Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “guidance document”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Guidance for Monitoring Passive Groundwater Remedies Over Extended Time Scales

Passive remediation can be appropriate where natural processes and actions such as institutional controls mitigate exposure to contaminated groundwater, achieving remedial action objectives and protectiveness of human health and the environment. Monitored natural attenuation (MNA) is a prevalent passive remediation strategy supported by a regulatory framework and monitoring design guidance. However, long-term passive remedies are usually selected in combination with at least one active remedy, such as source removal, in situ treatment, or pump-and-treat, functioning as a complementary method for achieving remediation objectives and meeting the applicable statutory and regulatory requirements. However, MNA and existing monitoring guidance primarily target situations where the remedial action objectives are met within a few decades. When time scales for passive remediation extend to many decades (50 years or more), a corresponding change in monitoring strategy is needed to adapt to the extended time scale. This document provides guidance for implementing an extended-scale monitoring (ESM) approach appropriate for long-duration passive remediation. Extended-scale is defined in this document with respect to time (i.e., a long duration of remediation) and a large enough physical scale such that downstream receptors will not be impacted within the remediation timeframe. ESM applies to slow-moving groundwater contaminant plumes and emphasizes monitoring primarily for potential exposure pathways. For this approach, the primary monitoring objective is to demonstrate that the plume diminishes before reaching the receptor zone or point of compliance and/or a receptor does not receive concentrations above the compliance limit. While the overall objectives of protecting human health and the environment are the same as for plumes where remediation can occur over a shorter time period, the time scales between decisions are longer and the dynamics of plume evolution are slower. To this end, a scenario-based strategy is described for different plume and source conditions, defining a containment and receptor zones. The containment zone is the area where the risk of exposure to groundwater contamination can be mitigated (e.g., through institutional controls) during the remediation time period. The receptor zone is defined as the area where exposure to groundwater contamination cannot be mitigated and compliance concentration standards must be met. Within the containment zone, slow plume migration may occur, leading to concentrations that exceed compliance standards. However, where distance to the receptor zone is large relative to plume migration and attenuation rate, this approach can be protective of the receptor zone. Selection of a long-duration passive remedy needs to be based on sufficient understanding of contaminant sources, hydrogeology, and contaminant plumes. A strong technical basis, supported by predictive analysis, is recommended to substantiate that contamination is expected to stay within the containment zone during the active remediation and attainment phase of the remedy, and diminish to meet compliance standards within the extended timeframe prior to reaching the receptor zone (e.g., many decades or even centuries). The ESM approach is based on verification of plume behavior and not on detailed plume dynamics. Monitoring is conducted to confirm expected behavior with an emphasis on exposure pathways to verify that plumes remain contained in areas where the protectiveness objectives can be met. ESM should not be adopted if there is significant risk of the plume extending beyond the containment zone. Given the slow movement within the containment zone, less frequent sampling is required relative to approaches used for conventional-scale remediation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Treatment of uncertainties associated with PRAs in risk-informed decision making (NUREG1855).

This document provides guidance on how to treat uncertainties associated with probabilistic risk assessment (PRA) in risk-informed decisionmaking. The objectives of this guidance include fostering an understanding of the uncertainties associated with PRA and their impact on the results of PRA and providing a pragmatic approach to addressing these uncertainties in the context of the decisionmaking. In implementing risk-informed decisionmaking, the U.S. Nuclear Regulatory Commission expects that appropriate consideration of uncertainty will be given in the analyses used to support the decision and in the interpretation of the findings of those analyses. To meet the objective of this document, it is necessary to understand the role that PRA results play in the context of the decision process. To define this context, this document provides an overview of the risk-informed decisionmaking process itself. With the context defined, this document describes the characteristics of a risk model and, in particular, a PRA. This description includes recognition that a PRA, being a probabilistic model, characterizes aleatory uncertainty that results from randomness associated with the events of the model. Because the focus of this document is epistemic uncertainty (i.e., uncertainties in the formulation of the PRA model), it provides guidance on identifying and describing the different types of sources of epistemic uncertainty and the different ways that they are treated. The different types of epistemic uncertainty are parameter, model, and completeness uncertainties. The final part of the guidance addresses the uncertainty in PRA results in the context of riskinformed decisionmaking and, in particular, the interpretation of the results of the uncertainty analysis when comparing PRA results with the acceptance criteria established for a specified application. In addition, guidance is provided for addressing completeness uncertainty in risk-informed decision making. Such consideration includes using a program of monitoring, feedback, and corrective action.

