Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “first wall”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Computational Analysis of the Impact of Boundary Conditions on a Particle-Laden Flow: A Case Study in a Pressurized Oxy-Coal Combustor

Designing an effective burner is vital for the development of coal combustion technologies. Because of high pressure, the volumetric fraction of the coal particles in the injected fuel in a pressurized oxy-combustion (POC) burner approaches or even exceeds the limitations allowed by the commercial computational fluid dynamics codes (e.g., Ansys Fluent). Consequently, for such high particle volumetric fractions, the interplay between the particles, the fluid flow, and the burner wall needs to be re-evaluated. The present computational work is a first step in a systematic analysis of the roles of various characteristics involved in the POC process, such as the method of particle release, its location, and the particle size. Specifically, pulverized coal is burned under an elevated pressure of 15 bar in an O 2 /CO 2 environment. A 100 kW, a POC combustor, is modeled with Ansys Fluent using the Reynolds-averaged Navier−Stokes approach. It is revealed that for this pilot-scale, pressurized burner, the gas phase flow velocity in the near-wall region exhibits anomalies. With the major focus on POC, this work aims to eliminate/reduce the impact of high particle loading on the gas-phase flow. To scrutinize the role of particle loading in the near-wall region and eliminate the impact of this velocity on POC downstream, the particle−gas interplay in the boundary layer is investigated by means of the computational simulations incorporating the coupling between the turbulent flow and the particles. It is found that the tuning of the particle release location makes the gas-phase flow velocity in the presence of particles consistent with the pure gas flow velocity profile. The particles size is also found to have a significant impact on the particle trajectory.

CFD↗

Impact of particle size and particle-flow-wall coupling on pressurized oxy-combustion in the down-fired burner

Concerns over climate change have led to numerous efforts in developing low-carbon energy technologies. Pressurized oxy-combustion (POC) is a promising candidate to reduce carbon emissions in power generation. Designing an effective burner plays a vital role in developing new coal combustion technologies. Because of the high pressure, the volume fraction of coal particles at the fuel inlet of the burner of a pressurized oxy-combustor is close or even higher than the maximum limit that commercial CFD codes (e.g., ANSYS FLUENT) can handle. At this high particle volume fraction, the interactions among particles, fluid flow, and wall need to be re-evaluated. The present computational work is the first step of a systematic analysis of the particle influence, like releasing method, releasing locating, and particle size, in a pilot-scale POC combustor, developed at Washington University in St. Louis (WUSTL). In a POC process, pulverized coal is burned under elevated pressure and O2-CO2 environment. Specifically, a 15-bar, 100 kWth, POC combustor is modeled employing ANSYS FLUENT, using Reynolds-averaged Navier-Stokes (RANS) modeling. It is revealed that for this pilot-scale, pressurized burner, velocity profiles of the near-wall region in this POC facility exhibit some discrepancy against the near-wall turbulent flow velocity profile. In order to investigate the particle influence in the near-wall region, particle releasing location will be investigated. Numerical simulation results exhibit the coupling effect of turbulence flow and particles in this case. The particle size also demonstrates a great effect on particle trajectory, then further has an impact on flame stability and temperature.

Li, Lei↗

A numerical investigation of coal particle modeling for the inlet section of a pressurized oxy-combustion burner

Concerns over climate change have led to numerous efforts to develop low-carbon technologies, and pressurized oxy-combustion (POC) is a promising candidate to reduce carbon emissions in the power industry. Designing an effective burner for such technologies is vital for the development of these and other coal combustion technologies. Because of the high pressure, the volume fraction of coal particles at the fuel inlet of the pressurized oxy-combustor burner is close to or even higher than the maximum limit for commercial CFD codes (e.g., ANSYS FLUENT). At these high particle volume fractions, the interactions among particles, fluid flow and wall need to be re-evaluated. The present computational work is a first step in a systematic analysis of the influence of various parameters, like method of particle release, release location, and particle size, in a pilot-scale POC combustor, developed at Washington University in St. Louis (WUSTL). In the POC process, pulverized coal is burned under elevated pressure in an O2-CO2 environment. Specifically, a 15-bar, 100 kWth, POC combustor is modeled employing Ansys FLUENT commercial sodtware using the Reynolds-Averaged Navier-Stokes (RANS) approach. It is revealed that for this pilot-scale, pressurized burner, velocity profiles in the near-wall region exhibit some anomalies. In order to investigate the influence of particle loading in the near-wall region, particle release location was investigated. The numerical simulations incorporate the coupling between the turbulent flow and the particles. A sensitivity investigation of particle release location found that by tuning the release location, the velocity profile can be consistent with the pure gas flow velocity profile. More importantly, the particle releasing location also affects flame stability. Particle size was also found to have a significant impact on particle trajectory, flame stability and temperature. Finally, Large Eddy Simulations (LES) were performed and compared with the results from two-dimensional RANS.

