Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron guns”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Anomalous auroral electron distributions due to an artificial ion beam in the ionosphere

Results are reported for the perturbation of the auroral ionosphere by the operation of an ion gun which injected about 100 mA of 25-eV Ar(+) ions at upgoing pitch angles over a discrete auroral arc. The major effects observed were the excitation of intense broadband electric field fluctuations at zero-10 kHz, and the appearance of streaming and isotropic heating in different parts of superthermal electron velocity space. A scenario is explored in which electron runaway or streaming is expected between the trapping speed and the critical velocity for cyclotron interactions with the waves, where the streaming electrons carry the current that would be carried by thermals or energetic electrons in the absence of the waves. A current of about 1.0 microA/sq m is carried by the streaming electrons. The gun-associated electrons were anomalous in the sense that their anisotropy was the opposite of that observed in the natural aurora.

Moore, T. E.↗

High energy electron diffraction instrument with tunable camera length

Ultrafast electron diffraction (UED) stands as a powerful technique for real-time observation of structural dynamics at the atomic level. In recent years, the use of MeV electrons from radio frequency guns has been widely adopted to take advantage of the relativistic suppression of the space charge effects that otherwise limit the temporal resolution of the technique. Nevertheless, there is not a clear choice for the optimal energy for a UED instrument. Scaling to beam energies higher than a few MeV does pose significant technical challenges, mainly related to the inherent increase in diffraction camera length associated with the smaller Bragg angles. In this study, we report a solution by using a compact post-sample magnetic optical system to magnify the diffraction pattern from a crystal Au sample illuminated by an 8.2 MeV electron beam. Our method employs, as one of the lenses of the optical system, a triplet of compact, high field gradients (>500 T/m), small-gap (3.5 mm) Halbach permanent magnet quadrupoles. Shifting the relative position of the quadrupoles, we demonstrate tuning the magnification by more than a factor of two, a 6× improvement in camera length, and reciprocal space resolution better than 0.1 Å –1 in agreement with beam transport simulations.

47 OTHER INSTRUMENTATION↗

Preliminary AEM study of the microstructure and composition of metal particles in ordinary chondrites

The purpose of this study is to examine the microstructure and composition of the metal particles in ordinary chondrites using analytical electron microscopy (AEM) techniques. Since the phases produced within the metal particles are very fine, the application of various AEM techniques for structural and chemical characterization is critical. However, thin specimen preparation for AEM study has proven very difficult because of the matrix silicate which is present. This is the first AEM study of the metal particles in chondrites. A type 6 chondrite, Saint Severin (LL6), was selected for examination because the metal phases have been reheated into the single phase taenite region (greater than 700 C), and cooled slowly to lower temperatures. A combination of electron optical instruments was employed including a field emission gun (FEG) JEOL 840F high resolution scanning electron microscope (HRSEM), a JEOL 6300F FEG-HRSEM, a Philips 400T AEM, and a JEOL 733 electron probe microanalyzer (EPMA).

Yang, C. W.↗

Performance of computer-designed small-size multistage depressed collectors for a high-perveance traveling wave tube

Computer designed axisymmetric 2.4-cm-diameter three-, four-, and five-stage depressed collectors were evaluated in conjunction with an octave bandwidth, high-perveance, and high-electronic-efficiency, griddled-gun traveling wave tube (TWT). Spent-beam refocusing was used to condition the beam for optimum entry into the depressed collectors. Both the TWT and multistage depressed collector (MDC) efficiencies were measured, as well as the MDC current, dissipated thermal power, and DC input power distributions, for the TWT operating both at saturation over its bandwidth and over its full dynamic range. Relatively high collector efficiencies were obtained, leading to a very substantial improvement in the overall TWT efficiency. In spite of large fixed TWT body losses (due largely to the 6 to 8 percent beam interception), average overall efficiencies of 45 to 47 percent (for three to five collector stages) were obtained at saturation across the 2.5-, to 5.5-GHz operating band. For operation below saturation the collector efficiencies improved steadily, leading to reasonable ( 20 percent) overall efficiencies as far as 6 dB below saturation.

