Oil and gas flow through fractures and along interfaces in well cement

A number of wells at the Strategic Petroleum Reserve (SPR) have shown sustained, positive pressure (referred to as sustained casing pressure or SCP) in the cemented annulus behind the production casing. To better understand how SCP may develop for SPR conditions, we conducted gas and oil flow tests on cement specimens with flaws including cement fractures and discrete interfaces along a cement-steel contact. Many specimens were tested initially with gas, followed by oil, and finally with gas again to identify how the fluid type may affect the flow through flaws in the well cement. Nitrogen was used as the gas, and silicone oil with properties similar to typical crude oil was used in most tests. One set of measurements were made with crude oil. Composite steel-cement specimen with corroded steel were also tested. For both gas and oil tests, the measured flow test data were used to interpret permeability and, assuming the cubic law for flow between parallel plates, the corresponding hydraulic aperture of the flaw. The hydraulic apertures for the flawed specimens ranged from about 20 to >100 μm, which corresponds to permeabilities of about 10 -14 to 10 -12 m 2 , respectively; these hydraulic apertures are consistent with the range of values interpreted from field measurements on leaky wells. Observed differences between the flow of gas and oil were attributed to a number of factors, including non-linear flow of gas, possible blocking of flow paths by solids within the crude oil, two-phase gas and oil flow and the presence of residual oil in the cement flaw. Furthermore, we determined that corroded steel itself is permeable. Using input values consistent with the gas and oil flow measurements, we conducted one-dimensional simulations of gas and oil flow through cemented annulus systems to investigate the role of flaw size and fluid type on the expected response (i.e., pressure build-up) in the annular cement.

02 PETROLEUM↗

Probabilistic and Other Neural Nets in Multi-Hole Probe Calibration and Flow Angularity Pattern Recognition

The use of probabilistic (PNN) and multilayer feed forward (MLFNN) neural networks are investigated for calibration of multi-hole pressure probes and the prediction of associated flow angularity patterns in test flow fields. Both types of networks are studied in detail for their calibration and prediction characteristics. The current formalism can be applied to any multi-hole probe, however the test results for the most commonly used five-hole Cone and Prism probe types alone are reported in this article.

Baskaran, Subbiah↗

Hydraulic Response to Thermal Stimulation Efforts at Raft River Based on Stepped Rate Injection Testing

The injection well stimulation project at the Raft River geothermal field tests the effect of long-term cold water injection and high pressure injection on well injectivity, improvements to which could reduce operating costs. The primary data for analysis and interpretation of the injection test are step-rate flow tests run before each new phase of the injection. These tests were analyzed using a combination of standard pump-test analytical solution methods and methods developed expressly for the observed conditions. The stepped rate injection tests, combined with long-term flow and pressure response data suggest that the well is located within a fractured formation of low transmissivity but high storativity. These calculated parameters appeared to increase with pressure during the first injection test and the higher values were reproduced during the second stepped rate test. Calculated transmissivity and storativity are on the order of 4E-5 m cm 2 and 1E-4 m Pa -1 , respectively. The apparent pressure dependence of fitted hydraulic parameters may reflect near-well fracture compliance that increased the effective radius of the wellbore during the first test. While the type curve fit analysis also suggests that the reservoir behaves as a uniformly fractured reservoir with a radial flow regime, the hydraulic parameters indicate that condition may exist only a very limited distance (<10 m) from the well. Longer-term pressure response suggests that flow in the system effectively reaches steady state in a period of less than a day, which may reflect pressure stabilization resulting from pressure-dependent permeability or a region of much higher permeability located with a few meters of the well. The transmissivity estimates obtained from this analysis, converted to approximate fracture density and aperture, provide useful constraints on the distance to which the thermal front may migrate from the well during the cold water injection phase of the stimulation project. We estimate that the cooling front will migrate less than a tenth of a kilometer over an approximately one-year injection period. Here, the effects of that cooling, however, may be substantial, because increases in permeability have maximum effect nearest the well.

