Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Development of a Sizing and Modeling Platform for District Energy Systems with Geothermal Heat Pumps

Existing tools for community or urban scale energy system modeling and simulation are often limited in their capabilities and require expert-level modeling proficiency to develop system models. To fill this gap, this paper proposes an integrated sizing and modeling platform for district energy systems with geothermal heat pumps. The proposed platform takes in geometric and non-geometric user inputs related to the buildings, borefield, and district energy loop. Then, the platform sizes the geothermal heat exchanger, generates a corresponding district energy system model, and runs an annual simulation automatically. We validated the simulation performance of the borefield in our tool against EnergyPlus. A case study is provided in this paper to demonstrate the workflow and simulation result plausibility of the proposed platform.

decarbonization↗

MHTLS Cross-flow Heat Exchanger Temperature Performance Data

The presentation and supporting information provide data on the performance of an engineering-scale cross-flow heat exchanger used in hydrothermal liquefaction (HTL). Temperature profiles are provide for the process of waste water treatment sludges and a food waste. The data can be used to model larger-scale heat exchangers used in HTL.

Bioenergy Technologies Tags Heat Exchanger HTL MHT↗

Geothermal Heat Pump System Showcase: Short-Term Validation of Borehole Heat Exchanger Performance from Field Data to Numerical Modeling: Preprint

Since 2011, a geothermal heat pump (GHP) system has been operating to provide space heating and cooling for the Solar Radiation and Research Laboratory building at the National Laboratory of the Rockies (NLR) in Golden, Colorado. The system consists of 23 vertical boreholes, each extending to a depth of 300 ft (91 m), connected to 11 water-to-air heat pump units and four circulation pumps. Between fiscal years 2023 and 2025, additional power meters and temperature sensors were retrofitted to support detailed system performance assessment and model development. This study presents preliminary monitoring results and the development of an initial numerical model of the borehole heat exchanger field. The model incorporated site-specific geometry, ground thermal properties derived from thermal response tests, and ambient temperatures, and simulated system behavior over a representative operating day in September. Model predictions of outlet temperatures were compared against corresponding field measurements. Results showed that modeling initialized with a simplified linear subsurface temperature gradient presents systematic discrepancies in outlet temperature, whereas incorporating depth-resolved borehole temperature measurements for initialization yields substantially improved agreement with observations. The findings highlight the sensitivity of short-term predictive modeling to the representation of initial subsurface thermal conditions and underscore the value of high-resolution field measurements for model calibration and validation. These preliminary results inform ongoing efforts to extend the modeling framework to longer time horizons and to refine monitoring and modeling strategies that support the design guidance and operational optimization of GHP systems in research and commercial buildings.

15 GEOTHERMAL ENERGY↗

Pressure drop and heat transfer characteristics of nitrate salt and supercritical CO 2 in a diffusion-bonded heat exchanger

A lab-scale 316/L stainless steel diffusion-bonded heat exchanger was examined within a coupled high-temperature test facility consisting of an atmospheric-pressure nitrate salt loop and a supercritical carbon dioxide (sCO 2 ) loop operating between 10 and 16 MPa. Pressure loss measurements collected for flow rates up to 0.55 kg/s of Solar Salt and up to 0.6 kg/s of carbon dioxide were used to generate friction factor correlations for the respective circular and semicircular zig-zag flow passages. Heat transfer measurements were also performed over a wide range of conditions to produce Nusselt correlations for the CO 2 and nitrate salt geometries. The Nusselt number is deduced from a heat transfer resistance network and overall conductance measurements collected across the operating envelope of the coupled sCO 2 – nitrate salt test facility. The CO 2 side correlation showed excellent agreement with existing correlations in the literature. Further, the salt side, having nearly circular channels with a different zig-zag angle and hydraulic diameter, yielded a new correlation applicable to the laminar flow regime. To examine the similitude of the friction correlations, pressure drop testing with water was performed on both sides of the component as well. Finally, results from non-destructive examination are discussed to provide insights regarding inspection methods and draining performance of high-temperature liquids in compact heat exchangers.

