Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “exposure time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Decarburization and Carburization Behavior of Grade 91 Steel in Sodium Environments

Two heats of G91 steel have been investigated in sodium at 550-650°C to understand its corrosion behaviour, microstructural evolution, and tensile properties. Sodium exposure tests of subsized tensile and coupon specimens of G91 base metal and weldment were conducted in Argonne’s forced convection sodium materials testing loops. Maximum exposure times of ~39,000 h at 550°C, ~37,000 h at 600°C, and ~20,000 h at 650°C have been achieved, respectively. Thermal aging experiments of G91 steel were conducted in parallel, and the data of the sodium-exposed specimens were compared with the thermal aging data of the same heat to isolate the thermal aging effect from the effect of sodium exposure. It was found that the tensile strength of G91 steel can be reduced by more than 50% after sodium exposures at 650°C. The effect of a sodium environment on tensile properties is largely dependent on the carburization/decarburization behavior of G91 steel exposed to sodium. The carbon concentrations in sodium in Argonne’s SMT-1 and SMT-2 loops were determined by the equilibration method. The carbon activity in sodium was established by equilibrating high-purity nickel in sodium, analyzing the material for carbon, and using the reported data on the carbon solubility for this material. The carbon activity results were combined with the carbon solubility data in sodium to establish the carbon concentration in sodium. The carbon concentrations in the SMT-1 and SMT-2 loop were estimated to be 1.23 and 0.25 ppm, respectively. With this initial success, we will continue to monitor the carbon contents in the two loops to correlate the microstructural and mechanical property changes with the sodium purity. Future experiments will also consider sodium exposure tests in controlled carbon activities. Online monitoring and control of carbon contents in sodium in nuclear reactors would also be of interest. Thermodynamic analysis was conducted to understand the carburization-decarburization behavior of G91 steel exposed to sodium in the SMT-1 and SMT-2 loops. The equilibrium carbon activity in the alloy was evaluated by the thermodynamics of M 23 C 6 carbides. The calculated carburization-decarburization boundary showed that G91 would undergo decarburization at 650°C in the SMT-1 loop and carburization at 600°C in the SMT-2 loop, which is consistent with our findings from the sodium exposure tests. Future work will include thermodynamic analysis of the carbon concentration – activity relationship including the effect of carbide-forming elements, vanadium and niobium in G91 steel. Kinetics of carbon diffusion and the effect on microstructure and mechanical performance under various service conditions will also be investigated. The ultimate goal is to understand the mechanisms and the kinetics of carbon transfer in the sodium-steel system and to provide a basis for predicting the effect of long-term decarburization-carburization process on the integrity of reactor components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Low-Pressure Cold Plasma for Disinfection of ISS Grown Produce and Metallic Instrumentation

Cold plasma (CP) cleaning is a dry, non-thermal process, which can provide broad-spectrum antimicrobial activity yet reportedly causes little to no damage to the object being sanitized. Since cold plasma uses no liquids, it has the distinct advantage when used in microgravity of not having to separate liquids from the item being cleaned. This paper will present results on an effort to use low pressure CP to disinfect or sterilize materials for in space applications. Exposure times from 0 to 60 minutes and pressures ranging from 0.10 to 1.0 mbar were used to optimize plasma parameters. Tests were done on produce and metal coupons to simulate medical equipment. Escherichia coli was used as the challenge organism on produce and Bacillus pumilus SAFR-32 was used on metal surfaces. Produce testing was not successful, with unacceptable kill rates and the produce being negatively impacted by exposure to the plasma. The plasma caused a 5 log reduction in the number of viable bacteria on metal coupon tests, which placed the number of viable bacteria below the detection limit. This is a very promising result showing that sterilization of medical equipment with cold plasma is feasible. Scanning Electron Microscope images were taken before and after exposure. The images after plasma exposure show that the bacteria spores have been physically affected, as their size has gotten smaller and their appearance has changed.

