Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Model-based Dynamic Control of Speculative Forays in Parallel Computation

In simulations running in parallel, the processors would have to synchronize with other processors to maintain correct global order of computations. This can be done either by blocking computation until correct order is guaranteed, or by \textit{speculatively} proceeding with the best guess (based on local information) and later correcting errors if/as necessary. Since the gainful lengths of speculative forays depend on the dynamics of the application software and hardware at runtime, an online control system is necessary to dynamically choose and/or switch between the blocking and speculative strategies. In this paper, we formulate the reversible speculative computing in large-scale parallel computing as a dynamic linear feedback control (optimization) system model and evaluate its performance in terms of time and cost savings as compared to the traditional (forward) computing. We illustrate with an exact analogy in the form of vehicular travel under dynamic, delayed route information. The objective is to assist in making the optimal decision on what computational approach is to be chosen, by predicting the amount of time and cost savings (or losing) under different environments represented by different parameters and probability distribution functions. We consider the cases of Gaussian, exponential and log-normal distribution functions. The control system is intended for incorporating into speculative parallel applications such as optimistic parallel discrete event simulations to decide at runtime when and to what extent speculative execution can be performed gainfully.

Perumalla, Kalyan↗

Deep learning interfacial momentum closures in coarse-mesh CFD two-phase flow simulation using validation data

Multiphase flow phenomena have been widely observed in the industrial applications while it remains a challenging yet unsolved problems. Three-dimensional computational fluid dynamics (CFD) approaches resolve the flow fields on a finer special and temporal scales which can complement the dedicated experimental study. However, closures have to be introduced to reflect the underlying physics in multiphase flow. Among them, the interfacial forces, including drag, lift, turbulent dispersion and wall lubrication forces, play in important role on the bubble’s distribution and migration in liquid-vapor two-phase flow. Development of those closures traditionally rely on the experimental data and analytical derivation with simplified assumptions which usually cannot deliver a universal solution across wide range of flow conditions. In this paper, a data-driven approach, named as Feature Similarity Measurement (FSM), is developed and applied to improve the simulation capability of two-phase flow with coarse-mesh CFD approach. Interfacial momentum transfer in adiabatic bubbly flow serves as the focus of the present study. Both a mature and a simplified set of interfacial closures are taken as the low fidelity data. Experimental data and fine mesh CFD simulations results are adopted as high-fidelity data. Qualitative and quantitative analysis are performed in this paper which reveals that FSM can substantially improve the prediction of coarse mesh CFD model regardless of the choice of interfacial closures and it provides scalability and consistency across discontinuous flow regimes. Furthermore, it demonstrates that data-driven method can aid the multiphase flow modeling by exploring the connections between local physical features and simulation errors.

97 MATHEMATICS AND COMPUTING↗

An experimental comparison of various methods of nearfield acoustic holography

An experimental comparison of four different methods of nearfield acoustic holography (NAH) is presented in this study for planar acoustic sources. The four NAH methods considered in this study are based on: (1) spatial Fourier transform, (2) equivalent sources model, (3) boundary element methods and (4) statistically optimized NAH. Two dimensional measurements were obtained at different distances in front of a tonal sound source and the NAH methods were used to reconstruct the sound field at the source surface. Reconstructed particle velocity and acoustic pressure fields presented in this study showed that the equivalent sources model based algorithm along with Tikhonov regularization provided the best localization of the sources. Reconstruction errors were found to be smaller for the equivalent sources model based algorithm and the statistically optimized NAH algorithm. Effect of hologram distance on the performance of various algorithms is discussed in detail. The study also compares the computational time required by each algorithm to complete the comparison. Four different regularization parameter choice methods were compared. The L-curve method provided more accurate reconstructions than the generalized cross validation and the Morozov discrepancy principle. Finally, the performance of fixed parameter regularization was comparable to that of the L-curve method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-energy differential-filtering photon spectrometer for ultraintense laser-matter interactions

Large quantities of ultrahigh-energy x-rays are produced by petawatt-class lasers; however, spectroscopy in this range of 0.1-1 MeV is difficult due to the long photon mean free path. A novel geometry step filter to measure the high-energy bremsstrahlung emission tail has been developed for use in high energy density, short-pulse laser-matter interaction experiments. The grid design of the filters allows for the independent determination of a local background, which reduces systematic errors in the reconstructed spectra. This spectrometer was used to measure x-ray spectra for various laser and target conditions at intensities near 1 × 10 18 W/cm 2 where single-exponential bremsstrahlung spectra were fit to the data and show an increasing photon temperature with pulse duration for a fixed laser intensity.

