Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dual imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Dual-Telescope Multi-Channel Thermal-Infrared Radiometer for Outer Planet Fly-By Missions

The design of a versatile dual-telescope thermal-infrared radiometer spanning the spectral wavelength range 8-200 microns, in five spectral pass bands, for outer planet fly-by missions is described. The dual- telescope design switches between a narrow-field-of-view and a wide-field-of-view to provide optimal spatial resolution images within a range of spacecraft encounters to the target. The switchable dual-field- of-view system uses an optical configuration based on the axial rotation of a source-select mirror along the optical axis. The optical design, spectral performance, radiometric accuracy, and retrieval estimates of the instrument are discussed. This is followed by an assessment of the surface coverage performance at various spatial resolutions by using the planned NASA Europa Mission 13-F7 fly-by trajectories as a case study.

Aslam, Shahid↗

Infrared sensors and systems for enhanced vision/autonomous landing applications

There exists a large body of data spanning more than two decades, regarding the ability of infrared imagers to 'see' through fog, i.e., in Category III weather conditions. Much of this data is anecdotal, highly specialized, and/or proprietary. In order to determine the efficacy and cost effectiveness of these sensors under a variety of climatic/weather conditions, there is a need for systematic data spanning a significant range of slant-path scenarios. These data should include simultaneous video recordings at visible, midwave (3-5 microns), and longwave (8-12 microns) wavelengths, with airborne weather pods that include the capability of determining the fog droplet size distributions. Existing data tend to show that infrared is more effective than would be expected from analysis and modeling. It is particularly more effective for inland (radiation) fog as compared to coastal (advection) fog, although both of these archetypes are oversimplifications. In addition, as would be expected from droplet size vs wavelength considerations, longwave outperforms midwave, in many cases by very substantial margins. Longwave also benefits from the higher level of available thermal energy at ambient temperatures. The principal attraction of midwave sensors is that staring focal plane technology is available at attractive cost-performance levels. However, longwave technology such as that developed at FLIR Systems, Inc. (FSI), has achieved high performance in small, economical, reliable imagers utilizing serial-parallel scanning techniques. In addition, FSI has developed dual-waveband systems particularly suited for enhanced vision flight testing. These systems include a substantial, embedded processing capability which can perform video-rate image enhancement and multisensor fusion. This is achieved with proprietary algorithms and includes such operations as real-time histograms, convolutions, and fast Fourier transforms.

Kerr, J. Richard↗

Automated detection of double nuclei galaxies using GOTHIC and the discovery of a large sample of dual AGN

We present a novel algorithm to detect double nuclei galaxies (DNG) called Gothic (Graph-bOosTed iterated HIll Climbing) – that detects whether a given image of a galaxy has two or more closely separated nuclei. Our aim is to test for the presence of dual/multiple active galactic nuclei (AGN) in galaxies that visually represent a DNG. Although galaxy mergers are common, the detection of dual AGN is rare. Their detection is very important as they help us understand the formation of supermassive black hole (SMBH) binaries, SMBH growth and AGN feedback effects in multiple nuclei systems. There is thus a need for an algorithm to do a systematic survey of existing imaging data for the discovery of DNGs and dual AGNs. We have tested Gothic on an established sample of DNGs with a 100 per cent detection rate and subsequently conducted a blind search of 1 million SDSS DR16 galaxies (with spectroscopic data available) lying in the redshift range of z = 0 to 0.75. From the list of candidate DNGs found, we have detected 159 dual AGNs, of which 2 are triple AGN systems. Our results show that dual AGNs are not common, and triple AGN even rarer. The colour (u–r) magnitude plots of the DNGs indicate that star formation is quenched as the nuclei come closer and as the AGN fraction increases. The quenching is especially prominent for dual/triple AGN galaxies that lie at the extreme end of the red sequence.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative analysis of defects in silicon. Silicon sheet growth development for the large are silicon sheet task of the low-cost solar array project

One hundred and seventy four silicon sheet samples were analyzed for twin boundary density, dislocation pit density, and grain boundary length. Procedures were developed for the quantitative analysis of the twin boundary and dislocation pit densities using a QTM-720 Quantitative Image Analyzing system. The QTM-720 system was upgraded with the addition of a PDP 11/03 mini-computer with dual floppy disc drive, a digital equipment writer high speed printer, and a field-image feature interface module. Three versions of a computer program that controls the data acquisition and analysis on the QTM-720 were written. Procedures for the chemical polishing and etching were also developed.