Hintze, Paul E.↗

Development of Cable Aging Acceptance Criteria for Nuclear Facilities

The aging of nuclear power plant electrical cables has been the subject of substantial research and development (R&D) projects in the nuclear industry, national and international laboratories, universities, and vendor organizations for several years. More specifically, these R&D efforts were conducted to develop equipment and techniques for assessing age-related degradation of in-service cables in nuclear facilities including power plants, research reactors, waste facilities and fuel fabrication plants. In recent years, cable R&D efforts in the nuclear arena have also included work to develop new cables for the next generation of reactors. Over time, exposure to harsh environmental conditions such as elevated temperatures, radiation, and humidity in nuclear installations can result in age-related degradation and failure of cables. In the current fleet of nuclear reactors, there are thousands of miles of cabling installed in each plant and many of these cables are exposed to these harsh environmental conditions. For these cables, the jacket and insulation polymers harden and become brittle over time, making them more susceptible to crack formation and growth, moisture intrusion, and other mechanisms that can lead to cable failure. Moreover, the existing U.S. fleet of 98 nuclear reactors has an average operating age of 38 years. Many of these nuclear power plants have applied for and almost all have been granted regulatory approval for license renewals to operate for 60 years, 20 years beyond their original 40-year life. Further, subsequent license renewals (SLRs) are underway with a few commercial nuclear power sites already approved to operate up to 80 years. As these reactors pursue operating life extensions, utilities must find a way to address issues associated with age-related degradation of cables. Designers of small modular reactors are also in need of technologies to evaluate the performance of cables that will be installed in harsher environments (e.g. higher temperatures, radiation doses, dose rates, etc.) than those present in current-generation reactors. Today, a variety of cable condition monitoring (CM) techniques have been developed and successfully used in nuclear facilities. These techniques are used to identify age-related degradation and assess the condition of cables to determine if their performance characteristics have changed with age. However, objective criteria must be developed for these CM tests to help quantify cable condition and thereby develop repair and replacement schedules. With operating life extending to 80 years and more SLRs on the horizon, both nuclear facilities and regulators need an objective means to determine the aged condition of cables.

36 MATERIALS SCIENCE↗

Development of Cable Aging Acceptance Criteria for Nuclear Facilities

The aging of nuclear power plant electrical cables has been the subject of substantial research and development (R&D) projects in the nuclear industry, national and international laboratories, universities, and vendor organizations for several years. More specifically, these R&D efforts were conducted to develop equipment and techniques for assessing age-related degradation of in-service cables in nuclear facilities including power plants, research reactors, waste facilities and fuel fabrication plants. In recent years, cable R&D efforts in the nuclear arena have also included work to develop new cables for the next generation of reactors. Over time, exposure to harsh environmental conditions such as elevated temperatures, radiation, and humidity in nuclear installations can result in age-related degradation and failure of cables. In the current fleet of nuclear reactors, there are thousands of miles of cabling installed in each plant and many of these cables are exposed to these harsh environmental conditions. For these cables, the jacket and insulation polymers harden and become brittle over time, making them more susceptible to crack formation and growth, moisture intrusion, and other mechanisms that can lead to cable failure. Moreover, the existing U.S. fleet of 98 nuclear reactors has an average operating age of 38 years. Many of these nuclear power plants have applied for and almost all have been granted regulatory approval for license renewals to operate for 60 years, 20 years beyond their original 40-year life. Further, subsequent license renewals (SLRs) are underway with a few commercial nuclear power sites already approved to operate up to 80 years. As these reactors pursue operating life extensions, utilities must find a way to address issues associated with age-related degradation of cables. Designers of small modular reactors are also in need of technologies to evaluate the performance of cables that will be installed in harsher environments (e.g. higher temperatures, radiation doses, dose rates, etc.) than those present in current-generation reactors. Today, a variety of cable condition monitoring (CM) techniques have been developed and successfully used in nuclear facilities. These techniques are used to identify age-related degradation and assess the condition of cables to determine if their performance characteristics have changed with age. However, objective criteria must be developed for these CM tests to help quantify cable condition and thereby develop repair and replacement schedules. With operating life extending to 80 years and more SLRs on the horizon, both nuclear facilities and regulators need an objective means to determine the aged condition of cables.