Li, Lei↗

History of Ultrasonic Inspection of High-Level Waste Tanks at SRS - 20220

The Liquid Waste Disposition Projects (LWDP) Structural Authority and Inspection Engineering Support Group has teamed with the Materials Science and Technology Non-destructive Evaluation Group of Savannah River National Laboratory (SRNL) to implement a comprehensive In-Service Inspection (ISI) program for the High-Level Waste (HLW) tanks in the sites tank farms. The purpose of this program is to demonstrate the structural and leak integrity of the tanks to maintain the function of waste containment throughout the desired service life. Four types of waste tanks were constructed at Savannah River Site (SRS) from 1951 thru 1981 to store radioactive nuclear waste from the separations process. The Type I, II and III are carbon steel cylindrical tanks with varying degrees of access to the side walls and very limited access to the tank bottom. The tanks contain 750,000 to 1.3 million gallons of waste and are buried or backfilled with soil. The tanks are 75'-85' in diameter and 24'-33' from tank bottom to the tank roof. Inspection of the HLW tanks is made difficult by radiation, contamination, and small access openings. Through the years these challenges have been overcome by progressive improvements to programs and equipment resulting in the sophisticated wall crawler Ultrasonic Testing (UT) technology of today. A formal inspection program was developed and put in service in 1972. UT thickness measurements were first made in 1967 and 1969 of selected waste tanks using an analog-type instrument to measure the thickness of the carbon steel walls. Routine inspections for thinning were performed from 1972-1985 and then discontinued because no thinning had been observed and this technique could not detect pitting or cracking. UT inspections resumed in 1994 using a sophisticated robotic wall crawler with UT technology capable of detecting thinning, cracking and pitting. The current program focuses on the newer Type III tanks that are used primarily for storage. The program was upgraded in 2003 to include selected regions of the tank wall, secondary wall and annulus floor on a 7 to 10-year frequency. The facility is currently in its third cycle of tank inspections. Thus far, there have been no reportable indications of service induced degradation. This result provides assurance that the chemistry control program has been effective at mitigating corrosion and that the tanks remain structurally sound even after more than 40 years of service. This paper will present the UT technology first used at SRS and the evolution to the current systems and their capabilities. Additionally, plans for equipment upgrades that will improve the extent of inspection will be discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Visualization of lignification in flax stem cell walls with novel click-compatible monolignol analogs

As an essential part of plant cell walls, lignin provides mechanical support for plant growth, enhances water transport, and helps to defend against pathogens. As the most abundant natural aromatic-based renewable resource on earth, its biosynthesis has always been a research focus, and it is still currently under study. In this study, the p-coumaryl alcohol analog (H ALK ) and the coniferyl alcohol analog (G ALK ) containing an alkyne group at the ortho position were synthesized and applied to lignification in vivo and in vitro. The incorporation of these novel lignin monomers was observed via fluorescence imaging. It was found that the two monolignol analogs could be incorporated in dehydrogenated polymers (DHPs) in vitro and in flax cell walls in vivo. The results showed that as the cultivation time and precursor concentration varied, the deposition of H and G-type lignin exhibited differences in deposition mode. At the subcellular scale, the deposited lignin first appears in the cell corner and the middle lamella, and then gradually appears on the cell walls. Furthermore, lignin was also found in bast fiber. It was demonstrated that these new molecules could provide high-resolution localization of lignin during polymerization.

