Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic programming”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Cluster Dynamics Modeling Needs for the Advanced Materials and Manufacturing Technologies Program

This milestone report aims to identify and assess the cluster dynamics (CD) modeling requirements within the Department of Energy's Office of Nuclear Energy (DOE-NE) Advanced Materials and Manufacturing Technologies (AMMT) program and to communicate these needs to the DOE-NE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. The goal is to ensure NEAMS is well-informed about the CD modeling requirements to support AMMT's mission of accelerating the development, qualification, demonstration, and deployment of advanced structural materials and manufacturing for nuclear energy applications. CD modeling is an essential tool for predicting the degradation of structural materials under irradiation, which is a key component of AMMT's accelerated qualification process. The AMMT program focuses on both additively manufactured and wrought structural alloys, such as laser powder-bed fusion 316H austenitic stainless steel, alloy 709, Haynes 244, and alloy 617. These materials require a generalized CD modeling framework to facilitate rapid model development and computational simulation. A flexible, generalized CD software, similar to the Multiphysics Object-Oriented Simulation Environment (MOOSE) finite element framework, would enable modeling of various cluster types, including defect clusters, defect-solute clusters, and multicomponent clusters, incorporating thermodynamics and kinetics parameters. Radiation effects, microstructural feature evolution, and multi-dimensional modeling are critical considerations for the CD model. The usability of the CD code should allow for easy modification and coupling with MOOSE-based simulations. Additionally, the software should adhere to Nuclear Quality Assurance-1 standards, include a testing suite for verification and validation, and be version-controlled within a national laboratory-managed Git repository. Benchmark problems are needed to assess code predictions and performance.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Finite Element Analysis of the TRUST Nonlinear Dynamics Testbed

This paper builds on prior work conducted within the Los Alamos National Laboratory (LANL) Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) program. Specifically, it builds on finite element (FE) modeling efforts for the TRUST program’s Nonlinear Dynamics (ND) testbed. Historically, the FE model for the ND testbed has exclusively utilized a Lanczos eigensolver that linearly extracts the system’s natural frequencies. This paper investigates the Abaqus 2024’s explicit dynamic solver, which implements a central difference explicit solver. The central difference method used in Abaqus can capture nonlinear material responses in structural dynamic simulations making it suitable for the ND FE model.

42 ENGINEERING↗

Software classification using phylogenetic techniques

Software, such as malware, may be classified using phylogenetic techniques. An evolutionary history of a representative set of software programs may be reconstructed to generate a reference phylogeny. Dynamic traces of the representative software programs may be obtained. The dynamic traces may include time-ordered sequences of execution commands extracted from running software binaries. Metrics may be developed using the dynamic traces. One or more unknown software programs may then be classified against the reference phylogeny using the metrics developed using the dynamic traces of the representative set of software programs.

97 MATHEMATICS AND COMPUTING↗

An Atlas of Current Customer-Facing Utility Program Designs and Pricing

The National Renewable Energy Laboratory (NREL) and Kevala conducted a targeted literature review and leveraged extensive expertise, including team members with four decades of experience in the utility sector, to characterize utility programs and rate designs. This analysis delves into the motivations behind these programs and the various hurdles they face. Through this in-depth study, the team provides critical insights into the operational dynamics of utility programs, identifying key drivers and barriers that influence their effectiveness and implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Applying Quantum Computing to Simulate Power System Dynamics

Power system dynamics are generally modeled by high dimensional nonlinear differential-algebraic equations due to a large number of generators, loads, and transmission lines. Thus, its computational complexity grows exponentially with the system size. This paper demonstrates the potential use of quantum computing algorithms to model the power system dynamics. Leveraging a symbolic programming framework, we equivalently convert the power system dynamics’ differential algebraic equations (DAEs) into ordinary differential equations (ODEs), where the data of the state vector can be encoded into quantum computers via amplitude encoding. The system's nonlinearity is captured by Taylor polynomial expansion, the quantum state tensor, and Hamiltonian simulation, whereas state variables can be updated by a quantum linear equation solver. Our results show that quantum computing can simulate the dynamics of the power system with high accuracy, whereas its complexity is polynomial in the logarithm of the system dimension. Our work also illustrates the use of scientific machine learning tools for implementing scientific computing concepts, e.g., Taylor expansion, DAEs/ODEs transform, and quantum computing solver, in the field of power engineering.

