Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fringe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A grating-based single-shot x-ray phase contrast and diffraction method for in vivo imaging

Purpose: The purpose of this study is to develop a single-shot version of the grating-based phase contrast x-ray imaging method and demonstrate its capability of in vivo animal imaging. Here, the authors describe the principle and experimental results. They show the source of artifacts in the phase contrast signal and optimal designs that minimize them. They also discuss its current limitations and ways to overcome them. Methods: A single lead grid was inserted midway between an x-ray tube and an x-ray camera in the planar radiography setting. The grid acted as a transmission grating and cast periodic dark fringes on the camera. The camera had sufficient spatial resolution to resolve the fringes. Refraction and diffraction in the imaged object manifested as position shifts and amplitude attenuation of the fringes, respectively. In order to quantify these changes precisely without imposing a fixed geometric relationship between the camera pixel array and the fringes, a spatial harmonic method in the Fourier domain was developed. The level of the differential phase (refraction) contrast as a function of hardware specifications and device geometry was derived and used to guide the optimal placement of the grid and object. Both ex vivo and in vivo images of rodent extremities were collected to demonstrate the capability of the method. The exposure time using a 50 W tube was 28 s. Results: Differential phase contrast images of glass beads acquired at various grid and object positions confirmed theoretical predictions of how phase contrast and extraneous artifacts vary with the device geometry. In anesthetized rats, a single exposure yielded artifact-free images of absorption, differential phase contrast, and diffraction. Differential phase contrast was strongest at bone-soft tissue interfaces, while diffraction was strongest in bone. Conclusions: The spatial harmonic method allowed us to obtain absorption, differential phase contrast, and diffraction images, all from a single raw image and is feasible in live animals. Because the sensitivity of the method scales with the density of the gratings, custom microfabricated gratings should be superior to off-the-shelf lead grids.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-speed real-time 3D shape measurement based on adaptive depth constraint

Stereo phase unwrapping (SPU) has been increasingly applied to high-speed real-time fringe projection profilometry (FPP) because it can retrieve the absolute phase or matching points in a stereo FPP system without projecting or acquiring additional fringe patterns. Based on a pre-defined measurement volume, artificial maximum/minimum phase maps can be created solely using geometric constraints of the FPP system, permitting phase unwrapping on a pixel-by-pixel basis. However, when high-frequency fringes are used, the phase ambiguities will increase which makes SPU unreliable. Several auxiliary techniques have been proposed to enhance the robustness of SPU, but their flexibility still needs to be improved. In this paper, we proposed an adaptive depth constraint (ADC) approach for high-speed real-time 3D shape measurement, where the measurement depth volume for geometric constraints is adaptively updated according to the current reconstructed geometry. By utilizing the spatio-temporal correlation of moving objects under measurement, a customized and tighter depth constraint can be defined, which helps enhance the robustness of SPU over a large measurement volume. Besides, two complementary techniques, including simplified left-right consistency check and feedback mechanism based on valid area, are introduced to further increase the robustness and flexibility of the ADC. Furthermore, experimental results demonstrate the success of our proposed SPU approach in recovering absolute 3D geometries of both simple and complicated objects with only three phase-shifted fringe images.

42 ENGINEERING↗

Validating Laser-Induced Birefringence Theory with Plasma Interferometry

Intense laser beams crossing paths in plasma is theorized to induce birefringence in the medium, resulting from density and refractive index modulations that affect the polarization of incoming light. The goal of the associated experiment, conducted on Janus at Lawrence Livermore’s Jupiter Laser Facility, was to create a tunable laser-plasma waveplate to verify the relationship between dephasing angle and beam intensity, plasma density, plasma temperature, and interaction length. Interferometry analysis of the plasma channel was performed to obtain a density map and to constrain temperature measured from Thomson scattering. Various analysis techniques, including Fast Fourier transform (FFT) and two variations of fringe-counting, were tried because interferograms captured in this experiment contained unusual features such as fringe discontinuity at channel edges, saddle points, and islands. The chosen method is flexible, semi-automated, and uses a fringe tracking algorithm on a reduced image of pre-traced synthetic fringes. Ultimately, a maximum dephasing angle of 49.6° was achieved using a 1200 μm interaction length, and the experimental results appear to agree with predictions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Decameter storm radiation. II