Natesh, R.↗

Chip-integrated metasurface full-Stokes polarimetric imaging sensor

Abstract Polarimetric imaging has a wide range of applications for uncovering features invisible to human eyes and conventional imaging sensors. Chip-integrated, fast, cost-effective, and accurate full-Stokes polarimetric imaging sensors are highly desirable in many applications, which, however, remain elusive due to fundamental material limitations. Here we present a chip-integrated Meta surface-based Full-Stokes Polar imetric Im aging sensor (MetaPolarIm) realized by integrating an ultrathin (~600 nm) metasurface polarization filter array (MPFA) onto a visible imaging sensor with CMOS compatible fabrication processes. The MPFA is featured with broadband dielectric-metal hybrid chiral metasurfaces and double-layer nanograting polarizers. This chip-integrated polarimetric imaging sensor enables single-shot full-Stokes imaging (speed limited by the CMOS imager) with the most compact form factor, records high measurement accuracy, dual-color operation (green and red) and a field of view up to 40 degrees. MetaPolarIm holds great promise to enable transformative applications in autonomous vision, industry inspection, space exploration, medical imaging and diagnosis.

47 OTHER INSTRUMENTATION↗

Dual-Sampler Processor Digitizes CCD Output

Circuit for processing output of charge-coupled device (CCD) imager provides increased time for analog-to-digital conversion, thereby reducing bandwidth required for video processing. Instead of one sampleand-hold circuit of conventional processor, improved processor includes two sample-and-hold circuits alternated with each other. Dual-sampler processor operates with lower bandwidth and with timing requirements less stringent than those of single-sample processor.

Salomon, P. M.↗

Optical Design for CETUS a Wide-Field 1.5-m Aperture UV Payload Being Studied for a NASA Probe Class Mission Study

As part of a study funded by NASA headquarters, we are developing a probe-class mission concept called the Cosmic Evolution through UV Spectroscopy (CETUS). CETUS includes a 1.5-m aperture diameter telescope with a large field of view (FOV). CETUS includes three scientific instruments: a far ultraviolet (FUV) and near ultraviolet (NUV) imaging camera (CAM); a NUV multiobject spectrograph (MOS); and a dual-channel point/slit spectrograph (PSS) in the Lyman ultraviolet (LUV), FUV, and NUV spectral regions. The large FOV three-mirror anastigmatic (TMA) optical telescope assembly (OTA) simultaneously feeds the three separate scientific instruments. That is, the instruments view separate portions of the TMA image plane, enabling parallel operation by the three instruments. The field viewed by the MOS, whose design is based on an Offner-type spectrographic configuration to provide wide FOV correction, is actively configured to select and isolate numerous field sources using a next-generation micro-shutter array. The two-channel CAM design is also based on an Offner-like configuration. The PSS performs high spectral resolution spectroscopy on unresolved objects over the NUV region with spectral resolving power, R ~ 40,000, in an echelle mode. The PSS also performs long-slit imaging spectroscopy at R ~ 20,000 in the LUV and FUV spectral regions with two aberration-corrected, blazed, holographic gratings used in a Rowland-like configuration. The optical system also includes two fine guidance sensors, and wavefront sensors that sample numerous locations over the full OTA FOV. In-flight wavelength calibration is performed by a wavelength calibration system, and flat-fielding is also performed, both using in-flight calibration sources. We describe the current optical design of CETUS and the major trade studies leading to the design.

space sensors↗

Deep learning enhanced super-resolution x-ray fluorescence microscopy by a dual-branch network

X-ray fluorescence (XRF) microscopy is a powerful technique for quantifying the distribution of elements in complex materials, which makes it a crucial imaging technique across a wide range of disciplines in physical and biological sciences, including chemistry, materials science, microbiology, and geosciences. However, as a scanning microscopy technique, the spatial resolution of XRF imaging is inherently constrained by the x-ray probe profile and scanning step size. Here we propose a dual-branch machine learning (ML) model, which can extract scale-variant features and bypass abundant low-frequency information separately, to enhance the spatial resolution of the XRF images by mitigating the effects of blurring from the probe profile. The model is trained by simulated natural images, and a two-stage training strategy is used to overcome the domain gap between the natural images and experimental data. The tomography reconstruction from enhanced XRF projections shows an improvement in resolution by a scale factor of four and reveals distinct internal features invisible in low-resolution XRF within a battery sample. This study offers a promising approach for obtaining high-resolution XRF imaging from its low-resolution version, paving the way for future investigations in a broader range of disciplines and materials.