Tran, Huynh↗

Dynamically morphing microchannels in liquid crystal elastomer coatings containing disclinations

Liquid crystal elastomers (LCEs) hold a major promise as a versatile material platform for smart soft coatings, since their orientational order can be predesigned to program a desired dynamic profile. In this work, we introduce temperature-responsive dynamic coatings based on LCEs with arrays of singular defects-disclinations that run parallel to the surface. The disclinations form in response to antagonistic patterns of the molecular orientation at the top and bottom surfaces, imposed by the plasmonic mask photoalignment. Upon heating, an initially flat LCE coating develops linear microchannels located above each disclination. The stimulus that causes a non-flat profile of LCE coatings upon heating is the activation force induced by the gradients of molecular orientation around disclinations. To describe the formation of microchannels and their thermal response, we adopt a Frank-Oseen model of disclinations in patterned director field and propose a linear elasticity theory to connect the complex spatially-varying molecular orientation to the displacements of the LCE. The thermo-responsive surface profiles predicted by the theory and by the finite element modeling are in good agreement with the experimental data; in particular, higher gradients of molecular orientation produce a stronger modulation of the coating profile. The elastic theory and the finite element simulations allow us to estimate the material parameter that characterizes the elastomer coating’s response to the thermal activation. The disclinations containing LCEs show potential as soft dynamic coatings with a predesigned responsive surface profile.

36 MATERIALS SCIENCE↗

Dynamic Risk-Aware Patch Scheduling

A program that defines and assesses the dynamic risk of software vulnerabilities and considers the dynamic risks into patch scheduling to reduce security risks posed by vulner­abilities and provide formal guidance to security operations at various organizations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Community Solar for All: Key Findings for State Energy Offices and State LIHEAP Agencies from the Inclusive Shared Solar Initiative

Despite the significant potential for community solar to reduce energy burdens and costs, it has largely remained out of reach for low-income households. While the U.S. community solar market has grown considerably over the last decade, as of December 2022 low to moderate-income (LMI) community solar represented just 2% of the overall market. Effective community solar policies and program decisions can help address this dynamic. State laws, policies, and program rules are critical to the development of community solar programs and projects that are affordable for and cater to the needs of LMI utility customers, who often face disproportionately high energy costs relative to their incomes. This report explores how two sets of state agencies in particular — State and Territory Energy Offices and State Low Income Home Energy Assistance Program (LIHEAP) Agencies —can help to streamline and prioritize the delivery of affordable and accessible shared solar. State Energy Offices are often involved in community solar policy and program design from inception, whether by supporting the enactment of enabling legislation or informing the development of program rules and regulations. State Energy Offices may also be charged with administering or overseeing the implementation of statewide community solar programs and, through the U.S. State Energy Program and other sources of funding, can provide resources and loans that enhance community, developer, and utility confidence and capacity to build, host, and derive value from projects. Relatedly, as implementers of federal LIHEAP block grants, State LIHEAP Agencies have a deep understanding of the needs of lower-income households and can help inform the design and delivery of community solar programs.

14 SOLAR ENERGY↗

The fourth decade of underground research at the Grimsel Test Site - what we have learned and where we go from here - 15075

