Viscosity Measurement of Highly Viscous Liquids Using Drop Coalescence in Low Gravity

The method of drop coalescence is being investigated for use as a method for determining the viscosity of highly viscous undercooled liquids. Low gravity environment is necessary in this case to minimize the undesirable effects of body forces and liquid motion in levitated drops. Also, the low gravity environment will allow for investigating large liquid volumes which can lead to much higher accuracy for the viscosity calculations than possible under 1 - g conditions. The drop coalescence method is preferred over the drop oscillation technique since the latter method can only be applied for liquids with vanishingly small viscosities. The technique developed relies on both the highly accurate solution of the Navier-Stokes equations as well as on data from experiments conducted in near zero gravity environment. In the analytical aspect of the method two liquid volumes are brought into contact which will coalesce under the action of surface tension alone. The free surface geometry development as well as its velocity during coalescence which are obtained from numerical computations are compared with an analogous experimental model. The viscosity in the numerical computations is then adjusted to bring into agreement of the experimental results with the calculations. The true liquid viscosity is the one which brings the experiment closest to the calculations. Results are presented for method validation experiments performed recently on board the NASA/KC-135 aircraft. The numerical solution for this validation case was produced using the Boundary Element Method. In these tests the viscosity of a highly viscous liquid, in this case glycerine at room temperature, was determined to high degree of accuracy using the liquid coalescence method. These experiments gave very encouraging results which will be discussed together with plans for implementing the method in a shuttle flight experiment.

Antar, Basil N.↗

Effect of External Pressure Drop on Loop Heat Pipe Operating Temperature

This paper discusses the effect of the pressure drop on the operating temperature in a loop heat pipe (LHP). Because the evaporator and the compensation chamber (CC) both contain two-phase fluid, a thermodynamic constraint exists between the temperature difference and the pressure drop for these two components. As the pressure drop increases, so will the temperature difference. The temperature difference in turn causes an increase of the heat leak from the evaporator to the CC, resulting in a higher CC temperature. Furthermore, the heat leak strongly depends on the vapor void fraction inside the evaporator core. Tests were conducted by installing a valve on the vapor line so as to vary the pressure drop, and by charging the LHP with various amounts of fluid. Test results verify that the LHP operating temperature increases with an increasing differential pressure, and the temperature increase is a strong function of the fluid inventory in the loop.

Jentung, Ku↗

Viscosity Measurement Using Drop Coalescence in Microgravity

We present in here validation studies of a new method for application in microgravity environment which measures the viscosity of highly viscous undercooled liquids using drop coalescence. The method has the advantage of avoiding heterogeneous nucleation at container walls caused by crystallization of undercooled liquids during processing. Homogeneous nucleation can also be avoided due to the rapidity of the measurement using this method. The technique relies on measurements from experiments conducted in near zero gravity environment as well as highly accurate analytical formulation for the coalescence process. The viscosity of the liquid is determined by allowing the computed free surface shape relaxation time to be adjusted in response to the measured free surface velocity for two coalescing drops. Results are presented from two sets of validation experiments for the method which were conducted on board aircraft flying parabolic trajectories. In these tests the viscosity of a highly viscous liquid, namely glycerin, was determined at different temperatures using the drop coalescence method described in here. The experiments measured the free surface velocity of two glycerin drops coalescing under the action of surface tension alone in low gravity environment using high speed photography. The liquid viscosity was determined by adjusting the computed free surface velocity values to the measured experimental data. The results of these experiments were found to agree reasonably well with the known viscosity for the test liquid used.