99 GENERAL AND MISCELLANEOUS↗

Guidebook for Limited Sample Probability of Detection (LS-POD) Demonstration for Signal-Response Nondestructive Evaluation (NDE) Methods

This document provides guidance for performing limited sample probability of detection (LS-POD) demonstration testing with smaller numbers of flawed specimens than the 29 required for the Point Estimate POD method referenced in NASA Standard 5009B. This document is specifically applicable to NASA programs and projects where NASA Special NDE methods are used to inspect fracture critical human spaceflight metallic hardware when the minimum number of flawed specimens required for the Point Estimate POD method referenced in NASA Standard 5009B (2019) are not available.

Limited Sample Probability of Detection↗

Screening-Level Ecological Risk Assessment Methods, Revision 3

This document provides guidance for screening-level assessments of potential adverse impacts to ecological resources from release of environmental contaminants at the Los Alamos National Laboratory (LANL or the Laboratory). The methods presented are based on two objectives, namely: to provide a basis for reaching consensus with regulators, managers, and other interested parties on how to conduct screening-level ecological risk investigations at the Laboratory; and to provide guidance for ecological risk assessors under the Environmental Programs (EP) Directorate. This guidance promotes consistency, rigor, and defensibility in ecological screening investigations and in reporting those investigation results. The purpose of the screening assessment is to provide information to the risk managers so informed riskmanagement decisions can be made. This document provides examples of recommendations and possible risk-management strategies.

54 ENVIRONMENTAL SCIENCES↗

UML and SOA Overview with Example Applications to the xLPR V.2 Project

This document provides guidance to xLPR model developers on how they can more effectively design and communicate the requirements of their modules to the xLPR Computational Group (CG) by using Unified Modeling Language (UML) and Service-Oriented Architectural (SOA) design principles. This document gives an overview on the use of UML and SOA design principles to aid the analysis, design and implementation of xLPR modules as GS external functions.

Klasky, Hilda B.↗

Guidance for Human Error Analysis (HEA)

NASA’s Human-Rating Requirements for Space Systems in NASA Procedural Requirements (NPR) 8705.2C requires Program Managers to conduct a human error analysis (HEA) for all mission phases. The purpose of the HEA is to enable programs to understand and manage potential catastrophic hazards that could be caused by human error, understand the relative risks and uncertainties within the system design, and influence decisions throughout the system lifecycle. This document provides guidance to NASA civil servants and contractors on how the Agency’s HEA requirement can be fulfilled.

Human Error Analysis; NASA Procedural Requirement;↗

First Magnetic Resonance Imaging-Guided Aortic Stenting and Cava Filter Placement Using a Polyetheretherketone-Based Magnetic Resonance Imaging-Compatible Guidewire in Swine: Proof of Concept

The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Guidebook for the Design and Analysis of a NASA Standard Nondestructive Evaluation (NDE) Probability of Detection (POD) Study

Purpose: This document provides guidance on the design and analysis of a NASA Standard nondestructive evaluation (NDE) probability of detection (POD) study. A Standard NDE flaw size is considered to be conservative such that most inspectors, trained and certified in the specific NDE method, are expected to provide at least 90/95 POD for that flaw size to inspect fracture-critical hardware. Scope: This document is specifically applicable to NASA Technical Standards that establish the NDE requirements for any NASA system or component, flight or ground, where fracture control and a quantitative demonstration of POD is a requirement, including NASA-STD-5009B, Nondestructive Evaluation Requirements for Fracture-Critical Metallic Components, and NASA-STD-5019A,Fracture Control Requirements for Spaceflight Hardware.

Probability of Detection↗

Criteria and Processes for the Certification of Non-Radioactive Hazardous and Non-Hazardous Wastes