36 MATERIALS SCIENCE↗

Development of a portable multispectral thermal infrared camera

The purpose of this research and development effort was to design and build a prototype instrument designated the 'Thermal Infrared Multispectral Camera' (TIRC). The Phase 2 effort was a continuation of the Phase 1 feasibility study and preliminary design for such an instrument. The completed instrument designated AA465 has application in the field of geologic remote sensing and exploration. The AA465 Thermal Infrared Camera (TIRC) System is a field-portable multispectral thermal infrared camera operating over the 8.0 - 13.0 micron wavelength range. Its primary function is to acquire two-dimensional thermal infrared images of user-selected scenes. Thermal infrared energy emitted by the scene is collected, dispersed into ten 0.5 micron wide channels, and then measured and recorded by the AA465 System. This multispectral information is presented in real time on a color display to be used by the operator to identify spectral and spatial variations in the scenes emissivity and/or irradiance. This fundamental instrument capability has a wide variety of commercial and research applications. While ideally suited for two-man operation in the field, the AA465 System can be transported and operated effectively by a single user. Functionally, the instrument operates as if it were a single exposure camera. System measurement sensitivity requirements dictate relatively long (several minutes) instrument exposure times. As such, the instrument is not suited for recording time-variant information. The AA465 was fabricated, assembled, tested, and documented during this Phase 2 work period. The detailed design and fabrication of the instrument was performed during the period of June 1989 to July 1990. The software development effort and instrument integration/test extended from July 1990 to February 1991. Software development included an operator interface/menu structure, instrument internal control functions, DSP image processing code, and a display algorithm coding program. The instrument was delivered to NASA in March 1991. Potential commercial and research uses for this instrument are in its primary application as a field geologists exploration tool. Other applications have been suggested but not investigated in depth. These are measurements of process control in commercial materials processing and quality control functions which require information on surface heterogeneity.

Osterwisch, Frederick G.↗

Calibration of EcoBadge Test-Strips for Ozone Measurement for GLOBE

The majority of our work, therefore, centered on experiments at an extended exposure period at low ozone concentrations, creating and programming the necessary calibration curve into a Zikua reader. and verifying that the Zikua would use the curve reliably. Zikua is a device supplied by Vistanomics to 'read' the exposed EcoBadge cards and provide a read-out of measured ozone concentration in ppb. This device replaces the visual comparison to a calibrated color chart. For our initial studies, test papers were prepared by the usual method in small batches. Although testing would also eventually include Vistanomics' EcoBadge papers, we began with papers prepared in our lab so that we could be assured of the freshness of each batch. We felt this would allow us better comparison among our runs as we varied exposure time. At the outset, our target acceptable error was about +/- 10%. For example, if the actual ozone concentration was 20 ppb, then we hoped to be in the range 18-22 ppb. If the actual ozone concentration was 100 ppb. then we hoped to fall within 90-110 ppb in our measurements. Clearly a systematic error in the range of 3-4 ppb or more would significantly affect the lower exposure data.

Bush, Linda C.↗

Multiloop Rapid-Rise/Rapid Fall High-Voltage Power Supply

A proposed multiloop power supply would generate a potential as high as 1.25 kV with rise and fall times <100 s. This power supply would, moreover, be programmable to generate output potentials from 20 to 1,250 V and would be capable of supplying a current of at least 300 A at 1,250 V. This power supply is intended to be a means of electronic shuttering of a microchannel plate that would be used to intensify the output of a charge-coupled-device imager to obtain exposure times as short as 1 ms. The basic design of this power supply could also be adapted to other applications in which high voltages and high slew rates are needed. At the time of reporting the information for this article, there was no commercially available power supply capable of satisfying the stated combination of voltage, rise-time, and fall-time requirements. The power supply would include a preregulator that would be used to program a voltage 1/30 of the desired output voltage. By means of a circuit that would include a pulse-width modulator (PWM), two voltage doublers, and a transformer having two primary and two secondary windings, the preregulator output voltage would be amplified by a factor of 30. A resistor would limit the current by controlling a drive voltage applied to field-effect transistors (FETs) during turn-on of the PWM. Two feedback loops would be used to regulate the high output voltage. A pulse transformer would be used to turn on four FETs to short-circuit output capacitors when the outputs of the PWM were disabled. Application of a 0-to-5-V square to a PWM shut-down pin would cause a 20-to-1,250-V square wave to appear at the output.

