Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “environmental contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Ion-Specific Precipitation of Extractants Enables Rare-Earth Separation and Wastewater Remediation from Solvent Extraction of Critical Elements

The increasing demand for rare-earth elements (REEs) necessitates sustainable recovery strategies, particularly from secondary sources, such as electronic waste. Solvent extraction is the primary industrial method for REE separation; however, the unintentional dissolution of extractants into wastewater poses serious environmental risks, leading to organic contamination and process inefficiencies. Existing wastewater treatment methods struggle to remove these persistent pollutants, underscoring the need for innovative recovery approaches. Herein, we present a ligand-mediated precipitation strategy that simultaneously recovers REEs and removes dissolved extractants from solvent extraction wastewater. We show that residual extractants in the aqueous phase can selectively bind REEs, inducing their precipitation while leaving transition metals in solution. By integrating FTIR spectroscopy, EDS, XPS, EXAFS, and SAXS, we elucidate the mechanism of ion-specific precipitation and the local coordination environment of metal ions in the precipitate. Importantly, we demonstrate that the precipitated extractants can be efficiently recovered and reused, providing a closed-loop solution that enhances sustainability. Applying this method to leachates from samarium–cobalt (Sm–Co) and neodymium–iron–boron (NdFeB) mixed magnets, we achieve highly selective REE precipitation under mild conditions, demonstrating a scalable and cost-effective pathway for REE recovery, wastewater purification, and extractant recycling. In conclusion, by integrating element-specific ligand-mediated precipitation with extractant reuse, this work offers a transformative approach to REE separation that reduces the environmental impact while improving resource efficiency.

E-waste↗

Filaments in Carbonaceous Meteorites: Mineral Crystals, Modern Bio-Contaminants or Indigenous Microfossils of Trichomic Prokaryotes?

Environmental (ESEM) and Field Emission Scanning Electron Microscopy (FESEM) investigations have resulted in the detection of a large number of complex filaments in a variety of carbonaceous meteorites. Many of the filaments were observed to be clearly embedded the rock matrix of freshly fractured interior surfaces of the meteorites. The high resolution images obtained combined with tilt and rotation of the stage provide 3-dimensional morphological and morphometric data for the filaments. Calibrated Energy Dispersive X-ray Spectroscopy (EDS) and 2-D elemental X-ray maps have provided information on the chemical compositions of the filaments and the minerals of the associated meteorite rock matrix. These observations are used to evaluate diverse hypotheses regarding the possible abiotic or biogenic nature of the filaments found embedded in these meteorites.

Hoover, Richard B.↗

Innovative Biomonitoring and Remediation of Heavy Metals Using Phytotechnologies at the Savannah River Site (SRS) Coal Combustion Product (CCP) Impoundment Sites

The Savannah River Site (SRS) contains legacy coal combustion product (CCP) impoundments that are impacted by elevated concentrations of heavy metals and radionuclides, posing long-term risks to soil health, ecosystem functioning, and environmental sustainability. Traditional environmental monitoring approaches rely primarily on chemical analyses to quantify contaminant concentrations but often provide limited information regarding biological responses or ecosystem recovery. This project addressed these limitations by integrating environmental chemistry, microbial ecology, artificial intelligence (AI), and bioremediation into a comprehensive framework for environmental diagnostics and restoration of contaminated soils. The overarching goal of this collaborative project between Florida A&M University (FAMU) and the University of Georgia's Savannah River Ecology Laboratory (SREL) was to develop innovative biomonitoring and remediation strategies for heavy metal-contaminated CCP impoundment sites at the Savannah River Site. Specifically, the project sought to (i) characterize heavy metal contamination, (ii) determine microbial responses to contamination, (iii) isolate indigenous heavy metal-resistant microorganisms for remediation applications, (iv) develop a microbial ecological health index using machine learning, and (v) optimize fungal-mediated bioremediation using artificial intelligence.

