Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Power Electronic Hardware-in-the-Loop (PE-HIL): Testing Individual Controllers in Large-Scale Power Electronics Systems

Large power electronics systems like multi-port autonomous reconfigurable solar power plant (MARS) are increasingly being researched upon to integrate emerging energy sources. MARS connects photovoltaic (PV) systems and energy storage systems (ESSs) to high-voltage direct current (HVdc) links/grids and high-voltage alternating current (ac) transmission grids. As these large power electronics systems incorporate complex hierarchical control systems that are close-by and communicate fast, the control systems require an unique power electronic hardware-in-the-loop (PE-HIL) real-time architecture to evaluate individual controllers. In this paper, a PE-HIL real-time architecture is proposed to evaluate one of the hundreds to thousands of digital signal processors (DSPs) that are a part of the complex hierarchical control system. The DSP connects to a central processing unit (CPU) and a field programmable gate array (FPGA) that form a part of the upper levels of the control system. The DSP is part of the lower level of the control system. The proposed PE-HIL architecture is tested and evaluated. Preliminary test results are presented to showcase the concept.

Debnath, Suman↗

Hardware-based Advanced Electromagnetic Transient Simulation for A Large-Scale PV Plant in Real Time Digital Simulator

Power electronics-based resources, such as high-voltage direct current (HVdc) substations, photovoltaic (PV) plants, wind plants, electric vehicle charging stations, and energy storage systems, are increasingly being integrated within the power grid. Recently, multiple reports have emphasized the necessity for high-fidelity electromagnetic transient (EMT) simulations of these large-scale power electronics-based resources to accurately understand their behavior in power grids. However, performing hardware-based EMT simulations with high-fidelity models for such large power electronics systems is challenging due to the small time-step requirements and the involvement of a large number of states. This paper presents the implementation of hardware-based high-fidelity EMT dynamic model of a large-scale PV plant, accomplished through custom model development using the specific-C language in real-time digital simulator hardware (RTDS) and software (RSCAD).

Choi, Jongchan↗

Model Based Predictive Control for Frequency Support in Multi-port Autonomous Reconfigurable Solar Plants

Primary frequency support functionality can be an added advantage for any new grid integrated power electronics resource. With increased penetration of power electronics resources, inertial and primary frequency response capabilities are decreasing. In this research paper, an advanced model-based predictive control (MBPC) algorithm for providing frequency support to a new topology of integrated photovoltaic(PV), batterybased energy storage systems (ESS), and high-voltage direct current (HV dc) systems called multi-port autonomus reconfigurable solar (MARS) plants is based on the synchronverter-based control. The simulation of MARS-HV dc system with proposed control strategy is simulated and validated for MARS connected to low short circuit ratio (SCR) grids in PSCAD/EMTDC simulation environment. The control algorithm proposed showcases better performance in terms of frequency nadir improvement and frequency steady state improvemnt with respect to no frequency control.

Marthi, Phani Ratna Vanamali↗

Characterizing HVDC Transmission Flexibility under Extreme Operating Conditions

System operators rely on system flexibility, traditionally mainly from generation, to handle unexpected reliability and resilience events, ranging from excessive resource forecast errors to extreme events like heatwaves, earthquakes, and cyberattacks. Flexible transmission, such as controllable high voltage direct current (HVDC) transmission systems present an opportunity to increase overall system flexibility to accommodate operational challenges. This paper provides a methodology to study contributions to system flexibility by controllable, power electronics based transmission. The Western Electricity Coordinating Council (WECC) system is used as an example to study contributions from existing and future HVDC lines. Under extreme system conditions, it is identified that HVDC transmission flexibility can contribute with 24.8 to 28% of avoided unserved energy, and in some areas, the benefits amount to 50 to 70%.

HVDC transmission, PCM, Balancing authorities↗

Copper-Clad Aluminum Windings as an Alternative Conductor for High-Power Electric Vehicle Wireless Charging

In this paper, copper and copper-clad aluminum winding conductors were compared. The effective resistances as functions of frequency for the cored coils were compared using the 3D finite element model frequency sweep analysis for low, medium, and high frequencies. To compare equivalent designs, both coils were designed to have similar direct-current resistance. Benefits of the copper-clad aluminum over the copper coils are presented.