47 OTHER INSTRUMENTATION↗

THE ARECIBO LEGACY FAST ALFA SURVEY: THE {alpha}.40 H I SOURCE CATALOG, ITS CHARACTERISTICS AND THEIR IMPACT ON THE DERIVATION OF THE H I MASS FUNCTION

We present a current catalog of 21 cm H I line sources extracted from the Arecibo Legacy Fast Arecibo L-band Feed Array (ALFALFA) survey over {approx}2800 deg{sup 2} of sky: the {alpha}.40 catalog. Covering 40% of the final survey area, the {alpha}.40 catalog contains 15,855 sources in the regions 07{sup h}30{sup m} < R.A. < 16{sup h}30{sup m}, +04 Degree-Sign < decl. <+16 Degree-Sign , and +24 Degree-Sign < decl. <+28 Degree-Sign and 22{sup h} < R.A. < 03{sup h}, +14 Degree-Sign < decl. <+16 Degree-Sign , and +24 Degree-Sign < decl. < + 32 Degree-Sign . Of those, 15,041 are certainly extragalactic, yielding a source density of 5.3 galaxies per deg{sup 2}, a factor of 29 improvement over the catalog extracted from the H I Parkes All-Sky Survey. In addition to the source centroid positions, H I line flux densities, recessional velocities, and line widths, the catalog includes the coordinates of the most probable optical counterpart of each H I line detection, and a separate compilation provides a cross-match to identifications given in the photometric and spectroscopic catalogs associated with the Sloan Digital Sky Survey Data Release 7. Fewer than 2% of the extragalactic H I line sources cannot be identified with a feasible optical counterpart; some of those may be rare OH megamasers at 0.16 < z < 0.25. A detailed analysis is presented of the completeness, width-dependent sensitivity function and bias inherent of the {alpha}.40 catalog. The impact of survey selection, distance errors, current volume coverage, and local large-scale structure on the derivation of the H I mass function is assessed. While {alpha}.40 does not yet provide a completely representative sampling of cosmological volume, derivations of the H I mass function using future data releases from ALFALFA will further improve both statistical and systematic uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

BRIGHT SOURCE SUBTRACTION REQUIREMENTS FOR REDSHIFTED 21 cm MEASUREMENTS

The H I 21 cm transition line is expected to be an important probe into the cosmic dark ages and epoch of reionization. Foreground source removal is one of the principal challenges for the detection of this signal. This paper investigates the extragalactic point source contamination and how accurately bright sources ({approx}>1 Jy) must be removed in order to detect 21 cm emission with upcoming radio telescopes such as the Murchison Widefield Array. We consider the residual contamination in 21 cm maps and power spectra due to position errors in the sky model for bright sources, as well as frequency-independent calibration errors. We find that a source position accuracy of 0.1 arcsec will suffice for detection of the H I power spectrum. For calibration errors, 0.05% accuracy in antenna gain amplitude is required in order to detect the cosmic signal. Both sources of subtraction error produce residuals that are localized to small angular scales, k{sub perpendicular} {approx}> 0.05 Mpc{sup -1}, in the two-dimensional power spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

Benchmarking machine learning strategies for phase-field problems

Abstract We present a comprehensive benchmarking framework for evaluating machine-learning approaches applied to phase-field problems. This framework focuses on four key analysis areas crucial for assessing the performance of such approaches in a systematic and structured way. Firstly, interpolation tasks are examined to identify trends in prediction accuracy and accumulation of error over simulation time. Secondly, extrapolation tasks are also evaluated according to the same metrics. Thirdly, the relationship between model performance and data requirements is investigated to understand the impact on predictions and robustness of these approaches. Finally, systematic errors are analyzed to identify specific events or inadvertent rare events triggering high errors. Quantitative metrics evaluating the local and global description of the microstructure evolution, along with other scalar metrics representative of phase-field problems, are used across these four analysis areas. This benchmarking framework provides a path to evaluate the effectiveness and limitations of machine-learning strategies applied to phase-field problems, ultimately facilitating their practical application.