59 BASIC BIOLOGICAL SCIENCES↗

Flow in additively manufactured super-rough channels

Metal additive manufacturing has enabled geometrically complex internal cooling channels for turbine and heat exchanger applications, but the process gives rise to large-scale roughness whose size is comparable to the channel height (which is 500 $\mathrm {\mu }$ m). These super-rough channels pose previously unseen challenges for experimental measurements, data interpretation and roughness modelling. First, it is not clear if measurements at a particular streamwise and spanwise location still provide accurate representation of the mean (time- and plane-averaged) flow. Second, we do not know if the logarithmic layer survives. Third, it is unknown how well previously developed rough-wall models work for these large-scale roughnesses. To answer the above practical questions, we conduct direct numerical simulations of flow in additively manufactured super-rough channels. Three rough surfaces are considered, all of which are obtained from computed tomography scans of additively manufactured surfaces. The roughness’ trough to peak sizes are 0.1 $h$ , 0.3 $h$ and 0.8 $h$ , respectively, where $h$ is the intended half-channel height. Each rough surface is placed opposite a smooth wall and the other two rough surfaces, leading to six rough-wall channel configurations. Two Reynolds numbers are considered, namely $Re_\tau =180$ and $Re_\tau =395$ . We show first that measurements at one streamwise and spanwise location are insufficient due to strong mean flow inhomogeneity across the entire channel, second that the logarithmic law of the wall survives despite the mean flow inhomogeneity and third that the established roughness sheltering model remains accurate.

Altland, Samuel↗

Cold plate with combined inclined impingement and ribbed channels

Heat transfer devices and methods for making the same that include a first enclosure having at least one inlet port; a second enclosure having a bottom plate and one or more dividing walls to establish channels, at least one internal surface of each channel having rib structures to create turbulence in a fluid flow; and a jet plate connecting the first enclosure and the second enclosure having impinging jets that convey fluid from the first enclosure to the channels, said impinging jets being set at an angular deviation from normal to cause local acceleration of fluid and to increase a local heat transfer rate.

42 ENGINEERING↗

Enhancing the Electrode Gravimetric Capacity of Li 1.2 Mn 0.4 Ti 0.4 O 2 Cathode Using Interfacial Carbon Deposition and Carbon Nanotube-Mediated Electrical Percolation

Mn-based cation disordered rocksalt oxides (Mn-DRX) are emerging as promising cathode materials for next-generation Li-ion batteries due to their high specific capacities and cobalt and nickel free characteristic. However, to reach the theoretical capacity, solid-state method synthesized Mn-DRX materials require activation via post-synthetic ball milling, typically incorporating more than 20 wt.% conductive carbon that adversely reduces the electrode level gravimetric capacity. To solve this issue, we firstly deposit amorphous carbon on the surface of the Li 1.2 Mn 0.4 Ti 0.4 O 2 (LMTO) particles to increase the electrical conductivity by a five order of magnitude. Although the cathode material gravimetric first charge capacity reaches 180 mAh/g, its highly irreversible behavior leads to a 70 mAh/g first discharge capacity. Subsequently, to ensure a good electrical percolation network, the LMTO material is ball milled with multi-wall carbon nanotube (CNT) to obtain a 78.7 wt.% LMTO active material loading in the cathode electrode (LMTO-CNT). As a result, a 210 mAh/g cathode electrode gravimetric first charge and 165 mAh/g first discharge capacity are obtained, compared to the respective capacity values of 222 mAh/g and 155 mAh/g for the LMTO ball milled with 20 wt.% SuperP C65 electrode (LMTO-SP). After 50 cycles, the LMTO-CNT delivers a 121 mAh/g electrode gravimetric discharge capacity, largely outperforming the 44 mAh/g value of the LMTO-SP. In conclusion, our study demonstrates that while ball milling is necessary to achieve the theoretical capacity of LMTO, a careful selection of the additive, such as CNT, effectively reduces the required carbon quantity to achieve a higher electrode gravimetric discharge capacity.

25 ENERGY STORAGE↗

Imaging of Electrothermal Filament Formation in a Mott Insulator

Resistive switching—the current- and voltage-induced change of electrical resistance—is at the core of memristive devices, which play an essential role in the emerging field of neuromorphic computing. This study is about resistive switching in a Mott insulator, which undergoes a thermally driven metal-to-insulator transition. Two distinct switching mechanisms are reported for such a system: electric-field-driven resistive switching and electrothermal resistive switching. The latter results from an instability caused by Joule heating. Here, we present the visualization of the reversible resistive switching in a planar V 2 O 3 thin-film device using high-resolution wide-field microscopy in combination with electric transport measurements. We investigate the interaction of the electrothermal instability with the strain-induced spontaneous phase separation in the V 2 O 3 thin film at the Mott transition. The photomicrographs show the formation of a narrow metallic filament with a minimum width ≲500 nm. Although the filament formation and the overall shape of the current-voltage characteristics (IVCs) are typical of an electrothermal breakdown, we also observe atypical effects such as oblique filaments, filament splitting, and hysteretic IVCs with sawtoothlike jumps at high currents in the low-resistance regime. We are able to reproduce the experimental results in a numerical model based on a two-dimensional resistor network. This model demonstrates that resistive switching in this case is indeed electrothermal and that the intrinsic heterogeneity is responsible for the atypical effects. This heterogeneity is strongly influenced by strain, thereby establishing a link between switching dynamics and structural properties.