The height, size, directivity, and lifetime of decametric storm sources are investigated. The height of the continuum sources is determined from the rotation rate, and the gradient of electron density for the regions of storm origin is computed by assuming that the radiation originates at the plasma frequency. The mean angular size of the sources is found to be quite large (increasing with decreasing frequency), the storm continuum is strongly directive toward the disk center, and east-west asymmetry is observed at decameter wavelengths. Two distinct classes of type III bursts are observed during storms: 'off-fringe' (displaced in position from the continuum source) and 'on-fringe' (coinciding in position with the continuum). A model of the storm region is proposed in which the 'on-fringe' bursts originate in regions of diverging field lines above closed magnetic loops and the 'off-fringe' bursts are excited by energetic electron streams having access to open field lines at the base of the loops.

Gergely, T. E.↗

Fabry-Perot-interferometer imaging system for thermospheric temperature and wind measurements

Doppler-broadened Fabry-Perot fringes of weak (less than 1-kR) auroral forbidden O I 5577- and 6300-A emissions have been detected in real time (1/60 sec) with the aid of a low-light level image-orthicon TV camera coupled to a two-stage image intensifier. The imaging scheme permits static-mode operation of a Fabry-Perot interferometer. For maximum use of all the information contained in every TV frame, each circular fringe may be sectioned into several annuli, and the corresponding annuli from all rings are summed to yield an intensity value. This procedure for deriving a fringe profile requires a video digitizer coupled to a digital processing system and should provide fast real-time (1/60 sec) measurements of E- and F-region temperatures and winds. With forbidden O I 5577-A intensity of 750 R, visually prominent TV images of the Fabry-Perot fringes were recorded in 0.5 sec, and the temperature of the emitting region was determined from two percent of the total information in the TV image.

Sivjee, G. G.↗

Measurements of displacement around holes in composite plates subjected to quasi-static compression

Attempts to develop a whole-field, high sensitivity optical technque for measurement of load induced changes of thickness of composite plates are described. Graphite-epoxy plates of quasi-isotropic layup were used as test specimens. Changes of thickness of three plates, each with a central hole of different size, were measured as a function of applied compressive loads. The first test specimen showed localized zones where no holographic fringes were present, surrounded by zones of low fringe contrast. This was thought to be a result of localized motion or creep. Subsequent tests with an increased time interval between specimen loading and holographic exposure demonstrated no localized zones of absent fringes. No plausible explanation for radical differences in the quality of fringe patterns was found, although the use of specimens having a high quality mirrorized surface provided superior change of thickness patterns. Recommendations for further investigations and changes in test procedure are presented.

Duke, J. C., Jr.↗

Automatic evaluation of interferograms

A system for the evaluation of interference patterns was developed. For digitizing and processing of the interferograms from classical and holographic interferometers a picture analysis system based upon a computer with a television digitizer was installed. Depending on the quality of the interferograms, four different picture enhancement operations may be used: Signal averaging; spatial smoothing, subtraction of the overlayed intensity function and the removal of distortion-patterns using a spatial filtering technique in the frequency spectrum of the interferograms. The extraction of fringe loci from the digitized interferograms is performed by a foating-threshold method. The fringes are numbered using a special scheme after the removal of any fringe disconnections which appeared if there was insufficient contrast in the holograms. The reconstruction of the object function from the fringe field uses least squares approximation with spline fit. Applications are given.

Becker, F.↗

Measurement of the configuration of a concave surface by the interference of reflected light

A method whereby a concave surface is irradiated with coherent light and the resulting interference fringes yield information on the concave surface is described. This method can be applied to a surface which satisfies the following conditions: (1) the concave face has a mirror surface; (2) the profile of the face is expressed by a mathematical function with a point of inflection. In this interferometry, multilight waves reflected from the concave surface interfere and make fringes wherever the reflected light propagates. Interference fringe orders. Photographs of the fringe patterns for a uniformly loaded thin silicon plate clamped at the edge are shown experimentally. The experimental and the theoretical values of the maximum optical path difference show good agreement. This simple method can be applied to obtain accurate information on concave surfaces.