36 MATERIALS SCIENCE↗

Optimal limits on f{sub NL}{sup local} from WMAP 5-year data

We have applied the optimal estimator for f{sub NL}{sup local} to the 5 year WMAP data. Marginalizing over the amplitude of foreground templates we get −4 < f{sub NL}{sup local} < 80 at 95% CL. Error bars of previous (sub-optimal) analyses are roughly 40% larger than these. The probability that a Gaussian simulation, analyzed using our estimator, gives a result larger in magnitude than the one we find is 7 %. Our pipeline gives consistent results when applied to the three and five year WMAP data releases and agrees well with the results from our own sub-optimal pipeline. We find no evidence of any residual foreground contamination.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling plasma toroidal flow profile control via NTV torque with n = 2 3D fields in MAST-U

Toroidal modeling utilizing the MARS-Q code shows that large (compared to electromagnetic torque) neoclassical toroidal viscous (NTV) torque can be achieved in the plasma core region in reference MAST(-U) L-mode plasmas, by applying the n=2 (n is the toroidal mode number) 3-D fields generated by the magnetic coils used for controlling the edge localized mode and/or by the error field correction coils. Large NTV torque, occurring at relatively slow plasma flow, in combination with strong variation of the torque amplitude versus the coil phasing of the 3-D coils, offers a tool to control the plasma toroidal rotation profile in spherical tokamaks. To effectively employ the toroidal NTV torque, the potentially fast initial flow needs to first be damped by 3-D fields. In conclusion, MARS-Q quasi-linear initial value simulations demonstrate that this is achievable in MAST-U, within the designed 3-D coil current capability for the device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sparse Bayesian mass mapping with uncertainties: local credible intervals

ABSTRACT Until recently, mass-mapping techniques for weak gravitational lensing convergence reconstruction have lacked a principled statistical framework upon which to quantify reconstruction uncertainties, without making strong assumptions of Gaussianity. In previous work, we presented a sparse hierarchical Bayesian formalism for convergence reconstruction that addresses this shortcoming. Here, we draw on the concept of local credible intervals (cf. Bayesian error bars) as an extension of the uncertainty quantification techniques previously detailed. These uncertainty quantification techniques are benchmarked against those recovered via Px-MALA – a state-of-the-art proximal Markov chain Monte Carlo (MCMC) algorithm. We find that, typically, our recovered uncertainties are everywhere conservative (never underestimate the uncertainty, yet the approximation error is bounded above), of similar magnitude and highly correlated with those recovered via Px-MALA. Moreover, we demonstrate an increase in computational efficiency of $\mathcal {O}(10^6)$ when using our sparse Bayesian approach over MCMC techniques. This computational saving is critical for the application of Bayesian uncertainty quantification to large-scale stage IV surveys such as LSST and Euclid.

Price, M. A.↗

Exact analytical solution of the linear structure growth rate in {Lambda}CDM cosmology and its cosmological applications

We derive the exact analytical solution of the linear structure growth rate in {Lambda}CDM cosmology with flat or curved geometry, under the Newtonian gauge. Unlike the well known solution under the Newtonian limit [D. J. Heath, Mon. Not. R. Astron. Soc. 179, 351 (1977)], our solution takes all general relativistic corrections into account and is hence valid at both the sub- and superhorizon scales. With this exact solution, we evaluate cosmological impacts induced by these relativistic corrections. (1) General relativistic corrections alter the density growth from z=100 to z=0 by 10% at k=0.01 h/Mpc and the impact becomes stronger toward larger scales. We caution the readers that the overdensity is not gauge invariant and the above statement is restrained to the Newtonian gauge. (2) Relativistic corrections introduce a k{sup -2} scale dependence in the density fluctuation. It mimics a primordial non-Gaussianity of the local type with f{sub NL}{sup local{approx}}1. This systematical error may become non-negligible for future all sky deep galaxy surveys. (3) Cosmological simulations with box size greater than 1 Gpc are also affected by these relativistic corrections. We provide a postprocessing recipe to correct for these effects. (4) These relativistic corrections affect the redshift distortion. However, at redshifts and scales relevant to redshift distortion measurements, such effect is negligible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

