Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fourier transforms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Application of the one-dimensional Fourier transform for tracking moving objects in noisy environments

In Riddle and Rajala (1981), an algorithm was presented which operates on an image sequence to identify all sets of pixels having the same velocity. The algorithm operates by performing a transformation in which all pixels with the same two-dimensional velocity map to a peak in a transform space. The transform can be decomposed into applications of the one-dimensional Fourier transform and therefore can gain from the computational advantages of the FFT. The aim of this paper is the concern with the fundamental limitations of that algorithm, particularly as relates to its sensitivity to image-disturbing parameters as noise, jitter, and clutter. A modification to the algorithm is then proposed which increases its robustness in the presence of these disturbances.

Rajala, S. A.↗

Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at the Cyclotron Frequency

The phenomenon of ion cyclotron resonance allows for determining mass-to-charge ratio, m/z, of an ensemble of ions by means of measurements of their cyclotron frequency, ω{sub c}. In Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), the ω{sub c} quantity is usually unavailable for direct measurements: the resonant state is located close to the reduced cyclotron frequency (ω{sub +}), whereas the ω{sub c} and the corresponding m/z values may be calculated via theoretical derivation from an experimental estimate of the ω{sub +} quantity. Here, we describe an experimental observation of a new resonant state, which is located close to the ω{sub c} frequency and is established because of azimuthally-dependent trapping electric fields of the recently developed ICR cells with narrow aperture detection electrodes. We show that in mass spectra, peaks close to ω{sub +} frequencies can be reduced to negligible levels relative to peaks close to ω{sub c} frequencies. Due to reduced errors with which the ω{sub c} quantity is obtained, the new resonance provides a means of cyclotron frequency measurements with precision greater than that achieved when ω{sub +} frequency peaks are employed. The described phenomenon may be considered for a development into an FT-ICR MS technology with increased mass accuracy for applications in basic research, life, and environmental sciences. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of grain-size distribution function using two-dimensional Fourier transforms of tone-pulse-encoded images

Microstructural images may be tone pulse encoded and subsequently Fourier transformed to determine the two-dimensional density of frequency components. A theory is developed relating the density of frequency components to the density of length components. The density of length components corresponds directly to the actual grain-size distribution function from which the mean grain shape, size, and orientation can be obtained.

Generazio, E. R.↗

Continued Development of a Planetary Imaging Fourier Transform Spectrometer (PIFTS)

This report describes continued efforts to evaluate a breadboard of a Planetary Imaging Fourier Transform Spectrometer (PIFTS). The PIFTS breadboard was developed under prior PIDDP funding. That effort is described in the final report for NASA Grant NAG5-6248 and in two conference papers (Sromovsky et al. 2000; Revercomb et al. 2000). The PIFTS breadboard was designed for near-IR (1-5.2 micrometer imaging of planetary targets with spectral resolving powers of several hundred to several thousand, using an InSb detector array providing at least 64x64 pixels imaging detail. The major focus of the development effort was to combine existing technologies to produce a small and low power design compatible with a very low mass flyable instrument. The objective of this grant (NAG5-10729) was further characterization of the breadboard performance, including intercomparisons with the highly accurate non-imaging Advanced Emitted Radiance Interferometer (AERI) (Revercomb et al. 1994; Best et al. 1997).

Sromovsky, L. A.↗

Reference Ultraviolet Wavelengths of Cr III Measured by Fourier Transform Spectrometry

We report Cr III ultraviolet (UV) transition wavelengths measured using a high-resolution Fourier transform spectrometer (FTS), for the first time, available for use as wavelength standards. The doubly ionized iron group element spectra dominate the observed opacity of hot B stars in the UV, and improved, accurate, wavelengths are required for the analysis of astronomical spectra. The spectrum was excited using a chromium-neon Penning discharge lamp and measured with the Imperial College vacuum ultraviolet FTS. 140 classified 3d(exp 3)4s- 3d(exp 3)4p Cr III transition lines, in the spectral range 38,000 to 49,000 cm(exp -1) (2632 to 2041 A), the strongest having wavelength uncertainties less than one part in 10(exp 7), are presented.