Bearden, Douglas↗

Evaluation of Low-Pressure Cold Plasma for Disinfection for ISS Grown Produce and Metallic Instrumentation

Cold plasma (CP) cleaning is a dry, non-thermal process, which can provide broad-spectrum antimicrobial activity yet reportedly causes little to no damage to the object being sanitized. Since cold plasma uses no liquids, it has the distinct advantage when used in microgravity of not having to separate liquids from the item being cleaned. This paper will present results on an effort to use low pressure CP to disinfect or sterilize materials for in space applications. Exposure times from 0 to 60 minutes and pressures ranging from 10 to 100 Pa were used to optimize plasma parameters to achieve acceptable kill rates for 3 bacteria, Bacillus cereus, E. coli and Bacillus pumulis SAFR-32 and one fungi, Aspergillus niger. These tests were done on produce and metal coupons to simulate medical equipment. Produce testing was not successful, with unacceptable kill rates and the produce being negatively impacted by exposure to the plasma. The plasma caused a 5 log reduction in the number of viable bacteria on metal coupon tests, which placed the number of viable bacteria below the detection limit. This is a very promising result showing that sterilization of medical equipment with cold plasma is feasible. Scanning Electron Microscope images were taken before and after exposure. The images after plasma exposure shows that the bacteria spores have been physically affected, as their size has gotten smaller and the appearance has changed.

Hintze, Paul E.↗

Negative linear compressibility in Se at ultra-high pressure above 120 GPa

A series of in situ synchrotron X-ray diffraction (XRD) measurements were carried out, combined with first-principles calculations, to study structural phase transitions of selenium at high pressures and room temperature. Several phase transitions were observed, among which an isostructural phase transition was found at around 120 GPa for the first time. Evolved from the rhombohedral (space group R$\bar{3}$m) structure (Se-V), the new phase (Se-V') exhibited an interesting increase of lattice parameter a at pressures from 120 to 148 GPa, known as negative linear compressibility (NLC). The discovery of NLC behavior observed in this work is mainly attributed to the accuracy and fine steps controlled by the membrane system for in situ XRD data collected with an exposure time of 0.5 s. After 140 GPa, a body-centered cubic (b.c.c.) structure Se-VI (space group Im$\bar{3}$m) was formed, which remains stable up to 210 GPa, the highest pressure achieved in this study. The bulk moduli of phases Se-V, Se-V' and Se-VI were estimated to be 83 ± 2, 321 ± 2 and 266 ± 7 GPa, respectively, according to the P–V curve fit by the third-order Birch–Murnaghan equation of state. The Se-V' phase shows a bulk modulus almost 4 times larger than that of the Se-V phase, which is mainly due to the effect of its NLC. NLC in a higher pressure range is always more significant in terms of fundamental mechanism and new materials discovery, yet it has barely been reported at pressures above 100 GPa. This will hopefully inspire future studies on potential NLC behaviors in other materials at ultra-high pressure.

36 MATERIALS SCIENCE↗

Chandra Observations of the Young Cluster NGC 2516

The Chandra observatory was Launched July 23 1999. The first two months of the mission have been spent performing on-orbit calibration. This phase of the mission has included about 60 Ks of observing time on the young cluster NGC 2516. The observations have been made as part of the measurements of the boresight and the plate-scale of the various instruments. These observations will augment planned (deeper) GTO observation of this cluster. Here we present the results of these early observations. As of September 7, in a single ACIS 5'x5' field (one backside chip) examined 26 sources were detected in a single 10 Ks exposure. This represents less than one sixth of the total exposure time and less than one sixth of the total area to be observed during the calibration phase. we will compare the characteristics of those sources detected with Chandra with those detected by ROSAT. Since these observations are being made using all detectors, we will also compare observations among the various detectors.