42 ENGINEERING↗

Electronic nature of chiral charge order in the kagome superconductor CsV 3 Sb 5

Kagome superconductors with T C up to 7 K have been discovered for over 40 y. Recently, unconventional chiral charge order has been reported in kagome superconductor KV 3 Sb 5 , with an ordering temperature of one order of magnitude higher than the T C . However, the chirality of the charge order has not been reported in the cousin kagome superconductor CsV 3 Sb 5 , and the electronic nature of the chirality remains elusive. In this paper, we report the observation of electronic chiral charge order in CsV 3 Sb 5 via scanning tunneling microscopy (STM). We observe a 2 × 2 charge modulation and a 1 × 4 superlattice in both topographic data and tunneling spectroscopy. 2 × 2 charge modulation is highly anticipated as a charge order by fundamental kagome lattice models at van Hove filling, and is shown to exhibit intrinsic chirality. We find that the 1 × 4 superlattices form various small domain walls, and can be a surface effect as supported by our first-principles calculations. Crucially, we find that the amplitude of the energy gap opened by the charge order exhibits real-space modulations, and features 2 × 2 wave vectors with chirality, highlighting the electronic nature of the chiral charge order. STM study at 0.4 K reveals a superconducting energy gap with a gap size 2Δ = 0.85 meV, which estimates a moderate superconductivity coupling strength with 2Δ/k B T C = 3.9. Furthermore, when further applying a c-axis magnetic field, vortex core bound states are observed within this gap, indicative of clean-limit superconductivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Efficient Thermal Energy Storage with Radial Flow in Packed Beds

Thermal energy storage (TES) is a way to store excess heat in order to generate power later. These types of systems are valuable in the solar industry, where power production can still occur when sunlight is not available. This not only increases system flexibility, it drives down the cost of electricity. One option to store thermal energy is with a packed bed where the storage media resides in a cylindrical container. Flow from one end of the cylinder to the other deposits or recovers heat (axial flow). While a promising technology in terms of energy storage, it exhibits a high pressure drop that lowers overall system efficiency. This project seeks to flow the heat transfer fluid through the storage media in the radial direction. This system offers the potential to retain reasonable thermal performance while substantially lowering the pressure drop. The overall goal was to assess the performance of radial flow experimentally and numerically. Three main designs were considered in this work. The first system utilized a central pipe and four receiving pipes near the wall. The second system utilized a central pipe and an annulus with holes near the wall. The last approach considered segmenting the bed so only select zones would receive flow in the radial direction. In a high-aspect ratio system, the hole patterns in the piping are important for ensuring even flow into the bed, and a major design effort was testing holes patterns to promote even flow. The four pipe system was shown to be not feasible, as preferential flow paths occur that do not allow even and full heating of the packed bed. The annular system can lead to even flow, but the results show this is better accomplished through larger piping instead of considering variations in the hole pattern along the axial length of the pipe. Segmenting the bed can lead to similar exergetic performance when compared to axial or radial flow. However, the pressure drop in the segmented design is likely too high for practical implementation. A baseline commercial design showed exergetic efficiencies for axial, radial, and radial segments of 81.6%, 82.8%, and 80.2%, respectively. Pressure drop for the axial and radial results were 2.36 psi and 2.45 psi, respectively, with segments being nearly an order of magnitude higher. At these large scales, the aspect ratio of the system is important. From a baseline of 0.64, an aspect ratio of 0.32 for radial flow showed an exergetic efficiency of 86% but a pressure drop of 5.39 psi. All of these results provide new insights into packed bed thermal energy storage with radial flow. Competing effects must be considered when designing a radial system, and results show a radial design can show strong thermal results at the expense of system efficiencies from pressure drop. The COMSOL models used in this analysis are available to the public and other researchers. Public benefits include a potential increase in the efficiency of packed bed thermal energy storage. Higher efficiency in storage promotes green energy technologies while reducing costs.