Smillie, D.G.↗

Two-dimensional fourier transform spectrometer

The present invention relates to a system and methods for acquiring two-dimensional Fourier transform (2D FT) spectra. Overlap of a collinear pulse pair and probe induce a molecular response which is collected by spectral dispersion of the signal modulated probe beam. Simultaneous collection of the molecular response, pulse timing and characteristics permit real time phasing and rapid acquisition of spectra. Full spectra are acquired as a function of pulse pair timings and numerically transformed to achieve the full frequency-frequency spectrum. This method demonstrates the ability to acquire information on molecular dynamics, couplings and structure in a simple apparatus. Multi-dimensional methods can be used for diagnostic and analytical measurements in the biological, biomedical, and chemical fields.

47 OTHER INSTRUMENTATION↗

Two-dimensional fourier transform spectrometer

The present invention relates to a system and methods for acquiring two-dimensional Fourier transform (2D FT) spectra. Overlap of a collinear pulse pair and probe induce a molecular response which is collected by spectral dispersion of the signal modulated probe beam. Simultaneous collection of the molecular response, pulse timing and characteristics permit real time phasing and rapid acquisition of spectra. Full spectra are acquired as a function of pulse pair timings and numerically transformed to achieve the full frequency-frequency spectrum. This method demonstrates the ability to acquire information on molecular dynamics, couplings and structure in a simple apparatus. Multi-dimensional methods can be used for diagnostic and analytical measurements in the biological, biomedical, and chemical fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exploring Biosignatures Associated with Thenardite by Geomatrix-Assisted Laser Desorption/Ionization Fourier Transform Mass Spectrometry (GALDI-FTMS)

Geomatrix-assisted laser desorption/ionization (GALDI) in conjunction with a Fourier transform mass spectrometer (FTMS) has been employed to determine how well bio/organic molecules associated with the mineral thenardite (Na2SO4) can be detected. GALDI is based on the ability of the mineral host to assist desorption and ionization of bio/organic molecules without additional sample preparation. When glycine was mixed with thenardite, glycine was deprotonated to produce C2H4NO2 at m/z 74.025. The combination of stearic acid with thenardite produced a complex cluster ion at m/z 390.258 in the negative mode, which was assigned a composition of C18H39O7Na . A natural sample of thenardite from Searles Lake in California also produced a peak at m/z 390.260. The bio/organic signatures in both the laboratory-based and natural samples were heterogeneously dispersed as revealed by chemical imaging. The detection limits for the stearic acid and thenardite combination was estimated to be 3 parts per trillion or ~7 zeptomoles per laser spot. Attempts to improve the signal-to-noise ratio by co-adding FTMS data predetermined to contain the biosignatures of interest revealed problems due to a lack of phase coherence between data sets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adding diffuse reflectance infrared Fourier transform spectroscopy capability to extended x-ray-absorption fine structure in a new cell to study solid catalysts in combination with a modulation approach

We describe a novel cell used to combine in situ transmission X-ray absorption spectroscopy (XAS) with diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) in a single experiment. The novelty of the cell design compared to current examples is that both radiations are passed through an X-ray and IR transparent window in direct contact with the sample. This innovative geometry also offers a wide surface for IR collection. In order to avoid interference from the crystalline IR transparent materials (e.g., CaF{sub 2}, MgF{sub 2}, diamond) a 500 μm carbon filled hole is laser drilled in the center of a CaF{sub 2} window. The cell is designed to represent a plug flow reactor, has reduced dead volume in order to allow for fast exchange of gases and is therefore suitable for experiments under fast transients, e.g., according to the concentration modulation approach. High quality time-resolved XAS and DRIFTS data of a 2 wt.% Pt/Al{sub 2}O{sub 3} catalyst are obtained in concentration modulation experiments where CO (or H{sub 2}) pulses are alternated to O{sub 2} pulses at 150 °C. We show that additional information can be obtained on the Pt redox dynamic under working conditions thanks to the improved sensitivity given by the modulation approach followed by Phase Sensitive Detection (PSD) analysis. It is anticipated that the design of the novel cell is likely suitable for a number of other in situ spectroscopic and diffraction methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanistic aspects of plasma-enhanced catalytic methane decomposition by time-resolved operando diffuse reflectance infrared Fourier transform spectroscopy