Antar, Basil N.↗

Monitoring Volcanoes by Use of Air-Dropped Sensor Packages

Sensor packages that would be dropped from airplanes have been proposed for pre-eruption monitoring of physical conditions on the flanks of awakening volcanoes. The purpose of such monitoring is to gather data that could contribute to understanding and prediction of the evolution of volcanic systems. Each sensor package, denoted a volcano monitoring system (VMS), would include a housing with a parachute attached at its upper end and a crushable foam impact absorber at its lower end (see figure). The housing would contain survivable low-power instrumentation that would include a Global Positioning System (GPS) receiver, an inclinometer, a seismometer, a barometer, a thermometer, and CO2 and SO2 analyzers. The housing would also contain battery power, control, data-logging, and telecommunication subsystems. The proposal for the development of the VMS calls for the use of commercially available sensor, power, and telecommunication equipment, so that efforts could be focused on integrating all of the equipment into a system that could survive impact and operate thereafter for 30 days, transmitting data on the pre-eruptive state of a target volcano to a monitoring center. In a typical scenario, VMSs would be dropped at strategically chosen locations on the flanks of a volcano once the volcano had been identified as posing a hazard from any of a variety of observations that could include eyewitness reports, scientific observations from positions on the ground, synthetic-aperture-radar scans from aircraft, and/or remote sensing from aboard spacecraft. Once dropped, the VMSs would be operated as a network of in situ sensors that would transmit data to a local monitoring center. This network would provide observations as part of an integrated volcano-hazard assessment strategy that would involve both remote sensing and timely observations from the in situ sensors. A similar strategy that involves the use of portable sensors (but not dropping of sensors from aircraft) is already in use in the Volcano Disaster Assistance Program (VDAP), which was developed by the U.S. Geological Survey and the U.S. Office of Foreign Disaster Assistance to respond to volcanic crises around the world. The VMSs would add a greatly needed capability that would enable VDAP response teams to deploy their volcano-monitoring equipment in a more timely manner with less risk to personnel in the field.

Kedar, Sharon↗

Size Distribution and Velocity of Ethanol Drops in a Rocket Combustor Burning Ethanol and Liquid Oxygen

Single jets of ethanol were studied photomicrographically inside a rocket chamber as they broke up into sprays of drops which underwent simultaneous acceleration and vaporization with chemical reaction occurring in the surrounding combustion gas stream. In each rocket test-firing, liquid oxygen was used as the oxidant. Both drop velocity and drop size distribution data were obtained from photomicrographs of the ethanol drops taken with an ultra-high speed tracking camera developed at NASA, Lewis Research Center.

Ingebo, Robert D.↗

How to Make a Microgravity Drop Tower for Your Classroom

Microgravity is quite often seen as exotic and special as astronauts float around in the International Space Station, eating MM's in mid-air, and performing science experiments, all done seemingly without gravity being present. Surprisingly enough, up on the ISS there is about 90 of the same gravity that holds you to the floor in your classroom or museum exhibit hall. Participate in this session and you will understand that and more. You can use simple devices to demonstrate microgravity conditions in your classroom or museum exhibit hall. This will be the same microgravity condition that astronauts experience on the ISS, just for a much shorter period of time. Contrary to popular opinion of some people, microgravity is NOT caused by zero gravity up there. Microgravity on the ISS is due to free fall within the Earth's gravitational field. That means you can drop an item in free fall in your classroom and museum exhibit hall and that item will experience microgravity. In this session, a short theory segment will explain and reinforce these concepts so that you may explain to others. The session will concentrate on showing the session participants how to make an effective, but inexpensive, drop tower for use in the classroom. Such a drop tower may be used to reinforce classroom instruction in physics and forces motion as well as serve as a platform for student investigations, classroom competitions, and student science or technology fair entries. Session participants will build their own simple microgravity experiment and operate them in a drop tower, compare results, and modify their experiment based on results. This material is also useful for public demonstrations at school open houses, travelling museum exhibits, fixed museum exhibits, and independent student projects or experiments. These free fall concepts also connect terrestrial demonstrations with planetary moon motion, comet trajectory, and more.

forces↗

Impact of Fluid Flow Pressure drop on Temperature of Components Controlled by Mechanically Pumped Fluid Loop Thermal Control System

In a typical thermal control system that employs a mechanically pumped fluid loop to control component temperatures, fluid flow pressure drop is minimized to ensure that adequate fluid flow can be provided by the pump. Engineers often are overly concerned about violating a maximum pressure drop, almost treating it as a “wall” that should not be crossed. The true “wall” is the control of the temperatures of the components served by the loop to ensure that their temperatures do not violate their allowed limits. As a case study, for assessing this “constraint,” sensitivity analyses were undertaken to understand if this is truly a major constraint, and to assess the impact of pressure drop exceedance on the controlled components’ temperatures. The flow impedance is varied as a parameter to understand how it affects the controlled components’ temperatures. One key finding was that the temperatures of the controlled components is relatively insensitive to the flow impedance increases. This finding is obviously most relevant to this particular case study; however, this also provides the process and guidance for assessing the performance of other pump/loop combinations in terms of their sensitivity to pressure drop impedances.

