Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric load profiles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A dynamic pricing method to manage the impact of EV charging on the grid using RL

This work addresses the challenge of managing electrical vehicle (EV) charging loads on distribution feeders with the increase in deployment of fast charging stations. To mitigate the adverse impacts on feeder health, a novel dynamic grid-informed pricing approach is proposed. This approach leverages reinforcement learning (RL) to determine hourly charging prices based on real-time grid conditions. A synthetic environment was developed to train the reinforcement learning agent. A model of an IEEE 34-bus distribution feeder with EV charging stations has been developed in OpenDSS utilizing Caldera for realistic EV charging profiles. Test cases demonstrate that the dynamic pricing strategy achieves higher energy delivery to the EV end user at a lower cost compared to constant pricing methods, while lowering voltage deviations and congestion. This approach offers more granular price adjustments, responding dynamically to feeder conditions and potentially improving grid stability and efficiency. The communication architecture to implement this dynamic pricing method is described. This research contributes to the development of smart grid-informed charging solutions that can reduce the cost of charging to the end user while also helping the grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Hubble Space Telescope six-battery nickel-cadmium mission simulation test

A simulation test of the six-battery nickel-cadmium mission to determine battery life and electrical power system (EPS) performance characteristics for the Hubble Space Telescope (HST) program, is described. The basic HST power system requirements are to provide power generation, energy storage, and EPS control and distribution for 2.5 years with the nickel-cadmium (NiCd) batteries at an end of life solar array of 2 years. Mission simulation life testing begain in April of 1986, and the batteries have completed their 2.5 year mission requirement. Conditions as close as practical to the actual predicted mission profiles were used. These included solar array degradation, load variations, beta angle changes, temperature changes (with excursions to 10 C), battery reconditioning, safemode simulations, and off-normal roll activities. Discounting system cycling interruptions caused by hardware, software, human error, and periodic updates and revisions, the HST EPS breadboard hardware operated continuously for 30 months and demonstrated the power system's ability to meet the HST requirement.

Jackson, Lorna G.↗

Factors Influencing Grid-connected Heat Pump Water Heater Performance in the Southeast U.S.

Grid-connected heat pump water heaters (HPWH) can shift electrical load while minimizing impacts to hot water availability for occupants. This capability provides a flexible grid resource to utilities seeking to manage peak loads Such load control also can feasibly improve renewable utilization within the utility electric production mix, for instance using off-peak generation during periods with high renewable energy generation. It also offers lower electric bills to customers through increased energy efficiency of HPWH and cuts greenhouse gas emissions. In particular, the Southeast U.S. due to its high penetration of electric water heating presents a promising opportunity for grid-connected HPWHs. This paper builds upon the results of an extensive HPWH load shifting field study conducted in 51 occupied homes in Florida using EcoPort technology (Butzbaugh et al, 2022). In 2022, only an initial evaluation was available. Here, long term load results are available as well as examination of various control strategies and influences. Analysis is conducted for HPWH energy use and load shifting performance based on home occupancy (i.e., low and high) and water heater location (i.e., conditioned and unconditioned) across different temperature profiles. An unexpected outcome of this analysis was the poor performance of HPWHs located in conditioned spaces, possibly because of inadequate air volume from improper installation. We did find higher demand reductions from 2-hour load ups and slightly improved for critical peak signals in the afternoon control periods. As expected, higher occupancy households showed great load reductions.