User-Driven Sampling Strategies in Image Exploitation

Visual analytics and interactive machine learning both try to leverage the complementary strengths of humans and machines to solve complex data exploitation tasks. These fields overlap most significantly when training is involved: the visualization or machine learning tool improves over time by exploiting observations of the human-computer interaction. This paper focuses on one aspect of the human-computer interaction that we call user-driven sampling strategies. Unlike relevance feedback and active learning sampling strategies, where the computer selects which data to label at each iteration, we investigate situations where the user selects which data is to be labeled at each iteration. User-driven sampling strategies can emerge in many visual analytics applications but they have not been fully developed in machine learning. We discovered that in user-driven sampling strategies suggest new theoretical and practical research questions for both visualization science and machine learning. In this paper we identify and quantify the potential benefits of these strategies in a practical image analysis application. We find user-driven sampling strategies can sometimes provide significant performance gains by steering tools towards local minima that have lower error than tools trained with all of the data. Furthermore, in preliminary experiments we find these performance gains are particularly pronounced when the user is experienced with the tool and application domain.

97 MATHEMATICS AND COMPUTING↗

SU-C-9A-01: Parameter Optimization in Adaptive Region-Growing for Tumor Segmentation in PET

Purpose: To design a reliable method to determine the optimal parameter in the adaptive region-growing (ARG) algorithm for tumor segmentation in PET. Methods: The ARG uses an adaptive similarity criterion m - fσ ≤ I-PET ≤ m + fσ, so that a neighboring voxel is appended to the region based on its similarity to the current region. When increasing the relaxing factor f (f ≥ 0), the resulting volumes monotonically increased with a sharp increase when the region just grew into the background. The optimal f that separates the tumor from the background is defined as the first point with the local maximum curvature on an Error function fitted to the f-volume curve. The ARG was tested on a tumor segmentation Benchmark that includes ten lung cancer patients with 3D pathologic tumor volume as ground truth. For comparison, the widely used 42% and 50% SUVmax thresholding, Otsu optimal thresholding, Active Contours (AC), Geodesic Active Contours (GAC), and Graph Cuts (GC) methods were tested. The dice similarity index (DSI), volume error (VE), and maximum axis length error (MALE) were calculated to evaluate the segmentation accuracy. Results: The ARG provided the highest accuracy among all tested methods. Specifically, the ARG has an average DSI, VE, and MALE of 0.71, 0.29, and 0.16, respectively, better than the absolute 42% thresholding (DSI=0.67, VE= 0.57, and MALE=0.23), the relative 42% thresholding (DSI=0.62, VE= 0.41, and MALE=0.23), the absolute 50% thresholding (DSI=0.62, VE=0.48, and MALE=0.21), the relative 50% thresholding (DSI=0.48, VE=0.54, and MALE=0.26), OTSU (DSI=0.44, VE=0.63, and MALE=0.30), AC (DSI=0.46, VE= 0.85, and MALE=0.47), GAC (DSI=0.40, VE= 0.85, and MALE=0.46) and GC (DSI=0.66, VE= 0.54, and MALE=0.21) methods. Conclusions: The results suggest that the proposed method reliably identified the optimal relaxing factor in ARG for tumor segmentation in PET. This work was supported in part by National Cancer Institute Grant R01 CA172638; The dataset is provided by AAPM TG211.

