Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “durable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Development of Fixtures and Methods to Assess the Durability of Balance of Systems Components

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were, therefore, examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using a benchtop prototype fixture to identify the most influential environmental stressors on BoS components as well as the effect of external mechanical perturbation. The prototype fixture was used to develop a perturbation capability for future use in the combined-accelerated stress testing chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 °C from ~40 °C) and a different failure mode (arcing at the metal pins rather than overheating of the fuse filament) were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (measured for static specimens, with failure occurring in the fuses) to 15 A (for tests with mechanical perturbation, with failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy). Chemical composition analysis included energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

14 SOLAR ENERGY↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 degrees C from ~40 degrees C) and a different failure mode were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy).

balance of systems↗

Achieving 5,000-h and 8,000-h Low-PGM Electrode Durability on Automotive Drive Cycles

Whereas total Pt loading in anode and cathode catalysts below 0.125 mg cm −2 is required to meet the stringent cost target for automotive fuel cell systems (FCS) for light duty vehicles, low-loaded cathode catalysts are susceptible to unacceptable aging-related performance losses at high current densities. A framework model, validated by accelerated stress test data, has identified cell voltage, relative humidity (RH) and temperature as the key operating variables that affect degradation of a high-activity d-PtCo/C cathode catalyst with 0.1 mg cm −2 Pt loading. Drive cycle simulations indicate that these can be controlled by properly selecting the minimum FCS power, compressor-expander module (CEM) turndown, and stack coolant temperature. The optimum system parameters are 4-kW e minimum power for an 80-kW e FCS, CEM turndown of 12.5, and 66 °C average coolant exit temperature that combine to limit the maximum cell voltage to 850 mV and outlet RH to 90%–100%. Depending on Pt loading, the mismatch between actual and allowable degradation for 10% power loss over 5,000-h lifetime requires the stack to be oversized by 2.4%–5%, resulting in 8.4%–41% lower Pt utilization and 7.1%–20.5% penalty in stack cost. The corresponding results for 8,000-h lifetime are 10.3%-14% stack oversizing, 23%–51.8% lower Pt utilization, and 24.1%–35.4% stack cost penalty.

08 HYDROGEN↗

Impact of Carbon Support Structure on the Durability of PtCo Electrocatalysts

High performing, low-Pt content fuel cell membrane electrode assemblies (MEAs) are critical to the economic viability of proton exchange membrane fuel cells (PEMFCs) for the transportation industry. Considerable research has been conducted to reduce the Pt content in fuel cells, leading to the development of transition metal alloys, such as Platinum-Cobalt (PtCo). The degree of degradation of PtCo catalysts can be impacted by not only the composition and morphology of the catalyst particle itself, but also its interactions with the carbon support. In this study several low-PtCo MEAs were fabricated, with various combinations of porous and solid carbon cathode catalyst supports. The MEAs were subjected to an accelerated stress test (AST), and the catalyst degradation characterized using electrochemical, X-ray scattering, and electron microscopy techniques. Porous supports retain more of their electrochemically-active surface area (ECSA) and demonstrate higher performance after the AST. This is believed to be due to the ability of the porous supports to trap the metal particles within the pores, slowing their dissolution/precipitation, and agglomeration. However porous supports also exhibit greater increases in transport resistance probably associated with enhanced Co leaching under the AST conditions.

25 ENERGY STORAGE↗

Do Melamine and Melamine-Formaldehyde Surface Modifiers Improve Fuel Cell Activity and Durability?

Precious group metal-based catalysts based on Pt- and Pt-alloys are currently used as catalysts for the kinetically sluggish Oxygen Reduction Reaction (ORR) on the cathode of fuel cells. The activity of Pt or Pt-alloy catalysts towards ORR is severely compromised by the adsorption of spectator-species such as sulfonate anions from perfluorosulfonic acid (PFSA) ionomer or Pt-O(H) ad via water activation. Considering recent evidence pointing to the improvement in ORR activity via the use of melamine organic molecule or melamine-formaldehyde copolymeric additives as surface blocking agents for the prevention of sulfonate or Pt-OH ad adsorption, we evaluated these additives in fuel cells. The catalysts were modified with either of these additives and characterized using ex situ and in situ methods to verify successful adsorption and eventual performance in fuel cells. These surface modifying agents were found to suppress Pt-OH ad formation as well as suppress ORR activity. There was no evidence to point out that these additives improved ORR activity and H 2 /air polarization performance in a fuel cell MEA on supported, polycrystalline Pt catalyst.

08 HYDROGEN↗

Glass/Glass Focus Group: Module Technology and Durability Roadmap

The G/G Focus Group was created one year ago with a mission to identify critical research directions in G/G packaging and how research in DuraMAT 2.0 can drive this area forward. This is a summary of the research on Glass/Glass modules discussed over the past year.

CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS,E↗

Evaluating the Durability of Balance of Systems Components Using C-AST

The testing of branch- and cable-connectors, and fuses in C-AST is introduced. A significant effect was observed when mechanical actuation was introduced to the benchtop prototype testing. Therefore, this presentation emphasizes the mechanical test fixture, data acquisition system, failure analysis of the components used in specimen assemblies, and the validation of the results relative to field failed samples.

components↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for C-AST. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed immediately once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure occurring in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy). Chemical composition analysis included: energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing: Preprint

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy).

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Previous papers and presentations have focused on the development of the test method using a benchtop prototype. This presentation covers the early results of C-AST aging of static and dynamic specimens.

balance of systems↗

Chapter 3: Reliability and Durability Testing Today

In year 2022 the Institute of Applied Sustainability to the Built Environment (ISAAC) of the Department of Environment Constructions and Design (DACD) of the University of Applied Sciences and Arts of Southern Switzerland (SUPSI) celebrates an important anniversary: 40 years of Ticino Solare (TISO), the first photovoltaic system in Europe connected to the grid back in 1982. The Institute of Applied Sustainability to the Built Environment (ISAAC) intends to realize a commemorative/perspective publication on the TISO. The publication will be available starting from the beginning of September 2022 and will be distributed on the occasion of the WCPEC in Milan (26-30 September 2022) and then be available for online download at https://pvlab.solar/wp-content/uploads/2022/10/TISO_Catalogo_Web.pdf.

durability↗

A Synthetic Hydrogel Composite with the Mechanical Behavior and Durability of Cartilage

Here, we report the first hydrogel with the strength and modulus of cartilage in both tension and compression, and the first to exhibit cartilage-equivalent tensile fatigue strength at 100 000 cycles. These properties are achieved by infiltrating a bacterial cellulose (BC) nanofiber network with a poly(vinyl alcohol) (PVA)–poly(2-acrylamido-2-methyl-1-propanesulfonic acid sodium salt) (PAMPS) double network hydrogel. The BC provides tensile strength in a manner analogous to collagen in cartilage, while the PAMPS provides a fixed negative charge and osmotic restoring force similar to the role of aggrecan in cartilage. The hydrogel has the same aggregate modulus and permeability as cartilage, resulting in the same time-dependent deformation under confined compression. The hydrogel is not cytotoxic, has a coefficient of friction 45% lower than cartilage, and is 4.4 times more wear-resistant than a PVA hydrogel. The properties of this hydrogel make it an excellent candidate material for replacement of damaged cartilage.

36 MATERIALS SCIENCE↗

Phloroglucinol–2,6‐Diaminoanthraquinone as a Durable Redox Mediator for Enhancing Conversion Reaction Kinetics in Lithium‐Sulfur Batteries

Abstract Lithium‐sulfur batteries, despite being a promising solution for next‐generation secondary batteries, require substantial efforts to overcome the challenges of sluggish sulfur redox kinetics, polysulfides shuttling, and Li metal instability before achieving practical viability. Conventional strategies that utilize metal catalysts or soluble redox mediators (RMs) are limited by either impractical producing processes or unsatisfactory service life. Herein, an electrochemically active organic material, phloroglucinol – 2,6‐diaminoanthraquinone (PG‐DAAQ) is synthesized through a green and facile polymerization process to better resolve these issues. Serving as an RM at the cathode, PG‐DAAQ exhibits enduring redox activity within the sulfur operating potential window, leading to enhanced redox kinetics and sulfur utilization. Remarkably, even without any metal elements, PG‐DAAQ exhibits an excellent affinity to polysulfides, thereby suppressing the shuttling and facilitating the formation of a more favorable solid‐electrolyte interface to stabilize Li deposition at the anode. As a result, Li‐S cells employing PG‐DAAQ show significantly enhanced cycling and rate performances than the control cells. Even with a low electrolyte‐to‐sulfur ratio of 6, pouch cells with PG‐DAAQ deliver a reversible discharge capacity of 821 mA h g −1 after 100 cycles at a C/10 rate.

Lai, Tianxing↗

An Ultrafast, Durable, and High-Loading Polymer Anode for Aqueous Zinc-Ion Batteries and Supercapacitors

Zn metal has shown promise as an anode material for grid-level energy storage, yet is challenged by dendritic growth and low Coulombic efficiency. Herein, an ultrafast, stable, and high-loading polymer anode for aqueous Zn-ion batteries and capacitors (ZIBs and ZICs) is developed by engineering both the electrode and electrolyte. The anode polymer is rationally prepared to have a suitable electronic structure and a large pi-conjugated structure, whereas the electrolyte is manufactured based on the superiority of triflate anions over sulfate anions, as analyzed and confirmed via experiments and simulations. This dual engineering results in an optimal polymer anode with a low discharge potential, near-theoretical capacity, ultrahigh-loading capability (approximate to 50 mg cm -2 ), ultrafast rate (100 A g -1 ), and ultralong lifespan (one million cycles). Further, its mechanism involves reversible Zn 2+ /proton co-storage at the carbonyl site. When the polymer anode is coupled with cathodes for both ZIB and ZIC applications, the devices demonstrate ultrahigh power densities and ultralong lifespans, far surpassing those of corresponding Zn-metal-based devices.

25 ENERGY STORAGE↗