01 COAL, LIGNITE, AND PEAT↗

A multi-scale temperature-based strategy to map hydrologic exchange flows in highly dynamic systems

Mapping and quantifying hydrologic exchange flows (HEFs) is critical to environmental monitoring and remediation at contaminated sites; however, these objectives are challenging in highly dynamic systems, e.g., along dam-regulated rivers, where HEFs vary rapidly. Direct seepage measurements are labor-intensive and difficult to automate, whereas indirect (e.g., thermal) and remote sensing methods have potential to allow continuous monitoring with limited field effort. We present a preliminary assessment of a multi-scale temperature-based strategy for monitoring HEFs along the Hanford Reach of the Columbia River, in eastern WA, United States. Five thermal methods were assessed. First, a vertical temperature profile (VTP) was installed into the streambed. The VTP data were analyzed using a data assimilation algorithm designed for automated real-time estimation in dynamic systems. Second, a thermal infrared (TIR) camera was used in roving surveys to identify seeps. Third, a TIR camera was stationed at the VTP site to collect images at 1-h intervals. Together, the two TIR datasets provided a basis to assess the potential for drone-based TIR. Fourth, temperature was measured at the sediment/water interface to assess fiber-optic distributed temperature sensing. Fifth, imagery from the ECOSTRESS satellite mission was acquired to assess the potential of spaceborne thermal monitoring. Based on our preliminary assessment, VTP, TIR, and bed temperature measurements provide complementary spatial coverage, temporal sampling, and resolution; these methods have potential for long-term, automated monitoring of HEFs. The publicly available spaceborne imagery, however, proved inadequate because of insufficient spatial resolution and data gaps resulting from cloud cover and revisit frequency.

54 ENVIRONMENTAL SCIENCES↗

National Oceanic and Atmospheric Administration /NOAA/ contamination monitoring instrumentation

The JPL has designed and built a plume contamination monitoring package to be installed on a NOAA environmental services satellite. The package is designed to monitor any condensible contamination that occurs during the ignition and burn of a TE-M-364-15 apogee kick motor. The instrumentation and system interface are described, and attention is given to preflight analysis and test.

Maag, C. R.↗

Launch Complex 39B, SWMU 009, 2023 Performance Monitoring and Air Sparge Expansion Construction Completion Report, Kennedy Space Center, Florida