cold water injection↗

EGS Collab Earth Modeling: Integrated 3D Model of the Testbed

The EGS Collab project is conducting a series of stimulation and interwell flow tests in an intermediate scale (~10-20 m) testbed located on the 4850 level in the Sanford Underground Research Facility (SURF) in Lead, South Dakota. The testbed consists of eight ~200 ft (~60 m) HQ-diameter (9.6 cm) boreholes that are drilled into the Poorman Formation from the western rib of the West Access Drift. Of the eight boreholes, one borehole is used as an injection/stimulation well, another sub-parallel borehole located about 10 m away from the injection well is used as a production well, and rest of the other boreholes are used as monitoring wells. For 3D visualization of the testbed as well as to provide spatially accurate and consistent parameter data for geomechanical and geophysical process modeling tasks, we are using Leapfrog Software (Seequent Limited). For analysis of fractures and creation of conditioned stochastic discrete fracture network (CS-DFN) model of the testbed, we are using FracMan (Golder Associates Inc.). As of mid-May 2019, the EGS Collab Leapfrog database contains the general layout of the drifts/shafts at the 4850 and 4100 levels; generalized geologic framework model of a domain that spans both the 4850 and 4100 levels; the CS-DFN of the testbed; and layouts of the EGS Collab testbed boreholes, kISMET testbed boreholes, and other existing boreholes at the 4850 level. This information has been obtained from the SURF Vulcan database, detailed laser scan and point surveys of borehole collar locations, directional surveys of borehole trajectories, and mapping of features in the drifts, boreholes, and cores. Similarly, other types of data that have been incorporated into the Leapfrog database include static features of the testbed such as natural discontinuities (e.g., fractures, weeps), location of monitoring instruments, and stimulation notches. Baseline geophysical characterization results (e.g., seismic, ERT, temperature, etc.) are also imported into the Leapfrog database. The location and size of packers, various point-source signals detected during stimulation and flow tests (e.g., temperature anomalies, micro-earthquake events, etc.) are also compiled in the database. All feature locations are reported using the local Homestake Mine coordinate system. In this paper, we present some of the geostructural characteristics as well as the status of the testbed as represented by Leapfrog/FracMan database/visualizations.

15 GEOTHERMAL ENERGY↗

Flow properties in expansion tube with helium, argon, air, and CO2

Test flow velocities from 5 to 7 km/sec were generated in a 6-in. expansion tube using helium, argon, air, and CO2 test gases. Pitot pressure profiles across the flow at the test section are presented for the four test gases, and measured flow quantities are compared to computer predicted values. Comparison of predicted and measured flow quantities suggests the expansion to be near thermochemical equilibrium for all test gases and implies the existence of a totally reflected shock at the secondary diaphragm. Argon, air, and CO2 flows were observed to attenuate while traversing the acceleration section, whereas no attenuation was observed for helium.

Miller, C. G.↗

Copper-doped silica materials silanized with bis-(triethoxy silyl propyl)-tetra sulfide for mercury vapor capture

The use of Cu-S sites for Hg capture from the gas phase has been successfully applied to a silica-based platform using an S4 organic polysulfane and copper sulfate. The maximum fixed-bed equilibrium capacity achieved using these materials was 19 789 {mu}g Hg.g{sup -1} sorbent for a material with 2.5 wt % Cu and 6 wt % S. An optimal S level was determined to be around 3 wt % because enhancement of capacity was only 18% when increasing from this 3 to 6 wt %. The rate of adsorption in pure beds ranged from 0.6 to 1.6 {mu}g Hg.min{sup -1} depending on the inlet concentration. Differences in breakthrough times suggest that material deposition is not uniform. When compared to two other platforms, commercially available Darco HG-LH and previously tested Fe-Cu-S4 nanoaggregates, the Si-1 material performed the best in fixed-bed testing. During entrained-flow testing, a steady-state Hg removal of 82% was achieved using Si-1 at injection rates of both 6 x 10{sup -5} and 1.2 x 10{sup -4} g.L{sup -1}.h{sup -1}. The lack of increase in Hg removal when the injection rate is doubled suggests that pore accessibility is the rate-controlling step during dynamic Hg capture. A calculation of the approximate pore usage based on injection testing helped confirm this observation. During injection testing, the performance of Si-1 was only diminished 10% when exposed to 20 ppm SO{sub 3}. This is an encouraging result for flue-gas applications where SO{sub 3} levels range from 1 to 40 ppm. Testing demonstrated that Si-1 is stable when exposed to leaching conditions after concrete blending and cement impregnation. This is an important aspect to consider for injection because the sale of fly ash for concrete is a key cost-recovery tool for power plants. 27 refs., 8 figs., 5 tabs.