36 MATERIALS SCIENCE↗

Imaging Radar Polarimeter

Radar measures full polarization tensor of each element in scene in one sweep. New system comprises dual-polarized antenna, single transmitter, and four-channel receiver and digital recorder installed in aircraft, plus digital processor on ground. Produces radar-backscatter images corresponding to 10- by 10-km regions on ground. Signals recorded from orthogonal linearly polarized antennas combined in computer after flight to synthesize any desired combination of transmitted and received polarizations. Data recorded on single flight processed to provide multiple images.

Zebker, Howard A.↗

The Global LAnd Surface Satellite (GLASS) evapotranspiration product Version 5.0: Algorithm development and preliminary validation

An accurate estimation of spatially and temporally continuous global terrestrial evapotranspiration (ET) is essential in the assessment of surface energy, water and carbon cycles. The Global LAnd Surface Satellite (GLASS) ET product Version 4.0 (v4.0) based on the Bayesian model averaging (BMA) method was generated to estimate global terrestrial ET. However, certain uncertainty for the GLASS ET product v4.0 limits its application. In this study, we introduced the deep neural networks (DNN) merging framework to improve terrestrial ET estimation for GLASS ET product Version 5.0 (v5.0) generation by integrating five satellite-derived ET products [Moderate Resolution Imaging Spectroradiometer (MODIS) ET product (MOD16), Shuttleworth–Wallace dual-source ET product (SW), Priestley–Taylor-based ET product (PT-JPL), modified satellite-based Priestley–Taylor ET product (MS-PT) and simple hybrid ET product (SIM)]. We compared the performance of DNN method against other merging methods, including GLASS ET algorithm v4.0 (BMA), the gradient boosting regression tree (GBRT) method and the random forest (RF) method, based on 195 global eddy covariance (EC) flux towers covering observations from 2000 through 2015. Validations indicated that the DNN had the highest accuracy among four merging methods across different land cover types, yielding the highest average determination coefficients (R 2 , 0.62), root-mean-squared-error (RMSE, 24.1 W/m 2 ) and Kling–Gupta efficiency (KGE, 0.77) with a of 99% confidence interval. Compared with GLASS ET algorithm v4.0, the DNN improved on the R 2 by approximately 7% (p < 0.01) and the KGE by 10%. Based on the DNN, we then generated 8-day GLASS ET product v5.0 globally with a 1 km spatial resolution from 2001 to 2015 driven by GLASS vegetation and surface net radiation (R n ) datasets and Modern-Era Retrospective Analysis for Research and Applications, Version 2 (MERRA2) datasets. Finally, this global terrestrial ET product provides a valuable dataset for monitoring regional and global water resources and environmental changes.

54 ENVIRONMENTAL SCIENCES↗

Large Antenna Multifrequency Microwave Radiometer (LAMMR) system design

The large Antenna Multifrequency Microwave Radiometer (LAMMR) is a high resolution 4 meter aperture scanning radiometer system designed to determine sea surface temperature and wind speed, atmospheric water vapor and liquid water, precipitation, and various sea ice parameters by interpreting brightness temperature images from low Earth orbiting satellites. The LAMMR with dual linear horizontal and vertical polarization radiometer channels from 1.4 to 91 GHZ can provide multidiscipline data with resolutions from 105 to 7 km. The LAMMR baseline radiometer system uses total power radiometers to achieve delta T's in the 0.5 to 1.7 K range and system calibration accuracies in the 1 to 2 deg range. A cold sky horn/ambient load two point calibration technique is used in this baseline concept and the second detector output uses an integrated and dump circuit to sample the scanning cross-tract resolution cells.

King, J. L.↗

A new sounding rocket payload for solar plasma studies

A sounding rocket payload developed for studies of high-temperature plasmas associated with solar active regions and flares is described. The payload instruments will record both spectra and images in the UV, EUV, and soft X-ray regions of the spectrum. The instruments, including the Dual Range Spectrograph, the Flat Field Soft X-ray Spectrograph, the Normal Incidence Soft X-ray Imager, the UV Filtergraph, and the H-alpha Imaging system, are described. Attention is also given to the new structural system of the payload, based on a large optical table suspended within the payload cavity, which will support the optical elements in their correct positions and orientations and will maintain these alignments throughout the rocket launch environment.