The 2023 Performance Monitoring and Construction Completion Report (PM-CCR) presents the findings, observations, and results for Air Sparging (AS) operations and expansion activities, as well as sitewide groundwater monitoring for Launch Complex 39B (LC39B), Solid Waste Management Unit (SWMU) 009, at Kennedy Space Center (KSC), Florida. The reporting period for activities covered under this PM-CCR is from January 1, 2023, to December 31, 2023. At LC39B, AS operations began in 2017 in the area west of the launch pad, in the liquid oxygen (LOX) tank area located northwest of the launch pad, and in an area outside of the perimeter fence to protect nearby Outstanding Florida Waters (OFW). The LC39B AS system was installed with 279 AS wells to depths ranging from 23 to 60 feet below land surface (bls), including the sump, correlating to top of screen depths ranging from 20 to 57 feet bls. In December 2022, a total of 22 AS wells were abandoned to support launch pad crane operations, and in November 2023, the system was expanded with five additional AS wells installed to 13 or 17 feet bls near the LOX tank. The remedial objective of the LC39B AS Interim Measure (IM) is to actively decrease concentrations of contaminants of concern (COCs) in groundwater, specifically trichloroethene (TCE), cis-1,2-Dichloroethene (cDCE), and vinyl chloride (VC), to less than their respective Natural Attenuation Default Concentrations (NADCs), so LC39B can transition into a Long-Term Monitoring (LTM) program. This PM-CCR presents the following information for LC39B: • AS system operations and maintenance (O&M) (Year 7 of operation) from January 2023 to December 2023, to include AS trailer relocation in March 2023 and subsequent replacement and re-start in June 2023. • Construction completion details for AS system expansion, which included installation of five new AS wells and one new monitoring well in November 2023. As part of expansion activities, soil samples were also collected for petroleum analysis; no exceedances were identified, and no further investigation for petroleum is warranted. • Performance monitoring results for groundwater sampling events conducted in May/June 2023 (30 wells) and November 2023 (31 wells) in the AS IM area and in the Low Concentration Plume (LCP) areas located north and east of the launch pad for volatile organic compound (VOC) analysis. • Sampling results for one monitoring well, LOX-IW0012S, which is sampled for aluminum on an annual basis (May/June 2023). This well was resampled in November 2023 for both total and dissolved aluminum. Due to a communication error with the laboratory, the May/June 2023 sample was analyzed for total aluminum only. • Groundwater sampling results for per- and polyfluoroalkyl substances (PFAS) collected from seven monitoring wells during the May/June 2023 event to further investigate the Former Sewage Treatment Plant #6 and Percolation Pond area, west of the launch pad. O&M and performance monitoring results show that the AS system at LC39B is operating as designed and meeting performance criteria. Overall runtime was 45 percent (%) during the reporting period (January to December), but the operational runtime was 78% during the timeframe when the system could run (June to December). The most significant downtime contributor was post-launch crane operations following the Artemis launch on November 16, 2022, which lasted until June 2023. During that timeframe, the AS trailer at LC39B was relocated to another KSC remediation site (Wilson Corners) and was subsequently replaced with the AS trailer from the Paint & Oil Locker (POL) remediation site at KSC to resume AS system operations. Performance monitoring results in the AS IM and LCP areas continue to show reduction in COC concentrations over time when compared to baseline levels. In 2023, only one monitoring well (MW0048) detected a COC exceeding its NADC (VC at 740 micrograms per liter [µg/L]), which marks the baseline result for this new well installed during system expansion. Across the rest of the site, VC concentrations have declined or remained stable during the 2023 sampling events. Excluding MW0048, the highest VC result in 2023 was during the May/June sampling event with a concentration of 63 µg/L at MW0032, which is located near MW0048 and the AS expansion area by the LOX tank. TCE was detected in select monitoring wells in the IM area in 2023, but only two locations exceeded the State of Florida Groundwater Cleanup Target Level (GCTL): MW0032 (21 µg/L in May/June 2023 and 9.1 µg/L in November 2023) and MW0036 (5.0 µg/L in November 2023). MW0036 is also located near the LOX tank, on the north side, where the AS system is still operational (Zone Z4). cDCE and trans-1,2-dichloroethene concentrations were less than laboratory method detection limits or their respective GCTLs in all wells sampled in 2023. Near the OFW located northwest of the launch complex, all COC concentrations were less than laboratory method detection limits from monitoring wells (MW0039, MW0040, and LOXTA0002S) sampled in 2023. Aluminum results from LOX-IW0012S, which has been sampled routinely since 2006, detected a total aluminum concentration of 3,900 µg/L during the May/June 2023 sampling event. Results from the November 2023 event detected 5,700 µg/L for total aluminum and 5,500 µg/L for dissolved aluminum. These concentrations slightly decreased from the previous year but remain relatively consistent with historical detections. Aluminum will continue to be sampled on an annual basis at this well as results still exceed the GCTL of 200 µg/L and the Upper Limit of the KSC Background Concentration of 280 µg/L. PFAS results detected nine different PFAS compounds (out of 32 analyzed) from seven wells sampled. Two PFAS compounds, perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA), currently have FDEP Provisional GCTLs of 70 nanograms per liter (ng/L). All seven samples collected resulted in concentrations less than the FDEP Provisional GCTLs for both PFAS compounds; no exceedances were observed. PFOS and PFOA also have assigned United States Environmental Protection Agency (USEPA) Maximum Contaminant Levels (MCLs) of 4 nanograms per liter (ng/L). None of the PFOS results exceeded the USEPA MCLs. PFOA was detected in two samples above the USEPA MCL at concentrations of 5.8 ng/L (ECS-IW0009I) and 5.5 ng/L (ECS-IW0009S). Three other PFAS compounds, perfluorohexanesulfonic acid (PFHxS), perfluoro-n-nonanoic acid (PFNA), and hexafluoropropylene oxide dimer acid (GenX), currently have USEPA MCLs of 10 ng/L. PFHxS, PFNA, and GenX were not detected at concentrations greater than their respective USEPA MCLs in any of the seven wells. PFAS compounds without FDEP Provisional GCTLs or USEPA MCLs were screened against USEPA RSLs. No other detections exceeded their respective USEPA RSLs. Additional PFAS sampling will be conducted as part of a future PFAS Site Assessment. Based on O&M activities and performance monitoring, the following is recommended for LC39B: • Continue with Year 8 AS system operation within Zone Z4, which includes the AS expansion area. Zone Z3, which has been off since 2018, should remain off as no rebound has been observed. Zones Z1 and Z2, which were turned off at the end of 2022, will remain shut down as monitoring well results have consistently been below GCTLs or have low-level detections with stable or decreasing trends (Meeting Minute 2402-M10, Decision 2402-D30). • Continue with performance monitoring in 2024 with the same monitoring well network as 2023, except with the addition of MW0048 in both semi-annual events. Baseline concentrations for this well were collected during the November 2023 performance monitoring event. Semi-annual sampling should be planned for the May 2024 and November 2024 timeframes (Meeting Minute 2402-M10, Decision 2402-D31). • Continue sampling monitoring well, LOX-IW0012S, for aluminum (total and dissolved) on an annual basis in May 2024. It is also recommended to re-develop this well prior to the next sampling event (Meeting Minute 2402-M10, Decision 2402-D32). The above recommendations for LC39B were presented at the February 2024 KSCRT Meeting, with Team consensus reached on the path forward. The contents of this PM-CCR were also presented at this meeting.