60 APPLIED LIFE SCIENCES↗

A Block-Structured Adaptive Mesh Framework to Solve Radiation Transfer Equation in Irregular Embedded Geometries

Radiation transport arises in various scientific, industrial, and medical fields, and understanding its effect in applications is needed to make accurate predictions, safety assessments and performance optimizations. Solving the Radiation Transport Equation (RTE) is challenging due to its integro-differential nature, which involves both differential and integral terms. The differential term describes the change in radiation intensity due to absorption and emission, while the integral term accounts for scattering. The accurate modeling of radiation is further complicated in many applications due to the complex, irregular geometries. Various methods exist for solving the RTE, including the zonal, Monte Carlo, spherical harmonics, discrete ordinates, and finite volume methods. Traditional mesh-based approaches, which rely on structured or unstructured meshes, struggle with irregular geometries due to: a) the difficulty of conforming structured grids to irregular domains, b) challenges in enforcing boundary conditions correctly, and c) the additional computational cost of unstructured mesh methods. This work presents a second-order accurate method for solving the RTE in irregular geometries. The radiation intensity is discretized using the finite-volume method in both spatial and angular directions on regular Cartesian grid blocks. Leveraging the block-structured adaptive mesh refinement (AMR) framework provided by AMReX, our method refines the grid locally to reduce spatial discretization error, ensuring a converged numerical solution while minimizing computational costs elsewhere. A two-stage deferred correction approach is employed: First, a first-order discretization on grid blocks is solved using an algebraic multigrid method in HYPRE. Second, a correction term is applied explicitly to achieve second-order accuracy. The correction term is calculated by approximating the radiation flux on cell faces using a Total Variation Diminishing (TVD) scheme. This approach ensures quick convergence of the multigrid method while preserving higher-order accuracy of the numerical solution. Irregular geometries are resolved as embedded boundaries (EB), resulting in both cut cells and regular cells. In cut cells, we modify the fluxes using face fractions and incorporate additional contributions from EB boundary conditions. To ensure higher-order convergence near the EB interface, the correction term is modified by interpolating the radiation intensity to fictitious ghost points. The implementation takes advantage of modern supercomputers by leveraging AMReX’sMPI/X parallelization strategy where X can be MPI or a GPU accelerator including CUDA, HIP and DPC++. We validate our solver using classical test cases, both with and without EB, demonstrating accuracy and efficiency. Additionally, we analyze the impact of adaptive mesh refinement on solution accuracy and computational cost, highlighting the advantages of our approach for high-resolution radiation transport simulations.

computational fluid dynamics (CFD)↗

Image-Guided Localization Accuracy of Stereoscopic Planar and Volumetric Imaging Methods for Stereotactic Radiation Surgery and Stereotactic Body Radiation Therapy: A Phantom Study

Purpose: To evaluate the positioning accuracies of two image-guided localization systems, ExacTrac and On-Board Imager (OBI), in a stereotactic treatment unit. Methods and Materials: An anthropomorphic pelvis phantom with eight internal metal markers (BBs) was used. The center of one BB was set as plan isocenter. The phantom was set up on a treatment table with various initial setup errors. Then, the errors were corrected using each of the investigated systems. The residual errors were measured with respect to the radiation isocenter using orthogonal portal images with field size 3 x 3 cm{sup 2}. The angular localization discrepancies of the two systems and the correction accuracy of the robotic couch were also studied. A pair of pre- and post-cone beam computed tomography (CBCT) images was acquired for each angular correction. Then, the correction errors were estimated by using the internal BBs through fiducial marker-based registrations. Results: The isocenter localization errors ({mu} {+-}{sigma}) in the left/right, posterior/anterior, and superior/inferior directions were, respectively, -0.2 {+-} 0.2 mm, -0.8 {+-} 0.2 mm, and -0.8 {+-} 0.4 mm for ExacTrac, and 0.5 {+-} 0.7 mm, 0.6 {+-} 0.5 mm, and 0.0 {+-} 0.5 mm for OBI CBCT. The registration angular discrepancy was 0.1 {+-} 0.2{sup o} between the two systems, and the maximum angle correction error of the robotic couch was 0.2{sup o} about all axes. Conclusion: Both the ExacTrac and the OBI CBCT systems showed approximately 1 mm isocenter localization accuracies. The angular discrepancy of two systems was minimal, and the robotic couch angle correction was accurate. These positioning uncertainties should be taken as a lower bound because the results were based on a rigid dosimetry phantom.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Localization Accuracy of the Clinical Target Volume During Image-Guided Radiotherapy of Lung Cancer