Kumazawa, T.↗

Application of digital holographic interferometry to pressure measurements of symmetric, supercritical and circulation-control airfoils in transonic flow fields

Six airfoil interferograms were evaluated using a semiautomatic image-processor system which digitizes, segments, and extracts the fringe coordinates along a polygonal line. The resulting fringe order function was converted into density and pressure distributions and a comparison was made with pressure transducer data at the same wind tunnel test conditions. Three airfoil shapes were used in the evaluation to test the capabilities of the image processor with a variety of flows. Symmetric, supercritical, and circulation-control airfoil interferograms provided fringe patterns with shocks, separated flows, and high-pressure regions for evaluation. Regions along the polygon line with very clear fringe patterns yielded results within 1% of transducer measurements, while poorer quality regions, particularly near the leading and trailing edges, yielded results that were not as good.

Torres, Francisco J.↗

Information retrieval from holographic interferograms: Fundamentals and problems

Holographic interferograms can contain large amounts of information about flow and temperature fields. Their information content can be very high because they can be viewed from many different directions. This multidirectionality, and fringe localization add to the information contained in the fringe pattern if diffuse illumination is used. Additional information, and increased accuracy can be obtained through the use of dual reference wave holography to add reference fringes or to effect discrete phase shift or hetrodyne interferometry. Automated analysis of fringes is possible if interferograms are of simple structure and good quality. However, in practice a large number of practical problems can arise, so that a difficult image processing task results.

Vest, Charles M.↗

Application of digital interferogram evaluation techniques to the measurement of 3-D flow fields

A system for digitally evaluating interferograms, based on an image processing system connected to a host computer, was implemented. The system supports one- and two-dimensional interferogram evaluations. Interferograms are digitized, enhanced, and then segmented. The fringe coordinates are extracted, and the fringes are represented as polygonal data structures. Fringe numbering and fringe interpolation modules are implemented. The system supports editing and interactive features, as well as graphic visualization. An application of the system to the evaluation of double exposure interferograms from the transonic flow field around a helicopter blade and the reconstruction of the three dimensional flow field is given.

Becker, Friedhelm↗

Interferogram analysis using Fourier transform techniques

A method of interferogram analysis is described in which Fourier transform techniques are used to map the complex fringe visibility in several types of interferograms. Algorithms are developed for estimation of both the amplitude and the phase of the fringes (yielding the modulus and the phase of the holographically recorded object Fourier transform). The algorithms were applied to the reduction of interferometric seeing measurements (i.e., the estimation of the fringe amplitude only), and the reduction of interferometric tests (i.e., estimation of the fringe phase only). The method was used to analyze scatter-plate interferograms obtained at NOAO.

Roddier, Claude↗

Application of digital holographic interferometry to pressure measurements of symmetric, supercritical, and circulation control airfoils in transonic flow fields

Six airfoil interferograms were evaluated using a semiautomatic image-processor system which digitizes, segments, and extracts the fringe coordinates along a polygonal line. The resulting fringe order function was converted into density and pressure distributions and a comparison was made with pressure transducer data at the same wind tunnel test conditions. Three airfoil shapes were used in the evaluation to test the capabilities of the image processor with a variety of flows. Symmetric, supercritical, and circulation-control airfoil interferograms provided fringe patterns with shocks, separated flows, and high-pressure regions for evaluation. Regions along the polygon line with very clear fringe patterns yielded results within 1 percent of transducer measurements, while poorer quality regions, particularly near the leading and trailing edges, yielded results that were not as good.

Torres, Francisco J.↗

Holographic interferometry at the NASA-Ames Hypervelocity Free-Flight Aerodynamic Facility

A laser holographic interferometer has been designed and developed to improve flow visualization for models in free-flight at high velocities and low freestream static pressures. Of special interest is the flow structure due to high-temperature effects in the post-shock region of models traveling at hypervelocity. A dual-plate technique with a double-pass, Michelson-type configuration has been incorporated in an existing hypervelocity ballistic range. Holograms of 5-deg blunt conical models traveling at 5 km/sec in air at a freestream static pressure of 0.08 atm have been made. Finite- and infinite-fringe interferograms were reconstructed from the holograms and provided qualitative flowfield results. In addition, a digital scanning technique was also used to produce a 'synthetic' infinite-fringe interferogram from the analysis of an experimental finite-fringe interferogram. A 'synthetic' infinite-fringe interferogram shows detail in the wake region not found in the experimental interferograms.

