Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Dynamic Earth Energy Storage: Terawatt-Year, Grid-Scale Energy Storage using Planet Earth as a Thermal Battery (GeoTES): Seedling Project Final Report

Grid-scale energy storage has been identified as a needed technology to support the continued build-out of intermittent renewable energy resources. As of April 2017, the U.S. had approximately 24.2 GW of energy storage on line, compared to 1,081 GW of installed generation capacity (Litynski et al. 2006, Hellstrom 2003). This represents a large shortfall of the storage needed to stabilize the U.S. grids with the rising penetration of renewable energy. Our team proposed to address this shortfall through the storage of excess energy as geothermal brine in deep geologic formations. This concept, known as geologic thermal energy storage (GeoTES), relies on the storage of thermal energy in geologic formations for recovery and use in large-scale direct use geothermal applications. As such, GeoTES has the potential to play a significant role in meeting the energy storage shortfall in the coming decades by assisting with peak demand ramping, easing stress on transmission, providing regional storage to support sustainable direct use geothermal applications, and providing a variety of grid stabilization benefits due to renewable outages or inaccurate forecasting and rotor stability.

15 GEOTHERMAL ENERGY↗

AC and DC Hybrid Distribution Grids with Solar Integration: Architecture, Stabilization and Cost Assessment

In this project, a holistic analysis of architecture, stabilization, and cost/efficiency analysis in hybrid AC and DC distribution grids are conducted. Particularly, versatile and cost-efficient multiport converters are developed to not only integrate solar sources and other DERs in DC grids, but also facilitate the interactive operation of DC sub-grids and conventional AC distribution grids. Meanwhile, a universal and extended impedance-based stabilization approach with a decentralized and adaptive virtual impedance loop is developed in hybrid AC and DC distribution grids, which comprehensively covers the active stabilization of DC sections, AC sections, and interface inverters interlinking both AC and DC sections. Furthermore, to quantitatively evaluate the cost and efficiency of hybrid AC and DC distribution grids and quantify the improvement of hybrid AC and DC grids over conventional pure AC grids, the project team develops an alpha-version tool to monitor and calculate the efficiency and cost of the DC, AC, or hybrid AC and DC grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantitative Small-Signal Stability Analysis of Grid-Forming Inverters in Large-Scale Power Systems

In this paper, the challenges induced by the integration of inverter-based resources (IBRs) into existing power systems are discussed. Although the grid-forming (GFM) control has been used to enhance system performance in multiple sections of electric power systems (e.g., transmission and distribution systems, microgrids, among others), the coupling mechanism between GFM inverter and various types of other components in modern power systems should be clearly explored. Existing analyses mainly focus on qualitative investigations that verify the effectiveness of deploying GFM inverters for stability enhancement. A holistic system-level quantitative analysis is still missing to verify the detailed benefits of GFM inverters and their interactions with other generation units (e.g., synchronous generators [SGs], conventional grid-following [GFL] inverters, synchronous condensers, among others). To fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established along with the customized power flow analysis for varying steady-state operating points. Further, a quantitative method is proposed to identify the impacts of GFM inverters on system performance with an emphasis on a quantifiable stability margin and a complete modal analysis at the system level. Finally, a realistic test system is used to verify the proposed approach.

grid-following↗

Large-Signal Stability Improvement of Parallel Grid-Forming Inverter-Driven Black Start: Preprint

With the rapid increase of inverter-based resources in modern grids, advanced grid-forming (GFM) inverter capa- bilities, such as system restoration and operation under faults, are urgently needed to realize power electronics-dominant grids at scale. One such capability is inverter-driven black start using GFM inverters. This paper analyzes the ability of two recently proposed advanced GFM controls to help GFM inverters sustain system-wide, off-nominal conditions and remain synchronized until they can overcome the momentary overloading as more GFMs join the process without generator sequence coordination or communications and finally stabilize the grid. Through an extensive set of 1,200 full-order electromagnetic transient simu- lations, we evaluate the black-start process while employing the various GFM inverter controls. The results show that the GFM current limiter and primary control have a significant impact on the stability of the system during dynamic operating conditions and thus impact the success of inverter-driven system restoration.

current limit↗

Type 5 Wind Turbine Technology: How Synchronised, Synchronous Generation Avoids Uncertainties About Inverter Interoperability under IEEE 2800:2022