36 MATERIALS SCIENCE↗

Anisotropic Heating and Parallel Heat Flux in Electron-only Magnetic Reconnection with Intense Guide Fields

Electron-only reconnection (E-REC) is a process recently observed in the Earth’s magnetosheath, where magnetic reconnection occurs at electron kinetic scales, and ions do not couple to the reconnection process. Electron-only reconnection is likely to have a significant impact on the energy conversion and dissipation of turbulence cascades at kinetic scales in some settings. This paper investigates E-REC under different intensities of strong guide fields (the ratio between the guide field and the in-plane asymptotic field strength is 5, 10 and 20, respectively) via two-dimensional fully kinetic particle-in-cell simulations, focusing on electron heating. The simulations are initialized with a force-free current sheet equilibrium under various intensities of strong guide fields. Similarly to previous experimental studies, electron temperature anisotropy along separatrices is observed, which is found to be mainly caused by the variations of parallel temperature. Both regions of anisotropy and parallel temperature increase/decrease along separatrices become thinner with increasing guide fields. Besides, we find a transition from a quadrupolar to a hexapolar (six-polar) to an octopolar (eight-polar) structure in temperature anisotropy and parallel temperature as the guide field intensifies. Non-Maxwellian electron velocity distribution functions (EVDFs) at different locations in the three simulations are observed. Our results show that parallel electron velocity varies notably with different guide field intensities and finite parallel electron heat flux density is observed. The three simulations exhibit features of the Chew–Goldberger–Low theory, with the level of consistency increasing as the guide field strength increases. This explains the electron parallel temperature variations and the shape of the EVDFs observed along the separatrices. This work may provide insights into the understanding of electron heating and parallel heat flux density in E-REC observed in the turbulent magnetosheath.

79 ASTRONOMY AND ASTROPHYSICS↗

Energy demand reduction in the built environment using shallow geothermal integrated energy systems: Part II – Hybrid ground source heat pump for building heating

The research collection aims at finding the various possible opportunities for the effective integration of shallow geothermal energy (SGE) to decrease the energy demand in the built environment and to reduce emission associated with it. The direct utilization of SGE using a ground source heat pump (GSHP) has been reviewed in comprehensive review part I and part II. From the extensive review, we have found that the hybrid GSHP is needed to avoid ground thermal imbalance and peak demand. Hybrid GSHP can adopt various supplemental heat sources and sinks according to the local climatic conditions and the balance of energy demands. The primary focus on the integration of subsystems such as biomass, solar energy (PV, PVT, and collector), phase change material, micro gas turbine, and absorption heat pump with GSHP is presented for heating application. This comprehensive review part III highlights the recent research findings and a potential gap in hybrid GSHP for further research and developments

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Calculation of Critical Heat Flux Using an Inverse Heat Transfer Method to Support TREAT Experiment Analysis

Heat transfer between cladding and coolant during transient scenarios remains a critical area of uncertainty in understanding nuclear reactor safety. To advance the understanding of transient and accident scenarios involving critical heat flux (CHF), an in-pile experiment for the Transient Reactor Test (TREAT) facility at Idaho National Laboratory was developed. The experiment named CHF-Static Environment Rodlet Transient Test Apparatus (CHF-SERTTA), consists of a hollow borated stainless steel heater rod submerged in a static water pool which is heated via the (n, a) reaction in boron-10. This paper presents a novel inverse heat transfer method to determine CHF by using the optimization and uncertainty software DAKOTA to calibrate a RELAP5-3D model of CHF-SERTTA to temperature measurements obtained from a thermocouple welded to the surface of the rod.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Variable Conductance Heat Pipe Cooling of Stirling Convertor and General Purpose Heat Source