At the Grimsel Test Site, NAGRA and its partners have celebrated thirty years' worth of essential contributions to the characterization of crystalline host rock, and the development and confirmation of safe geological disposal concepts. In operation since 1984, the underground research laboratory in the Swiss Alps shall not accept radioactive waste but can host experiments with radiotracers/radionuclides under strictly controlled conditions. The strong drive for international cooperation at the Grimsel Test Site is reflected in the more than two dozen organizations and research institutes from twelve countries and the European Union which have participated in the research program to date. The program has been designed dynamically to always mirror the current requirements of national programs for the long-term management of radioactive waste, as well as attempt to anticipate the next steps. Early work featured the development of methodologies for formation characterization. Then followed a period concentrating on performance assessment issues, before radionuclide migration and barriers were investigated intensely. The past 15 years have been dominated by engineering demonstration experiments. The research conducted at the Grimsel Test Site has complemented laboratory experiments, surface investigations and numerical modelling studies through the bridging of different scales and drawing off links between laboratory setups and natural analogues. The crystalline rock formations of the Aar Massif have provided an opportunity to do experiments in environments similar to those of future repositories. The facility also serves as a platform for continual knowledge transfer between generations of scientists and fosters synergies among disciplines. However, considering the ambitious schedule for repository implementation in several continuous, one may ask whether the era of generic underground rock laboratories is approaching its end. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ESnet Requirements Review Program Through the IRI Lens: A Meta-Analysis of Workflow Patterns Across DOE Office of Science Programs (Final Report)

The Department of Energy (DOE) ensures America’s security and prosperity by addressing its energy, environmental, and nuclear challenges through transformative science and technology solutions. The DOE’s Office of Science (SC) delivers groundbreaking scientific discoveries and major scientific tools that transform our understanding of nature and advance the energy, economic, and national security of the United States. The SC’s programs advance DOE mission science across a wide range of disciplines and have developed the research infrastructure needed to remain at the forefront of scientific discovery. The DOE SC’s world-class research infrastructure — exemplified by the 28 SC scientific user facilities — provides the research community with premier observational, experimental, computational, and network capabilities. Each user facility is designed to provide unique capabilities to advance core DOE mission science for its sponsor SC program and to stimulate a rich discovery and innovation ecosystem. Research communities gather and flourish around each user facility, bringing together diverse perspectives. A hallmark of many facilities is the large population of students, postdoctoral researchers, and early-career scientists who contribute as full-fledged users. These facility staff and users collaborate over years to devise new approaches to utilizing the user facility’s core capabilities. The history of the SC user facilities has many examples of wildly inventive researchers challenging operational orthodoxy to pioneer new vistas of discovery; for example, the use of the synchrotron X-ray light sources for study of proteins and other large biological molecules. This continual reinvention of the practice of science — as users and staff forge novel approaches expressed in research workflows — unlocks new discoveries and propels scientific progress. Within this research ecosystem, the high-performance computing (HPC) and networking user facilities stewarded by SC’s Advanced Scientific Computing Research (ASCR) program play a dynamic cross-cutting role, enabling complex workflows demanding high performance data, networking, and computing solutions. The DOE SC’s three HPC user facilities and the Energy Sciences Network (ESnet) high-performance research network serve all of the SC’s programs as well as the global research community. Argonne Leadership Computing Facility (ALCF), the National Energy Research Scientific Computing Center (NERSC), and Oak Ridge Leadership Computing Facility (OLCF) conceive, build, and provide access to a range of supercomputing, advanced computing, and large-scale data-infrastructure platforms, while ESnet interconnects DOE SC research infrastructure and enables seamless exchange of scientific data. All four facilities operate testbeds to expand the frontiers of computing and networking research. Together, the ASCR facilities enterprise seeks to understand and meet the needs and requirements across SC and DOE domain science programs and priority efforts, highlighted by the formal requirements reviews (RRs) methodology. In recent years, the research communities around the SC user facilities have begun experimenting with and demanding solutions integrated with HPC and data infrastructure. This rise of integrated-science approaches is documented in many community and high-level government reports. At the dawn of the era of exascale science and the acceleration of artificial intelligence (AI) innovation, there is a broad need for integrated computational, data, and networking solutions. In response to these drivers, DOE has developed a vision for an Integrated Research Infrastructure (IRI): To empower researchers to meld DOE’s world-class research tools, infrastructure, and user facilities seamlessly and securely in novel ways to radically accelerate discovery and innovation.