Degradation of system strength because of inverter-based resources (IBRs) is a major concern facing the zero-carbon transition. A new standard released this year, IEEE Standard 2800, attempts to codify the relationship between IBRs and the Transmission System Operator (TSO). It is apparent from IEEE 2800:2022 that there remain fundamental problems with quantifying whether source impedance (the measure of "system strength" with which the standard is concerned) will present a problem for allowing an IBR to connect. This is "because of complex interdependencies between IBR and power system characteristics". So developers are increasingly required to adopt mitigation options such as adding synchronous condensers or curtailing IBRs. A proven Type 5 (synchronous) wind turbine exists and has been running at 0.5 MW scale in a 46 MW wind farm in New Zealand since 2006 and eight turbines in Scotland since 2013. The US National Renewable Energy Laboratory (NREL) is conducting a study of the impacts on grid reliability, stability, and resilience of Type 5 wind turbines. The project has both simulation and testing tasks and will result in proposing a variable generation solution that will help system operators and utilities address all reliability and most resilience challenges in the evolving grid.

grid stability↗

IEEE 1547-2018 Based Interoperable PV Inverter with Advanced Grid-Support Functions

Grid integration of photovoltaic (PV) inverters has been increasing in the past decade. As a result of the uncertainties introduced with high penetrations of PV, better monitoring and control of the PV inverters becomes crucial for improving overall system stability. This paper focuses on the communications capability of the inverter controller and on enabling interoperability. Multiple standards are available to enable interoperability in PV inverters. In this paper, an interoperable controller, enabled by Distributed Network Protocol 3 (DNP3) communications protocols, is developed for a grid-connected, three-phase PV inverter. The DNP3 server for the PV inverter is programmed on the real-time layer of the field-programmable gate array (FPGA)-based inverter controller. Set points for advanced inverter control functions, such as volt/VAr curves, ride-through curves, are sent from a DNP3 client, a simulated distribution management system application, to the PV inverter through DNP3. This communications capability of the inverter controller is validated using a controller-hardware-in-the-loop experimental setup. The code developed to achieve the interoperability is available in the public domain through open-source software licensing. This interoperability will enable smoother grid integration of smart PV inverters with advanced grid-support functions as well as allow better monitoring and control of PV inverters for grid stability.

14 SOLAR ENERGY↗

Demonstrating Advanced Nuclear Energy Solutions for Net Zero

Background/Objectives. The aggressive goals being set by nation states, communities, and private industry for decarbonization of grid electricity, industrial heat sources, and transportation around the world are imperative to mitigating the devastating effects that we are seeing from climate change. Although many of these goals focus on accomplishments by 2035 or 2050, the decisions that we make today won’t just impact the landscape of energy systems for the next 20 or 30 years—they will shape the world’s environment for centuries to come. That means that we can’t just focus on technologies that will get us to 2050, but technologies that will withstand our energy demands over that long-ranging future. Success will require us to utilize all of the clean energy resources that we have available to meet demands for electricity, heat, and steam, and we will need energy carriers such as hydrogen that do not emit additional greenhouse gases at the point of use. Nuclear energy, ranging from technologies in service today to advanced, higher temperature and modular systems that will be in service this decade, will provide a robust complement to renewable energy resources that operate variably. Researchers across the U.S. Department of Energy laboratory complex are working to advance multiple aspects of these clean energy solutions, with many focusing on integrated energy system solutions that leverage all available clean energy assets to meet wide-ranging energy demands. Approach/Activities. Nuclear energy is a proven, zero-emission option during operation that can provide consistent, dispatchable power to meet electricity demands while also providing high-quality heat that can meet energy demands beyond the electricity sector. Energy system design should seek to maximize these assets. As a dispatchable energy source with a small land utilization footprint, nuclear energy can be collocated with renewable resources, and the smaller systems that will be deployed this decade (ranging from a few megawatts to hundreds of megawatts) can be installed right where that energy is needed. Integrated nuclear and renewable systems will enhance power grid reliability and resilience, and they will help stabilize the grid through their increasingly flexible operation. Licensing, installation, and broad adoption of these advanced nuclear energy systems are expected to progress significantly in the 2020s, but this may be longer than desired by some stakeholders wishing to implement impactful clean energy decisions today. However, one must recall that nuclear energy systems will operate for 80 or more years, as is being demonstrated by current fleet nuclear systems. The nuclear community is extremely thorough in reviewing these systems with regard to safety and security; these efforts ensure that the deployed systems will continue to provide reliable, resilient energy over that operational lifetime. That investment of time up front will ensure that we can support energy demands over the centuries to come. While advanced nuclear technologies move through this process, communities and private industry may choose to install renewable generation systems that can later be coupled to the complementary nuclear systems as they become available—thus moving closer to the net zero goals in the near term. Choosing technologies and deployment configurations that allow small modular nuclear powerhouses to be added to these “energy parks” as they become available will ensure that advanced technologies can be readily adopted to support growing demands for clean energy. Results/Lessons Learned. The primary focus of integrated energy systems (IES) research is to assess the technical and economic potential of novel multi-input, multioutput solutions that are expected to enhance energy system flexibility, reliability, and resilience as we pursue a clean energy transition. Various energy applications and product streams beyond electricity are being evaluated, ranging from generation of potable water to production of hydrogen, fertilizers, synthetic fuels, and various chemicals. In early FY23 Idaho National Laboratory (INL) will commission thermal energy generation systems that emulate nuclear fission energy input using electric heating and will allow for integrated system testing with thermal energy storage, hydrogen production via high temperature electrolysis (HTE), and power systems hardware to demonstrate operation of a clean energy park within a microgrid or larger grid infrastructure, supporting up to 450 kW of heat input via electric heating and demonstrating operation of HTE systems at the multi-hundred kW scale. This presentation will highlight the wide array of RD&D being conducted at INL and partner laboratories to develop and deploy nuclear and renewable-based IES that will be key to achieving our net zero goals, including both computational and experimental demonstrations. By working with key collaborators in industry, analytical st