In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor. In a previous NASA SBIR Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for Stirling RPS. The operation of these VCHPs was demonstrated using Stirling heater head simulators and GPHS simulators. In the most recent effort, a sodium VCHP with a stainless steel envelope was designed, fabricated and tested at NASA Glenn Research Center (GRC) with a Stirling convertor for two concepts; one for the Advanced Stirling Radioisotope Generator (ASRG) back up cooling system and one for the Long-lived Venus Lander thermal management system. The VCHP is designed to activate and remove heat from the stopped convertor at a 19 degC temperature increase from the nominal vapor temperature. The 19 degC temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the Multi-Layer Insulation (MLI). In addition, the same backup cooling system can be applied to the Stirling convertor used for the refrigeration system of the Long-lived Venus Lander. The VCHP will allow the refrigeration system to: 1) rest during transit at a lower temperature than nominal; 2) pre-cool the modules to an even lower temperature before the entry in Venus atmosphere; 3) work at nominal temperature on Venus surface; 4) briefly stop multiple times on the Venus surface to allow scientific measurements. This paper presents the experimental results from integrating the VCHP with an operating Stirling convertor and describes the methodology used to achieve their successful combined operation.

Stirling Radioisotope Power System↗

Loop Heat Pipe Temperature Oscillation Induced by Gravity Assist and Reservoir Heating

The Laser Thermal Control System (LCTS) for the Advanced Topographic Laser Altimeter System (ATLAS) to be installed on NASA's Ice, Cloud, and Land Elevation Satellite (ICESat-2) consists of a constant conductance heat pipe and a loop heat pipe (LHP) with an associated radiator. During the recent thermal vacuum testing of the LTCS where the LHP condenser/radiator was placed in a vertical position above the evaporator and reservoir, it was found that the LHP reservoir control heater power requirement was much higher than the analytical model had predicted. Even with the control heater turned on continuously at its full power, the reservoir could not be maintained at its desired set point temperature. An investigation of the LHP behaviors found that the root cause of the problem was fluid flow and reservoir temperature oscillations, which led to persistent alternate forward and reversed flow along the liquid line and an imbalance between the vapor mass flow rate in the vapor line and liquid mass flow rate in the liquid line. The flow and temperature oscillations were caused by an interaction between gravity and reservoir heating, and were exacerbated by the large thermal mass of the instrument simulator which modulated the net heat load to the evaporator, and the vertical radiator/condenser which induced a variable gravitational pressure head. Furthermore, causes and effects of the contributing factors to flow and temperature oscillations intermingled.

Thermal Control Systems↗

Loop Heat Pipe Temperature Oscillation Induced by Gravity Assist and Reservoir Heating

The Laser Thermal Control System (LCTS) for the Advanced Topographic Laser Altimeter System (ATLAS) to be installed on NASA's Ice, Cloud, and Land Elevation Satellite (ICESat-2) consists of a constant conductance heat pipe and a loop heat pipe (LHP) with an associated radiator. During the recent thermal vacuum testing of the LTCS where the LHP condenser/radiator was placed in a vertical position above the evaporator and reservoir, it was found that the LHP reservoir control heater power requirement was much higher than the analytical model had predicted. Even with the control heater turned on continuously at its full power, the reservoir could not be maintained at its desired set point temperature. An investigation of the LHP behaviors found that the root cause of the problem was fluid flow and reservoir temperature oscillations, which led to persistent alternate forward and reversed flow along the liquid line and an imbalance between the vapor mass flow rate in the vapor line and liquid mass flow rate in the liquid line. The flow and temperature oscillations were caused by an interaction between gravity and reservoir heating, and were exacerbated by the large thermal mass of the instrument simulator which modulated the net heat load to the evaporator, and the vertical radiator/condenser which induced a variable gravitational pressure head. Furthermore, causes and effects of the contributing factors to flow and temperature oscillations intermingled.