Deborah M Wilson↗

Borehole breakout modeling in arkose and granite rocks

The existence of a deep borehole in the Earth’s crust disturbs the local stresses and creates a stress concentration that may result in breakout and damage to the borehole. Maintaining wellbore integrity mitigates environmental impacts such as groundwater contamination, gas leakage to the atmosphere, and fluid spills and seepage at the surface. In this paper, the stability of deep boreholes (5 km) is examined by laboratory experiments and numerical models in the context of nuclear waste disposal in Israel. Two rock types in southern Israel are considered: the crystalline basement (granite) and the Zenifim Formation (arkose). A series of room-temperature triaxial rock deformation experiments were conducted at different confining pressures. This mechanical characterization was then used to parameterize the elastic properties and damage behavior of the rocks. This facilitated modeling the stability of the deep boreholes by two different formulations of damage rheology: a dynamic-oriented formulation used to model deformation immediately after the creation of the open hole and a quasi-static formulation used to model longer stress corrosion regime. The calibrated modeling results indicate greater stability with Zenifim arkose than the crystalline granite for deep borehole conditions despite the granite having a greater triaxial compressive strength. Dissipation associated with dilation and porous compaction in the arkose during deformation plays a significant stabilizing role in the borehole compared to crystalline rocks. These results suggest that common strength-based borehole stability assessment may lead to inaccurate predictions. Three-dimensional modeling of bottom-hole stress conditions and the effects of transient borehole geometry show conventional two-dimensional analysis may not be conservative when predicting borehole damage.

58 GEOSCIENCES↗

Fluorinated ionic liquids as gas chromatographic stationary phases for the separation of volatile per- and polyfluoroalkyl substances

