Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “districts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Sacramento Municipal Utility District PV and Smart Grid Pilot at Anatolia

Under DE-FOA-0000085 High Penetration Solar Deployment, the U. S. Department of Energy funded agreements with SMUD and Navigant Consulting, SunPower, GridPoint, the National Renewable Energy Laboratory, and the California Energy Commission for this pilot demonstration project. Funding was $5,962,409.00. Cost share of $500,000 was also provided by the California Energy Commission. The project has strategic implications for SMUD, other utilities and the PV and energy-storage industries in business and resource planning, technology deployment and asset management. These implications include: -At this point, no dominant business models have emerged and the industry is open for new ideas. -Demonstrated two business models for using distributed PV and energy storage, and brainstormed several dozen more, each with different pros and cons for SMUD, its customers and the industry. -Energy storage can be used to manage high penetrations of PV and mitigate potential issues such as reverse power flow, voltage control violations, power quality issues, increased wear and tear on utility equipment, and system wide power supply issues. - Smart meters are another tool utilities can use to manage high penetrations of PV. The necessary equipment and protocols exist, and the next step is to determine how to integrate the functionality with utility programs and what level of utility control is required. - Time-of-use rates for the residential customers who hosted energy storage systems did not cause a significant change in energy usage patterns. However, the rates we used were not optimized for PV and energy storage. Opportunities exist for utilities to develop new structures.

14 SOLAR ENERGY↗

District Energy Corporation SW 40th Street Thermal Energy Plant

The overall deliverable from the project is the design, construction and commissioning of a detention facility heating and cooling system that minimizes ownership costs and maximizes efficiency (and therefore minimizes environmental impact). The primary deliverables were the proof of concept for the application of geothermal systems for an institutional facility and the ongoing, quarterly system operating data downloads to the Department of Energy . The primary advantage of geothermal based heat pump systems is the higher efficiency of the system compared to a conventional chiller, boiler, cooling tower based system. The higher efficiency results in a smaller environmental foot print and lower energy costs for the detention facility owner, Lancaster County. The higher efficiency for building cooling is primarily due to a more constant compressor condensing temperature with the geothermal well field acting as a thermal “sink” (in place of the conventional system’s cooling tower). In the heating mode, Ground Couple Heat Pump (GCHP) systems benefits from the advantage of a heat pump Coefficient of Performance (COP) of approximately 3.6, significantly better than a conventional gas boiler. The geothermal well field acting as a thermal “source” allows the heat pumps to operate efficiently in the heating mode regardless of ambient temperatures. The well field is partially located in a wetland with a high water table so, over time, the project will be able to identify the thermal loading characteristics of a well field located in a high water table location. The project demonstrated how a large geothermal well field can be installed in a wetland area in an economical and environmentally sound manner. Finally, the SW 40th Street Thermal Energy Plant project demonstrates the benefits of providing domestic hot water energy, as well as space heating, to help balance well filed thermal loading in a cooling dominated application. During the period of August 2012 thru March 2014, with the detention facility occupied for the final seven months, the well field supply water temperatures to the heat pumps dropped to a minimum of 39°F and reached a maximum temperature of 68 °F while providing 15,819 MMBtu of cooling energy and 27,467 MMBtu of heating energy. During this period the peak recorded system cooling load was 610 tons and the peak heating load was 8.4 MMBtu. The DEC is currently evaluating the most beneficial electric rate for plant operations. Total project cost of $16.9 million was approximately $3.2 million less than the estimate provided in the grant application. The reduction in project costs were primarily due to favorable construction material prices as well as strong competition in the local construction contractor market. The DEC plant reached the substantial completion milestone in December 2011 and began providing thermal service to the detention facility in January 2012 when the building’s HVAC system was ready to accept heating service. The plant reached commercial operating status on August 1, 2012. However, due to construction delays, the detention facility was not occupied until September of 2013. The detention facility construction delays also impacted the installation and commissioning of the project’s dedicated domestic hot water heat pump. Final coordination with the detention facility’s building management system vendor to establish network links for the exchange of date is currently being completed. This will allow the development of control sequences for the optimal operation of the domestic hot water system.