Mastropietro, Arthur J.↗

Drop Size Distribution Measurements in Outer Rainbands of Hurricane Dorian at the NASA Wallops Precipitation-Research Facility

Hurricane rainbands are very efficient rain producers, but details on drop size distributions are still lacking. This study focuses on the rainbands of hurricane Dorian as they traversed the densely instrumented NASA precipitation-research facility at Wallops Island, VA, over a period of 8 h. Drop size distribution (DSD) was measured using a high-resolution meteorological particle spectrometer (MPS) and 2D video disdrometer, both located inside a double-fence wind shield. The shape of the DSD was examined using double-moment normalization, and compared with similar shapes from semiarid and subtropical sites. Dorian rainbands had a superexponential shape at small normalized diameter values similar to those of the other sites. NASA’s S-band polarimetric radar performed range height-indicator (RHI) scans over the disdrometer site, showing some remarkable signatures in the melting layer (bright-band reflectivity peaks of 55 dBZ, a dip in the copolar correlation to 0.85 indicative of 12–15 mm wet snow, and a staggering reflectivity gradient above the 0 °C level of −10 dB/km, indicative of heavy aggregation). In the rain layer at heights < 2.5 km, polarimetric signatures indicated drop break-up as the dominant process, but drops as large as 5 mm were detected during the intense bright-band period.

Merhala Thurai↗

Evolution of Drop Size Distributions during Hurricane Harvey and Their Effects on Rain Intensity

Hurricane Harvey hit the Texas Gulf Coast as a major hurricane on August 25, 2017, before exiting the state as a tropical storm on August 29, 2017. Left in its wake was historic flooding over southeast Texas with some locations measuring more than 60 inches of rain. The Houston NEXRAD radar (KHGX) maintained operations for the entirety of the event and is utilized in this study to better understand the evolution of the drop size distribution (DSD) in the lower (liquid) portions of the storm and how changes in the DSD were tied to observed and measured changes in rain intensities. From the KHGX dual-polarimetric radar data several DSD parameters were retrieved, including three different rain rate retrievals, as well as the mass-weighted mean-drop diameter Dm, and the normalized intercept parameter NW of the gamma distribution. Two of the rain retrievals are popular hybrid approaches, where reflectivity, differential and specific differential phase are used. The other is an attenuation-based retrieval. In a previous study, it was found that both hybrid retrievals significantly underestimated the rainfall during the heaviest rain periods, while the attenuation-based retrieval, with proper adjustment, agreed quite well with a large network of gauges from the Harris County Flood Warning System. Using Dm and NW as proxies for drop size and concentration, respectively, we will show that the heaviest rain intensities were associated in areas of the storm where there was a large concentration of large drops present. It is envisaged that results of this study can be used to develop a near-real-time tuning of the attenuation-based retrieval, thus providing timely, and possibly life-saving warnings during inundating rainfall.

David B. Wolff↗

TO252: Parabolic Flight Demonstration of Fluid Dispensing Tube Performance Limits for Drop Delivery

Ring Shear Drop (RSD) ISS flight hardware failed to pin sample fluid drops between two rings, likely due to dynamic instability inherent to the dispensing tube (D-Tube) design. The first parabolic flight tested 5 D-tube tip designs with two bounding surface tension fluids, enabling an engineering design decision. D-tube Tip Cage Design was selected based on the November 2020 parabolic flight test data. Flight Operations Program (FOP) approved a reflight proposal to include 2 parabolic flight days during the April/May 2021 campaign with following objectives: • Validate ISS hardware flight design with actual flight fluids (test as you fly), demonstrating the ability to deliver 1” fluid drops in near-microgravity conditions. • Demonstrate pinning of 1” flight fluid drops: a secondary pinning ring is planned to be installed in the parabolic flight hardware to meet this objective. Fluid flow rates will also be varied as needed and as possible. • Provide data to validate computational models used to guide ISS operational deployment decisions and demonstrate the viability of the redesigned hardware to accommodate a range of future flight investigations. This presentation introduces highlights and lessons learned during this recent flight campaign for discussion in the Flight Opportunities Program Panel, “Leveraging Suborbital Flight Tests to Advance Science and Technology."