Background Here, the production of fluorinated organic compounds in the manufacturing, semiconductor, and pharmaceutical industries has increased exponentially over the past decade. This rapid growth has created an urgent need for efficient chromatographic platforms capable of selectively separating these compounds from complex mixtures, not only to support industrial quality control and waste management practices, but also to enable reliable environmental monitoring of volatile fluorinated contaminants. Conventional GC stationary phases lack the fluorophilic interactions needed for highly fluorinated analytes. Consequently, there is a clear demand for specialized stationary phases designed to improve chromatographic retention and selectivity for these compounds. Results Three stationary phases composed of fluorinated ionic liquids (ILs) with varied extent of fluorination were prepared to study fluorophilic interactions with fluorinated/non-fluorinated probe molecules by gas chromatography (GC). IL stationary phases featuring linear and branched perfluoroalkyl moieties, as well as a branched alkyl moiety, were systematically investigated. Chromatographic performance was examined using fluorinated compounds and their hydrocarbon analogs, including CF 3 -substituted aromatics, aliphatic alcohols, fluorotelomer alcohols (FTOHs), and perfluoroalkenes. Measurements on 5 m and 20 m columns revealed that the IL possessing branched alkyl provided stronger dispersive and hydrogen bonding interactions toward non-fluorinated aromatic and long-chain alcohols, whereas the fluorinated ILs enhanced retention of highly fluorinated FTOHs and perfluorodecene. Comprehensive two-dimensional GC (GC × GC), using a nonpolar primary column coupled with secondary columns featuring cross-bonded poly(trifluoropropylmethyl siloxane) (Rtx-200 ms), the branched fluorinated IL, or the branched non-fluorinated IL, highlighted complementary selectivity with the branched fluorinated IL providing the strongest interactions with fluorinated analytes. Significance These results demonstrate that fluorinated IL stationary phases are promising alternatives to conventional polysiloxane stationary phases for improving the separation of per- and polyfluoroalkyl substances and related fluorinated compounds. By correlating IL structure with fluorophilic interactions, this work establishes design principles for GC stationary phases that enable enhanced selectivity for highly fluorinated analytes while maintaining complementary interactions with non-fluorinated compounds.

Comprehensive two-dimensional GC↗

A comparative study of machine learning models for predicting the state of reactive mixing

Mixing phenomena are important mechanisms controlling flow, species transport, and reaction processes in fluids and porous media. Accurate predictions of reactive mixing are critical for many Earth and environmental science problems such as contaminant fate and remediation, macroalgae growth, and plankton biomass evolution. Here, to investigate the evolution of mixing dynamics under different scenarios (e.g., anisotropy, fluctuating velocity fields), a finite-element-based numerical model was built to solve the fast, irreversible bimolecular reaction-diffusion equations to simulate a range of reactive-mixing scenarios. A total of 2,315 simulations were performed using different sets of model input parameters comprising various spatial scales of vortex structures in the velocity field, time-scales associated with velocity oscillations, the perturbation parameter for the vortex-based velocity, anisotropic dispersion contrast (i.e., ratio of longitudinal-to-transverse dispersion), and molecular diffusion. The outputs comprised concentration profiles of reactants and products. The inputs to and outputs from these simulations were concatenated into feature and label matrices, respectively, to train 20 different machine learning (ML) models intended to emulate system behavior. These 20 ML emulators, based on linear methods, Bayesian methods, ensemble learning methods, and multilayer perceptrons (MLPs), were trained to classify the state of mixing and predict three quantities of interest (QoIs) characterizing species production, decay (i.e., average concentration, square of average concentration), and degree of mixing (i.e., variances of species concentration). Unsurprisingly, linear classifiers and regressors failed to reproduce the QoIs; however, ensemble methods (classifiers and regressors) and the MLP model accurately classified the state of reactive mixing and the QoIs. Among ensemble methods, random forest and decision-tree-based AdaBoost faithfully predicted the QoIs. At run time, trained ML emulators produced results times faster than the finite-element simulations. Due to their low computational expense and high accuracy, ensemble and MLP models are excellent emulators for these numerical simulations and great utilities in uncertainty quantification exercises, which can require 1,000s of forward model runs.

97 MATHEMATICS AND COMPUTING↗

Sources, seasonal cycling, and fate of plutonium in a seasonally stratified and radiologically contaminated pond

Unlike short-term laboratory experiments, studies at sites historically contaminated with radionuclides can provide insight into contaminant migration behavior at environmentally-relevant decadal timescales. One such site is Pond B, a seasonally stratified reservoir within Savannah River Site (SC, USA) has low levels (μBq L –1 ) of plutonium in the water column. Here, we evaluate the origin of plutonium using high-precision isotope measurements, investigate the impact of water column geochemistry on plutonium cycling during different stratification periods, and re-evaluate long-term mass balance of plutonium in the pond. New isotopic data confirm that reactor-derived plutonium overwhelms input from Northern Hemisphere fallout at this site. Two suggested mechanisms for observed plutonium cycling in the water column include: (1) reductive dissolution of sediment-derived Fe(III)-(oxyhydr)oxides during seasonal stratification and (2) plutonium stabilization complexed strongly to Fe(III)-particulate organic matter (POM) complexes. While plutonium may be mobilized to a limited extent by stratification and reductive dissolution, peak plutonium concentrations are in shallow waters and associated with Fe(III)-POM at the inception of stratification. This suggests that plutonium release from sediments during stratification is not the dominant mechanism driving plutonium cycling in the pond. Importantly, our analysis suggests that the majority is retained in shallow sediments and may become increasingly recalcitrant.