This document details Lawrence Livermore National Laboratory's (LLNL) criteria and processes for determining if potentially volumetrically contaminated or potentially surface contaminated wastes are to be managed as material containing residual radioactivity or as non-radioactive. This document updates and replaces UCRL-AR-109662, Criteria and Procedures for the Certification of Nonradioactive Hazardous Waste (Reference 1), also known as 'The Moratorium', and follows the guidance found in the U.S. Department of Energy (DOE) document, Performance Objective for Certification of Non-Radioactive Hazardous Waste (Reference 2). The 1992 Moratorium document (UCRL-AR-109662) is three volumes and 703 pages. The first volume provides an overview of the certification process and lists the key radioanalytical methods and their associated Limits of Sensitivities. Volumes Two and Three contain supporting documents and include over 30 operating procedures, QA plans, training documents and organizational charts that describe the hazardous and radioactive waste management system in place in 1992. This current document is intended to update the previous Moratorium documents and to serve as the top-tier LLNL institutional Moratorium document. The 1992 Moratorium document was restricted to certification of Resource Conservation and Recovery Act (RCRA), State and Toxic Substances Control Act (TSCA) hazardous waste from Radioactive Material Management Areas (RMMA). This still remains the primary focus of the Moratorium; however, this document increases the scope to allow use of this methodology to certify other LLNL wastes and materials destined for off-site disposal, transfer, and re-use including non-hazardous wastes and wastes generated outside of RMMAs with the potential for DOE added radioactivity. The LLNL organization that authorizes off-site transfer/disposal of a material or waste stream is responsible for implementing the requirements of this document. The LLNL Radioactive and Hazardous Waste Management (RHWM) organization is responsible for the review and maintenance of this document. It should be noted that the DOE metal recycling moratorium is still in effect and is implemented as outlined in reference 17 when metals are being dispositioned for disposal/re-use/recycling off-site. This document follows the same methodology as described in the previously approved 1992 Moratorium document. Generator knowledge and certification are the primary means of characterization. Sampling and analysis are used when there is insufficient knowledge of a waste to determine if it contains added radioactivity. Table 1 (page 12) presents a list of LLNL's analytical methods for evaluating volumetrically contaminated waste and updates the reasonably achievable analytical-method-specific Minimum Detectable Concentrations (MDCs) for various matrices. Results from sampling and analysis are compared against the maximum MDCs for the given analytical method and the sample specific MDC to determine if the sample contains DOE added volumetric radioactivity. The evaluation of an item that has a physical form, and history of use, such that accessible surfaces may be potentially contaminated, is based on DOE Order 5400.5 (Reference 3), and its associated implementation guidance document DOE G 441.1-XX, Control and Release of Property with Residual Radioactive Material (Reference 4). The guidance document was made available for use via DOE Memorandum (Reference 5). Waste and materials containing residual radioactivity transferred off-site must meet the receiving facilities Waste Acceptance Criteria (if applicable) and be in compliance with other applicable federal or state requirements.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Guidebook for Assessing Similarity and Implementing Empirical Transfer Functions for Probability of Detection (POD) Demonstrations for Signal Based Nondestructive Evaluation (NDE) Methods

This document provides guidance for assessing similarity relative to nondestructive evaluation (NDE) detectability based on Probability of Detection demonstrations when comparing different NDE inspection situations. Differences in inspection situations addressed by the similarity assessment methodology herein can include differences in the component being inspected, and differences in the conditions for the inspection. Additional differences in the inspection situation relative to differences in the method or procedure are not addressed in this document but can be assessed using NDE calibration or instrument standardization specimens.

Probability of Detection↗

UMP Reference Language - Examples

This document provides example language for referencing the use of Uniform Methods Project (UMP) protocols followed by examples of language that is currently in use, which helps the reader understand when and how the protocols are used and ensures consistent citation of relevant UMP protocols.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Radiology and Enterprise Medical Imaging Extensions (REMIX)

Radiology and Enterprise Medical Imaging Extensions (REMIX) is a platform originally designed to both support the medical imaging-driven clinical and clinical research operational needs of Department of Radiology of The Ohio State University Wexner Medical Center. REMIX accommodates the storage and handling of “big imaging data,” as needed for large multi-disciplinary cancer-focused programs. The evolving REMIX platform contains an array of integrated tools/software packages for the following: (1) server and storage management; (2) image reconstruction; (3) digital pathology; (4) de-identification; (5) business intelligence; (6) texture analysis; and (7) artificial intelligence. These capabilities, along with documentation and guidance, explaining how to interact with a commercial system (e.g., PACS, EHR, commercial database) that currently exists in clinical environments, are to be made freely available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Guide to Performing Computational Analysis of Criticality Accident Alarm Systems

This document provides guidance on performing computational analyses of Criticality Accident Alarm Systems (CAAS). A brief overview of ANSI/ANS-8.3-1997 (R2012), the standard that the United States Department of Energy uses to guide the placement of CAAS detectors, is provided with a focus on the parts of the standard that are most applicable to calculating CAAS detector responses and evaluating CAAS detector coverage. This is followed by a brief discussion of how CAAS detector response calculations differ from eigenvalue calculations that criticality safety practitioners perform regularly. The remainder of the document provides computational examples of how to determine the minimum accident of concern according to ANSI/ANS-8.3-1997 (R2012), how to calculate the response of a CAAS detector due to a specific criticality accident, and how to evaluate the coverage of a CAAS detector for criticality accidents. These practical examples are solved applying SCALE 6.1 and MCNP5, but the methodologies can be applied to other radiation transport codes with similar capabilities, including deterministic codes.