Tam, Tim C.↗

Phase-Shifting Liquid Crystal Point-Diffraction Interferometry

Microgravity fluid physics experiments frequently measure concentration and temperature. Interferometers such as the Twyman Green illustrated have performed full-field measurement of these quantities. As with most such devices, this interferometer uses a reference path that is not common with the path through the test section. Recombination of the test and reference wavefronts produces interference fringes. Unfortunately, in order to obtain stable fringes, the alignment of both the test and reference paths must be maintained to within a fraction of the wavelength of the light being used for the measurement. Otherwise, the fringes will shift and may disappear. Because these interferometers are extremely sensitive to bumping, jarring and transmitted vibration, they are typically mounted on optical isolation tables. Schlieren deflectometers or the more recent Shack-Hartmann wavefront sensors also measure concentration and temperature in laboratory fluid flows. Ray optics describe the operation of both devices. In a schlieren system, an expanded, collimated beam passes through a test section where refractive index gradients deflect rays. A lens focuses the beam to a filter placed in the rear focal plane of the decollimating lens. In a quantitative color schlieren system, gradients in the index of refraction appear as colors in the field of view due to the action of the color filter. Since sensitivity is a function of the focal length of the decollimating lens, these systems are rather long and filter fabrication and calibration is rather difficult. A Shack-Hartmann wavefront sensor is an array of small lenslets. Typical diameters are on the order of a few hundred microns. Since these lenslets divide the test section into resolution elements, the spatial resolution can be no smaller than an individual lenslet. Such a device was recently used to perform high-speed tomography of heated air exiting a 1.27 cm diameter nozzle. While these wavefront sensors are very compact, the limited spatial resolution and the methods required for data reduction suggest that a more useful instrument needs to be developed. The category of interferometers known as common path interferometers can eliminate much of the vibration sensitivity associated with traditional interferometry as described above. In these devices, division of the amplitude of the wavefront following the test section produces the reference beam. Examples of these instruments include shearing and point diffraction interferometers. In the latter case, shown schematically, a lens focuses light passing through the test section onto a small diffracting object. Such objects are typically either a circle of material on a high quality glass plate or a small sphere in a glass cell. The size of the focused spot is several times larger than the object so that the light not intercepted by the diffracting object forms the test beam while the diffracted light generates a spherical reference beam. While this configuration is mechanically stable, phase shifting one beam with respect to the other is difficult due to the common path. Phase shifting enables extremely accurate measurements of the phase of the interferogram using only gray scale intensity measurements and is the de facto standard of industry. Mercer and Creath 2 demonstrated phase shifting in a point diffraction interferometer using a spherical spacer in a liquid crystal cell as the diffracting object. By changing the voltage across the cell, they were able to shift the phase of the undiffracted beam relative to the reference beam generated by diffraction from the sphere. While they applied this technology to fluid measurements, the device shifted phase so slowly that it was not useful for studying transient phenomena. We have identified several technical problems that precluded operation of the device at video frame rates and intend to solve them to produce a phase-shifting liquid crystal point-diffraction interferometer operating at video frame rates. The first task is to produce high contrast fringes. Since the diffracted beam is much weaker than the transmitted beam, interferograms have poor contrast unless a dye is added to the liquid crystal to reduce the intensity of the undiffracted light. Dyes previously used were not rigorously characterized and suffered from hysteresis in both the initial alignment state of the device and the electro-optic switching characteristics. Hence, our initial effort will identify and characterize dyes that do not suffer from these difficulties and are readily soluble in the liquid crystal host. Since the ultimate goal of this research is to produce interferometers capable of phase shifting at video frame rates, we will quantify the difference in switching times between ferroelectric and nematic liquid crystals. While we have more experience with nematic crystals, they typically switch more slowly than ferroelectric cells. As part of that effort, we will investigate the difference in the modulation of the interferograms as a function of the type of liquid crystal in the cell. Because the temporal switching response of a liquid crystal cell is directly related its thickness, we intend to explore techniques required to produce cells that are as thin as possible. However, the cells must still produce a total phase shift of two pi radians.