Wojda, Rafal↗

Generalized Power Flow Model of an Extra High-Power Multi-Terminal HVdc Transmission Grid with Parallel-Connected and Voltage-Stacked Converters

To increase power transfer capacity of high-voltage direct current (HVdc) transmission, a new extra high-power HVdc architecture with multiple standard modular multilevel converters (MMCs) per substation has recently been introduced. This paper proposes a power flow model for a multi-terminal HVdc (MTdc) grid with this innovative substation architecture. The proposed MTdc model can be integrated seamlessly with existing ac-dc power flow algorithms with minimal modifications. The model is applicable to various MTdc grid types and topologies, different numbers of dc buses, dc lines, and MMCs per substation, along with diverse control parameters. In addition, it accurately captures both balanced and unbalanced operations of the MTdc grid. The proposed model is verified using a 5-terminal bipole MTdc grid that spans 4 areas in the Eastern Interconnection system of the USA. The numerical solutions obtained from unified and sequential ac-dc power flow algorithms under different operating conditions closely match the time-domain simulation results in PSCAD, validating the accuracy and versatility of the proposed MTdc power flow model.

Nguyen, Quan H.↗

Frequency Response and Congestion Management using Multi-Terminal HVDC Overlay

Continental level power system interconnections using a High Voltage direct current (HVDC) transmission lines have been considered to bring economic benefits such as interregional power exchange. This paper describes the modeling process and studies the technical benefits of having multiple HVDC lines, including a grid of HVDC lines (macrogrid) configuration, connecting the North American Eastern and Western electric power interconnections. The models developed provide steady state and stability analysis for multiple HVDC overlay topologies and provide technical benefit analysis in terms of frequency response and congestions management. The paper also provides a comparison of different HVDC topologies performance and their grid support in case of major disturbances

Tbaileh, Ahmad↗

A new HVdc Substation Architecture with Higher Power Transfer Capability

The power transferred through high voltage direct current transmission (HVdc) systems is increasing with increased resilience and reliability needs as well as large scale deployment of renewable energy systems. In this paper, a new HVdc substation (SS) architecture with higher power transfer capability is proposed. The HVdc converters or valve groups (VG) are connected in series and parallel fashion such that the total power rating of the SS is increased. The control challenges associated with such SS architecture are identified and appropriate control modifications are proposed. The same is verified through PSCAD based simulations.

Jaldanki, Sreenivasa↗

Towards the Flexibility of HVDC-Interconnected Systems: A Novel Emergency Freqeuncy Response Model

In this paper, we propose a novel multi-time scale emergency frequency response model by unlocking the flexibility of High Voltage Direct Current (HVDC) systems. Unlike assigning power ramping rates for FACTS to regulate frequency in traditional methods, this paper designs a step-change electromagnetic power frequency response (EPFR) scheme, by leveraging the temporal over/under DC voltage capability of HVDC. Wherein the Kullback-Leibler Divergence is adopted to convexify the modified swing equation after integrating the step-change power. Further, to avoid the complicated differential equations, we equivalently reformulate the duration limits of DC voltage deviation into the HVDC decreasing power ramping rates, which participate in the system primary frequency response. Finally, the new steady-state operation level of HVDC is involved with the secondary frequency response. As a result, an improved three-level algorithm is developed to solve the model, wherein the instant step-change, primary, and secondary frequency response are coordinated together. After applying the proposed frequency response scheme on the test system, the EPFR is validated to effectively provide the most instantaneous supports when faced with bulk power loss due to extreme contingencies, and the resilience is ensured within acceptable expenditures.

Jiang, Sufan↗

Towards Improved Decision Making for the Smarter Grid: Geomagnetic Disturbance Implicit Modeling Uncertainty Quantification

Geomagnetic disturbances can greatly disrupt the power grid operation. This is caused by low-frequency changes in the earth’s magnetic field, which upon interaction with the deep earth conductivity induces a changing electric field at the earth’s surface. This in turn induces quasi-direct currents which have the potential to cause protective devices to operate, widespread damage to high-voltage transformers, or voltage collapse due to induced reactive power losses. While these impacts have been known since the 1940s, only recently have standards for GMD response been implemented. Because these standards are heavily based on models, it is important to understand when it is appropriate to make certain modeling assumptions. In this work, implicit modeling uncertainty is quantified for the purpose of enhanced decision making for disturbance impact mitigation. Considering electromagnetic models, modeling assumptions of non-uniform grounding, imbalanced operation, transformer saturation, and geomagnetically induced currents, voltage estimation values are analyzed. Statistical characteristics of modeling uncertainty are obtained by analysis of synthetically generated data. Results statistically characterize geomagnetic disturbances modeling uncertainty, providing an important tool for impact mitigation.