Bruner, Marilyn E.↗

High resolution, high frame rate video technology development plan and the near-term system conceptual design

The objective of the High Resolution, High Frame Rate Video Technology (HHVT) development effort is to provide technology advancements to remove constraints on the amount of high speed, detailed optical data recorded and transmitted for microgravity science and application experiments. These advancements will enable the development of video systems capable of high resolution, high frame rate video data recording, processing, and transmission. Techniques such as multichannel image scan, video parameter tradeoff, and the use of dual recording media were identified as methods of making the most efficient use of the near-term technology.

Ziemke, Robert A.↗

Citrus Inventory

An aerial color infrared (CIR) mapping system developed by Kennedy Space Center enables Florida's Charlotte County to accurately appraise its citrus groves while reducing appraisal costs. The technology was further advanced by development of a dual video system making it possible to simultaneously view images of the same area and detect changes. An image analysis system automatically surveys and photo interprets grove images as well as automatically counts trees and reports totals. The system, which saves both time and money, has potential beyond citrus grove valuation.

Source record↗

The X-ray attenuation characteristics and density of human calcaneal marrow do not change significantly during adulthood

Changes in the material characteristics of bone marrow with aging can be a significant source of error in measurements of bone density when using X-ray and ultrasound imaging modalities. In the context of computed tomography, dual-energy computed techniques have been used to correct for changes in marrow composition. However, dual-energy quantitative computed tomography (DE-QCT) protocols, while increasing the accuracy of the measurement, reduce the precision and increase the radiation dose to the patient in comparison to single-energy quantitative computed tomography (SE-QCT) protocols. If the attenuation properties of the marrow for a particular bone can be shown to be relatively constant with age, it should be possible to use single-energy techniques without experiencing errors caused by unknown marrow composition. Marrow was extracted by centrifugation from 10 mm thick frontal sections of 34 adult cadaver calcanei (28 males, 6 females, ages 17-65 years). The density and energy-dependent linear X-ray attenuation coefficient of each marrow sample were determined. For purposes of comparing our results, we then computed an effective CT number at two GE CT/i scan voltages (80 and 120 kVp) for each specimen. The coefficients of variation for the density, CT number at 80 kVp and CT number at 120 kVp were each less than 1%, and the parameters did not change significantly with age (p > 0.2, r2 < 0.02, power > 0.8 where the minimum acceptable r2 = 0.216). We could demonstrate no significant gender-associated differences in these relationships. These data suggest that calcaneal bone marrow X-ray attenuation properties and marrow density are essentially constant from the third through sixth decades of life.

NASA Discipline Musculoskeletal↗

Simplified Microarray Technique for Identifying mRNA in Rare Samples

Two simplified methods of identifying messenger ribonucleic acid (mRNA), and compact, low-power apparatuses to implement the methods, are at the proof-of-concept stage of development. These methods are related to traditional methods based on hybridization of nucleic acid, but whereas the traditional methods must be practiced in laboratory settings, these methods could be practiced in field settings. Hybridization of nucleic acid is a powerful technique for detection of specific complementary nucleic acid sequences, and is increasingly being used for detection of changes in gene expression in microarrays containing thousands of gene probes. A traditional microarray study entails at least the following six steps: 1. Purification of cellular RNA, 2. Amplification of complementary deoxyribonucleic acid [cDNA] by polymerase chain reaction (PCR), 3. Labeling of cDNA with fluorophores of Cy3 (a green cyanine dye) and Cy5 (a red cyanine dye), 4. Hybridization to a microarray chip, 5. Fluorescence scanning the array(s) with dual excitation wavelengths, and 6. Analysis of the resulting images. This six-step procedure must be performed in a laboratory because it requires bulky equipment.

Almeida, Eduardo↗

Reconciling CloudSat and GPM Estimates of Falling Snow

Satellite-based estimates of falling snow have been provided by CloudSat (launched in 2006) and the Global Precipitation Measurement (GPM) core satellite (launched in 2014). The CloudSat estimates are derived from W-band radar measurements whereas the GPM estimates are derived from its scanning Ku- and Ka-band Dual-Frequency Precipitation Radar (DPR) and 13-channel microwave imager (GMI). Each platform has advantages and disadvantages: CloudSat has higher resolution (approximately 1.5 km) and much better sensitivity (-28 dBZ), but poorer sampling (nadir-only and daytime-only since 2011) and the reflectivity-snowfall (Z-S) relationship is poorly constrained with single-frequency measurements. Meanwhile, DPR suffers from relatively poor resolution (5 km) and sensitivity (approximately 13 dBZ), but has cross-track scanning capability to cover a 245-km swath. Additionally, where Ku and Ka measurements are available, the conversion of reflectivity to snowfall rate is better-constrained than with a single frequency.

S Joseph Munchak↗