01 COAL, LIGNITE, AND PEAT↗

Isospin distillation with radial flow: A test of the nuclear symmetry energy

We discuss mechanisms related to isospin transport in central collisions between neutron-rich systems at Fermi energies to gain information on the nuclear symmetry energy at and below saturation. A fully consistent study of the isospin distillation and expansion dynamics in two-component systems is presented in the framework of a stochastic transport theory. We analyze correlations between fragment observables, focusing on the study of the fragment asymmetry N/Z as a function of their kinetic energy. We find that the relation between these observables allows us to better characterize the fragmentation path and to access new information on the low-density behavior of the symmetry energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Flow Sensor Test Article (F-STAr) - Status Report for FY2021

This report will review updates on the status of F-STAr. First, the report will describe a general overview of the test article and how each component interacts. Then, each main component will be discussed in a deep dive section which will review the design and other relevant details. F-STAr components which are discussed in more detail include the 120 GPM-pump, the support structure and test sections, 5 kW-heater, the 2 kW-cooler and cooling system, and the submersible flowmeter. Finally, this report will conclude with a brief recap and a bulleted outline of the path moving forward.

42 ENGINEERING↗

Experimental study of flow distribution with circumferential manifolds

Water flow test results on fluid flow distribution and pressure loss in curved manifolds with tangential or radial entry are reported. Manifolds were studied both as inlet and outlet manifolds. Manifolds can be used for boilers and/or heat exchangers for advanced space electric power plants.

Dittrich, R. T.↗

Development of the technology for the fabrication of reliable laminar from control panels

Materials were assessed and fabrication techniques were developed for use in the manufacture of wing surface materials compatible with the application of both aluminum alloys and nonmetallic composites. The concepts investigated included perforations and slots in the metallic test panels and microporosity and perforations in the composite test panels. Perforations were produced in the metallic test panels by the electron beam process and slots were developed by controlled gaps between the metal sheets. Microporosity was produced in the composite test panels by the resin bleed process, and perforations were produced by the fugitive fiber technique. Each of these concepts was fabricated into test panels, and air flow tests were conducted on the panels.

Meade, L. E.↗

The NASA Lewis Research Center Internal Fluid Mechanics Facility

An experimental facility specifically designed to investigate internal fluid duct flows is described. It is built in a modular fashion so that a variety of internal flow test hardware can be installed in the facility with minimal facility reconfiguration. The facility and test hardware interfaces are discussed along with design constraints of future test hardware. The plenum flow conditioning approach is also detailed. Available instrumentation and data acquisition capabilities are discussed. The incoming flow quality was documented over the current facility operating range. The incoming flow produces well behaved turbulent boundary layers with a uniform core. For the calibration duct used, the boundary layers approached 10 percent of the duct radius. Freestream turbulence levels at the various operating conditions varied from 0.64 to 0.69 percent of the average freestream velocity.

Porro, A. R.↗

Oscillating-flow regenerator test rig: Woven screen and metal felt results

We present correlating expressions, in terms of Reynolds or Peclet numbers, for friction factors, Nusselt numbers, enhanced axial conduction ratios, and overall heat flux ratios in four porous regenerator samples representative of stirling cycle regenerators: two woven screen samples and two random wire samples. Error estimates and comparison of data with others suggest our correlations are reliable, but we need to test more samples over a range of porosities before our results will become generally useful.

Gedeon, D.↗

A computational investigation of fuel mixing in a hypersonic scramjet

A parabolized, Navier-Stokes code, SHIP3D, is used to numerically investigate the mixing between air injection and hydrogen injection from a swept ramp injector configuration into either a mainstream low-enthalpy flow or a hypervelocity test flow. The mixing comparisons between air and hydrogen injection reveal the importance of matching injectant-to-mainstream mass flow ratios. In flows with the same injectant-to-mainstream dynamic pressure ratio, the mixing definition was altered for the air injection cases. Comparisons of the computed results indicate that the air injection cases overestimate the mixing performance associated with hydrogen injection simulation. A lifting length parameter, to account for the time a fluid particle transverses through the mixing region, is defined and used to establish a connection of injectant mixing in hypervelocity flows, based on nonreactive, low-enthalpy flows.

Fathauer, Brett W.↗

Oscillating-flow regenerator test rig

This report summarizes work performed in setting up and performing tests on a regenerator test rig. An earlier status report presented test results, together with heat transfer correlations, for four regenerator samples (two woven screen samples and two felt metal samples). Lessons learned from this testing led to improvements to the experimental setup, mainly instrumentation as well as to the test procedure. Given funding and time constraints for this project it was decided to complete as much testing as possible while the rig was set up and operational, and to forego final data reduction and analysis until later. Additional testing was performed on several of the previously tested samples as well an on five newly fabricated samples. The following report is a summary of the work performed at OU, with many of the final test results included in raw data form.