Ramins, P.↗

Tethered Pyrotechnic Apparatus for Acquiring a Ground Sample

A proposed alternative design for the balloon-borne ground-sampling system described in the immediately preceding article would not rely on free fall to drive a harpoonlike sample-collecting device into the ground. Instead, the harpoon-like sample-collecting device would be a pyrotechnically driven, tethered projectile. The apparatus would include a tripod that would be tethered to the gondola. A gun for shooting the projectile into the ground would be mounted at the apex of the tripod. The gun would include an electronic trigger circuit, a chamber at the breech end containing a pyrotechnic charge, and a barrel. A sabot would be placed in the barrel just below the pyrotechnic charge, and the tethered projectile would be placed in the barrel just below the sabot. The tripod feet would be equipped with contact sensors connected to the trigger circuit. In operation, the tripod would be lowered to the ground on its tether. Once contact with the ground was detected by the sensors on all three tripod feet, the trigger circuit would fire the pyrotechnic charge to drive the projectile into the ground. (Requiring contact among all three tripod feet and the ground would ensure that the projectile would be fired into the ground, rather than up toward the gondola or the balloon.) The tethered projectile would then be reeled back up to the gondola for analysis of the sample.

Jones, Jack↗

Gridded RF Gun Design for SRF Linac Applications

The thermionic gridded gun is described which generates short electron bunches for further acceleration in a Nb3Sn conduction cooled SRF linac. The gun is built into the first cavity of the 250 keV injector [1] for the 20 kW, 10 MeV, 1.3 GHz CW conduction cooled one-cavity linac. The beam current is 2 mA. The RF gun design is presented as well as the results of perveance measurements, which are in a good agreement with the design parameters. The design of the RF resonator of the gun is presented also. The beam generated by the gun is matched to the injector to provide lack of current interception in the SRF cavity.

43 PARTICLE ACCELERATORS↗

Long-Life/Low-Power Ion-Gun Cathode

New cathode has form of hollow tube through which gas enters region of high electron density, produced by electric discharge with auxiliary electrode referred to as "keeper." Ion-gun cathode emits electrons that bombard gas in chamber. Ions accelerated out of source are used to dope semiconductor material.

Fitzgerald, D. J.↗

Thermionic microwave gun for terahertz and synchrotron light sources

Conventional thermionic microwave and radiofrequency (RF) guns can offer high average beam current, which is important for synchrotron light and terahertz (THz) radiation source facilities, as well as for industrial applications. For example, the Advanced Photon Source at Argonne National Laboratory is a national synchrotron radiation light source research facility that utilizes thermionic RF guns. Yet, these existing thermionic guns are bulky, difficult to handle and install, easily detuned, very sensitive to thermal expansion, and are due for a major upgrade and replacement. Here, we present the design of a new, more stable and reliable gun with optimized electromagnetic performance, improved thermal engineering and a more robust cathode mounting technique, which is a critical step to improve the performance of existing and future light sources, industrial accelerators, and electron beam-driven terahertz sources. We will also present a fabricated gun prototype and show results of high-power and beam tests.

47 OTHER INSTRUMENTATION↗

Electron-only reconnection and associated electron heating and acceleration in PHASMA

In this work, using incoherent Thomson scattering, electron heating and acceleration at the electron velocity distribution function (EVDF) level are investigated during electron-only reconnection in the PHAse Space MApping (PHASMA) facility. Reconnection arises during the merger of two kink-free flux ropes. Both push and pull type reconnection occur in a single discharge. Electron heating is localized around the separatrix, and the electron temperature increases continuously along the separatrix with distance from the X-line. The local measured gain in enthalpy flux is up to 70% of the incoming Poynting flux. Notably, non-Maxwellian EVDFs comprised of a warm bulk population and a cold beam are directly measured during the electron-only reconnection. The electron beam velocity is comparable to, and scales with, electron Alfvén speed, revealing the signature of electron acceleration caused by electron-only reconnection. The observation of oppositely directed electron beams on either side of the X-point provides “smoking-gun” evidence of the occurrence of electron-only reconnection in PHASMA. 2D particle-in-cell simulations agree well with the laboratory measurements. The measured conversion of Poynting flux into electron enthalpy is consistent with recent observations of electron-only reconnection in the magnetosheath [Phan et al., Nature 557, 202 (2018)] at similar dimensionless parameters as in the experiments. The laboratory measurements go beyond the magnetosheath observations by directly resolving the electron temperature gain.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The hot plasma environment and floating potentials of an electron-beam-emitting rocket in the ionosphere