To study mechanistic aspects of plasma-enhanced catalysis, methane is decomposed by a supported Ni catalyst assisted by an Ar/O 2 atmospheric pressure plasma jet (APPJ). Here, the time-resolved surface response of the Ni catalyst is investigated by operando diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) using various experimental settings. Catalyst temperatures of room temperature (RT) and 500 °C and nozzle-catalyst surface distances of 3, 5 and 8 mm were examined, and the amount of O 2 of the Ar/O 2 gas mixture flowing through the APPJ was either 0 or 0.5%. A synergistic effect of surface bonded C-O was observed during the exposure of the Ni catalyst to the APPJ for low oxygen operating conditions (pure Ar jet). Surface bonded C-O formed only when there was plasma present and the C-O signal was enhanced for higher catalyst temperature. When the supported Ni catalyst was subjected to the plasma-generated particle fluxes using highly oxidizing conditions, the presence of surface bonded C-O was suppressed. The plasma-catalytic CO and CO 2 production in the gas phase measured downstream mirrored the surface behavior of C-O bonds when the plasma source operating condition was changed from a low oxygen portion to a high oxygen portion at high catalyst temperature (500 °C). CH n (n =1, 2, ) species on the catalyst surface were also studied by DRIFTS, and CHn destruction was found to correlate with C-O formation. In particular, the time-resolved CH n response showed a possible conversion process of CH n to C-O when the Ni catalyst was exposed to the plasma source. This finding may indicate a plasma-mediated regeneration of the catalyst by plasma-catalyst surface interactions.

42 ENGINEERING↗

MEASUREMENT OF GALACTIC LOGARITHMIC SPIRAL ARM PITCH ANGLE USING TWO-DIMENSIONAL FAST FOURIER TRANSFORM DECOMPOSITION

A logarithmic spiral is a prominent feature appearing in a majority of observed galaxies. This feature has long been associated with the traditional Hubble classification scheme, but historical quotes of pitch angle of spiral galaxies have been almost exclusively qualitative. We have developed a methodology, utilizing two-dimensional fast Fourier transformations of images of spiral galaxies, in order to isolate and measure the pitch angles of their spiral arms. Our technique provides a quantitative way to measure this morphological feature. This will allow comparison of spiral galaxy pitch angle to other galactic parameters and test spiral arm genesis theories. In this work, we detail our image processing and analysis of spiral galaxy images and discuss the robustness of our analysis techniques.

79 ASTRONOMY AND ASTROPHYSICS↗

Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) peak intensity normalization for complex mixture analyses

Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) is a preferred technique for analyzing complex organic mixtures. Currently, there is no consensus normalization approach, nor an objective method for selecting one, for quantitative analyses of FT-ICR-MS data. We investigate a method to evaluate and score the amount of bias various normalization approaches introduce into the data. We evaluate the ability of the Statistical Procedure for the Analysis of Normalization Strategies (SPANS) to guide selection of appropriate normalization approaches for two different FT-ICR-MS datasets. Further, we test the robustness of SPANS results to changes in SPANS parameter values and assess the impact of using various normalization approaches on downstream statistical analyses. The normalization approach identified by SPANS differed for the two datasets. Normalization methods impacted the statistical significance of peaks differently, underscoring the importance of carefully evaluating potential methods. More consistent SPANS scores resulted when at least 120 significant peaks are used, where larger sets of peaks were obtained by increasing the p-value threshold. Interestingly, we show that Total Sum Scaling and highest peak normalization, used in previous studies, underperformed relative to SPANS-recommended normalization approaches. While there is no single, best normalization method for all datasets, SPANS provides a mechanism to identify an appropriate normalization method for analyzing FT-ICR-MS data quantitatively. As a result, the number of peaks used in the background distributions of SPANS contributes more significantly to the reproducibility of results than the p-value thresholds used to obtain those peaks.