Sridhar Gorti↗

Drop Analysis of Department of Energy Standard Canister with Fort Saint Vrain SNF

DOE manages over 300 types of SNF, most of which are located at the INL site. The Idaho Cleanup Project and INL are collaborating on the Road-Ready Capability Demonstration Project, which will develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE-managed SNF at the INL site for ?road-ready dry storage?. ?Road-ready dry storage? is a SNF management concept where SNF is packaged into dry and sealed canisters, which are then placed in on-site storage in anticipation of later transportation. The forward-looking goal of the Demonstration is establishing the foundation for a large-scale road-ready dry storage program at the INL site. The Demonstration will first package Fort Saint Vrain SNF currently stored at INL into several DOE Standard Canisters. These Standard Canisters will then be loaded into another commercial transportation or storage containment system (e.g., storage cask or transportation package). The Standard Canister is a class of standardized canisters designed for containing the large variety of DOE-managed SNF during interim storage, transportation and/or disposal at a geological repository. One critical aspect of road-ready dry storage is the ability to license the DOE Standard Canisters and its associated transportation package to 10 CFR 71. Depending on the SNF and transportation strategy, the Standard Canisters may have to maintain structural integrity under normal conditions of transport and hypothetical accident scenarios (i.e., drop events). The Standard Canisters have been tested and analyzed under various SNF loading configurations and accident drop events in support of the Idaho Spent Fuel Facility and other DOE programs. However, no analysis has been completed to support the recent Demonstration. This analysis will consider the Ø0.5 m × 5.1 m Standard Canister under drop scenario(s) considered in previous INL tests and analyses, including the 9 m drop at 80 degree off vertical. However, this analysis will consider the more recent Fort Saint Vrain loading configurations proposed for the Demonstration. This analysis will performed using strain-based acceptance criteria established by the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section III, Division 3. It will be compared to previous analyses and form the foundation of further formal calculations that will be used to support licensing efforts of the road-ready dry storage system at INL.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Compressibility Effects on Heat Transfer and Pressure Drop in Smooth Cylindrical Tubes

An analysis is made to simplify pressure-drop calculations for nonadiabatic and adiabatic friction flow of air in smooth cylindrical tubes when the density changes due to heat transfer and pressure drop are appreciable. Solutions of the equation of motion are obtained by the use of Reynolds' analogy between heat transfer and skin friction. Charts of the solutions are presented for making pressure-drop calculations. A technique of using the charts to determine the position of a normal shock in a tube is described.

AIR FLOW - TUBES, CYLINDRICAL↗

Improvement of Drop‐Hammer Impact Testing for Safety Assessment of High Explosives Using 10‐mg Samples

Here, in this study, we established an improved method for drop-hammer impact testing of small quantities of high explosives (10 mg). We performed about seven hundred impact tests under various experimental conditions (e.g., sandpaper vs bare anvil, different sample masses, drop-weights, and striker diameters) to determine an optimal set of conditions and reaction detection methods (e.g., gas analysis, video, and sound recordings) that give the most statistically reliable results with 10 mg samples. We used both Frequentist and Bayesian statistical approaches to compare estimates of the drop height (DH50) that initiates a reaction 50% of the time, and to quantify the associated uncertainty. Gas analysis proved to be the most reliable reaction detection method, showing unambiguous rises in HE decomposition products (e.g., CO 2 ) even when the other indicators (e.g., sound, video) were inconclusive. The impact tests performed with a bare anvil showed much better reproducibility than those conducted with sandpaper, reducing the largest uncertainty observed in the data sets by a factor of 1.7. The DH 50 values obtained from three different sample masses (10, 20, and 35 mg) fell within the uncertainties of the measurements. We demonstrated the improved procedure (i.e., 10-mg samples, gas analysis, bare anvil, and Bayesian approach) on a variety of PETN samples having different surface areas and thermal histories.