54 ENVIRONMENTAL SCIENCES↗

IER 555: Godiva Benchmark Update CED-2 (Final Design Report)

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) evaluation of the Godiva IV critical assembly, HEU-MET-FAST-086: GODIVA-IV DELAYED-CRITICAL EXPERIMENTS (HMF-086), was completed by Russ Mosteller. Five critical experiment configurations performed at the Los Alamos National Laboratory (LANL) Technical Area (TA)-18 were evaluated as acceptable benchmark cases. The five cases consist of four delayed critical configurations which differ in control rod positions and one prompt critical configuration. All cases calculated a lower $k_{eff}$ than measured by experiment. This data is referred to as the TA-18 Godiva IV benchmark in this report. In 2005, Godiva IV was disassembled for relocation to the Nevada Test Site (NTS), now Nevada National Security Site (NNSS), at the National Criticality Experiments Research Center (NCERC). Following the disassembly and subsequent reassembly and startup of Godiva IV at NCERC, additional information about the Godiva IV components was obtained. An errata note was added to the HMF-086 evaluation in the ICSBEP handbook to provide this new information until a revision to the benchmark evaluation could be performed. In addition to those corrections, there are differences between the Godiva IV assembly at TA-18 and the Godiva IV assembly at NCERC. These differences include both assembly-specific differences (differences in the safety block gap, differences in the control rod positions, a new NCERC Top Hat and contamination shield) as well as environmental differences, such as the size and shape of the experimental building where the assembly is located. An additional model with similar cases, referred to as the NCERC Godiva IV benchmark in this report, will be added to the revised HMF-086 to capture these additional differences. This will provide the best benchmark model of Godiva for use by those performing experiments at NCERC. The IER 555 CED-2 report documents the information that will be updated in the HMF-086 revision, both the corrections to the TA-18 Godiva IV benchmark and the subsequent changes to create a NCERC Godiva IV benchmark. It describes the measurements that will be performed for cases similar to those performed at TA-18. It also describes measurements that will be included in the evaluation as additional data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Costs of Exposure to Industrial Livestock Operations

Concentrated animal feeding operations, particularly hog and poultry farms, have expanded rapidly in North Carolina in recent decades. The air pollution and water contamination they generate cause many environmental and health problems for local communities. Using the universe of farm characteristics and housing transaction data in North Carolina, we recover hedonic estimates of property value impacts from exposure to these industrial livestock operations. Furthermore, our results show large and significant negative impacts on nearby home values, particularly when those properties depend on private wells.

Concentrated Animal Feeding Operation↗

Benchtop Antigen Detection Technique using Nanofiltration and Fluorescent Dyes

The designed benchtop technique is primed to detect bacteria and viruses from antigenic surface marker proteins in solutions, initially water. This inclusive bio-immunoassay uniquely combines nanofiltration and near infrared (NIR) dyes conjugated to antibodies to isolate and distinguish microbial antigens, using laser excitation and spectrometric analysis. The project goals include detecting microorganisms aboard the International Space Station, space shuttle, Crew Exploration Vehicle (CEV), and human habitats on future Moon and Mars missions, ensuring astronaut safety. The technique is intended to improve and advance water contamination testing both commercially and environmentally as well. Lastly, this streamlined technique poses to greatly simplify and expedite testing of pathogens in complex matrices, such as blood, in hospital and laboratory clinics.