Griffin, DeVon W.↗

Time-Average Measurement of Velocity, Density, Temperature, and Turbulence Using Molecular Rayleigh Scattering

Measurement of time-averaged velocity, density, temperature, and turbulence in gas flows using a nonintrusive, point-wise measurement technique based on molecular Rayleigh scattering is discussed. Subsonic and supersonic flows in a 25.4-mm diameter free jet facility were studied. The developed instrumentation utilizes a Fabry-Perot interferometer to spectrally resolve molecularly scattered light from a laser beam passed through a gas flow. The spectrum of the scattered light contains information about velocity, density, and temperature of the gas. The technique uses a slow scan, low noise 16-bit depth CCD camera to record images of the fringes formed by Rayleigh scattered light passing through the interferometer. A kinetic theory model of the Rayleigh scattered light is used in a nonlinear least squares fitting routine to estimate the unknown parameters from the fringe images. The ability to extract turbulence information from the fringe image data proved to be a challenge since the fringe is broadened by not only turbulence, but also thermal fluctuations and aperture effects from collecting light over a range of scattering angles. Figure 1 illustrates broadening of a Rayleigh spectrum typical of flow conditions observed in this work due to aperture effects and turbulence for a scattering angle, chi(sub s), of 90 degrees, f/3.67 collection optics, mean flow velocity, u(sub k), of 300 m/s, and turbulent velocity fluctuations, sigma (sub uk), of 55 m/s. The greatest difficulty in processing the image data was decoupling the thermal and turbulence broadening in the spectrum. To aid in this endeavor, it was necessary to seed the ambient air with smoke and dust particulates; taking advantage of the turbulence broadening in the Mie scattering component of the spectrum of the collected light (not shown in the figure). The primary jet flow was not seeded due to the difficulty of the task. For measurement points lacking particles, velocity, density, and temperature information could reliably be recovered, however the turbulence estimates contained significant uncertainty. Resulting flow parameter estimates are presented for surveys of Mach 0.6, 0.95, and 1.4 jet flows. Velocity, density, and temperature were determined with accuracies of 5 m/s, 1.5%, and 1%, respectively, in flows with no particles present, and with accuracies of 5 m/s, 1-4%, and 2% in flows with particles. Comparison with hotwire data for the Mach 0.6 condition demonstrated turbulence estimates with accuracies of about 5 m/s outside the jet core where Mie scattering from dust/smoke particulates aided in the estimation of turbulence. Turbulence estimates could not be recovered with any significant accuracy for measurement points where no particles were present.

Mielke, Amy F.↗

The StarLight Space Interferometer: Optical design and performance modeling

The StarLight mission aimed to place the first formation flying optical interferometer into space in year 2006. Utilizing two spacecraft to form a long baseline Michelson interferometer, it would measure white light fringes on a number of partially resolved stars of magnitudes >5 in the wavelength range 600 to 1000nm. The interferometer baseline is variable between 30 and 125 m, and also has a fixed 1 m mode. The spacecraft are flown in a parabolic geometry which requires an optical delay line to build up more than 14m of delay on one arm of the interferometer. To obtain high fringe visibility, starlight wavefront, pointing and intensity must be preserved through 22 reflections from mirrors and beamsplitters. The alignment of a total of 27 optics is maintained through careful thermal design and the use of two actuated mirrors on each arm. This paper describes the optical layout in depth, including the beam combiner design which allows star tracking, optical system alignment and fringe formation on a single CCD. The effects of diffraction of the starlight transferred from a distant spacecraft and from optical surface imperfections are modeled. Other contributors to the visibility budget and the resulting variation of fringe visibility across the focal plane are discussed .

StarLight↗

Tunable diode laser absorption spectroscopy with corrected laser ramping nonlinearities

A tunable diode laser absorption spectroscopy device includes a tunable diode laser. A laser driver is configured to drive the diode laser and ramp it within a particular frequency range. An analyte gas container, a reference gas container, and a fringe generating device are configured to receive the laser therethrough. An optical detector is configured to detect the laser after it has passed through the analyte gas container and/or the reference gas container, and the in-line fringe generating device. An acquisition card is configured to sample an output of the optical detector. A spectral analyzer is configured to receive output data from the acquisition card, determine a spectrum of the output data, decouple the fringe spectrum from the measured spectrum, calibrate the spectrum based on an expected ideal spectrum of both the fringe and reference gas, and determine a composition of the analyte based on the calibrated spectrum.

42 ENGINEERING↗