Fenaughty, Karen↗

Dynamic cycling enhances battery lifetime

Laboratory aging campaigns benchmark and elucidate the complex degradation behavior of lithium-ion batteries, and are critical not only for developing new battery chemistries and cell designs but also for engineering reliable battery management systems. Critically, these laboratory experiments aim to quantify and capture realistic aging mechanisms. In this study, we systematically compare dynamic discharge profiles representative of electric vehicle driving to the well-accepted constant-current profiles. Surprisingly, we discovered that dynamic discharge enhances lifetime substantially compared to constant current discharge. Specifically, for the same average current and voltage window, varying the dynamic discharge profile leads to an increase of up to 38 % in equivalent full cycles at end-of-life. Explainable machine learning reveals the importance of low-frequency current pulses as well as time-induced aging under these realistic discharge conditions. Our work quantifies the importance of evaluating new battery chemistries and designs with realistic load profiles, and highlights the opportunities to revisit our understanding of aging mechanisms at the chemistry, materials, and cell levels.

25 ENERGY STORAGE↗

Impact Analysis of Future Electric Vehicles Using Model of Real Distribution Feeders

Globally, the number of electric vehicles (EVs) continues to increase. This on-going trend poses challenges for power distribution systems. The inclusion of electric vehicle supply equipment (EVSE) should be compatible with a changing energy system, whose structure is becoming increasingly distributed. The impact of future EVs should be analyzed and considered in the system planning and upgrades. In this study, impact analysis of future EVs is conducted for a utility company of U.S. West Coast. Real data of distribution feeders is converted into the GridLAB-D model for running power flow analysis. An estimation of the additional loading of EVs in 2050 is provided by the utility company. Simple mitigation methods are tested to improve voltage profiles and complete this case study.

Xie, Jing↗

Autonomous power expert system

The Autonomous Power Expert (APEX) system was designed to monitor and diagnose fault conditions that occur within the Space Station Freedom Electrical Power System (SSF/EPS) Testbed. APEX is designed to interface with SSF/EPS testbed power management controllers to provide enhanced autonomous operation and control capability. The APEX architecture consists of three components: (1) a rule-based expert system, (2) a testbed data acquisition interface, and (3) a power scheduler interface. Fault detection, fault isolation, justification of probable causes, recommended actions, and incipient fault analysis are the main functions of the expert system component. The data acquisition component requests and receives pertinent parametric values from the EPS testbed and asserts the values into a knowledge base. Power load profile information is obtained from a remote scheduler through the power scheduler interface component. The current APEX design and development work is discussed. Operation and use of APEX by way of the user interface screens is also covered.

Walters, Jerry L.↗

An Energy Service Interface for Distributed Energy Resources

Renewable energy resources, particularly wind and solar photovoltaic, are becoming significant contributors to electric power generation. These re-sources will contribute towards achieving sustainable electric power systems. However, renewable resources will dramatically increase the demand for flexible power system operations. This paper proposes an energy service interface that will allow aggregated distributed energy resources, such as residential loads and inverter-based systems, to participate in NERC-defined smart energy reliability services. Such cyber-physical systems will increase system flexibility by ensuring match between energy supply and energy demand.Aggregation and coordinated dispatch of millions of distributed energy resources will require development of large-scale computing networks. Several smart grid interface-enabling technologies, including IEEE 2030.5, Common Smart Inverter Profile, SunSpec Modbus, and CTA 2045, are discussed. Residential loads are categorized by their static and dynamic energy characteristics to identify services in which they can participate. The business model for the energy services interface as well as probabilistic modeling for resource estimation are highlighted as future considerations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Choosing the Best Carbon Factor for the Job: Exploring Available Carbon Emissions Factors and the Impact of Factor Selection

Over 600 local governments in the United States, including nearly half of the largest 100 cities, have enacted climate action plans that include carbon reduction goals and greenhouse gas inventories (Markolf et al. 2020). The magnitude of these goals ranges from modest reduction targets to carbon neutrality. None will be met without significant contributions from the buildings sector. Understanding how energy efficiency and building electrification impact greenhouse gas emissions requires local, time-sensitive, and forward-looking carbon emissions factors for electricity use in buildings. There are a variety of emissions factors currently available from various sources, including average emissions factors and historical short-run marginal emissions factors. Long-run marginal emissions factors and future-year short-run marginal emissions factors are also now available from the National Renewable Energy Laboratory's (NREL's) Cambium data sets. In this paper, we describe the different carbon emissions factors available, including both conventional sources and newly available options. We discuss the types of analyses each emissions factor is best suited to support. Then, using residential energy efficiency and electrification load profiles, we demonstrate how different conclusions result from different choices of carbon emissions factors. For two grid regions, we explore takeaways of using current versus future-year emissions, short-run versus long-run, and levelized versus single-year values. We include a framework for selecting the best carbon emissions factor for the job.