Wolk, Scott J.↗

Neutron and high speed photogrammetric arcjet diagnosis

Two methods for real time internal diagnostics of arcjet engines are described. One method uses cold, thermal, or epithermal neutrons. Cold neutrons are used to detect the presence and location of hydrogenous propellants. Thermal neutrons are used to delineate the edge contours of anode and cathode surfaces and to measure stress/strain. Epithermal neutrons are used to measure temperatures on arcjet surfaces, bulk material temperatures, and point temperatures in bulk materials. It is found that this method, with an exposure time of 10 min, produces at temperature accuracy for W or Re of + or - 2.5 C. The other method uses visible-light high-speed photogrammetry to obtain images of the transient behavior of the arc during start-up and to relate this behavior to electrial supply characteristics such as voltage, current, and ripple.

Stewart, P. A. E.↗

X-ray Photoelectron Spectroscopy Study of Argon-Plasma-Treated Fluoropolymers

Films of poly(tetrafluoroethylene) (PTFE) and of a tetrafluoroethylene-perfluoroalkyl vinyl ether (approximately 49:1) copolymer (PFA) were exposed to a radio-frequency argon plasma and then examined by X-ray photoelectron spectroscopy (XPS). The use of fluoropolymer films nearly free of surface hydrocarbon contamination as well as the use of a monochromatized X-ray source for XPS removed two factors contributing to conflicting reports on the effect of exposure time on the fluorine-to-carbon (F/C) and oxygen-to-carbon (O/C) ratios for several Ar-plasma-treated fluoropolymers. Contrary to literature indications, a common pattern was found for PTFE and PFA: a moderate decrease in F/C ratio (from 1.99 to 1.40, and from 1.97 to 1.57, respectively), together with a moderate increase in O/C ratio (from negligible to about 0.10, and from 0.012 to about O.10, respectively) at very short exposures, after which the F/C ratios remained essentially constant on prolonged exposures, while the O/C ratios for PTFE and PFA leveled off at 0.11 and 0.15, respectively. The XPS C(sub 1s), spectra for these polymers exposed to the Ar plasma for 20 min were similar and presented, besides a prominent peak at 292.0 eV (CF2,) and a minor peak at 294.0 or 294.1 eV (CF3), a composite band of four curve-resolved peaks (approximately 285-290 eV) representing various CH, CC, CO, CN, and CF functionalities.

Golub, Morton A.↗

Patterns of Trace Element Accumulation in Waterfowl Restricted to Impoundments Holding Coal Combustion Waste

Waterfowl are often exposed to and readily accumulate anthropogenic contaminants when foraging in polluted environments. Settling impoundments containing coal combustion waste (CCW) enriched in trace elements such as arsenic (As), selenium (Se), and mercury (Hg) are often used by free-ranging migratory and resident waterfowl and represent potential sources for contaminant uptake. To assess accumulation of CCW contaminants, we experimentally restricted waterfowl to a CCW-contaminated impoundment and quantified trace element burdens in blood, muscle, and liver tissues over known periods of exposure (between 3 and 92 d). From these data we developed models 1) to predict elemental bioaccumulation with increased exposure time, and 2) to predict muscle/liver burdens based on concentrations in blood as a nondestructive sampling method. Although Hg and As did not bioaccumulate in our waterfowl, we observed an increase in Se concentrations in muscle, liver, and blood tissues over the duration of our experiment. Furthermore, we found that blood may be used as an effective nondestructive sampling alternative to predict muscle and liver tissue concentrations in birds contaminated with Se and As through dietary exposure. These data provide unique insights into accumulation rates of contaminants for waterfowl utilizing habitats contaminated with CCW and demonstrate the efficacy of nonlethal sampling of waterfowl to quantify contaminant exposure. Environ Toxicol Chem 2020;39:1052–1059.