47 OTHER INSTRUMENTATION↗

Feasibility study, software design, layout and simulation of a two-dimensional fast Fourier transform machine for use in optical array interferometry

The NASA-Cornell Univ.-Worcester Polytechnic Institute Fast Fourier Transform (FFT) chip based on the architecture of the systolic FFT computation as presented by Boriakoff is implemented into an operating device design. The kernel of the system, a systolic inner product floating point processor, was designed to be assembled into a systolic network that would take incoming data streams in pipeline fashion and provide an FFT output at the same rate, word by word. It was thoroughly simulated for proper operation, and it has passed a comprehensive set of tests showing no operational errors. The black box specifications of the chip, which conform to the initial requirements of the design as specified by NASA, are given. The five subcells are described and their high level function description, logic diagrams, and simulation results are presented. Some modification of the Read Only Memory (ROM) design were made, since some errors were found in it. Because a four stage pipeline structure was used, simulating such a structure is more difficult than an ordinary structure. Simulation methods are discussed. Chip signal protocols and chip pinout are explained.

Boriakoff, Valentin↗

FOURIER TRANSFORM EMISSION SPECTROSCOPY OF THE B {sup 2}{Sigma}{sup +}-X {sup 2}{Sigma}{sup +} (VIOLET) SYSTEM OF {sup 13}C{sup 14}N

Emission spectra of the B {sup 2}{Sigma}{sup +}-X {sup 2}{Sigma}{sup +} transition of {sup 13}C{sup 14}N have been observed at high resolution using the Fourier transform spectrometer associated with the McMath-Pierce Solar Telescope of the National Solar Observatory. The spectra have been measured in the 21000-30000 cm{sup -1} region and a total of 52 vibrational bands involving vibrational levels up to v = 15 of the ground and excited states have been rotationally analyzed to provide a much improved set of spectroscopic constants. An experimental line list and calculated term values are provided. The results of the present analysis should prove useful in the identification of additional {sup 13}C{sup 14}N lines in comets and cool stars, and will help in the determination of the {sup 12}C/{sup 13}C abundance ratio.

79 ASTRONOMY AND ASTROPHYSICS↗

Singlet and triplet potentials of the ground-state atom pair Rb + Cs studied by Fourier-transform spectroscopy

A comprehensive study of the X {sup 1}{Sigma}{sup +} and a {sup 3}{Sigma}{sup +} electronic states of the Rb and Cs atom pair in RbCs is presented. Abundant spectroscopic data for the {sup 85}Rb{sup 133}Cs and {sup 87}Rb{sup 133}Cs isotopologues were obtained from Fourier-transform spectra of laser-induced fluorescence (LIF) from the B {sup 1}{Pi} and (4){sup 1}{Sigma}{sup +} states to the a {sup 3}{Sigma}{sup +} (4549 transitions) and X {sup 1}{Sigma}{sup +} (15 709 transitions) states. The X {sup 1}{Sigma}{sup +} state data were complemented by about 15 500 transitions obtained by Fellows et al.[J. Mol. Spectrosc. 197, 19 (1999)]. LIF progressions to the a {sup 3}{Sigma}{sup +} state range from v{sub a}=0 to 37, reaching an outer turning point at 15.97 A. For the X {sup 1}{Sigma}{sup +} state, by analyzing LIF from the shelflike (4){sup 1}{Sigma}{sup +}, the data are extended from v{sub x}=119 as observed in the above-cited paper to v{sub x}=129, extending the outer turning point from 10.7 to 17.55 A. From these data, potential energy curves were constructed simultaneously for both hyperfine coupled states X {sup 1}{Sigma}{sup +} and a {sup 3}{Sigma}{sup +} in a coupled-channels fitting routine. This allowed us to accurately model the potential close to the Rb(5s) + Cs(6s) atom-pair asymptote, which is required to simulate cold collision processes and to analyze the Feshbach resonances observed for {sup 87}Rb{sup 133}Cs by Pilch et al.[Phys. Rev. A 79, 042718 (2009)]. Dissociation energies were determined for the X {sup 1}{Sigma}{sup +} state as D{sub e}=3836.373(40) cm{sup -1} and for the a {sup 3}{Sigma}{sup +} state as D{sub e}=259.341(30) cm{sup -1}.