Purpose: To evaluate the position and shape of the originally defined clinical target volume (CTV) over the treatment course, and to assess the impact of gross tumor volume (GTV)-based online computed tomography (CT) guidance on CTV localization accuracy. Methods and Materials: Weekly breath-hold CT scans were acquired in 17 patients undergoing radiotherapy. Deformable registration was used to propagate the GTV and CTV from the first weekly CT image to all other weekly CT images. The on-treatment CT scans were registered rigidly to the planning CT scan based on the GTV location to simulate online guidance, and residual error in the CTV centroids and borders was calculated. Results: The mean GTV after 5 weeks relative to volume at the beginning of treatment was 77% {+-} 20%, whereas for the prescribed CTV, it was 92% {+-} 10%. The mean absolute residual error magnitude in the CTV centroid position after a GTV-based localization was 2.9 {+-} 3.0 mm, and it varied from 0.3 to 20.0 mm over all patients. Residual error of the CTV centroid was associated with GTV regression and anisotropy of regression during treatment (p = 0.02 and p = 0.03, respectively; Spearman rank correlation). A residual error in CTV border position greater than 2 mm was present in 77% of patients and 50% of fractions. Among these fractions, residual error of the CTV borders was 3.5 {+-} 1.6 mm (left-right), 3.1 {+-} 0.9 mm (anterior-posterior), and 6.4 {+-} 7.5 mm (superior-inferior). Conclusions: Online guidance based on the visible GTV produces substantial error in CTV localization, particularly for highly regressing tumors. The results of this study will be useful in designing margins for CTV localization or for developing new online CTV localization strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Provably accurate simulation of gauge theories and bosonic systems

Quantum many-body systems involving bosonic modes or gauge fields have infinite-dimensional local Hilbert spaces which must be truncated to perform simulations of real-time dynamics on classical or quantum computers. To analyze the truncation error, we develop methods for bounding the rate of growth of local quantum numbers such as the occupation number of a mode at a lattice site, or the electric field at a lattice link. Our approach applies to various models of bosons interacting with spins or fermions, and also to both abelian and non-abelian gauge theories. We show that if states in these models are truncated by imposing an upper limit &#x039B; on each local quantum number, and if the initial state has low local quantum numbers, then an error at most &#x03F5; can be achieved by choosing &#x039B; to scale polylogarithmically with &#x03F5; &#x2212; 1 , an exponential improvement over previous bounds based on energy conservation. For the Hubbard-Holstein model, we numerically compute a bound on &#x039B; that achieves accuracy &#x03F5; , obtaining significantly improved estimates in various parameter regimes. We also establish a criterion for truncating the Hamiltonian with a provable guarantee on the accuracy of time evolution. Building on that result, we formulate quantum algorithms for dynamical simulation of lattice gauge theories and of models with bosonic modes; the gate complexity depends almost linearly on spacetime volume in the former case, and almost quadratically on time in the latter case. We establish a lower bound showing that there are systems involving bosons for which this quadratic scaling with time cannot be improved. By applying our result on the truncation error in time evolution, we also prove that spectrally isolated energy eigenstates can be approximated with accuracy &#x03F5; by truncating local quantum numbers at &#x039B; = polylog ( &#x03F5; &#x2212; 1 ) .

Tong, Yu↗

Absolute beam emittance measurements at RHIC using ionization profile monitors

In the past, comparisons between emittance measurements obtained using ionization profile monitors, Vernier scans (using as input the measured rates from the zero degree counters, or ZDCs), the polarimeters and the Schottky detectors evidenced significant variations of up to 100%. In this report we present studies of the RHIC ionization profile monitors (IPMs). After identifying and correcting for two systematic instrumental errors in the beam size measurements, we present experimental results showing that the remaining dominant error in beam emittance measurements at RHIC using the IPMs was imprecise knowledge of the local beta functions. After removal of the systematic errors and implementation of measured beta functions, precise emittance measurements result. Also, consistency between the emittances measured by the IPMs and those derived from the ZDCs was demonstrated.

43 PARTICLE ACCELERATORS↗