54 ENVIRONMENTAL SCIENCES↗

An evaluation of candidate oxidation resistant materials

Ground based testing of materials considered for Kapton solar array blanket protection, graphite epoxy structural member protection, and high temperature radiators was performed in an RF plasma asher. Ashing rates for Kapton were correlated with rates measured on STS-8 to determine the exposure time equivalent to one year in low Earth orbit (LEO) at a constant density space station orbital flux. Protective coatings on Kapton from Tekmat, Andus Corporation, and LeRC were evaluated in the plasma asher and mass loss rates per unit area were measured for each sample. All samples evaluated provided some protection to the underlying surface but ion beam sputter deposited samples of SiO2 and SiO2 with 8% polytetrafluoroethylene (PTFE) showed no evidence of degradation after 47 hours of exposure. Mica paint was evaluated as a protective coating for graphite epoxy structural members. Mica appears to be resistant to attack by atomic oxygen but only offers some limited protection as a paint because the paint vehicles evaluated to date were not resistant to atomic oxygen. Four materials were selected for evaluation as candidate radiator materials: stainless steel, copper, niobium-1% zirconium, and titanium-6% aluminum-4% vanadium. These materials were surface textured by various means to improve their emittance. Emittances as high as 0.93 at 2.5 microns for stainless steel and 0.89 at 2.5 microns for Nb-1 Zr were obtained from surface texturing. There were no significant changes in emittance after asher exposure.

Rutledge, Sharon↗

The hyperplane of early-type galaxies: using stellar population properties to increase the precision and accuracy of the fundamental plane as a distance indicator

ABSTRACT We use deep spectroscopy from the SAMI (Sydney-AAO Multi-object Integral) Galaxy Survey to explore the precision of the fundamental plane (FP) of early-type galaxies as a distance indicator for future single-fibre spectroscopy surveys. We study the optimal trade-off between sample size and signal-to-noise ratio (SNR), and investigate which additional observables can be used to construct hyperplanes with smaller intrinsic scatter than the FP. We add increasing levels of random noise (parametrized as effective exposure time) to the SAMI spectra to study the effect of increasing measurement uncertainties on the FP- and hyperplane-inferred distances. We find that, using direct-fit methods, the values of the FP and hyperplane best-fitting coefficients depend on the spectral SNR, and reach asymptotic values for a mean $\langle \mathrm{ SNR} \rangle =40\, \mathrm{\mathring{\rm A}}^{-1}$. As additional variables for the FP we consider three stellar-population observables: light-weighted age, stellar mass-to-light ratio, and a novel combination of Lick indices ($I_\mathrm{age}$). For an $\langle \mathrm{ SNR} \rangle =45~\mathrm{\mathring{\rm A}}^{-1}$ (equivalent to 1-h exposure on a 4-m telescope), all three hyperplanes outperform the FP as distance indicators. Being an empirical spectral index, $I_\mathrm{age}$ avoids the model-dependent uncertainties and bias underlying age and mass-to-light ratio measurements, yet yields a 10 per cent reduction of the median distance uncertainty compared to the FP. We also find that, as a by-product, the $I_\mathrm{age}$ hyperplane removes most of the reported environment bias of the FP. After accounting for the different SNR, these conclusions also apply to a 50 times larger sample from SDSS-III (Sloan Digital Sky Survey). However, in this case, only $\mathrm{ age}$ removes the environment bias.