15 GEOTHERMAL ENERGY↗

Snohomish Public Utility District: An Assessment of Battery Technical Performance

This report investigates the technical performance of the SnoPUD MESA-1 BESS facility, consisting of two battery sub-systems 1a and 1b, based on a number of baseline and use case tests. Baseline tests were intended to assess the general technical capability of the BESS (e.g., stored energy capacity, ramp rate performance, ability to track variable charge/discharge commands, direct current (DC) battery internal resistance) while the use case tests were intended to examine the performance of the BESS while engaged in specific economic services (e.g., arbitrage, power factor correction).

25 ENERGY STORAGE↗

Snohomish Public Utility District MESA 2: An Assessment of Flow Battery Energy Storage System Technical Performance

This report investigates the technical performance of the 2.2 MW, 8 MWh MESA 2 advanced vanadium flow battery energy storage system (FBESS), consisting of four 0.55 MW, 2 MWh strings, based on a number of baseline and use case tests. The FBESS is located at the Everett, Washington substation and owned by SnoPUD. The FBESS was procured by SnoPUD with matching funds by the Washington Clean Energy. Baseline tests were intended to assess the general technical capability of the FBESS (e.g., stored energy capacity, ramp rate performance, ability to track varying charge/discharge commands, direct current (DC) battery internal resistance). Use case tests were used to examine the performance of the FBESS while engaged in specific grid services (e.g., arbitrage, power factor correction). The project measured and/or calculated parameters that are important for understanding FBESS performance when subjected to actual field operation for achieving economic benefits, e.g., round trip efficiency (RTE) with and without rest, with and without auxiliary loads, auxiliary power consumption, signal command tracking, temperature trends during operation, parasitic power loss unaccounted by auxiliary load during rest, and state of charge (SOC) excursions. These baseline and use case parameters were analyzed using recorded test results. In addition, the results and lessons presented herein are also beneficial for any task or effort that needs technical assessment on similar and different types of FBESS based on technical specifications and/or field deployment results, since the assessment methodology remains the same.

25 ENERGY STORAGE↗

Cost Effectiveness of ASHRAE Standard 90.1-2016 for the District of Columbia

This report describes the methodology and results of a state cost-effectiveness analysis of ASHRAE Standard 90.1-2016. Moving to the Standard 90.1-2016 edition from Standard 90.1-2013 is found to be cost-effective for the state. Annual energy cost savings, added construction costs, and life-cycle costs are all described and presented here for various building types and climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost-Effectiveness of ANSI/ASHRAE/IES Standard 90.1-2019 for District of Columbia

This report describes the methodology and results of a state cost-effectiveness analysis of ASHRAE Standard 90.1-2019. Moving to the Standard 90.1-2019 edition from Standard 90.1-2016 is found to be cost-effective for the state. Annual energy cost savings, added construction costs, and life-cycle costs are all described and presented here for various building types and climate zones.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy to Communities Program Short Introduction: Evaluation of Enhanced Geothermal System for Cornell District Heating [Slides]

Through the U.S. Department of Energy's Energy to Communities (E2C) program, NLR, other national laboratory experts, and select organizations provide Expert Match - free, short-term technical assistance to address near-term energy challenges and questions. Expert Match is for community stakeholders who have decision-making power or influence in their community but need access to additional energy expertise to inform key upcoming decisions. This Expert Match request supported Cornell University (Itaca, NY) community efforts in developing Enhanced Geothermal System (EGS) reservoir performance, by simulating fracture flow to estimate pressure drop, flow distribution, and heat extraction efficiency in fractured rock. Thermal drawdown modeling was used to assess long-term resource sustainability, while system optimization studies refined key parameters such as well configuration and flow rate to improve overall reservoir efficiency.