The plasma environment surrounding the Echo III accelerator payload is examined with an extensive array of particle sensors. Suprathermal electrons are produced isotropically around the payload during the gun firings and decay away in approximately 32 ms. The largest directional intensities of this component are observed at the higher altitudes. Quick echo electrons are also observed to produce suprathermal electrons when they encounter the payload. The hot electrons surrounding the accelerator payload during gun injections bring sufficient charge to the payload to neutralize it provided the loss of charge by secondary production on the payload skin is small. Since the hot population exists for tens of milliseconds after the gun turnoff, it results in driving the payload up to 4 volts negative during this time. Quick echo electrons creating suprathermal electrons around the payload also drive the payload to a few volts negative.

Arnoldy, R. L.↗

GRIDDED RF GUN DESIGN FOR SRF LINAC APPLICATIONS

The thermionic gridded gun is described which gener-ates short electron bunches for further acceleration in a Nb3Sn conduction cooled SRF linac. The gun is built into the first cavity of the 250 keV injector [1] for the 20 kW, 10 MeV, 1.3 GHz CW conduction cooled one-cavity linac. The beam current is 2 mA. The RF gun design is presented as well as the results of perveance measure-ments, which are in a good agreement with the design parameters. The design of the RF resonator of the gun is presented also. The beam generated by the gun is matched to the injector to provide lack of current inter-ception in the SRF cavity.

Gonin, I.↗

Extracting symplectic maps for space-charge dominated beams

Symplecticity of transfer maps is important for reliable evaluation of space-charge dominated beams in accelerators. Unfortunately, most simulation codes that include collective effects, such as space charge, do not use canonical phase-space variables and therefore are not symplectic in the presence of electromagnetic fields. In this paper, we present a numerical method to extract local linear symplectic transfer maps using particle tracking simulation code for space-charge dominated beams. We demonstrate this method for the photoinjector (113 MHz SRF gun) section of the Coherent electron Cooling (CeC) Proof of Principle (POP) experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Waves generated in the vicinity of an argon plasma gun in the ionosphere

Wave and particle observations were made in the close vicinity of an argon plasma gun carned to over 600 km altitude on a sounding rocket. The gun was carned on a subpayload, separated from the main payload early in the flight. Twelve-second argon ion ejections were energized alternately with a peak energy of 100 or 200 eV. They produced waves, with multiple harmonics, in the range of ion cyclotron waves, 10 to 1000 Hz at rocket altitudes. Many of these waves could not be identified as corresponding to the cyclotron frequencies of any of the ions, argon or ambient, known to be present. In addition, the wave frequencies were observed to rise and fall and to change abruptly during a 12-s gun operation. The wave amplitudes, near a few hundred Hertz, were of the order of O. 1 V/m. Some of the waves may be ion-ion hybrid waves. Changes in ion populations were observed at the main payload and at the subpayload during gun operations. A gun-related, field-aligned, electron population also appeared.

Cahill, L. J., Jr.↗

Olivine Compositional Variation of Asteroid Ryugu Samples: Possible Precursors of Ryugu’s Parent Asteroid

JAXA’s Hayabusa2 spacecraft successfully recovered samples from Cb-type asteroid Ryugu and returned samples are now under detailed scrutiny by the international community. The ongoing initial analysis has so far revealed that the Ryugu samples are pristine primitive asteroidal materials mostly composed of secondary minerals such asphyllosilicates, carbonates, Fe sulfides and magnetite associated with organic matter [e.g., 1]. However, some samples contain small amounts of anhydrous silicates and oxides such as olivine that are thought to be the precursors of the Ryugu parent asteroid. Their sizes are mostly <5 mm, and detailed mineralogical analysis is possible using an electron microprobe with field emission gun (FE-EPMA). Here we report results of our extensive FE-EPMA analysis of an hydrous minerals focusing on olivine to compare with literature chondritic data. We also performed synchrotron XRD of olivine crystals to evaluate the shock degree of Ryugu samples. These analyses allow us to discuss the formation of Ryugu in light of the solar system early evolution.