PETN↗

Contact Angle Measurements Using Sessile Drop and Micro-CT Data from Six Sandstones

Numerous sessile drop and micro-computed tomography (micro-CT) studies have been conducted to quantify Geologic Carbon Storage formation wettability by measuring static contact angles (θ); however, the influence of pore geometry remains unknown. In this work, six sandstones (Bandera Brown, Berea, Bentheimer, Mt. Simon, Navajo, and Nugget) are used to measure θ using the two aforementioned experimental methods at identical testing conditions (45°C and 12.41 MPa). The range of θ measured at in situ conditions (micro-CT) exceeds those the range at ex situ (sessile drop method) conditions for all sandstones. However, when droplets with more representative in situ diameters are analyzed, θ averages show ex situ θ exceed those of in situ θ. Pore geometry does influence local θ, but the size of ex situ droplets relative to pore size appears to influence θ. This is an important to consider for future sessile drop studies used for analysis of CO 2 behavior in carbon storage reservoirs.

36 MATERIALS SCIENCE↗

An improved pressure drop correlation for modeling localized effects in a pebble bed reactor

Advances in the development of pebble bed reactors (PBRs) has created a desire for accurate and cost-effective simulation tools for design scoping studies and safety analysis. The current state-of-the-art for these simulations is the use of porous media models, although these models rely on correlations to capture the effects of flow features that are not explicitly modeled. One of the areas where correlation accuracy is currently lacking is in the near-wall region of the bed. In this region, the presence of the wall causes the pebbles to pack more orderly, drastically changing the geometry and flow behavior in this region. This work presents a new generalized pressure drop correlation for PBRs based on the KTA equation. A high-to-low methodology is applied, where large eddy simulation (LES) is performed on two beds of 1568 and 1700 pebbles to generate a high-fidelity dataset. The flow fields are then averaged in time and separated into concentric rings of 0.05 D peb width. Average porosity, velocity, and pressure drop are extracted for each ring and the friction and form losses are calculated. The Reynolds number range for this study is 625–10,000, and thus the form losses are dominant over the friction losses. The form losses across the rings are investigated, and a correction term for the form loss calculation is determined and applied to the KTA equation to drastically improve the capability of modeling localized porosity effects in a porous media code. Finally, the improved correlation reduces near-wall velocity prediction error from over 50% with the KTA correlation to around 5%. Agreement in pressure drop prediction between LES and porous media simulations is also improved.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Pressure Drop with Moving Contact Lines and Dynamic Contact Angles in a Hydrophobic Round Minichannel: Visualization via Synchrotron X-ray Imaging and Verification of Experimental Correlations

In hydrophobic mini- and microchannels, slug flow with moving contact lines is typically generated under various two-phase flow conditions. There is a significant pressure drop in this flow pattern with moving contact lines, which is closely related to the dynamic contact angles. Researchers have investigated dynamic contact angles experimentally for decades, but due to the limitations of visualization techniques, these experiments have typically been conducted in low Weber number regions (We < 10 –3 ). In this study, we clearly visualized the dynamic contact angles of a liquid slug in high Weber number regions (10 –3 < We <1) via synchrotron X-ray imaging with high temporal (~1000 fps) and spatial (~ 2 μm/pixel) resolutions. We precisely measured the pressure drop with moving contact lines in a hydrophobic minichannel (inner diameter = 1.018 mm). On the basis of our experimental data, we verified previous correlations for dynamic contact angles and explored the relationship between pressure drop with moving contact lines and dynamic contact angles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaporation and propagation of liquid drop streams at vacuum pressures: Experiments and modeling

Evaporation of streams of liquid droplets in environments at vacuum pressures below the vapor pressure has not been widely studied. Here, experiments and simulations are reported that quantify the change in droplet diameter when a steady stream of ≈100 μm diameter drops is injected into a chamber initially evacuated to <10 –8 bar. In experiments, droplets fall through the center of a 0.8 m long liquid nitrogen cooled shroud, simulating infinity radiation and vapor mass flux boundary conditions. Furthermore, experimentally measured changes in drop diameters vary from ≈0 to 6 μm when the initial vapor pressure is increased from 10 –6 to 10 –3 bar by heating the liquid. Measured diameter changes are predicted by a model based on the Hertz-Knudsen equation. One uncertainty in the calculation is the “sticking coefficient” β. Assuming a constant β for all conditions studied here, predicted diameter changes best match measurements with β≈0.3. This value falls within the range of β reported in the literature for organic liquids. Finally, at the higher vapor pressure conditions considered here, the drop stream disperses transverse to the main flow direction. This spread is attributed to forces imparted by an absolute pressure gradient produced by the evaporating stream.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