Scardelletti, Maximilian C.↗

Launch Complex 39A, SWMU 008 2023 Long-Term Monitoring Report Kennedy Space Center, Florida

The 2023 Long-Term Monitoring (LTM) Report (LTMR) presents the annual and semi-annual groundwater monitoring results for Launch Complex 39A (LC39A), Solid Waste Management Unit (SWMU) 008, at Kennedy Space Center (KSC), Florida. The reporting period covered under this LTMR is from January to December 2023, and represents the first year of site-wide monitoring following Air Sparge (AS) system shutdown at the end of 2022. AS system operation at LC39A began operation in 2015. The AS system consisted of a total of 173 AS wells ranging in depth from 11 to 37 feet below land surface. The overall remedial objective for the AS Interim Measure was to actively decrease concentrations of COCs to less than their respective Florida Department of Environmental Protection Natural Attenuation Default Concentrations, so that LC39A can transition into an LTM program. This objective was achieved in 2022, with 2023 marking Year 1 of the LTM program to monitor the residual groundwater plume. VOC results indicate that COC concentrations have continued to decrease or stabilize, with no rebound observed since AS system shutdown. Vinyl chloride was the only COC detected above its GCTL, with the highest concentration detected at 8.0 μg/L. PFAS results detected 15 different PFAS compounds (out of 32 analyzed) between the six monitoring wells sampled. Two PFAS compounds, perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA), currently have FDEP Provisional GCTLs of 70 nanograms per liter (ng/L). PFOS was detected in one of the six samples above the FDEP Provisional GCTL at a concentration of 200 ng/L. PFOA was not detected above the FDEP Provisional GCTL in any of the six samples. PFOS and PFOA also currently have United States Environmental Protection Agency (USEPA) Maximum Contaminant Levels (MCLs) of 4 ng/L. PFOS was detected in all six samples above the USEPA MCL. PFOA was detected in three of the six samples above the USEPA MCL. Three other PFAS compounds, perfluorohexanesulfonic acid (PFHxS), perfluoro-n-nonanoic acid (PFNA), and hexafluoropropylene oxide dimer acid (GenX), currently have USEPA MCLs of 10 ng/L. PFHxS, PFNA, and GenX were not detected at concentrations greater than their respective USEPA MCLs in any of the six wells. Additional PFAS sampling will occur as part of a PFAS Site Assessment to be conducted in the future. Based on Year 1 LC39A LTM results, recommendations for 2024 are to continue with the second year of LTM in 2024 with the same monitoring well network as Year 1 (18 wells). The three wells that were on a semi-annual schedule will transition to an annual schedule to align with the remaining wells. The next annual event is scheduled for May 2024. The three wells that were found to be inadvertently destroyed will be properly abandoned and a replacement well in the vicinity of former monitoring well 21ST-MW0030I will be installed. This new well will be added to the LTM sampling plan upon installation.

Deborah M. Wilson↗

Optimizing Ventilation Using Low-Cost Sensors to Improve Health, Safety, and Energy Efficiency

Air is the primary carrier of hazards within a space, whether it be hazardous bi-products of research activities or airborne pathogens. As a result, building ventilation is the primary defense against unseen airborne hazards. Critical laboratory facilities already demand the need for effective mitigation of exposure to research-related, airborne hazards, providing a proving ground for effective ventilation strategies that optimize safety of occupants and reduce energy use. The heart of smart laboratory building operation is dynamic, analytics-based ventilation, which requires an intimate knowledge of building environmental conditions achieved through contaminant-detection systems. Unfortunately, currently available contaminant-detection solutions are expensive, elaborate systems that raise barriers for building managers on a limited budget. Through the successful deployment of a novel low-cost, modular sensor technology, we have developed a demand-control ventilation protocol effective in improving safety and reducing energy in the critical laboratory environment. In this session, we will highlight best practices and lessons learned through this deployment that can be applied beyond laboratories without breaking the bank. This paper describes a low-cost solution for providing a safe, healthy building environment and reducing energy use through effective, efficient ventilation.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Optimizing Ventilation Using Low-Cost Sensors to Improve Health, Safety, and Energy Efficiency