15 GEOTHERMAL ENERGY↗

District Geothermal Heating + Cooling Deployment in a CT Environmental Justice Community

The report marks the team’s completion of all required tasks and milestones. Work completed for Task 1 (Technical and Economic Feasibility Assessment & Procurement Drafting) included development of analysis and design model; completion of technical, economic, and environmental assessments; and technical outreach and coalition design. Components for Task 2 (Outreach & Community Engagement) involved broad outreach and community-engagement efforts (including stakeholder meetings and a webinar as well as development of a formal engagement plan) and development of a web page and a case study. For Task 3 (Workforce Transition, Development, & Training Plan), the team undertook a formal statewide geothermal workforce needs assessment, developed corresponding recommendations for both the state as a whole and the Wallingford project, and held several workshops. For Task 4 (Project Management & Data Sharing), the team drafted a data-sharing plan.

15 GEOTHERMAL ENERGY↗

National Fuel Cell Bus Program: Accelerated Testing Evaluation Report and Appendices, Alameda-Contra Costa Transit District (AC Transit)

This is an evaluation of hydrogen fuel cell transit buses operating at AC Transit in revenue service since March 20, 2006 compared to similar diesel buses operating from the same depot. This evaluation report includes results from November 2007 through October 2008. Evaluation results include implementation experience, fueling station operation, fuel cell bus operations at Golden Gate Transit, and evaluation results at AC Transit (bus usage, availability, fuel economy, maintenance costs, and roadcalls).

02 PETROLEUM↗

National Fuel Cell Bus Program: Accelerated Testing Evaluation Report #2, Alameda-Contra Costa Transit District (AC Transit) and Appendices

This is an evaluation of hydrogen fuel cell transit buses operating at AC Transit in revenue service since March 20, 2006, comparing similar diesel buses operating from the same depot. It covers November 2007 through February 2010. Results include implementation experience, fueling station operation, evaluation results at AC Transit (bus usage, availability, fuel economy, maintenance costs, and road calls), and a summary of achievements and challenges encountered during the demonstration.

08 HYDROGEN↗

Growth and Stability of Stratiform Carrollite (CuCo2S4) in the Tenke-Fungurume Ore District, Central African Copperbelt

Abstract Carrollite (CuCo2S4) is the main ore mineral of the critical battery metal cobalt, yet, surprisingly, detailed characterization of its thermodynamic properties and of its trace element contents remain sparse in the scientific literature. To fill these knowledge gaps, we generated the first thermodynamic data set for carrollite using well-characterized samples obtained from the stratiform sulfide mineralization style at Fungurume 88 deposit in the Democratic Republic of Congo. Detailed mineralogical investigation of these same samples suggests that carrollite has limited ability to incorporate other ‘sweetener’ elements (except Cu and Ni) by substitution mechanisms. Modeling using CHNOSZ 2.0.0. software and an integrated Cu-Co-S-O thermodynamic data set provides insights into the stability of carrollite relative to other Co-bearing minerals under physicochemical conditions relevant to the Central African Copperbelt. Further exploration of these models indicates that dropping redox potential in the mineralizing system is insufficient to explain the mineral-scale and deposit-scale zonation patterns commonly observed in Cu-Co deposits of the Central African Copperbelt. Instead, factors such as increasing pH, decreasing T, decreasing sulfur activity, or some combination of changing physicochemical parameters may need to be invoked to explain these zonation trends. At the Fungurume 88 deposit, the absence of linnaeite (Co3S4) suggests that ore precipitation occurred at temperatures cooler than 211 °C. From our pH-logfO2 diagrams, and relative to higher temperatures, such a lower T regime is marked by a greater degree of offset between the modeled Cu and Co solubility contours, thus facilitating a more differentiated and zoned distribution of these two metals at the deposit scale. Our models are offered to the geoscience community as exceptionally useful tools for modeling and visualizing the Cu-Co-S-O systematics and may be applied to a variety of geological and geometallurgical questions in the Central African Copperbelt and other deposits elsewhere.

Mineralogy↗

Sacramento Municipal Utility District (SMUD): Rotating Shadowband Radiometer (RSR); Anatolia - Rancho Cordova, California (Data)

A partnership with industry and U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to collect solar data to support future solar power generation in the United States. The measurement station monitors global horizontal, direct normal, and diffuse horizontal irradiance to define the amount of solar energy that hits this particular location. The solar measurement instrumentation is also accompanied by meteorological monitoring equipment to provide scientists with a complete picture of the solar power possibilities.

14 SOLAR ENERGY↗