaluated as a substitute for R-410A, demonstrating better performance in the lab prototype. Further, the achieved measured integrated energy efficiency ratio of 21.4 in the lab prototype surpassed the baseline integrated energy efficiency ratio. Comparative evaluations between R410A and R452B indicated heightened efficiency with the latter, showcasing a lab-demonstrated integrated energy efficiency ratio of 22.4 at the rated capacity of 13.8 ton (48.5 kW) and 23.9 integrated energy efficiency ratio at the rated capacity of 10 ton (35.2 kW). This research underscores the successful development of a rigorous, energy efficient rooftop air conditioning unit prototype with noteworthy environmental and economic implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Micro‐Scale Concentrating Photovoltaics: A Scalable Path Toward High‐Efficiency, Low‐Cost Solar Power

The global energy market is seeing increases in the electricity demand of a couple of percentage points annually. The photovoltaic (PV) industry is also growing rapidly every year. One of the PV technologies is concentrator photovoltaics (CPV). CPV uses high‐efficiency multijunction solar cells and optics to concentrate sunlight, thereby significantly reducing the amount of semiconductor material needed. Yet, due to the high upfont manufacturing cost of CPV, it currently does not offer a competitive price against silicon PV. With this a new branch is introduced to the industry, micro‐CPV, which can be broadly explained as the miniaturization of the solar cells and optical components. The motivation for micro‐CPV is lowering the cost by decreasing the material volume and enabling new system architectures and high‐throughput manufacturing methods, while still maintaining high electrical efficiencies, taking advantage of a lower thermal load, shorter optical paths, lower resistive losses, and lower material volumes. Herein, a comprehensive review of the technological advances is presented, key synergies between micro‐CPV and other industries sharing similar challenges are identified, exemplified by micro‐light emitting diodes display manufacturing. New assembly process development in these industries will facilitate commercial adoption of micro‐CPV with continued miniaturization while driving down the cost.

Jost, Norman↗

MODELING AND PARAMETRIC STUDY OF END-GAS AUTOIGNITION TO ALLOW THE REALIZATION OF ULTRA-LOW EMISSIONS, HIGH-EFFICIENCY HEAVY-DUTY SPARK-IGNITED NATURAL GAS ENGINES

Engine knock and misfire are barriers to pathways leading to high-efficiency Spark-Ignited (SI) Natural Gas (NG) engines. The general tendency to knock is highly dependent on engine operating conditions and the fuel reactivity. The problem is further complicated by the low emission limits and the wide range of chemical reactivity in pipeline-quality natural gas. Depending on the region and the source of the natural gas, its reactivity, described by its Methane Number (MN), which is analogous to the Octane Number for liquid SI fuels, can span from 65 to 95. In order to realize diesel-like efficiencies, SI NG engines must be designed to operate at high Brake Mean Effective Pressures (BMEP), near or beyond knock limits, over a wide range of fuel reactivity. This requires a deep understanding of the combustion-engine interactions pertaining to flame propagation and End-Gas Autoignition (EGAI), i.e., the autoignition of the unburned gas (end gas) ahead of the flame front. However, EGAI, if controlled, provides an opportunity to increase SI NG engine efficiency by increasing the combustion rate and the total fraction of burned fuel, mitigating the effects of the slow flame speeds characteristic of natural gas fuels, which generally reduce BMEP and increase unburned hydrocarbon emissions. For this reason, to realize diesel-like efficiencies and ultra-low emissions on SI NG engines, this work proposes the study of the main parameters influencing the modeling and prediction of NG EGAI to allow for its control. In this work, a novel EGAI detection and onset determination method was developed to reliably quantify EGAI for data analysis and engine control. The new method allowed the prediction of EGAI on SI NG engines without the need to use engine- and operating-condition-dependent thresholds and reduced the error in quantifying the fraction of the total energy released by the EGAI event by up to 40%pts. One- and three-dimensional engine models were then developed to study the engine/fuel interactions that lead to NG EGAI and its performance benefits. These models, although having decent agreement with experimental data, showed the need to account for NOx chemistry when predicting NG EGAI due to a consistently later prediction of the EGAI onset (~1.65 crank-angle degrees) and thus, a new reduced chemical mechanism for real NG fuels was developed containing NOx chemistry. The new reduced mechanism improved the EGAI onset prediction agreement to within ±0.5 crank-angle degrees and decreased simulation time during combustion by nearly 50% when using the further reduced AREIS50NOx chemical mechanism. These models were then used to study the role of NG composition on EGAI, evaluate the engine/fuel interactions leading to NG EGAI, and perform engine optimization while leveraging EGAI to increase thermal efficiency. Piston design optimization combined with a Controlled EGAI (C-EGAI) combustion mode allowed a Heavy-Duty (HD) SI NG engine to operate at diesel-like efficiencies, i.e., Brake Thermal Efficiency (BTE) ≥44%. Experimental and modeling data analysis revealed that earlier and faster heat release increases combustion efficiency by an average of 1%pts, increases work transferred to the piston resulting in a decrease in exhaust losses by 50% depending on the engine operating condition while slightly increasing heat losses. Finally, the simulation results revealed an opportunity to further enhance the BTE (up to 50%) by enabling C-EGAI combustion at leaner conditions, λ=1.4-1.6.

