Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “exposure time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Influence of a constant magnetic field on the fibrinogen-fibrin system

The effect of a constant magnetic field with a strength of 2500 oersteds on the fibrinogen-fibrin system was studied in the organism of healthy rabbits with exposure times of 1 and 5 hours. The results obtained indicate disruptions in the stage of conversion of fibrinogen to fibrin and an increase in the amount of fibrinogen.

Matskevichene, V. B.↗

Applications of cryogenics in electron microscopy

Description of research and development efforts which resulted in a high-voltage cryoelectron microscope system capable of consistent operation at 1.8 to 4.2 K. Attention is given to the design and operation of superconducting objective lenses providing enhanced resolution during longer exposure times at lower beam intensities (thus reducing radiation damage of specimens). A specific system described combines a closed-cycle superfluid helium refrigerator integrated with a modified 200 kV electron microscope. Consistent resolutions of 8 to 16 A are attained with significantly reduced radiation damage, contamination, and thermal noise in prolonged vibration-free examination of specimens at temperatures from 1.8 to 4.2 K. Applications in specific disciplines are discussed, including membrane ultrastructure, cryobiology, microelectronics, and general superconductivity research.

Fernandez-Moran, H.↗

Surface history of lunar soil and soil columns

Measurements of cosmic ray track densities are presented for soil samples from Apollo 15, 16, and 17. Median track densities are used to infer total effective exposure times within about 15 cm of the lunar surface. Minimum track densities are used to derive the time of the last impact-produced rearrangement of soil grains. For samples from near various craters ages are derived of 40 m.y. for St. George, 6 (plus or minus 3) m.y. for S. Ray, 25 to 90 m.y. for Plum, and 20 to 35 m.y. for Shorty. The material of 15003, the Apollo 15 deep core at depths of 120 to 160 cm, is inferred to have been deposited at an average rate greather than or equal to 0.35 cm/m.y. The Apollo 16 core at 41 to 47 cm depths, 60007, appears to be well mixed and was covered up by deposition at greater than 0.3 cm/m.y. for the next few m.y. after its deposition.

Fleischer, R. L.↗

A study of the diffusional behavior of a two-phase metal matrix composite exposed to a high temperature environment

The progress of diffusion-controlled filament-matrix interaction in a metal matrix composite where the filaments and matrix comprise a two-phase binary alloy system was studied by mathematically modeling compositional changes resulting from prolonged elevated temperature exposure. The analysis treats a finite, diffusion-controlled, two-phase moving-interface problem by means of a variable-grid finite-difference technique. The Ni-W system was selected as an example system. Modeling was carried out for the 1000 to 1200 C temperature range for unidirectional composites containing from 6 to 40 volume percent tungsten filaments in a Ni matrix. The results are displayed to show both the change in filament diameter and matrix composition as a function of exposure time. Compositional profiles produced between first and second nearest neighbor filaments were calculated by superposition of finite-difference solutions of the diffusion equations.

Tenney, D. R.↗

Effect of weightlessness on mineral saturation of bone tissue

X-ray photometry of bone density established dynamic changes in mineral saturation of bone tissues for Soyuz spacecraft and Salyut orbital station crews. Calcaneus optical bone densities in all crew members fell below initial values; an increase in spacecrew exposure time to weightlessness conditions also increased the degree of decalcification. Demineralization under weightlessness conditions took place at a higher rate than under hypodynamia.

Krasnykh, I. G.↗

Planetary investigation utilizing an imaging spectrometer system based upon charge injection technology

An intrinsic silicon charge injection device (CID) television sensor array has been used in conjunction with a CaMoO4 colinear tunable acousto optic filter, a 61 inch reflector, a sophisticated computer system, and a digital color TV scan converter/computer to produce near IR images of Saturn and Jupiter with 10A spectral resolution and approximately 3 inch spatial resolution. The CID camera has successfully obtained digitized 100 x 100 array images with 5 minutes of exposure time, and slow-scanned readout to a computer. Details of the equipment setup, innovations, problems, experience, data and final equipment performance limits are given.