Miller, Thomas Martin↗

Guide to Developing Energy Services Interfaces

This document provides guidance to develop communications interfaces that are highly interoperable and adhere to a set of energy services interface (ESI) principles. It can be applied in the context of information and communications technology interface standards and implementation profiles that enable the integration of a facility with responsive distributed energy resources (DER) into an electric power system consistent with the fundamental ESI principles. In this context, a DER facility may consist of a single DER with a communicating controller or may be as complex as a microgrid campus with several buildings and many DERs. This document is not a technical interface standard, but the requirements described can be used to check that existing, augmented, or new interface standards meet the interoperability requirements of the ESI concept. In this way, this guide for the ESI specification can support future advancements in developing interoperability standards and implementation profiles. The intended audience for this document is DER integration practitioners and ecosystem groups that are in the business of developing and implementing communications interfaces for DER integration. It is intended that these groups apply the information and processes in this document to develop communications standards and implementation profiles that are consistent with fundamental ESI principles.

2030.5↗

Energy Savings Modeling and Inspection Guidelines for Commercial Building Federal Tax Deductions for Buildings in 2016 and Later

This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code (IRC) enacted in Section 1331 of the 2005 Energy Policy Act (EPAct) of 2005, noted in Internal Revenue Service (IRS) Notices 2006-52 (IRS 2006), 2008-40 (IRS 2008) and 2012-26 (IRS 2012), and updated by the Protecting Americans from Tax Hikes (PATH) Act of 2015. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning (HVAC); and service hot water (SHW) systems. This document applies to buildings placed in service on or after January 1, 2016.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ANOPP2 User's Manual: Version 1.2

This manual documents the Aircraft NOise Prediction Program 2 (ANOPP2). ANOPP2 is a toolkit that includes a framework, noise prediction methods, and peripheral software to aid a user in predicting and understanding aircraft noise. This manual includes an explanation of the overall design and structure of ANOPP2, including a brief introduction to aircraft noise prediction and the ANOPP2 background, philosophy, and architecture. The concept of nested acoustic data surfaces and its application to a mixed-fidelity noise prediction are presented. The structure and usage of ANOPP2, which includes the communication between the user, the ANOPP2 framework, and noise prediction methods, are presented for two scenarios: wind-tunnel and flight. These scenarios serve to provide the user with guidance and documentation references for performing a noise prediction using ANOPP2.

Lopes, L. V.↗

New Coaxial Transseptal Needle for Creation of Atrial Septal Defects in Adult Sheep

Objectives: To introduce a new transseptal (TS) needle assembled in our laboratory-the coaxial TS (CTS) needle-and describe our experience with it in creating experimental atrial septal defects (ASD) in adult sheep.BackgroundWith commercially available TS needles, we were not able to consistently perform TS puncture at the fossa ovalis in adult sheep.Material and MethodsTen adult sheep with a mean weight of 63.5 kg were used. The CTS needle consists of four components: a 9F Teflon catheter, a 14-gauge blunt curved-tip metal cannula, a 4F tapered catheter, and a 20-gauge open needle. A transjugular 5F pigtail catheter was used to display the septal anatomy by angiocardiography and was left in place to mark the level of the fossa ovalis. The septum was then probed by a transfemoral 5F curved-tip end-hole catheter. The CTS needle was aligned with the tip of the transjugular catheter, and the TS puncture was performed under fluoroscopic guidance. After documenting a left atrial position, a balloon angioplasty catheter was used for creation of the ASD. Results: A small patent foramen ovale was discovered by septal probing in one sheep. All sheep underwent successful TS punctures without complications. The ASD size ranged from 13 to 15 mm. In eight sheep, the ASD was in fossa ovalis. In the first two sheep where the needle was not well aligned with the marking catheter, the ASD was in the septum secundum. No damage to the atrial or other heart structures was found at necropsy. Conclusion: The CTS needle is a suitable needle for TS puncture and ASD creation in adult sheep. Proper alignment of the CTS needle with a catheter marking the fossa ovalis is essential for successful puncture.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Iraq liquid radioactive waste tanks maintenance and monitoring program plan.

The purpose of this report is to develop a project management plan for maintaining and monitoring liquid radioactive waste tanks at Iraq's Al-Tuwaitha Nuclear Research Center. Based on information from several sources, the Al-Tuwaitha site has approximately 30 waste tanks that contain varying amounts of liquid or sludge radioactive waste. All of the tanks have been non-operational for over 20 years and most have limited characterization. The program plan embodied in this document provides guidance on conducting radiological surveys, posting radiation control areas and controlling access, performing tank hazard assessments to remove debris and gain access, and conducting routine tank inspections. This program plan provides general advice on how to sample and characterize tank contents, and how to prioritize tanks for soil sampling and borehole monitoring.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