D’Eugenio, Francesco (ORCID:0000000323888172)↗

Continuous polymer films deposited on top of porous substrates using plasma-enhanced atomic layer deposition and molecular layer deposition

Molecular layer deposition (MLD) is able to produce ultrathin polymer films with control over thickness, cross-linking, and chemical composition. With these capabilities, MLD should be useful in the fabrication of novel polymer membranes on porous supports. However, confining a continuous MLD film to the surface of porous substrates is difficult because of MLD film growth in the pores. The deposition in the pores lowers the conductance of the porous support. This paper presents a method to deposit continuous polymer films on top of porous substrates. In this method, Al2O3 plasma-enhanced atomic layer deposition (PE-ALD) using trimethylaluminum and oxygen plasma as the reactants was first used to cap the pores of the substrate. Subsequently, a polyamide MLD film was deposited on the Al2O3 PE-ALD capping layer using m-phenylenediamine and trimesoyl chloride as the reactants. The Al2O3 pore caps were then removed from the porous substrate by etching from the backside using a timed exposure to a dilute sodium hydroxide solution. This method was demonstrated using anodic aluminum oxide (AAO) and polyethersulfone (PES) porous substrates. Al2O3 PE-ALD film growth was limited to the top of the porous substrate, resulting in rapid surface recombination or high sticking coefficients for the reactive plasma species within the pores. Gas permeance measurements confirmed the pore capping of the AAO substrates. The reopening of the pores by dissolving the Al2O3 pore caps with a sodium hydroxide solution was monitored using gas permeance versus etch time. The removal of the Al2O3 pore caps from the PES substrates could also dissolve the Al2O3 layer underneath the MLD film. The loss of this Al2O3 layer led to the detachment of the MLD film from the PES substrate. However, the MLD film could be anchored to the PES support at fractures located in the Al2O3 film prior to the MLD. The Al2O3 film fracture allowed the MLD film to anchor firmly to the PES substrate by MLD in the pores of the PES porous substrate. The distance between the anchor points was a function of fracture density. This distance could be controlled by applying a tensile stress to the Al2O3 PE-ALD film to fracture the film through sample bending. This method produced firmly anchored polymer MLD films on top of the PES porous substrates.

Welch, Brian C. (ORCID:000000029747045X)↗

TEM Analyses of Itokawa Regolith Grains and Lunar Soil Grains to Directly Determine Space Weathering Rates on Airless Bodies