08 HYDROGEN↗

An adaptive DC-bus stabilizer for single-phase grid-connected renewable energy source system

This paper proposes an adaptive DC-bus stabilizer for single-phase grid-connected voltage source converter (VSC) with small-scale renewable energy integration. To enhance converter's power density, the conventional active power decoupling (APD) techniques were adopted to reduce the DC capacitance by compensating the inherent second-order harmonic power ripples in the single-phase VSC. However, it would potentially make the DC voltage vulnerable to transient power ripples, which is a critical issue for the grid-connected renewable energy source (RES) system during grid faults. The proposed DC-bus stabilizer can not only compensate the second-order harmonic power ripples at normal operation, but also enhance the fault ride-through capability of the converter. The circuit topology and its corresponding control strategy are presented, and then simulation results are provided to demonstrate the feasibility and validity of the proposed DC-bus stabilizer under normal operation and grid fault condition.

Zeng, Rong↗

Grid Integration of Offshore Wind Power: Standards, Control, Power Quality and Transmission

Offshore wind is expected to be a major player in the global efforts toward decarbonization, leading to exceptional changes in modern power systems. Understanding the impacts and capabilities of the relatively new and uniquely positioned assets in grids with high integration levels of inverter-based resources, however, is lacking, raising concerns about grid reliability, stability, power quality, and resilience, with the absence of updated grid codes to guide the massive deployment of offshore wind. To help fill the gap, this paper presents an overview of the state-of-the-art technologies of offshore wind power grid integration. First, the paper investigates the most current grid requirements for wind power plant integration, based on a harmonized European Network of Transmission System Operators (ENTSO-E) framework and notable international standards, and it illuminates future directions. The paper discusses the wind turbine and wind power plant control strategies, and new control approaches, such as grid-forming control, are presented in detail. The paper reviews recent research on the ancillary services that offshore wind power plants can potentially provide, which, when harmonized, will not only comply with regulations but also improve the value of the asset. The paper explores topics of wind power plant harmonics, reviewing the latest standards in detail and outlining mitigation methods. The paper also presents stability analysis methods for wind power plants, with discussions centered on validity and computational efficiency. Finally, the paper discusses wind power plant transmission solutions, with a focus on high-voltage direct-current topologies and controls.

17 WIND ENERGY↗

Ultra-Large-Scale Power System Control and Coordination Architecture: A Strategic Framework for Integrating Advanced Grid Functionality

Electric power grids are being stressed by integration of intermittent renewable resources and significant adoption of distributed energy resources. The complexity of the grid is growing rapidly as we attempt to support technical, business, and societal goals for which power grids were not originally designed. Today, we largely take stability of the grid for granted. Stability could significantly degrade or collapse because of new dynamics introduced to the grid, and because the emerging extreme complexity makes traditional control analysis intractable, so that grid behavior is more unpredictable than in the past. This paper describes emerging issues in grid control and provides reasons why the present path of grid control evolution is problematic and presents an ultra-large scale framework for grid control that can solve today’s problems and those expected over the next 30 years. Failure to address these issues in the short term will result in rapidly escalating system deployment and maintenance costs, potential stranded assets related to replacement of the “ad hoc” systems, along with substantial operational risks that are unacceptable under current utility and regulatory practices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rapid Aero Modeling of a Lift+Cruise UAM Configuration for Stability and Control Using Overset Grid CFD

This talk will address some aspects of an effort to develop both static and dynamic stability and control derivatives of a generic Lift+Cruise Urban Air Mobility vehicle. In particular, the use of NASA overset grid CFD packages OVERFLOW and Chimera Grid Tools allowed for rapid grid and solution generation while varying many database factors. Approach details include coarse gridding and control effectors, rotor disk modeling, convergence evaluation, and parallel execution on a midrange compute resource. A brief *description of the Rapid Aero Modeling (RAM) approach, including design of experiments and response surface modeling, will be given, and recent simulations of powered and unpowered dynamic multisine maneuvers will be presented.