14 SOLAR ENERGY↗

c-HAND: near real-time coastal flood mapping

The Texas Gulf Coast region contains significant centers of population, infrastructure, and economy and is threatened by intensifying tropical storms. The flooding from these tropical storms often has multiple compounding drivers. This characteristic presents a complex numerical problem where a simulation must consider multiple hydrologic forcings. While several procedures exist for addressing this problem numerically, they tend to be resource-intensive and cannot be conducted in near real-time. We extend GeoFlood, a reduced physics approach for fluvial flood forecasting, to rapidly predict coastal and compound fluvial-coastal inundation. This method is validated against a numerical ocean circulation model (ADCIRC) simulation of Hurricane Ike, a major coastal flooding event that happened on the Texas Gulf Coast in 2008. We show that the inundation map generated by coastal HAND (c-HAND) has reasonable agreement with the ADCIRC simulation while taking about 1.7% of the time currently needed to run ADCIRC on a supercomputer. While our model correctly predicts 99% of ADCIRC-inundated DEM cells, it also overpredicts inundated area by a factor of approximately 27%. We combine c-HAND with the GeoFlood framework for fluvial flood forecasting to create a compound fluvial-coastal inundation mapping workflow that can be run in near real-time. c-HAND's fast wall-clock time and low CPU requirements can support decision making by first response personnel. The method provides timely and convenient access to crucial information, such as the locations of flooded roads and inundated coastal areas.

42 ENGINEERING↗

Project Plan: Salt in Situ Heater Test

This project plan gives a high-level description of the US Department of Energy Office of Nuclear Energy (DOE-NE) Spent Fuel and Waste Disposition (SFWD) campaign in situ borehole heater test project planned for the Waste Isolation Pilot Plant (WIPP) site, titled the Brine Availability Test in Salt (BATS). BATS is the first stage in a planned sequence of tests to bolster the technical basis for disposal of heat generating waste in salt. This plan provides an overview of the schedule and responsibilities of the parties involved. This project is a collaborative effort by Sandia, Los Alamos, and Lawrence Berkeley National Laboratories to execute a series of small-diameter borehole heater tests in salt for the DOE-NE SFWD campaign. Design of a heater test in salt at WIPP has evolved over several years. The experiment has begun in January 2020 and the first phase will continue for several months with the possibility for follow on testing. BATS comprises a suite of modular tests, which consist of a group of adjacent horizontal boreholes in the wall of drifts at WIPP. Each test is centered around a packer-isolated heated borehole (12.2 cm [4.81 diameter) containing equipment for water-vapor collection and borehole closure monitoring, surrounded by smaller-diameter (up to 5.3 cm [2.11 diameter) satellite observation boreholes. Observation boreholes contain grouted-in temperature sensors, electrical resistivity tomography (ERT) sensors, and fiber optics; packer-isolated tracer release and sampling intervals; and acoustic emission (AE) piezoelectric sensors. A larger-diameter (12.2 cm [4.81) satellite borehole includes sorel and salt cement plugs, as part of an engineered barrier sealing test. The first two tests, to be implemented in parallel, are heated (target borehole wall temperature of 120 °C) and unheated, with similar arrays of observation borehole monitoring changes. Follow-on tests will be designed using information gathered from the first two tests, and may be conducted at other borehole wall temperatures, use multiple observation boreholes, and may include different measurement types and test designs. This 2020 update of the original 2018 project plan satisfies DOE-NE Spent Fuel and Waste Science and Technology (SFWST) milestone M3SF-205N010303034, as part of the SNL "Salt Disposal R&D" work package.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Real-time simulation of asymmetry generation in fermion-bubble collisions

Motivated by the out-of-equilibrium dynamics during an early-Universe first-order phase transition, we perform real-time simulations of fermion-bubble scattering in 1 + 1 dimensions. This nonequilibrium process can generate a charge-conjugation C asymmetry outside the bubble wall, induced by the complex fermion mass profile. The resulting C asymmetry is the 1 + 1 -dimensional analog of the C P asymmetry in 3 + 1 dimensions, a key ingredient in baryon asymmetry generation at the electroweak scale. Using tensor network methods, we track the real-time evolution of the C asymmetry in the charge density as the fermion interacts with the bubble wall, a regime inaccessible to analytic calculations. We further introduce two observables to quantify the asymmetry in the asymptotic region where reflected particles are well separated from the scattering point: one based on the net charge outside the bubble wall, and the other on the spatial displacement between the reflected particle and antiparticle wave packets. Our study represents a first step toward nonperturbative, real-time computations of C P asymmetry in 3 + 1 dimensions for electroweak baryogenesis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the onset of nucleate boiling in liquid xenon