0000↗

Evaluation of Contact Resistance and Fin Effectiveness of Enhanced, Brazed "Dogbone" Fin and Serpentine Tube Heat Exchangers for Air Conditioning and Heat Pump Applications

The energy consumption due to air conditioning is projected to increase by 1.3 and 4.5 times by 2050 compared to 2010 for members and non-members of the Organization of Economic Coordination and Development (OECD), respectively. Greenhouse Gas (GHG) emissions must be carefully managed to minimize their hazardous contribution to climate change. Air conditioners (AC) and heat pumps (HP) contribute with direct GHG emissions through systemic refrigerant leakage, which consequently degrades the system’s performance and therefore increases its indirect GHG emissions as well. To address this issue, the goals of new systems include minimizing leakage risk, using low global warming potential (GWP) refrigerants such as natural refrigerants, and increasing system efficiency. This paper presents part of the efforts in the development of a brazed “dogbone” fin to continuous serpentine tube heat exchanger (HX) for AC/HP applications. The main advantages of such technology are: 1) The potential to reduce 90% or more of the tube return-bends brazed joints compared to conventional tube-fin heat exchangers, thus minimizing leakage vulnerability, enabling the use of natural refrigerants like Propane and Ammonia that carry other concerning risks of flammability and toxicity ; and 2) The brazed fin to the tube joints should yield very low contact resistance. In order to quantify and estimate the impacts of contact resistance and fin effectiveness, a numerical-experimental study is investigated. The novel enhanced brazed “dog-bone” fin is compared to an equivalent pressure expanded fin. The results showed that the expanded fin has consistently greater effective heat transfer but greater contact resistance as well. Furthermore, the brazed fins have up to 20% lower pressure drop. The trade-off comparison shows that the thermal-hydraulic ratio between the two fins is equivalent for air velocities below 2m/s; for greater velocities, however, the expanded fin is favored since it has less fin efficiency penalty. For HVAC&R applications, the air velocities are typically low which makes the proposed technology competitive and a viable option in the pursuit of refrigerant leakage reduction.

30 DIRECT ENERGY CONVERSION↗

Heat Pumps and the Electrification of Heating

70 to 80% of building energy load in Alaska is heating. About 81% of residential heating is supplied via on-site combustion of fossil fuels. How can heat pumps provide heat energy from renewable sources?

Alaska↗

Disorder-induced heating as a mechanism for fast neutral gas heating in atmospheric pressure plasmas

Abstract Recent findings suggest that ions are strongly correlated in atmospheric pressure plasmas if the ionization fraction is sufficiently high ( ≳ 10 − 5 ). A consequence is that ionization causes disorder-induced heating (DIH), which triggers a significant rise in ion temperature on a picosecond timescale. This is followed by a rise in the neutral gas temperature on a longer timescale of up to nanoseconds due to ion–neutral temperature relaxation. The sequence of DIH and ion–neutral temperature relaxation suggests a new mechanism for ultrafast neutral gas heating. Previous work considered only the case of an instantaneous ionization pulse, whereas the ionization pulse extends over nanoseconds in many experiments. Here, molecular dynamics simulations are used to analyze the evolution of ion and neutral gas temperatures for a gradual ionization over several nanoseconds. The results are compared with published experimental results from a nanosecond pulsed discharge, showing good agreement with a measurement of fast neutral gas heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design Heating and Cooling Load Calculation Versus Building Load Simulation for Cold Climate Heat Pumps: Understanding the "Gap"

This report explores the differences between Manual J-equivalent block load calculations and building HVAC energy simulation results using EnergyPlus™ calculations when designing cold climate heat pump systems for residential use. This study will help HVAC researchers and advanced designers understand the impacts of oversizing heat pumps on home energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat conduction in an irregular magnetic field. Part 2. Heat transport as a measure of the effective non-integrable volume