T Mikouchi↗

Laboratory Instruments Available to Support Space Station Researchers at Marshall Space Flight Center

A number of research instruments are available at NASA's Marshall Space Flight Center (MSFC) to support ISS researchers and their investigations. These modern analytical tools yield valuable and sometimes new informative resulting from sample characterization. Instruments include modern scanning electron microscopes equipped with field emission guns providing analytical capabilities that include angstron-level image resolution of dry, wet and biological samples. These microscopes are also equipped with silicon drift X-ray detectors (SDD) for fast yet precise analytical mapping of phases, as well as electron back-scattered diffraction (EBSD) units to map grain orientations in crystalline alloys. Sample chambers admit large samples, provide variable pressures for wet samples, and quantitative analysis software to determine phase relations. Advances in solid-state electronics have also facilitated improvements for surface chemical analysis that are successfully employed to analyze metallic materials and alloys, ceramics, slags, and organic polymers. Another analytical capability at MSFC is a mganetic sector Secondary Ion Mass Spectroscopy (SIMS) that quantitatively determines and maps light elements such as hydrogen, lithium, and boron along with their isotopes, identifies and quantifies very low level impurities even at parts per billion (ppb) levels. Still other methods available at MSFC include X-ray photo-electron spectroscopy (XPS) that can determine oxidation states of elements as well as identify polymers and measure film thicknesses on coated materials, Scanning Auger electron spectroscopy (SAM) which combines surface sensitivity, spatial lateral resolution (approximately 20 nm), and depth profiling capabilities to describe elemental compositions in near surface regions and even the chemical state of analyzed atoms. Conventional Transmission Electron Microscope (TEM) for observing internal microstructures at very high magnifications and the Electron Probe Micro-analyzer (EPMA) for very precise microanalysis are available as needed by the researcher. Space Station researchers are invited to work with MSFC in analyzing their samples using these techniques.

Panda, Binayak↗

Data sharing helps avoid “smoking gun” claims of topological milestones

Manipulating the topology of electronic bands can realize new states of matter, with possible implications for information technology. A central question is how to tell whether a topological regime has been achieved. Experiments are often guided by a prediction of a distinct and self-explanatory signal called “the smoking gun.” However, in micrometer- or nanometer-scale specimens, phenomenology can mimic the anticipated behavior without containing the exotic states. We show limited data that are consistent with the presence of four topological phenomena; by considering additional data, we identified the most likely origins of the observed patterns as trivial. Finally, we argue that the reliability of smoking gun–type claims can be greatly enhanced by releasing comprehensive datasets, discussing alternative scenarios, and disclosing the total volume of study.

Frolov, S. M. [Univ. of Pittsburgh, PA (United Sta↗

Nb$_{3}$Sn SRF Photogun High Power Test at Cryogenic Temperatures

Superconducting RF (SRF) photoguns are emerging as promising candidates to produce highly stable electrons for Ultra fast Electron Diffraction/Microscopy (EUD/UEM) applications due to the ultrahigh shot-to-shot stability compared to room temperature RF photoguns. SRF technology was prohibitively expensive for industrial use until two recent advancements: Nb 3 Sn and conduction cooling. SRF gun can provide a CW operation capability while consuming only several Watts of RF power which eliminates the need of an expensive high power RF system and saves a facility footprint. Euclid is developing a continuous wave (CW), 1.5-cell, MeV-scale SRF conduction cooled photogun operating at 1.3 GHz. Here, in this paper, we present first high power results of the gun covered with Nb 3 Sn.

43 PARTICLE ACCELERATORS↗

The Electron Drift Technique for Measuring Electric and Magnetic Fields

The electron drift technique is based on sensing the drift of a weak beam of test electrons that is caused by electric fields and/or gradients in the magnetic field. These quantities can, by use of different electron energies, in principle be determined separately. Depending on the ratio of drift speed to magnetic field strength, the drift velocity can be determined either from the two emission directions that cause the electrons to gyrate back to detectors placed some distance from the emitting guns, or from measurements of the time of flight of the electrons. As a by-product of the time-of-flight measurements, the magnetic field strength is also determined. The paper describes strengths and weaknesses of the method as well as technical constraints.

Paschmann, G.↗