We report the first precision measurement of the superheat temperature required for bubble nucleation in liquid xenon of Δ T wall,ONB = (16.9±0.5) K and Δ T wall,ONB = (19.2 +0.4 -1.1 ) K at pressures of P = (0.98±0.02) bar and P = (1.32 +0.05 -0.01 ) bar, respectively. Both are measured at a subcooled bulk fluid temperature of ~ 162 K. A dedicated liquid xenon setup is used to measure the temperature at which bubble nucleation first appears on the flat surface of a resistor. The associated average heat flux at the surface of the resistor is determined using fluid dynamics simulations. Future experiments can use these experimental results to determine the likelihood of boiling in liquid xenon and to design effective thermal sinks that prevent bubble nucleation.

47 OTHER INSTRUMENTATION↗

Optical fiber receptacle cover

A cover for partially covering and protecting cables plugged into a receptacle is provided. The receptacle includes a face plate with a first hole through which a first fastener secures the face plate to a face of the receptacle. The cover comprises a plurality of walls at least partially defining a hollow chamber, a slot adjacent to the chamber and configured to receive the face plate when the cover is slid over the face plate, an opening that leads to the chamber and the slot, and a first channel extending partially through the chamber and configured to provide access to the fastener.

42 ENGINEERING↗

Distinguishing Mesoscale Polar Order (Unidirectional vs Bidirectional) of Cellulose Microfibrils in Plant Cell Walls Using Sum Frequency Generation Spectroscopy

Cellulose in plant cell walls are synthesized as crystalline microfibrils with diameters of 3–4 nm and lengths of around 1–10 μm. These microfibrils are known to be the backbone of cell walls, and their multiscale three-dimensional organization plays a critical role in cell wall functions including plant growth and recalcitrance to degradation. The mesoscale organization of microfibrils over a 1–100 nm range in cell walls is challenging to resolve because most characterization techniques investigating this length scale suffer from low spatial resolution, sample preparation artifacts, or inaccessibility of specific cell types. Here, we report a sum frequency generation (SFG) study determining the mesoscale polarity of cellulose microfibrils in intact plant cell walls. SFG is a nonlinear optical spectroscopy technique sensitive to the molecular-to-mesoscale order of noncentrosymmetric domains in amorphous matrices. However, the quantitative theoretical model to unravel the effect of polarity in packing of noncentrosymmetric domains on SFG spectral features has remained unresolved. In this work, we show how the phase synchronization principle of the SFG process is used to predict the relative intensities of vibrational modes with different polar angles from the noncentrosymmetric domain axis. Applying this model calculation for the first time and employing SFG microscopy, we found that cellulose microfibrils in certain xylem cell walls are deposited unidirectionally (or biased in one direction) instead of the bidirectional polarity which was believed to be dominant in plant cell walls from volume-averaged characterizations of macroscopic samples. Here, with this advancement in SFG analysis, one can now determine the relative polarity of noncentrosymmetric domains such as crystalline biopolymers interspersed in amorphous polymer matrices, which will open opportunities to study new questions that have not been conceived in the past.

36 MATERIALS SCIENCE↗

Impact of Janssen effect on thermal transport in granular flow

Using a modulated photothermal radiometry (MPR) technique capable of measuring thermal transport in particle beds, we find asymptotically increasing effective thermal conductivity and decreasing near-wall thermal resistance along gravity-driven downward granular flows through a 1-meter-long narrow vertical channel owing to the Janssen effect. The Janssen effect is confirmed by similar asymptotic trends from particle bed apparent mass measurements as well as separate MPR heat transfer measurements on stationary particle beds under compression at different heights of the channel with and without pressure screening. Furthermore, local heat transfer coefficient along the 1-meter-long channel was modeled based on measured spatially resolved thermal conductivity and near-wall thermal resistance due to the Janssen effect. This work reveals for the first time the impact of the over century-old Janssen effect on heat transfer in granular media. Furthermore, the results from this work can lead to a better understanding of heat transfer in granular flow.

14 SOLAR ENERGY↗