Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distribution network”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Memory Network For Distributed Data Processors

Universal Memory Network (UMN) is modular, digital data-communication system enabling computers with differing bus architectures to share 32-bit-wide data between locations up to 3 km apart with less than one millisecond of latency. Makes it possible to design sophisticated real-time and near-real-time data-processing systems without data-transfer "bottlenecks". This enterprise network permits transmission of volume of data equivalent to an encyclopedia each second. Facilities benefiting from Universal Memory Network include telemetry stations, simulation facilities, power-plants, and large laboratories or any facility sharing very large volumes of data. Main hub of UMN is reflection center including smaller hubs called Shared Memory Interfaces.

Bolen, David↗

DGs for Service Restoration to Critical Loads in a Secondary Network

During a major outage in a secondary network distribution system, distributed generators (DGs) connected to the primary feeders as well as the secondary network can be used to serve critical loads. This paper proposed a resilience-oriented method to determine restoration strategies for secondary network distribution systems after a major disaster. Technical issues associated with the restoration process are analyzed, including the operation of network protectors, inrush currents caused by the energization of network transformers, synchronization of DGs to the network, and circulating currents among DGs. A look-ahead load restoration framework is proposed, incorporating technical issues associated with secondary networks, limits on DG capacity and generation resources, dynamic constraints, and operational limits. The entire outage duration is divided into a sequence of periods. Restoration strategies can be adjusted at the beginning of each period using the latest information. Numerical simulation of the modified IEEE 342-node low voltage networked test system is performed to validate the effectiveness of the proposed method.

Xu, Yin (ORCID:0000000209459024)↗

Background Information on the Protection Requirements in IEEE Std 1547-2018

As the DER penetration level has risen significantly in recent times, parameter settings and configuration of installed DERs are having direct impact on local electric distribution utilities as well as bulk power systems during normal and abnormal grid conditions. On the other hand, all grid-connected DERs in the United States of America must conform to the interconnection requirements prescribed in the IEEE Std 1547-2018. Because of these reasons, it is crucial to understand the expected DER performance during abnormal grid conditions considering the requirements of the IEEE Std 1547-2018. The aim of this document is twofold: (1) to summarize requirements in IEEE Std 1547-2018 having direct implications in distribution network protection, and (2) to provide the reader with knowledge and information that will be required for users to apply the requirements specified. Since the focus of this document is on distribution network protection in the presence of DERs, it is assumed that the readers have basic understanding of distribution network protection as well as working principles of DERs. This document starts with a brief introduction on protection systems for distribution network followed by a discussion on the impact of DER on the protection systems. Current practices to provide network protection in the presence of DER is briefly discussed. The document then explores the DER performance requirements in IEEE Std. 1547-2018; especially on those related to distribution network protection. Section 6.1 in IEEE Std. 1547-2018 provides an overview of capabilities and control requirements for DER under abnormal operating conditions. This section also introduces abnormal operating performance categories I, II, III. The DER response to various types of faults and grid conditions such as short-circuit faults and open phase conditions are discussed in section 6.2 in the standard while requirements for coordination with the Area EPS reclosing scheme are provided in section 6.3. Section 6.4 in the IEEE Std 1547-2018 specifies requirements for mandatory voltage tripping and ride-through requirements during low and high voltage disturbances and section 6.5 specifies similar requirements for low and high frequency disturbances. IEEE Std. 1547 requires that the conformance of the DERs to IEEE Std 1547-2018 requirements should be verified in accordance with IEEE Std. 1547. 1. There are several parameters and settings of DERs that need to be properly selected for reliable operation during abnormal grid condition while applying the requirements of IEEE Std 1547-2018. Key decisions for proper selections of parameter and settings are: 1. Determination of required DER abnormal operating performance category, 2. Determination of DER response (shall trip) to abnormal voltages and 3. Determination of DER response (shall trip) to abnormal frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Battery Energy Storage Scheduling for Optimal Load Variance Minimization

Generation portfolio can be significantly altered due to the deployment of distributed energy resources (DER) in distribution networks and the concept of microgrid. Generally,distribution networks can operate in a more resilient and economic fashion through proper coordination of DER. However, due to the partially uncontrollable and stochastic nature of some DER, the variance of net load of distribution systems increases, which raises the operational cost and complicates operation for transmission companies. This motivates peak shaving and valley filling using energy storage units deployed in distribution systems. This paper aims at theoretical formulation of optimal load variance minimization, where the infinity norm of net load is minimized. Then, the problem is reformulated equivalently as a linear program. A case study is performed with capacity limited battery energy storage model and the simplified power flow model of a radial distribution network. The influence of capacity limit and deployment location are studied.