74 ATOMIC AND MOLECULAR PHYSICS↗

Determining Energies and Cross Sections of Individual Ions Using Higher-Order Harmonics in Fourier Transform Charge Detection Mass Spectrometry (FT-CDMS)

A general method for in situ measurements of the energy of individual ions trapped and weighed using charge detection mass spectrometry (CDMS) is described. Highly charged (> 300 e), individual polyethylene glycol (PEG) ions are trapped and oscillate within an electrostatic trap, producing a time domain signal. A segmented Fourier transform (FT) of this signal yields the temporal evolution of the fundamental and harmonic frequencies of ion motion throughout the 500-ms trap time. The ratio of the fundamental frequency and second harmonic (HAR) depends on the ion energy, which is an essential parameter for measuring ion mass in CDMS. This relationship is calibrated using simulated ion signals, and the calibration is compared to the HAR values measured for PEG ion signals where the ion energy was also determined using an independent method that requires that the ions be highly charged (> 300 e). The mean error of 0.6% between the two measurements indicates that the HAR method is an accurate means of ion energy determination that does not depend on ion size or charge. The HAR is determined dynamically over the entire trapping period, making it possible to observe the change in ion energy that takes place as solvent evaporates from the ion and collisions with background gas occur. This method makes it possible to measure mass changes, either from solvent evaporation or from molecular fragmentation (MS{sup n}), as well as the cross sections of ions measured using CDMS. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fourier Transform IR Spectroscopic Study of Nano-ZrO{sub 2} + Nano-SiO{sub 2} + Nano-H{sub 2}O Systems Upon the Action of Gamma Radiation

The radiation decomposition of water in a nano-ZrO{sub 2} + nano-SiO{sub 2} + H{sub 2}O system at 300 K by the action of gamma radiation has been studied by Fourier transform IR spectroscopy. Water adsorption in the zirconium and silicon nanooxides is attributed to molecular and dissociative mechanisms. Active intermediates in this radiation-induced heterogeneous decomposition of water were detected including zirconium and silicon hydrides and hydroxyl groups. Variation in the ratio of ZrO{sub 2} and SiO{sub 2} nanopowders was shown to lead to change in their radiation catalytic activity compared to initial ZrO{sub 2}.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Attosecond nonlinear Fourier transformation spectroscopy of CO{sub 2} in extreme ultraviolet wavelength region

The interferometric autocorrelation functions of attosecond pulse trains in the time domain were measured by detecting CO{sub 2}{sup 2+} as well as the atomic and molecular fragment ions generated via two-photon absorption of intense vacuum ultraviolet-extreme ultraviolet light by CO{sub 2}. It was demonstrated that the Fourier transformation of the interferometric autocorrelation functions of the respective fragment ions appearing in a time-of-flight mass spectrum exhibit spectroscopic information in the frequency domain corresponding to the two-photon photofragment excitation spectra of CO{sub 2} and the double ionization excitation spectrum to form CO{sub 2}{sup 2+}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