Design and Evaluation of Artificial Hybrid Photoredox Biocatalysts
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Downhole monitoring plays a crucial part in a geological carbon dioxide (CO 2 ) sequestration project, especially in providing early warnings of failure. However, most downhole monitoring technologies are often low in spatial resolution and time-consuming, or expensive and have system longevity issues. To address this issue, a robust and cost-effective distributed coaxial cable Fabry-Perot interferometer-based temperature sensor is proposed for real-time downhole monitoring. The coaxial cable sensor (CCS) was made in house and tested using a high pressure high temperature (HPHT) testing apparatus to study the sensor accuracy, sensitivity, stability, and crosstalk effect in simulated downhole conditions. The laboratory test results indicate that the sensor can work under simulated downhole conditions of pressures up to 1000 psia and temperatures up to 110°C. At 1 ATM, the sensor has an accuracy of about 1%. At 1000 psia, the hysteresis phenomenon is observed, but it is reduced and tends to stabilize after repeated heating and cooling treatments. The pressure crosstalk effect was observed on the flexible cable sensor and minimized on the rigid cable sensor. The temperature and pressure range of the distributed CCS allows long-term in situ monitoring for a well depth up to 2500 feet, which would prove of great value in detecting temperature change associated with wellbore leakage that may lead to groundwater contamination.
Improved scientific and engineering understanding of the behavior of geologic CO2 storage together with established regulatory framework and incentive structures raise the prospects for accelerated, large-scale deployment of this greenhouse gas emissions reduction approach. Incentive structures call for the establishment of appropriate verification and accounting approaches to support claims of the integrity of a geologic storage complex and to justify taking credit for long-term storage. In this study, we present a framework for assessing the probability of containment effectiveness over the lifetime of a geologic carbon storage site (e.g., after 70 years of injection and post-injection site performance) using forward stochastic model realizations based on site characterization data and using a monitoring-informed Bayesian network based on hypothetical detectability from surface seismic surveys over the site injection and post-injection phases. The National Risk Assessment Partnership’s open-source Integrated Assessment Model (NRAP-Open-IAM) was utilized to develop an ensemble of 10,000 a priori stochastic forecasts of CO2 containment. Those simulations were used to train the Bayesian network model to estimate the prior probabilities of the CO2 leakage mass into overlying, monitorable aquifers considering the uncertainties in the reservoir properties, permeability of potentially leaky wells and the overlying aquifers. The conditional probabilities in the Bayesian network were either learned from the NRAP-Open-IAM simulations or derived from the predefined detection thresholds for the monitoring method. Observations obtained from monitoring, over time during the site operation phases were then used to generate updated posterior probabilities of containment (and any loss from containment) in the Bayesian network by propagating the prior probabilities through the conditional probabilities. We demonstrate how to construct and use the Bayesian network for verifying the long-term storage complex effectiveness informed by monitoring based on the NRAP-Open-IAM simulations previously developed for the FutureGen 2.0 site. This approach may have relevance for stake holders to demonstrate secure geologic storage, provide a defensible, probabilistic approach to claim credit for geologic storage, and to estimate the likelihood that any fraction of the claimed credit may need to be refunded to the creditor based on available monitoring information.
Abstract Polymeric membranes have shown tremendous promise for the separation of CO 2 from flue gas streams. However, few systematic studies have been conducted to better understand the impact that chemical functionalities have on membrane‐based gas separation performance. To address this gap, we herein describe the synthesis and gas separation performance of a series of vinyl‐addition polynorbornenes bearing various CO 2 ‐philic functional groups. To facilitate direct comparison between functional groups, each material was designed to maintain a common polymer backbone. Though the incorporation of CO 2 ‐philic moieties within a dense polymeric membrane is frequently hypothesized to enhance CO 2 solubility, and thereby increase CO 2 /N 2 selectivity, our results demonstrate that the incorporation of CO 2 ‐philic groups onto a common polymer backbone do not necessarily result in increased gas separation performance. Experimental and computational results demonstrate that the incorporation of amidoxime groups onto a polynorbornene backbone increase CO 2 /N 2 selectivity, whereas commonly employed ethereal side chains only increased permeability.
Explore the source record for details and available documents.
The origins of open-circuit voltage deficits in Cu2ZnSnS(e)4-based solar cells have been an intense topic of research over the past few years as device efficiencies have never approached those of CuInGaSe2 based cells despite the materials sharing similar crystal and electronic structures. In this work, we use transmission X-ray microscopy tomography to investigate the length scales over which elemental fluctuations occur. We find and show evidence of micron-scale Cu to Zn anti-correlations over a previously inaccessible combination of resolution and sample size that is consistent with the length scale of grains in this material. This result yields further insight into the causes of the large open-circuit voltage deficits regularly seen in these devices as well as the challenges of achieving compositional homogeneity in this material.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
Abstract Not Provided
Explore the source record for details and available documents.
Suspension plasma spray (SPS) is far more complicated than conventional plasma spray and requires a deep knowledge about the influence of process parameters and their correlations. In this study, YSZ coatings were manufactured by SPS with six different process parameters such as plasma power, suspension mass load, original powder size, substrate surface topology, spray distance, and spray step. Then, the porosity of as-prepared coatings was investigated by image method and X-ray transmission technique. A multivariate analysis on the collected experimental data was carried out by employing mathematical statistics methods. The results showed that: 1) Coating porosity has a negative correlation with plasma power and suspension mass load and a positive correlation with the original powder size, spray distance, spray step, and substrate roughness; 2) Spraying distance is the main factor affecting to coating porosity, followed by suspension mass load and substrate surface roughness, respectively. A linear model for porosity prediction was developed and was verified by experiments. Furthermore, the mechanism by which process parameters influence coating porosity is additionally discussed.