carbon emissions factors↗

Choosing the Best Carbon Factor for the Job: Exploring Available Carbon Emissions Factors and the Impact of Factor Selection: Preprint

Over 600 local governments in the United States, including nearly half of the largest 100 cities, have enacted climate action plans that include carbon reduction goals and greenhouse gas inventories (Markolf et al. 2020). The magnitude of these goals ranges from modest reduction targets to carbon neutrality. None will be met without significant contributions from the buildings sector. Understanding how energy efficiency and building electrification impact greenhouse gas emissions requires local, time-sensitive, and forward-looking carbon emissions factors for electricity use in buildings. There are a variety of emissions factors currently available from various sources, including average emissions factors and historical short-run marginal emissions factors. Long-run marginal emissions factors and future-year short-run marginal emissions factors are also now available from the National Renewable Energy Laboratory's (NREL's) Cambium data sets. In this paper, we describe the different carbon emissions factors available, including both conventional sources and newly available options. We discuss the types of analyses each emissions factor is best suited to support. Then, using residential energy efficiency and electrification load profiles, we demonstrate how different conclusions result from different choices of carbon emissions factors. For two grid regions, we explore takeaways of using current versus future-year emissions, short-run versus long-run, and levelized versus single-year values. We include a framework for selecting the best carbon emissions factor for the job.

carbon emissions factors↗

End-Use Savings Shapes Measure Documentation: Dispatch Schedule Generation for Demand Flexibility Measures

This supplemental document describes the methodology used for determining the dispatch timing of various EUSS demand flexibility measures. Demand flexibility measures are designed to reduce/dispatch electricity demand in buildings during especially beneficial/critical times. The method used in this work utilizes predictions of building loads to generate a schedule that reflects the periods when the building's daily peak load occurs to support decision making in demand flexibility measures. The dispatch schedule generation method described in this document creates an hourly schedule that includes a load dispatch (peak) window for each day for a whole year based on load prediction, with options using different prediction methods: perfect prediction, bin-sampling method, fixed schedule, and outdoor air temperature (OAT)-based prediction method. The perfect prediction method performs a simulation to obtain the annual load profile as predicted load, representing the scenario of perfect load prediction. The bin-sampling method (1) categorizes days into representative bins by temperature characteristics, (2) performs simulations on sample days from each of those bins to create representative (or predicted) load, and (3) assigns representative loads for all days in a year based on the bin categorization. The fixed schedule method defines uniform start and end time of peak window with assumed fixed daily peak time, for all days in a season or a year. The OAT-based prediction method uses the statistics of OAT (minimum and maximum) as the indicators of peak load, with specified delay response time from building loads to temperature. Given the load prediction, daily peak periods are determined as a time window with specified length in each day that include the predicted daily peak load and with a secondary rule such as maximizing energy saving potential. The dispatch schedule generation method is not a standalone measure and is intended to be combined with other demand flexibility measures that could leverage the peak schedule and apply demand controls on specific systems or devices for demand response, such as measures described in "Measure Documentation - Thermostat Control for Load Shedding" and "Measure Documentation - Thermostat Control for Load Shifting".