Air is the primary carrier of hazards within a space, whether it be hazardous byproducts of laboratory research activities or airborne pathogens. As a result, building ventilation is a primary defense against unseen airborne hazards. Critical laboratory facilities require effective mitigation of exposure to research-related, airborne hazards, providing a proving ground for effective ventilation strategies that optimize safety of occupants and reduce energy use. The heart of smart laboratory building operation is dynamic, analytics-based ventilation, which requires an in-depth intimate knowledge of building environmental conditions achieved through contaminant-detection systems. Unfortunately, currently many contaminant-detection solutions are expensive, elaborate systems that raise barriers for building managers. Through the successful deployment of a novel low-cost, modular sensor technology, we have developed a demand-control ventilation protocol effective in improving safety and reducing energy in critical laboratory environments. In this article, we will highlight best practices and lessons learned through this deployment that can be applied beyond laboratories. This article describes a low-cost sensor to support providing a safe, healthy building environment and reduce energy use through effective and efficient ventilation.

dynamic management of indoor air quality↗

Alpha-Imaging Detector System Development for Large Area Monitoring

Effective management and disposal of legacy nuclear waste are essential for ensuring safe work environments and minimizing environmental impacts. Monitoring airborne actinide contamination is particularly critical due to the high internal dose potential of alpha-emitting radionuclides. Traditional continuous air monitoring systems (CAMs) used in the industry are limited in the volume of air they can sample, potentially leading to inaccurate radiation detection over large areas. For example, in 2018, elevated levels of airborne Plutonium-239 were detected beyond the controlled areas of the Hanford Plutonium Finishing Plant, highlighting the potential risks to both plant workers and nearby residents. To address these challenges, high-efficiency particulate absorbing (HEPA) air purifiers can enhance air flow by up to 1.5 orders of magnitude, thereby increasing monitoring efficiency and providing a cost-effective solution for large-area surveillance. To quantify the activities of alpha-emitting radionuclides on HEPA filters, the Savannah River National Laboratory is developing an advanced alpha-imaging detection system. This system includes scintillating materials combined with a digital scientific camera. A significant concern in operating such a large-area airborne monitoring system is the handling of HEPA filters, which may be contaminated with radioactive particles. To mitigate these hazards, it is crucial to ensure that any contamination is securely fixed onto the filters. Efforts have been made to optimize the sensitivity of scintillator-epoxy composites and apply them to HEPA filters. These materials were characterized using fluoroscence spectroscopy. These techniques confirmed the purity of the raw materials, the dispersion of scintillators in the epoxy matrix, and the stability of their optical and structural properties post-modification. The optimal scintillator-epoxy composite was selected for use on alpha-spiked HEPA filters to evaluate the efficiency of the sprayer. HEPA filters, embedded with alpha particles collected by an air purifier deployed in an airborne radiation area, have been tested to assess detection efficiency. Future work will focus on employing multiple imaging sensors simultaneously to enhance sensitivity across different regions of the HEPA filter.

Pham, Phuong [Savannah River National Laboratory (↗

Evaluation and mitigation of trace 210Pb contamination on copper surfaces

Clean materials are required to construct and operate many low-background physics experiments. High-purity copper has found broad use because of its physical properties and availability. In this paper, we describe methods to assay and mitigate Pb-210 contamination on copper surfaces, such as from exposure to environmental radon or coming from bulk impurities. We evaluated the efficacy of wet etching on commercial samples and observed that Po-210 contamination from the copper bulk does not readily pass into solution. During the etch, the polonium appears to trap at the copper-etchant boundary, such that it is effectively concentrated at the copper surface. We observed a different behavior for Pb-210; high-sensitivity measurements of the alpha emissivity versus time indicate the lowest level of Pb-210 contamination ever reported for a commercial copper surface: 0 +/- 12 nBq/cm2 (1-sigma). Additionally, we have demonstrated the effectiveness of mitigating trace Pb-210 and Po-210 surface backgrounds using custom, high-purity electroplating techniques. These approaches were evaluated utilizing assays performed with an XIA UltraLo-1800 alpha spectrometer.

radon, copper, copper cleaning, dark matter, Pb-21↗