Given the large anisotropy of transport processes in magnetized plasmas, the magnetic field structure can strongly impact heat diffusion: magnetic surfaces and cantori form barriers to transport while chaotic layers and island structures can degrade confinement. When a small but non-zero amount of perpendicular diffusion is included, the structure of the magnetic field becomes less important, allowing pressure gradients to be supported across chaotic regions and island chains. We introduce a metric for the effective volume over which the local parallel diffusion dominates based on the solution to the anisotropic heat diffusion equation. To validate this metric, we consider model fields with a single island chain and a strongly chaotic layer for which analytic predictions of the relative parallel and perpendicular transport can be made. We also analyse critically chaotic fields produced from different sets of perturbations, highlighting the impact of the mode number spectrum on the heat transport. Our results indicate that this metric coincides with the effective volume of non-integrability in the limit $\kappa _{\perp } \rightarrow 0$ , where $\kappa_{\perp}$ is the perpendicular diffusion coefficient. We propose that this metric be used to assess the impact of non-integrability on the heat transport in stellarator equilibria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of organized convection parameterization on the MJO and precipitation in E3SMv1. Part I: Mesoscale heating

Mesoscale organization of convection is typically not represented in global circulation models, and hence its influence on the global circulation is not accounted for. The heating component of a parameterization that represents the dynamical and physical effects of circulations associated with organized convection, referred to as the multiscale coherent structure parameterization (MCSP), is implemented in the Energy Exascale Earth System Model version 1 (E3SMv1). Numerical simulations are conducted to assess its impact on the simulated climate. Besides E3SMv1 simulations, we performed high-resolution (1 km) simulations using the Weather Research and Forecasting (WRF) Model to determine the temperature tendencies induced by mesoscale convective systems embedded in deep convection. We tuned the free parameters of the MCSP based on the WRF simulations. MCSP heating enhances Kevin wave spectra in E3SMv1, improves the representation of the Madden-Julian Oscillation, and impacts on mean precipitation that vary with locations and seasons, including a reduction of biases over the tropical Pacific.

Climate Modeling↗

X-ray free electron laser heating of water and gold at high static pressure

Probing of reactive materials such as H 2 O ices and fluids at the high pressures and temperatures of planetary interiors is limited by unwanted chemical reactions and confinement failure. Faster experiments can mitigate such issues, but the common approach of adiabatic compression limits the conditions achieved. This study demonstrates a fast experimental strategy for the creation and probing of selected extreme states using static compression coupled with ultrafast X-ray laser heating. Indirect X-ray heating of H 2 O through the use of a gold absorber is evidenced by sample melting inferred from textural changes in the H 2 O diffraction lines and inter-dispersion of gold and H 2 O melts. Coupled with numerical analysis of femtosecond energy absorption, thermal equilibration, and heat transfer, all evidence indicates that temperatures in excess of an electron volt have been reached in the H 2 O at high pressure. Even after repeated heating, samples stayed chemically unchanged from the starting material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Automated ICRF heating surrogate modeling via machine learning

This work introduces automated machine learning workflows that address critical bottlenecks in surrogate model development for Ion Cyclotron Range of Frequencies (ICRF) heating applications. The automated framework includes data analysis tools that transform raw datasets into actionable insights in seconds, replacing weeks of manual exploratory effort and ensuring consistent, reproducible dataset characterization. By integrating advanced hyperparameter optimization (HPO) methods including Bayesian optimization via BoTorch and Tree-structured Parzen Estimators (TPE), the framework significantly reduces model development time from weeks to hours, decreasing computational cost and required expertise, while enabling high-accuracy surrogate models. Compared to traditional hyperparameter scanning (HPS) techniques such as methodical, randomized, and grid searches, HPO methods achieve superior convergence and predictive performance, even when compared to already well-tuned reference models. On NSTX High Harmonic Fast Wave (HHFW) heating datasets, both Random Forest Regressor (RFR) and neural network surrogates demonstrate improved accuracy, achieving R 2 values beyond 0.97 and 0.98, respectively. The results show that while HPO gains are modest for robust architectures like RFR, they become essential for more sensitive models such as neural networks, highlighting the trade-offs across optimization strategies. Through automated workflows that eliminate manual hyperparameter tuning and require minimal ML expertise, this work enables widespread adoption of high-fidelity surrogate models across the fusion community for real-time plasma control, uncertainty quantification, rapid experimental scenario development, and integrated system optimization.

Sanchez-Villar, Alvaro [Princeton Plasma Physics L↗