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Engineered Multifunctional Composite for Passive Sensing, Power Harvesting, and In Situ Damage Identification with Enhanced Mechanical Performance

A multifunctional fiber-reinforced composite with passive self-sensing, energy-harvesting, and damage detection capabilities is presented. In this work, barium titanate piezoelectric microparticles are deposited on basalt fibers by a scalable, low-cost, environmentally friendly continuous feed-through process. The resulting composite derives a superior interlaminar shear strength from the microparticle-modified fiber–matrix interfaces. The composite also demonstrates passive self-sensing capabilities that produce electrical signals proportional to various dynamic loading events. Vibration and strain-controlled experiments are performed on composite beams to quantify the sensitivity and power output as a function of input acceleration and strain. Furthermore, these composite-generated electrical signals are used to identify in situ damage initiation for structural health monitoring to inform composite damage prior to structural failure. In brief, this truly multifunctional composite simultaneously displays a sensitivity of 0.5–2.6 mV g -1 at a resolution of 0.045–0.20g (g = gravitational acceleration), energy harvesting in the range of nW cc -1 , and prediction of early damage by exhibiting 0.017–1.17 mV peaks in voltage–time history profiles while assuring ≈20% improved interlaminar shear strength.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radio Wave Propagation for Communication on and around Mars: Highlights: Propagation Through Mars Environment - Part 1

We recommend to use the dayside Martian ionosphere as a reflector for global communication, because the dayside ionosphere has stable density peak and usable critic frequency. This is very crucial for the future Mars ground to around communication. The dayside ionosphere has been well modeled as a Chapman layer. We suggest to perform the Martian nightside ionospheric modeling study. Because the nightside ionosphere has very little measurements available, we propose to drop a digital ionosond instrument into the Mars surface for data collection. Even though the Martian tropospheric radio refractivity has small value, it still can cause the ray bending and multipath effects. We recommend to perform an accurate calculation on excess phase and group delays (range and time delays). Other effects, such as range rate errors, appearance angle deviation, defocusing loss on Mars, etc. are also needed to be estimated. Ice depolarization effects due to Martian clouds on radio waves is unknown yet, which is expected to be small, because lower optical depth and thinner layer of cloud: Total Martian atmospheric gaseous attenuation is expected to be less than 1 dB on microwaves band, because the Martian atmosphere has very low concentration in uncondensed H2O and O2. An accurate calculation for zenith opacity requires the information about scale heights of H2O and O2 distribution. An accurate water vapor altitude profile at Mars is not available yet. Under the normal condition, CO2 and N2 gases do not have electric or magnetic dipoles and do not absorb electromagnetic energy from the waves. However, they may generate the dipoles through a collision and interact with waves under a high density condition and absorb electromagnetic waves in the infrared and visible band. Dust storm is most dominant factor to the radio wave attenuation. Large Martian dust storm can cause at least 3 dB or higher loss to Ka band wave. For a normal dust storm, the attenuation is about 1 dB. The attenuation much depends on dust mass loading, dust size distribution, etc. Most large dust storm occur in the southern hemisphere during later spring and early summer when the southern hemisphere become suddenly hot.

Ho, Christian↗

Modeling the Interaction Between Energy Efficiency and Demand Response on Regional Grid Scales: Preprint

With increasing penetration of intermittent renewable generation at grid and distributed scales, flexible building loads can provide significant system value and support the evolving needs of the grid. The growing value of load flexibility may complicate the traditional separation between energy efficiency (EE) and demand response (DR). EE measures may compete in some cases with a building’s DR capabilities but complement one another in other cases. EE can also increase or decrease the need for DR at the system level and change the availability of DR to meet system needs. In this study we present a bottom-up approach to modeling interactive effects between EE and DR in buildings within two regions of the US electricity grid. From a library of building simulation models for different buildings and climates, we synthesize system-level demand profiles and the impacts of potential future EE portfolios. Coupling the underlying building models with a database of DR-enabling technologies, we then compute the quantity of DR that can be delivered in each scenario. The results show that EE and DR interactions are largely driven by the timing of EE savings that are measure-specific and the coincidence with system peak demand that is region-specific. We also find that perspective of the impacts matters – for instance that some EE measures reduce the system need for DR but also reduce the DR potential. Our results imply that utility EE and DR programs developed without considering interactive effects may lead to increased grid-management challenges over the long term.