Melin, Alexander↗

A Game-Theoretic Approach to Modeling Attacks and Defenses of Smart Grids at Three Levels

As optimization, user capabilities, and data-taking abilities are incorporated into next-generation power grids, or smart grids, they face cyber threats. The traditional electrical grid could only be damaged by physical attacks; however thesmart grid can suffer remote/cyber attacks, which have not been studied extensively in the literature. The electrical grid forms the backbone of the modern society and its security has significant implications in military settings. This paper applies game theory to model three-levels (power plants, transmission, and distribution networks) of defenses and attacks in smart grid network security. We characterize both the attacker and the defender (who interact at three network levels: distribution, transmission, and power plants) best responses and equilibrium strategies. We find that the defender's best response is not only a function of direct attacks but also of the spread from connected networks. Sensitivity analyses of the equilibrium strategies show that when success probability of an attack against power plantsreaches a threshold, the defender increases defending efforts for power plants. In contrast, the attack eort at all levels is not affected by this probability. This paper provides some novel insights to modeling and analyzing the emerging threats to the growing smart grid networks.

Rao, Nageswara S.↗

A Three-Phase Microgrid Restoration Model Considering Unbalanced Operation of Distributed Generation

Recent severe outages highlight the urgency of improving grid resiliency in the U.S. Microgrid formation schemes are proposed to restore critical loads after outages occur. Most distribution networks have unbalanced configurations that are not represented in sufficient detail by single-phase models. This study provides a microgrid formation plan that adopts a three-phase network model to represent unbalanced distribution networks. The problem formulation has a quadratic objective function with mixed-integer linear constraints. The three-phase network model enables us to examine the three-phase power outputs of distributed generators (DGs), preventing unbalanced operation that might trip DGs. Because the DG unbalanced operation constraint is non-convex, an iterative process is presented that checks whether the unbalanced operation limits for DGs are satisfied after each iteration of optimization. We also develop a relatively conservative linear approximation on the unbalanced operation constraint to handle larger networks. Compared with the iterative solution process, the conservative linear approximation is able to accelerate the solution process at the cost of sacrificing optimality to a limited extent. Simulation in the IEEE 34 node and IEEE 123 test feeders indicate that the proposed method yields more practical microgrid formations results. In addition, this paper explores the coordinated operation of DGs and energy storage (ES) installations. The unbalanced three-phase outputs of ESs combined with the relatively balanced outputs of DGs could supply unbalanced loads. In conclusion, the case study also validates the DG-ES coordination.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Distributed Framework for Coordinated Heavy-Duty Vehicle Platooning

Heavy-duty vehicles (HDVs) traveling in single file with small intervehicle distances experience reduced aerodynamic drag and, therefore, have improved fuel economy. In this paper, we attempt to maximize the amount of fuel saved by coordinating platoon formation using a distributed network of controllers. These virtual controllers, placed at major intersections in a road network, help coordinate the velocity of approaching vehicles so they arrive at the junction simultaneously and can therefore platoon. This control is initiated only if the cost of forming the platoon is smaller than the savings incurred from platooning. In a large-scale simulation of the German Autobahn network, we observe that savings surpassing 5% when only a few thousand vehicles participate in the system. These results are corroborated by an analysis of real-world HDV data that show significant platooning opportunities currently exist, suggesting that a slightly invasive network of distributed controllers, such as the one proposed in this paper, can yield considerable savings.