42 ENGINEERING↗

Improving Dose Modeling With Dynamic Modeling Tools [Slides]

Utilities aiming for higher fuel enrichment for power uprates or extended operation times before refueling must conduct a new dose analysis. Current conservative dose estimation standards may cause utilities to exceed regulatory limits for proposed increased fuel enrichment. A more accurate modeling of doses from reactor accidents can lower these conservative assumptions. Prescott et al. (2022) demonstrated that the Event Modeling Risk Assessment using Linked Diagrams (EMRALD) software tool, developed at Idaho National Laboratory (INL), can be coupled with the Modular Accident Analysis Program (MAAP5) for dynamic accident analysis in reactor plants. EMRALD forms models of potential accident scenarios, while MAAP5 simulates the accident progression and dose consequences. By integrating these software tools with utility-specific data, a more precise estimation of dose consequences from plant accidents can be achieved. Preliminary findings indicate that EMRALD provides accurate mean core damage frequencies for generalized accident scenarios. Future work includes expanding the model to account for plant-specific data and mitigation factors.

97 - MATHEMATICS AND COMPUTING↗

Ushering in the New Age of Laboratories: Smart Labs in Practice; Preprint

Ventilation is the first line of defense against airborne hazards produced during research activities in laboratories. A vital component to maintaining healthy, safe, indoor air quality, laboratory ventilation systems are often victim to ineffective operation, posing a risk to an organization's most important asset - the researchers. Furthermore, system inefficiencies can lead to up to 50% wasted energy. By providing a framework to improve the safety and energy efficiency through optimized ventilation and operations, the Smart Labs Toolkit guides laboratory stakeholders through a straight-forward, holistic approach to achieving a dynamic Smart Labs program. A Smart Labs program employs a combination of physical, administrative, and management techniques to plan, assess, optimize, and manage high-performance laboratories. Grounded in the Smart Labs methodology, the National Renewable Energy Laboratory (NREL) implemented a successful Smart Labs program to oversee the design, construction, maintenance, and operations of its laboratories. To accomplish this effort, NREL's key stakeholders created an internal partnership to align NREL's existing laboratories with Smart Labs principles and solidify organizational roles for the safe and efficient operation of laboratory assets. The program provides the groundwork for decarbonization strategies centered around building operation. This paper outlines best practices employed by NREL to develop a cross-cutting Smart Labs team, garner managerial support, and effectively communicate of goals around safety and energy. Strategies include specific Smart Labs best practices, such as implementing a Laboratory Ventilation Risk Assessment - a systematic process for identifying risk due to airborne hazards and informing dynamic, demand-based ventilation to optimize safety and efficiency.

decarbonization↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

NESSi : The N on- E quilibrium S ystems S imulation package

The nonequilibrium dynamics of correlated many-particle systems is of interest in connection with pump–probe experiments on molecular systems and solids, as well as theoretical investigations of transport properties and relaxation processes. Nonequilibrium Green’s functions are a powerful tool to study interaction effects in quantum many-particle systems out of equilibrium, and to extract physically relevant information for the interpretation of experiments. Here, we present the open-source software package NESSi (The Non-Equilibrium Systems Simulation package) which allows to perform many-body dynamics simulations based on Green’s functions on the L-shaped Kadanoff–Baym contour. NESSi contains the library libcntr which implements tools for basic operations on these nonequilibrium Green’s functions, for constructing Feynman diagrams, and for the solution of integral and integro-differential equations involving contour Green’s functions. The library employs a discretization of the Kadanoff–Baym contour into time points and a high-order implementation of integration routines. The total integrated error scales up to $\mathcal{O}(N^{-7})$, which is important since the numerical effort increases at least cubically with the simulation time. A distributed-memory parallelization over reciprocal space allows large-scale simulations of lattice systems. We provide a collection of example programs ranging from dynamics in simple two-level systems to problems relevant in contemporary condensed matter physics, including Hubbard clusters and Hubbard or Holstein lattice models. The libcntr library is the basis of a follow-up software package for nonequilibrium dynamical mean-field theory calculations based on strong-coupling perturbative impurity solvers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