buildings↗

EVI-EnSitePy (Electric Vehicle Infrastructure – Energy Estimation and Site Optimization Tool in Python) [EVI-X Modeling Suite] [SWR-25-07]

EVI-EnSitePy is a comprehensive agent-based tool designed for the analysis and design of high-power charging sites, encompassing a wide array of site agents including Electric Vehicles (EVs), chargers, energy storage units (ESS), renewable energy resources (DER), and loads. This versatile tool offers diverse functionalities and a modular modeling approach, allowing detailed configuration of agents based on power ratings, port numbers, energy capacities, demand requirements, charger interfaces, and flexibility to customize the tool for project specific goals. By simulating agent interactions and employing various metrics, EVI-EnSitePy enables the assessment of site performance, exploration of energy management systems (EMS), and implementation of innovative EV charging policies. Utilizing EV charge schedules and arrival states, the tool performs thorough charging site simulations, with outputs consisting of agent and site-level power profiles and statistical metrics. Employing a tree graph structure, EVI-EnSitePy supports nested site structures and power distribution modeling. The tool's ability to generate charging schedules deterministically or via stochastic analysis further enhances its versatility. Through its features and capabilities, EVI-EnSitePy offers a powerful platform for informed decision-making in the realm of high-power charging site design and operation.

Jackson, Derek [National Renewable Energy Laborato↗

Highlights of Part I: Propagation Through Mars Environment: Propagation through Mars Environment - Part 1

We recommend using the dayside Martian ionosphere as a reflector for global communication, because it has a stable density peak and usable critical frequency. This is very crucial for the future Mars ground to ground communication. The dayside ionosphere has been well modeled as a Chapman layer. We suggest performing the Martian nightside ionosphere modeling study. Because the nightside ionosphere has very little measurements available, we propose to drop a digital ionosound instrument into the Mars surface for data collection. Even though the Martian tropospheric radio refractivity had a small value, it still can cause ray bending and multipath effects. We recommend performing an accurate calculation on excess phase and group delays (range and time delays). Other effects, such as range rate errors, appearance angle deviation, defocusing loss on Mars, etc. should be estimated. Ice depolarization effects due to Martian clouds on radio waves are unknown yet, but they are expected to be small, because of lower optical depth and the thinner layer of cloud. Total Martian atmospheric gaseous attenuation is expected to be less than 1 dB on microwaves and, because the Martian atmosphere had very low concentration in uncondensed H2O and O2. An accurate calculation for zenith opacity requires the information about scale heights of H2O and O2 distribution. An accurate water vapor altitude profile at Mars is not available et. Under the normal condition, CO2 and N2 gases ddo not have electric or magnetic dipoles and do not absorb electromagnetic energy from the waves. However, they may generate the dipoles through a collision and interact with waves under a high density condition and absorb electromagnetic waves in the infrared and visible band. Dust storm is the most dominant factor on the radio wave attenuation. Large Martian dust storms can cause at least 3 dB or higher loss to Ka band wave. For a normal dust storm, the attenuation is about 1 dB. The attenuation much depends on dust mass loading, dust size distribution, etc. Most large dust storms occur in the southern hemisphere during later spring and early summer when the southern hemisphere becomes suddenly hot.