Overset Grid CFD↗

Off-policy deep reinforcement learning with automatic entropy adjustment for adaptive online grid emergency control

Electric overloading conditions and contingencies put modern power systems at risk of voltage collapse and blackouts. Load shedding is crucial to maintain voltage stability for grid emergency control. However, the rule- or model-based schemes rely on accurate dynamic system models and face considerable challenges in adapting to various operating conditions and uncertain event occurrences. Here, to address these issues, this paper proposes a novel deep reinforcement learning (DRL)-based voltage stability control algorithm with automatic entropy adjustment (AEA) for grid emergency control. Various dynamic network components for complex system operations are modeled to construct the DRL environment. An off-policy soft actor-critic architecture is developed to maximize the expected reward and policy entropy simultaneously. The AEA mechanism is proposed to facilitate the policy maximum entropy procedure, and the proposed method can automatically provide effective discrete and continuous actions against various fault scenarios. Our approach accomplishes high sampling efficiency, scalability, and auto-adaptivity of the control policies under high uncertainties. Comparative studies with the existing DRL-based control methods in IEEE benchmarks indicate salient performance improvement of the proposed method for dynamic system emergency control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comparative Study of Two Widely Used Grid-Forming Droop Controls on Microgrid Small Signal Stability

Throughout history, two similar grid-forming droop controls are widely reported in literature—the single-and multi-loop droop controls. Although being very similar, the authors find that the dynamic performance and stability characteristics of each control method are very different in a microgrid. Compared with single-loop droop control, the multi-loop droop control is prone to be less damped and loses stability more easily under some circumstances. This paper provides a novel insight into the different dynamic responses of the two basic controls. It points out that the two similar controls adjust the angular frequency and voltage magnitude at different locations within the inverter, resulting in different coupling reactances that impact the dynamic response and stability of microgrids differently. The use of single-loop droop control results in a larger coupling reactance, which helps to improve dynamic response and stability. This novel insight is verified through full-order small signal analysis, offline electromagnetic transient simulation, and real-time hardware-in-the-loop simulation experiments. Results show that the microgrid has a larger small signal stability boundary when using single-loop droop control, and this difference increases as the value of an inverter’s inner filter inductance increases.

42 ENGINEERING↗

Experimental Evaluation of PV Inverter Anti-Islanding with Grid Support Functions in Multi-Inverter Island Scenarios

As PV and other DER systems are connected to the grid at increased penetration levels, island detection may become more challenging for two reasons: 1.) In islands containing many DERs, active inverter-based anti-islanding methods may have more difficulty detecting islands because each individual inverter's efforts to detect the island may be interfered with by the other inverters in the island. 2.) The increasing numbers of DERs are leading to new requirements that DERs ride through grid disturbances and even actively try to regulate grid voltage and frequency back towards nominal operating conditions. These new grid support requirements may directly or indirectly interfere with anti-islanding controls. This report describes a series of tests designed to examine the impacts of both grid support functions and multi-inverter islands on anti-islanding effectiveness. Crucially, the multi-inverter anti-islanding tests described in this report examine scenarios with multiple inverters connected to multiple different points on the grid. While this so-called 'solar subdivision' scenario has been examined to some extent through simulation, this is the first known work to test it using hardware inverters. This was accomplished through the use of power hardware-in-the-loop (PHIL) simulation, which allows the hardware inverters to be connected to a real-time transient simulation of an electric power system that can be easily reconfigured to test various distribution circuit scenarios. The anti-islanding test design was a modified version of the unintentional islanding test in IEEE Standard 1547.1, which creates a balanced, resonant island with the intent of creating a highly challenging condition for island detection. Three common, commercially available single-phase PV inverters from three different manufacturers were tested. The first part of this work examined each inverter individually using a series of pure hardware resistive-inductive-capacitive (RLC) resonant load based anti-islanding tests to determine the worst-case configuration of grid support functions for each inverter. A grid support function is a function an inverter performs to help stabilize the grid or drive the grid back towards its nominal operating point. The four grid support functions examined here were voltage ride-through, frequency ride-through, Volt-VAr control, and frequency-Watt control. The worst-case grid support configuration was defined as the configuration that led to the maximum island duration (or run-on time, ROT) out of 50 tests of each inverter. For each of the three inverters, it was observed that maximum ROT increased when voltage and frequency ride-through were activated. No conclusive evidence was found that Volt-VAr control or frequency-Watt control increased maximum ROT. Over all single-inverter test cases, the maximum ROT was 711 ms, well below the two-second limit currently imposed by IEEE Standard 1547-2003. A subsequent series of 244 experiments tested all three inverters simultaneously in the same island. These tests again used a procedure based on the IEEE 1547.1 unintentional islanding test to create a difficult-to-detect island condition. For these tests, which used the two worst-case grid support function configurations from the single-inverter tests, the inverters were connected to a variety of island circuit topologies designed to represent the variety of multiple-inverter islands that may occur on real distribution circuits. The interconnecting circuits and the resonant island load itself were represented in the real-time PHIL model. PHIL techniques similar to those employed here have been previously used and validated for anti-islanding tests, and the PHIL resonant load model used in this test was successfully validated by comparing single-inverter PHIL tests to conventional tests using an RLC load bank.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient Stability-Enhancing Method for Grid-Forming Inverters Under Current Limiting