grid analysis↗

Developing VSC-HVDC Oscillation Damping Control Constraints in Unit Commitment

High-voltage direct current (HVDC) systems within the existing power grids will play a pivotal role in enabling high share of renewable power integration and transportation electrification. There is a need for transmission planning models to accurately capture the impact of VSC-HVDC oscillation damping control on the system planning and model the constraints in the security constrained unit commitment (SCUC) problem. In this paper, the SCUC problem in a hybrid DC-AC grid considering damping on electromechanical inter-area oscillation is studied. An electromechanical oscillation-driven transmission capability constraints are derived from system swing equation and incorporated into the SCUC. Multiple system damping control scenarios are set based on the extracted plausible bounds of damping coefficient and inertia constant to linearize the nonlinear expressions. The SCUC problem with proposed constraints is tested on the Reliability Test System Grid Modernization Lab Consortium (RTS-GMLC) via PLEXOS. The impact of the proposed constraints on regional generation, inertia, power flow, annual system cost, and renewable energy curtailment are fully assessed.

damping control↗

Power System Recovery Coordinated with (Non-)Black-Start Generators

Power restoration is an urgent task after a black-out, and recovery efficiency is critical when quantifying system resilience. Multiple elements should be considered to restore the power system quickly and safely. This paper proposes a recovery model to solve a direct-current optimal power flow (DCOPF) based on mixed-integer linear programming (MILP). Since most of the generators cannot start independently, the interaction between black-start (BS) and non-black-start (NBS) generators must be modeled appropriately. The energization status of the NBS is coordinated with the recovery status of transmission lines, and both of them are modeled as binary variables. Also, only after an NBS unit receives the cranking power through connected transmission lines, will it be allowed to participate in the following system dispatch. The amount of cranking power is estimated as a fixed proportion to the maximum generation capacity. The proposed model is validated on several test systems, as well as a 1393-bus representation system of the Puerto Rican electric power grid. Test results demonstrate how the recovery of NBS units and damaged transmission lines can be optimized, resulting in an efficient and well-coordinated recovery procedure.

Zhao, Meng↗

Advanced Models and Fast Simulation Algorithms for MARS Plants

With the successful commercialization of modular multilevel converters (MMC) and rapid increase in photovoltaic (PV) penetration and energy storage systems (ESS), one of the research areas being explored dynamically is integration of PV systems and ESS systems to MMCs. On this front, an integrated development of PV plants, ESS, and alternating- and direct-current (ac/dc) systems through Multi-Port Autonomous Reconfigurable Solar (MARS) plant is proposed and being researched upon. However, simulation of MARS systems on traditional existing software takes very long time (order of days) due to the presence of a large number of states and non-linear devices. Therefore, development of fast high fidelity models is of paramount importance to test the hardware design, control design and planning of power system expansions. In this context, two research objectives are addressed in this paper: firstly, an ultra fast single- or multi- CPU simulation algorithm to simulate the MARS system based on state-space models, hybrid discretization algorithm with a relaxation technique that reduces the imposed computational burden and a multi-rate method is presented. Secondly, a reduced order model of MARS is also presented. Both the developed techniques are validated with respect to reference PSCAD/EMTDC model.

Marthi, Phani Ratna Vanamali↗

Dynamic Frequency Regulation Improvement in Hydropower-Hybrid System using Variational Mode Decomposition

Providing frequency response, especially fast frequency response such as Red D in the Pennsylvania-New Jersey-Maryland Interconnection (PJM) market, is challenging for many generation plants to deliver on their own. If they have adequate flexibility, hydropower plants are typically able to provide slower regulation support (e.g., Reg A in PJM), but do not respond fast enough to provide Reg D. The ability to provide Reg D would improve their revenue because this service is typically more valuable. This work presents a control approach to use hydropower, battery, and ultracapacitor systems to provide fast regulation in a way that uses the response contribution of each asset. In particular, the proposed control architecture applies a variational mode decomposition (VMD) technique on the incoming Reg D signal to extract multiple dynamic-regulation components with non-overlapping frequencies. With the response-speed dependent alignment, these regulation components are fed to the hydrogenator and hybrid energy storage system (HESS). The paper evaluates the proposed approach on a direct-current (DC)-coupled active system by computing several performance measures and analyzing sensitivity based on HESS component proportional capacities. The results reveal that the proposed VMD-based signal conditioning performs well and that optimizing the sizing of the battery and ultracapacitor components further enhances performance.