Wattson, R. B.↗

Surface history of some Apollo 17 lunar soils

Cosmic ray track densities in Apollo 17 soil samples are used to infer surface exposure times of soils from a trench at Van Serg Crater, from on and near a boulder at Camelot Crater, and from the position of the heat flow and neutron flux experiments (the ALSEP site). The topmost 2 cm of soil at Van Serg was exposed for 11 m.y., the top cm at Camelot for 36 m.y. A layering chronology and average deposition rate are proposed for the trench. For all soils the median track densities imply predispositional irradiation in the top 15 cm of the lunar surface for times that were long compared with the actual residence in the stratigraphic positions from which the soils were collected. Van Serg crater is inferred to have been formed approximately 24 m.y. ago.

Fleischer, R. L.↗

Spatially multiplexed infrared camera

A spatially multiplexed infrared camera is described. The camera records an image by measuring the coefficients of an orthogonal series expansion of the two-dimensional radiance distribution. By choice of appropriate functions, significant gains in the picture signal-to-noise ratio can be realized. We have constructed a camera utilizing this multiplexing principle to record images of astronomical objects at infrared wavelengths, where conventional scanning systems perform badly because of low signal levels. Test results verify that the camera exhibits the increase of efficiency expected of a multiplexing system, allowing exposure times two orders of magnitude shorter than necessary for comparable scanning systems.

Davies, D. W.↗

On the Age of Cosmic Rays as Derived from the Abundance of Be-10

The isotopic composition of cosmic ray Be, B, C, and N was studied using a new range versus total light technique. Special emphasis was placed on the Be isotopes and in particular, on the radioactive isotope Be-10 due to its mean lifetime against decay. The experiment consisted of a thin trigger scintillator, an acrylic plastic Cerenkov detector and a spark chamber, followed by a totally active stack of 14 scintillation detectors. This stack of scintillators made possible the measurement of range, and also permitted the removal of interacting events by continuously monitoring their identities along their trajectories. The experiment was carried by balloon to atmospheric depths ranging from 3.5 to 5.0 g sq cm residual atmosphere for a total exposure time of 23 hr. Results indicate the survival of ( 55 + or -21) % of the Be-10 in the arriving cosmic rays; the data were interpreted using the leaky box model of cosmic ray propagation.

Hagen, F. A.↗

Luminosity and astrometry of comets: A review

Visual and photographic observations of the brightness of comets are reviewed including methods and sources of errors. Nuclear magnitude estimates are discussed and interpreted in relation to determination of appropriate exposure times for photographic observations. The importance of brightness ephemarides is emphasized.

Roemer, E.↗

Photography and photometry of the near infrared OH airglow

The instruments employed in the investigation were modified for aircraft use primarily by automating the repetitive measurements and incorporating image intensifier tubes to reduce exposure times. The instruments include a 35-mm camera, an absolutely calibrated photometer, and a 16-mm movie camera. The data obtained will be used in a study of the variation of parallax emission heights with geographical location, and the relationship of OH patch or stripe size to emission height.

Peterson, A. W.↗

Dynamic oxidation behavior of TD-NiCr alloy with different surface pretreatments

Oxidation tests of TD-NiCr alloy with different surface pretreatments were conducted in a Mach-5 arc-jet at 1200 C and 0.002 lb/sec flowing air environment. The mechanisms responsible for the observed oxidation behavior are examined. The presence of atomic oxygen in the air stream plays a significant role in determining the oxidation characteristic of the alloy. The rate of Cr2O3 vaporization by formation of volatile CrO3 is greatly enhanced by the flowing conditions. The typical microstructure of oxides formed in the dynamic tests consists of an external layer of NiO with a porous mushroom-type morphology, an intermediate layer of NiO and Cr2O3 oxide mixture, and a continuous inner layer of Cr2O3 in contact with the Cr-depleted alloy substrate. Three basic processes underlying the formation of mushroom-type NiO are identified and discussed. The oxidation rate is determined by the rate of vaporization of NiO. Surface pretreatment has a significant effect on the oxidation behavior of the alloy in the early stage of oxidation, but becomes less important as exposure time increases. Mechanical polishing induces surface recrystallization, but promotes the concurrence of external growth of NiO and internal oxidation of the alloy in the dynamic atmosphere.