33 ADVANCED PROPULSION SYSTEMS↗

Decentralized Energy Management System for Networked Microgrids in Grid-connected and Islanded Modes

This paper proposes a decentralized energy management system (EMS) for the coordinated operation of networked Microgirds (MGs) in a distribution system. In the grid-connected mode, the distribution network operator (DNO) and each MG are considered as distinct entities with individual objectives to minimize their own operation costs. It is assumed that both dispatchable and renewable energy source (RES)-based distributed generators (DGs) exist in the distribution network and the networked MGs. In order to coordinate the operation of all entities, we apply a decentralized bi-level algorithm to solve the problem with the first level to conduct negotiations among all entities and the second level to update the non-converging penalties. In the islanded mode, the objective of each MG is to maintain a reliable power supply to its customers. In order to take into account the uncertainties of DG outputs and load consumption, we formulate the problems as two-stage stochastic programs. The first stage is to determine base generation setpoints based on the forecasts and the second stage is to adjust the generation outputs based on the realized scenarios. Case studies of a distribution system with networked MGs demonstrate the effectiveness of the proposed methodology in both grid-connected and islanded modes.

Distributed Generator (DG)↗

Transmission-and-Distribution Dynamic Co-simulation Framework for Distributed Energy Resource Frequency Response

The rapid deployment of distributed energy resources (DERs) in distribution networks has made it challenging to balance the transmission system and stabilize frequency. DERs have the ability to provide frequency regulation services; however, existing frequency dynamic simulation tools - which were developed mainly for the transmission system - lack the capability to simulate distribution network dynamics with high penetrations of DERs. Although electromagnetic transient simulation tools can simulate distribution network dynamics, the computation efficiency limits their use for large-scale transmission-and-distribution (T&D) co-simulation. This paper presents an efficient open-source T&D dynamic co-simulation framework for DER frequency response based on the HELICS platform and off-the-shelf T&D simulators. The challenge of synchronizing the simulation time between the transmission network and the DERs in the distribution network is solved through the detailed modeling of DERs in frequency dynamic models while DER power flow models are also preserved in the distribution networks, thereby respecting local voltage constraints when dispatching DER power for frequency response. DER frequency response (primary and secondary) is simulated in case studies to validate the proposed framework. Last, the accuracy of the proposed co-simulation model is benchmarked, and a large T&D system simulation (2k transmission and 1M distribution nodes) is presented to demonstrate the efficiency and effectiveness of the overall framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robustness of a distributed neural network controller for locomotion in a hexapod robot

A distributed neural-network controller for locomotion, based on insect neurobiology, has been used to control a hexapod robot. How robust is this controller? Disabling any single sensor, effector, or central component did not prevent the robot from walking. Furthermore, statically stable gaits could be established using either sensor input or central connections. Thus, a complex interplay between central neural elements and sensor inputs is responsible for the robustness of the controller and its ability to generate a continuous range of gaits. These results suggest that biologically inspired neural-network controllers may be a robust method for robotic control.

Chiel, Hillel J.↗

Multi-layered Resilient Microgrid Networks

Distribution grid resilience, especially when the grid is under high penetration of Distributed Energy Resources (DER), e.g. PV and energy storage, is essential to ensure the quality of electric power services. The resiliency aspect is particularly important for critical loads that typically include hospitals, police/fire stations, and national security facilities. Networks of multiple interconnected reconfigurable microgrids help to increase renewable energy penetration and may be used as basic building blocks for implementing future resilient power grids. However, this integration requires additional layers of communications, both horizontal and vertical, which may substantially increase the potential cyber attack surfaces as well as escalate risks for wide-spread malfunctions of automation systems. The Mulit-layered Resilient Microgrid Networks project is an industry-academic collaboration between ABB, Duke Energy and the University of Illinois at Urbana-Champaign (UIUC) that has developed and demonstrated a cyber-physical resilient control and communication architecture for deployment of multiple microgrid networks, as well as retrofitting the existing distribution grids by increasing DER penetration levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimum aggregation of geographically distributed flexible resources in strategic smart-grid/microgrid locations