Ho, Christian↗

Methods for Representing Flexible, Energy-Constrained Technologies in Utility Planning Tools

Capacity expansion models are widely used by power system researchers, planners, and policy analysts to evaluate alternative power system investment scenarios. With the increasing deployment of wind and solar in the US, there has been much focus on improving the representations of variable generation (VG) technologies within capacity expansion models. Models that capture the variable net-load profiles and larger reserve requirements associated with high penetration VG systems represent an improvement to classic capacity expansion models, but fall short of capturing the complexities associated with storage technologies, such as battery energy storage (BES) and concentrating solar power with thermal energy storage (CSP with TES). While difficult to model in a capacity expansion setting, these technologies are potentially competitive sources of flexibility with the intriguing characteristics of being able to absorb VG that would otherwise be curtailed and directly contribute to renewable energy goals, respectively. In this paper we present methods for accurately representing these technologies in a large-scale capacity expansion model with high electrical and geospatial resolution. VG modeling techniques, including novel methods for capturing curtailment due to unit commitment and other hourly dispatch phenomena, are also reviewed. Modeling for a region in the southwestern United States demonstrates the economic relevance of being able to explicitly trade off the costs and capabilities of energy-constrained technologies, especially BES, against other resources in the near-term, in time to make plans for the coming decade

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cabin Thermal Management Analysis for SuperTruck II Next-Generation Hybrid Electric Truck Design

In this article, we present a multistage, coupled thermal management simulation approach, informed by physical testing where available, to aid design decisions for PACCAR's SuperTruck II hybrid truck cabin concept. Focus areas include cabin insulation, battery sizing, and sleeper curtain position, as well as heating, ventilating, and air-conditioning (HVAC) component and accessory configurations, to maintain or improve thermal comfort while saving energy. The authors analyzed weather data and determined the national vehicle miles traveled weighted temperature and solar conditions for long-haul trucks. Example weather day profiles were selected to approximate the 5th and 95th percentile weighted conditions. A daylong drive cycle was developed to impose appropriate external wind conditions during rest and driving periods. Using the National Renewable Energy Laboratory's vehicle HVAC modeling and simulation tool VTCab, HVAC load design trade-off studies for the new truck geometry concept were completed. Parameters analyzed included effects of paint color, insulation, glass transmissivity, and curtain location. Simulation results helped with early design material selections for efficient cabin climate control. A detailed three-dimensional computer-aided engineering (CAE), computational fluid dynamics (CFD), radiation, and human physiology co-simulation, referred to in this article as CAE Thermal-CFD, was used to evaluate thermal comfort and energy impacts of diffuser configurations and air supply settings in driving and hoteling modes. Analysis revealed that it is more difficult to heat the cabin in hoteling mode during the winter than to cool the space in the summer. This seasonal load profile drives the requirement of additional energy storage for heating comfort. To determine the battery capacity requirement, multiday HVAC operation drive cycle simulations were then completed, showing that a 15-kWh battery would be required for HVAC operation during hoteling. Results helped reduce cabin thermal loads, determine component sizing requirements, and improve occupant comfort to save fuel and contribute to the economic viability of the hybrid system.

33 ADVANCED PROPULSION SYSTEMS↗

A Siamese CNN + KNN-Based Classification Framework for Non-intrusive Load Monitoring

Through the development of smart grids, programs such as demand side response, have been presented as auxiliary services to the real-time operation of distributed networks. In order to provide consumers information on their energy consumption, so that a modulation in consumption is possible, non-intrusive load monitoring has been introduced as an solution to this pattern recognition problem. Non-intrusive load monitoring enables the modeling of electrical loads connected to the low-voltage system, considering only a single measurement point. Presented state-of-the-art solutions though, consider availability of data as well as representation of all possible classes of the environment. This is of course a most conservative hypothesis, since in real-life applications availability of such data is much difficult, as well as the dynamic behavior of models is implicitly evolving in time. Here, a framework that uses neural Siamese networks with k-nearest neighbor clustering is presented toward non-intrusive load monitoring. Online learning feature is implemented, which relaxes the hypothesis of data requirements as well addresses the evolving nature of load profile. k-nearest clustering allows nonlinear characteristic space modelling. Test results using synthetics and real-life data show that the solution, besides obtaining a good generalizability in the classification, also obtained results with an accuracy of 95.77%.

24 POWER TRANSMISSION AND DISTRIBUTION↗