Bestel, Diego Bernardi↗

High Efficiency Cell Development

The specific activity was to improve the tandem junction Cell (TJC) as a high efficiency solar cell. The TJC development was to be consistent with module assembly and should contribute to the overall goals of the Low-Cost Solar Array Project. During 1978, TJC efficiency improved from approximately 11 percent to approximately 16 percent (AMI). Photogenerated current densities in excess of 42 mA/sq cm were observed at AMO. Open circuit voltages as high as 0.615 V were measured at AMO. Fill factor was only 0.68 - 0.75 due to a nonoptimum metal contact design. A device model was conceived in which the solar cell is modelled as a transitor. There are virtually no interconnect or packaging factor systems and the TJC is compatible with all conventional module fabrication systems. A modification of the TJC, the Front Surface Field (FSF) cell, was also explored.

Carbajal, B. G.↗

High Efficiency, 100 mJ per pulse, Nd:YAG Oscillator Optimized for Space-Based Earth and Planetary Remote Sensing

We report on a newly solid state laser transmitter, designed and packaged for Earth and planetary space-based remote sensing applications for high efficiency, low part count, high pulse energy scalability/stability, and long life. Finally, we have completed a long term operational test which surpassed 2 Billion pulses with no measured decay in pulse energy.

Remote Sensing↗

Using electron channeling contrast imaging to inform and improve the growth of high-efficiency GaAs solar cells on nanopatterned GaAs substrates

Patterned substrates provide opportunities for reducing the cost of high-efficiency III-V devices by incorporating mechanically weak layers beneficial for substrate reuse (e.g. by spalling). In this work, the functionality of electron channeling contrast imaging (ECCI) as a tool to efficiently understand and mitigate defect formation is exemplified by developing a process in which high-quality III-V material can be grown on nanopatterned GaAs substrates. Reactive ion etching used in the patterning process was found to damage the GaAs substrate surface, leading to the formation of stacking faults in the epitaxial material as observed by ECCI. Etching the patterned substrates in a 1 NH4OH: 1 H2O2: 50 DI H2O solution for 10 s prior to growth removed the substrate surface damage and stacking faults were no longer present. Growth of solar cell device structures initially produced samples with many macroscale flaws creating shunts in the devices, which complicated the assessment of material quality by device measurements. However, ECCI revealed that the epitaxial material surrounding macroscale flaws was free from any crystallographic defects such as stacking faults and threading dislocations. With this knowledge, we focused on refining the patterning process to eliminate the macroscale flaws. Solar cells were then grown on the improved nanopatterned substrates and exhibited device structures with defect densities less than 5 x 105 cm -2 and average conversion efficiency of 24.8%, nearly identical to devices grown on unpatterned epi-ready substrates (25.0%).

14 SOLAR ENERGY↗

Brushless dc motor has high efficiency, long life

Brushless dc motor operates as a commutator in a vacuum environment with high efficiency and long life. Because of its excellent response time, it can be used in the servomechanism field.

Studer, P. A.↗

Studies of oxygen-related and carbon-related defects in high-efficiency solar cells

Oxygen and carbon related defects in silicon, particularly as related to high-efficiency silicon solar cells were studied. A summary of oxygen processes in silicon versus process temperature was shown along with experimental results. The anamolous diffusion of oxygen was explained by the dissociation of the center allowing O sub i to move through the lattices.

Corbett, J. W.↗

NASA Small Engine Components Compressor Test Facility: High Efficiency Centrifugal Compressor Vaneless Diffuser and Transition Duct Configurations

The original vaned configuration of the High Efficiency Centrifugal Compressor (HECC) was developed with aggressive design targets to facilitate advancement of state-of-the-art technology in gas turbine compressors. This work documents modifications to the Small Engine Components Compressor Test Facility to support testing of the HECC vaneless diffuser and transition duct configurations, both of which are open geometries. These configurations were developed as follow-up studies to improve understanding of the differences between the predicted and actual performance of the original HECC vaned diffuser stage. Specifically, the vaneless diffuser was designed to provide the impeller with ideal exit conditions such that the impeller performance could be isolated from downstream stationary components, and the additively manufactured transition duct inlet configuration enables investigation into the effects of the inlet flow path on the stage performance. Features of note in the facility are active clearance control, bleed flow regulation, modular inlet configurations, and steady-state and fast-response instrumentation throughout the flow path. Details of the facility and instrumentation are presented as well as the baseline performance of the compressor stage. The geometry, performance, and detailed aerodynamic data have been made available to the public at https://storage.googleapis.com/heccdata/NASA-HECC-Data-Archive.zip.

centrifugal compressor↗

NASA Small Engine Components Compressor Test Facility: High Efficiency Centrifugal Compressor Vaneless Diffuser and Transition Duct Configurations

The original vaned configuration of the High Efficiency Centrifugal Compressor (HECC) was developed with aggressive design targets to facilitate advancement of state-of-the-art technology in gas turbine compressors. This work documents modifications to the Small Engine Components Compressor Test Facility to support testing of the HECC vaneless diffuser and transition duct configurations, both of which are open geometries. These configurations were developed as follow-up studies to improve understanding of the differences between the predicted and actual performance of the original HECC vaned diffuser stage. Specifically, the vaneless diffuser was designed to provide the impeller with ideal exit conditions such that the impeller performance could be isolated from downstream stationary components, and the additively manufactured transition duct inlet configuration enables investigation into the effects of the inlet flow path on the stage performance. Features of note in the facility are active clearance control, bleed flow regulation, modular inlet configurations, and steady-state and fast-response instrumentation throughout the flow path. Details of the facility and instrumentation are presented as well as the baseline performance of the compressor stage. The geometry, performance, and detailed aerodynamic data have been made available to the public at https://storage.googleapis.com/hecc-data/NASA-HECC-Data-Archive.zip.

centrifugal compressor↗