The primary controller of a grid-forming (GFM) inverter governs the internal reference voltage and angle, which enables the inverter to naturally synchronize and share power with the connected grid; however, during disturbances on the grid caused by, e.g., line faults, overloading, or frequency and phase shifts, a GFM inverter can be pushed into a current-limited operation to protect the device against thermal damage. This can lead to a windup of the internal reference frequency generated by the primary controller and cause a total loss of synchronism with the grid. Here, to make the primary controller of GFM inverters more robust against transient instability, this paper proposes a method that manipulates the reference signals governed by the primary controller by introducing the concept of fictitious power. The fictitious power counteracts the integrator windup in the primary controller, which enables the current-limited inverter to conceive a stable operating point. This method is benchmarked against five state-of-the-art GFM inverter stabilization methods to evaluate its stability-enhancing performance. Full-order electromagnetic-transient simulations and experimental results of a hardware inverter test setup validate the benefits of the method to improve the transient stability of GFM inverters in the face of grid disturbances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On Stability of PQ-Controlled Grid-Following and Droop-Control Grid-Forming Inverters

In this paper, the nonlinearity impacts of PQ-control schemes and LCL filter parameter variations on the stability of grid-interactive inverters are studied under weak grid conditions. This work demonstrates that the control nonlinearity and parameter variations can cause unexpected instability at low power levels. This instability issue in the nominal operating range may occur under specific control parameters due to the shift of the low-frequency eigenvalues of PQ-controlled inverters. A full-order small-signal model for PQ-controlled inverters is applied to analyze this instability issue. Furthermore, the impacts of the droop coefficients on the stability of the droop-controlled grid-forming inverter are also investigated using the closed-loop inverter model. The findings are experimentally verified using a small-scale two-level 208 V, 5 kVA inverter feeding a 12 kW NHR 9410 power grid emulator and a hardware setup of a microgrid fed by two 5 kVA 208V inverters.

Hossen, Tareq↗

Mitigating Voltage Instability in the Saudi Grid for a Decarbonized, Fully Solar Power System

Lately, solar photovoltaic (PV) has received significant interest due to its economic and environmental benefits. As the integration of renewable energy sources (RES) increases into existing power grids, challenges such as the decrease in short circuit ratio (SCR) are introduced. Here, this paper investigates a case study of the Saudi power grid, examining the voltage stability as the grid transitions from traditional power generation to 100% penetration of solar PV gradually. Moreover, the paper explores the relationship between the increase in solar penetration and the potential effects on the short circuit MVA (SCMVA), which could significantly impact the overall SCR of the system. To meet the North American Electric Reliability Corporation (NERC) recommendation of maintaining SCR at a particular level, synchronous condensers (SC)s were integrated into the grid. The effectiveness of utilizing SCs to maintain the system voltage at optimal levels in a fully solar grid is also considered. In addition, this paper covers the weak grid analysis via utilizing the Newton-Raphson load flow method, along with PV and QV curve analyses. The purpose behind that is to determine weak bus locations in need of voltage improvements, and to meet the amount of reactive power to be injected. Finally, the amount of power being delivered by SCs will be added progressively in three scenarios to show the enhancements on SCR more precisely.

24 POWER TRANSMISSION AND DISTRIBUTION↗