Samples returned from the moon and Asteroid Itokawa by NASA's Apollo Missions and JAXA's Hayabusa Mission, respectively, provide a unique record of their interaction with the space environment. Space weathering effects result from micrometeorite impact activity and interactions with the solar wind. While the effects of solar wind interactions, ion implantation and solar flare particle track accumulation, have been studied extensively, the rate at which these effects accumulate in samples on airless bodies has not been conclusively determined. Results of numerical modeling and experimental simulations do not converge with observations from natural samples. We measured track densities and rim thicknesses of three olivine grains from Itokawa and multiple olivine and anorthite grains from lunar soils of varying exposure ages. Samples were prepared for analysis using a Leica EM UC6 ultramicrotome and an FEI Quanta 3D dual beam focused ion beam scanning electron microscope (FIB-SEM). Transmission electron microscope (TEM) analyses were performed on the JEOL 2500SE 200kV field emission STEM. The solar wind damaged rims on lunar anorthite grains are amorphous, lack inclusions, and are compositionally similar to the host grain. The rim width increases as a smooth function of exposure age until it levels off at approximately 180 nm after approximately 20 My (Fig. 1). While solar wind ion damage can only accumulate while the grain is in a direct line of sight to the Sun, solar flare particles can penetrate to mm-depths. To assess whether the track density accurately predicts surface exposure, we measured the rim width and track density in olivine and anorthite from the surface of rock 64455, which was never buried and has a surface exposure age of 2 My based on isotopic measurements. The rim width from 64455 (60-70nm) plots within error of the well-defined trend for solar wind amorphized rims in Fig. 1. Measured solar flare track densities are accurately reflecting the surface exposure of the grains. Track densities correlate with the amorphous rim thicknesses. While the space-weathered rims of anorthite grains are amorphous, the space-weathered rims on both Itokawa and lunar olivine grains show solar wind damaged rims that are not amorphous. Instead, the rims are nanocrystalline with high dislocation densities and sparse inclusions of nanophase Fe metal. The rim thicknesses on the olivine grains also correlate with track density. The Itokawa olivine grains have track densities that indicate surface exposures of approximately 10(exp 5) years. Longer exposures (up to approximately 10(exp 7) years) do not amorphize the rims, as evidenced by lunar soil olivines with high track densities (approximately 10(exp 11) cm(exp -2)). From the combined data, shown in Fig. 1, it is clear that olivine is damaged (but not amorphized) more rapidly by the solar wind compared to anorthite. The olivine damaged rim forms quickly (in approximately 10(exp 6) y) and saturates at approximately 120nm with longer exposure time. The anorthite damaged rims form more slowly, amorphize, and grow thicker than the olivine rims. This is in agreement with numerical modeling data which predicts that solar wind damaged rims on anorthite will be thicker than olivine. However, the models predict that both olivine and anorthite rims will amorphize and reach equilibrium widths in less than 10(exp 3) y, in contrast to what is observed for natural samples. Laboratory irradiation experiments, which show rapid formation of fully amorphous and blistered surfaces from simulated solar wind exposures are also in contrast to observations of natural samples. These results suggest that there is a flux dependence on the type and extent of irradiation damage that develops in olivine. This flux dependence suggests that great caution be used in extrapolating between high-flux laboratory experiments and the natural case, as demonstrated by. We constrain the space weathering rate through analysis of returned samples. Provided that the track densities and the solar wind damaged rim widths exhibited by the Itokawa grains are typical of the fine-grained regions of Itokawa, then the space weathering rate is on the order of 10(exp 5) y. Space weathering effects in lunar soils saturate within a few My of exposure while those in Itokawa regolith grains formed in approximately 10(exp 5) y. Olivine and anorthite respond differently to solar wind irradiation. The space weathering effects in olivine are particularly difficult to reconcile with laboratory irradiation studies and numerical models. Additional measurements, experiments, and modeling are required to resolve the discrepancies among the observations and calculations involving solar wind amorphization of different minerals on airless bodies.

Berger, Eve L.↗

Antibody dynamics to SARS‐CoV‐2 in asymptomatic COVID‐19 infections

Abstract Background The missing asymptomatic COVID‐19 infections have been overlooked because of the imperfect sensitivity of the nucleic acid testing (NAT). Globally understanding the humoral immunity in asymptomatic carriers will provide scientific knowledge for developing serological tests, improving early identification, and implementing more rational control strategies against the pandemic. Measure Utilizing both NAT and commercial kits for serum IgM and IgG antibodies, we extensively screened 11 766 epidemiologically suspected individuals on enrollment and 63 asymptomatic individuals were detected and recruited. Sixty‐three healthy individuals and 51 mild patients without any preexisting conditions were set as controls. Serum IgM and IgG profiles were further probed using a SARS‐CoV‐2 proteome microarray, and neutralizing antibody was detected by a pseudotyped virus neutralization assay system. The dynamics of antibodies were analyzed with exposure time or symptoms onset. Results A combination test of NAT and serological testing for IgM antibody discovered 55.5% of the total of 63 asymptomatic infections, which significantly raises the detection sensitivity when compared with the NAT alone (19%). Serum proteome microarray analysis demonstrated that asymptomatics mainly produced IgM and IgG antibodies against S1 and N proteins out of 20 proteins of SARS‐CoV‐2. Different from strong and persistent N‐specific antibodies, S1‐specific IgM responses, which evolved in asymptomatic individuals as early as the seventh day after exposure, peaked on days from 17 days to 25 days, and then disappeared in two months, might be used as an early diagnostic biomarker. 11.8% (6/51) mild patients and 38.1% (24/63) asymptomatic individuals did not produce neutralizing antibody. In particular, neutralizing antibody in asymptomatics gradually vanished in two months. Conclusion Our findings might have important implications for the definition of asymptomatic COVID‐19 infections, diagnosis, serological survey, public health, and immunization strategies.

Lei, Qing↗