This paper determines optimum aggregation areas for a given distribution network considering spatial distribution of loads and costs of aggregation. An elitist genetic algorithm combined with a hierarchical clustering and a Thevenin network reduction is implemented to compute strategic locations and aggregate demand within each area. The aggregation reduces large distribution networks having thousands of nodes to an equivalent network with few aggregated loads, thereby significantly reducing the computational burden. Furthermore, it not only helps distribution system operators in making faster operational decisions by understanding during which time of the day will be in need of flexibility, from which specific area, and in which amount, but also enables the flexibilities stemming from small distributed resources to be traded in various power/energy markets. A combination of central and local aggregation scheme where a central aggregator enables market participation, while local aggregators materialize the accepted bids, is implemented to realize this concept. The effectiveness of the proposed method is evaluated by comparing network performances with and without aggregation. Finally, for a given network configuration, steady-state performance of aggregated network is significantly accurate (≈ ±1.5% error) compared to very high errors associated with forecast of individual consumer demand.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Peer-to-Peer Energy Trading under Network Constraints Based on Generalized Fast Dual Ascent

We report the wide deployment of renewable energy resources, combined with a more proactive demand-side management, is inducing a new paradigm in both power system operation and electricity market trading, which especially boosts the emergence of the peer-to-peer (P2P) market. A more flexible local market mechanism is highly desirable in response to fast changes in renewable power generation at the distribution network level. Moreover, large-scale implementation of P2P energy trading inevitably affects the secure and economic operation of the distribution network. This paper presents a new P2P electricity trading framework with distribution network security constraints considered using the generalized fast dual ascent method. First, an event-driven local P2P market framework is presented to facilitate short-term or immediate local energy transactions. Then, the sensitivity analysis of nodal voltage and network loss with respect to nodal power injections is used to evaluate the impacts of P2P transactions on the distribution network, which ensures the secure operation of the distribution system. Thereby, the external operational constraints are internalized, and the cost of P2P energy trading can be appropriately allocated in an endogenous way. Moreover, a generalized fast dual ascent method is employed to implement distributed market-clearing efficiently. Finally, numerical results indicate that the proposed model could guarantee secure operation of the distribution system with P2P energy trading, and the solution method enjoys good convergence performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Joint Sparsity Pattern Recovery With 1-b Compressive Sensing in Distributed Sensor Networks

In this paper, we study the problem of joint sparse support recovery with 1-b quantized compressive measurements in a distributed sensor network. Multiple nodes in the network are assumed to observe sparse signals having the same but unknown sparse support. Each node quantizes its measurement vector element-wise to 1 b. First, we consider that all the quantized measurements are available at a central fusion center. We derive performance bounds for sparsity pattern recovery using 1-bit quantized measurements from multiple sensors when the maximum likelihood decoder is employed. We further develop two computationally tractable algorithms for joint sparse support recovery in the centralized setting. One algorithm minimizes a cost function defined as the sum of the likelihood function and the l-∝ quasi-norm, while the other algorithm extends the binary iterative hard thresholding algorithm to the multiple measurement vector case. Second, we consider a decentralized setting where each node transmits 1-b measurements to its one-hop neighbors. The basic idea behind the algorithms developed in the decentralized setting is to embed collaboration among nodes and fusion strategies. We show that even with noisy 1-b compressed measurements, joint support recovery can be carried out accurately in both centralized and decentralized settings. Additionally, we further show that the performance of the proposed 1-bit compressive sensing-based algorithms is very close to that of their real-valued counterparts except when the signal-to-noise ratio is very small.

97 MATHEMATICS AND COMPUTING↗

Use of a three-layer distributed RC network to produce two pairs of complex conjugate zeros

The properties of a three layer distributed RC network consisting of two layers of resistive material separated by a dielectric are described. When the three layer network is used as a three terminal element by connecting conducting terminal strips across the ends of one of the resistive layers and the center of the other resistive layer, the network may be used to produce pairs of complex conjugate transmission zeros. The location of these zeros are determined by the parameters of the network. Design charts for determining the zero positions are included as part of the report.

Huelsman, L. P.↗