Young, C. T.↗

Electronic system for optical shutter control

The paper describes a precise and versatile electronic system for shutter control in light beam experiments. Digital and analog circuitry is used to provide automatic timing, exposure control, manual operation, and remote programmability. A block diagram of the system is presented and the individual circuits - the timer control circuit, the clock control circuit, the comparator circuit, the exposure (integrator) circuit, and the shutter drive circuit are discussed in detail and diagrams are provided.

Viljoen, H. C.↗

The effect of instrument performance upon the calculated spectrum from a spaceborne IR interferometer

The data processing equations used to transform an interferometer output signal into a spectrum have been applied to the instrument noise to find the relationship between the signal to noise ratio (S/N) in the interferogram and that in the computed spectrum. Both photon and thermal noises have been taken into account. The results show that the voltage S/N in the spectrum is inversely proportional to the square root of the number of samples so that taking a larger number of samples requires a larger S/N in the interferogram to achieve the same S/N in the spectrum. Numerical examples are given relating the exposure time to design and performance parameters for stellar and atmospheric applications.

James, D. A.↗

Quantitative three-dimensional dynamic imaging of structure and function of the cardiopulmonary and circulatory systems in all regions of the body

The background for, and design of a third generation, general purpose, all electronic spatial scanning system, the DSR is described. Its specified performance capabilities provide dynamic and stop action three dimensional spatial reconstructions of any portion of the body based on a minimum exposure time of 0.01 second for each 28 multiplanar 180 deg scanning set, a maximum scan repetition rate of sixty 28 multiplane scan sets per second, each scan set consisting of a maximum of 240 parallel cross sections of a minimum thickness of 0.9 mm, and encompassing a maximum cylindrical volume about 23 cm in length and up to 38 cm in diameter.

Sturm, R. E.↗

Summer performance results obtained from simultaneously testing ten solar collectors outdoors

Ten solar collectors were simultaneously tested outdoors. Efficiency data were correlated using a method that separates solar variables (flux, incident angle) from the desired performance parameters (heat loss, absorbtance, transmittance) which are unique to a given collector design. Tests were conducted on both clear and moderately cloudy days. Correlating data in the above manner, a 2-glass, black paint collector exhibited a decrease in efficiency of 5 percentage points relative to the baseline data for an exposure time of 2 years, 4 months. Condensation on the collector glazing was thought to be a contributing factor in this efficiency change.

Miller, D. R.↗

TV system considerations for the Space Telescope

The Space Telescope, designed as a permanent observatory in space, will be launched into orbit, maintained, and refurbished by the Space Shuttle. One of the primary instruments to fly with the telescope is the f/24 Camera. The camera's mission requirements and their impact on the choice and design of a television system are discussed, along with the system engineering aspects of the TV system design and spacecraft design. An SEC type television camera tube was selected as the primary data acquisition sensor, because of its ability to accommodate exposure times of several hours with only modest cooling.

Lowrance, J. L.↗

The Stanford-Ames portable echocardioscope - A case study in technology transfer

The paper describes a lightweight portable battery-powered echocardioscope fabricated largely from readily available components. The transducer contains a piezoelectric crystal which acts as both an ultrasound pulse emitter and echo receiver, and the oscilloscope is of modular construction. The oscilloscope display can be produced in any of three different modes: A-mode, B-mode, and M-mode (time-motion) by sweeping the intensified points of light of the B-mode display vertically along the oscilloscope face. The resulting display can be photographed in a time exposure, thus providing a hardcopy record for the patient's chart or physician's records. The device is clinically validated on both normal subjects and patients by experienced echocardiographers.

Schmidt, G.↗