13 HYDRO ENERGY↗

Coordinated Control of Natural and Sub-Synchronous Oscillations via HVDC Links in Great Britain Power System

Conventional power oscillation damping (POD) controllers have been designed to be effective in damping either inter-area low-frequency oscillations (LFO) or sub-synchronous oscillations (SSO). For those POD controls, model-based control design method has been widely implemented with wide-area feedback signals from phasor measurement units (PMU). However, the model accuracy of a large realistic power system can hardly be guaranteed, which will finally impact the POD damping performance. In this paper, a measurement-based method is proposed for POD design using High Voltage Direct Current links (HVDC) to realize the coordinated control of both LFO and SSO. For each type of oscillations, a band-pass filter is added to avoid the interactions between different modes. Case studies are carried out on the Great Britain 36-bus power system model with multiple HVDC links in DIgSILENT/PowerFactory. Simulation results demonstrate that the proposed PODs are effective in damping inter-area LFO and SSO simultaneously.

Zhao, Yi↗

Enhancing Short-Term Flexibility through Characterization of HVDC Transmission Systems

Efficient power grid operation hinges on maintaining safety and reliability through adaptable system flexibility standards. However, in a future power grid characterized by extensive renewable energy integration, conventional system flexibility and predetermined requirements may falter under extreme conditions. This paper addresses the formidable challenge of sustaining secure and dependable power grid operations under these circumstances, emphasizing the role of controllable high voltage direct current (HVdc) transmission systems in amplifying overall system flexibility and tackling operational complexities. To quantitatively assess short-term flexibility and its associated economic benefits from HVdc within specific regions, we propose a Power Flow Distribution Factors (PTDFs) based approach. This methodology takes into account both dispatchable generators and HVdc systems, pinpointing their contributions. Through an analysis of the Western Electricity Coordinating Council (WECC) system, we demonstrate the practical application of this approach to scrutinize the impacts of existing and future HVdc lines.

Operational Flexibility, Multi-terminal HVdc, tran↗

High efficiency compact microwave sources using electrostatic potential depression

In this article, we report theoretical and design studies on the application of an electrostatic potential depression (EPD) on two types of traditional microwave sources, the klystron and the inductive output tube (IOT), both operating in the UHF band. Additionally, the EPD is implemented by a section of the metallic beam pipe on which a direct current (dc) negative high voltage is applied. Inside the EPD section, the modulated electron beam develops into bunches over a very short longitudinal distance, indicating a possible design approach for a compact device. With the application of an EPD, the peak value of the first harmonic current in a microwave tube can be further increased compared to that in a conventional design, suggesting higher circuit efficiency. As the electron beam leaves the EPD section, the reacceleration of the beam provides a longitudinal cooling effect. With the addition of an EPD, circuit power extraction efficiency above 80% is achieved in both the modified design of the IOT and the novel conceptual circuit design of the klystron.

42 ENGINEERING↗

A Neural Network-Based Power Mismatch Elimination Strategy for Integrated Solar and ESS AC/DC Systems (MARS)

The multiport autonomous reconfigurable solar power plant (MARS) is a promising concept for the integration of photovoltaic (PV) and energy storage system (ESS) to the transmission ac grid and a high-voltage direct current (HVdc) link. The presence of PV and ESS in each arm of the MARS results in uneven distribution of active power among different submodules (SMs), thereby leading to unbalanced SM capacitor voltages and potentially compromising the system stability. Moreover, in the case of partial shadings, shaded PV SMs will suffer from decreased power injections causing power mismatch in the MARS system. To address this issue, a neural-network-based power mismatch elimination (NNPME) strategy is proposed in this article. The proposed NNPME strategy optimizes ESS usage and leverages both dc and ac circulating currents to facilitate power transfer among the SMs, arms, and phases of the MARS system. Simulation and control hardware-in-the-loop (cHIL) experiments demonstrate the effectiveness of the proposed NNPME strategy. Compared with the traditional approaches, the proposed NNPME strategy can significantly enhance system efficiency and ensure stable and continuous operation, even in the presence of uneven power distribution within the MARS system.