Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnostics engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

ATP biosensor reveals microbial energetic dynamics and facilitates bioproduction

Adenosine-5’-triphosphate (ATP), the primary energy currency in cellular processes, drives metabolic activities and biosynthesis. Despite its importance, understanding intracellular ATP dynamics’ impact on bioproduction and exploiting it for enhanced bioproduction remains largely unexplored. Here, we harness an ATP biosensor to dissect ATP dynamics across different growth phases and carbon sources in multiple microbial strains. We find transient ATP accumulations during the transition from exponential to stationary growth phases in various conditions, coinciding with fatty acid (FA) and polyhydroxyalkanoate (PHA) production in Escherichia coli and Pseudomonas putida, respectively. We identify carbon sources (acetate for E. coli, oleate for P. putida) that elevate steady-state ATP levels and boost FA and PHA production. Moreover, we employ ATP dynamics as a diagnostic tool to assess metabolic burden, revealing bottlenecks that limit limonene bioproduction. Our results not only elucidate the relationship between ATP dynamics and bioproduction but also showcase its value in enhancing bioproduction in various microbial species.

59 BASIC BIOLOGICAL SCIENCES↗

Fast switching magnet for heavy ion beam separation

This paper presents the design for a switching magnet capable of deflecting 6.5 MeV/u heavy-ion beams with mass-to-charge ratio of 7 by 10 degrees. This magnet can produce variable flat-top pulses from 1 to 30 ms with rise and fall times of less than 0.5 ms at a variable duty cycle of 3–91% into a heavily inductive load. The magnet has a laminated, iron dominated, H-shaped core. Directly-cooled copper pancake coils energize the magnet. We present the magnet design considerations, including the results of extensive computer modeling. Finally, we also present the conceptual engineering design and the studies of magnet yoke fabrication.

47 OTHER INSTRUMENTATION↗

Tracker Fits for shot 1s1674

Gas gun shock-to-detonation experiments provide data for calibrating HE burn models. At LANL the principal diagnostic is a magnetic gauge package that provides data on the lead shock trajectory, which is used to determine the run-distance to detonation, and the lead shock speed with run distance, which together with jump-off velocity of the velocity gauges determines Hugoniot locus points for the reactants.

42 ENGINEERING↗

IDAES-PSE 2.7.0 Release

The Institute for the Design of Advanced Energy Systems (IDAES) Integrated Platform is a versatile computational environment offering extensive process systems engineering (PSE) capabilities for optimizing the design and operation of complex, interacting technologies and systems. IDAES enables users to efficiently search vast, complex design spaces to discover the lowest cost solutions while supporting the full process modeling lifecycle, from conceptual design to dynamic optimization and control. The extensible, open platform empowers users to create models of novel processes and rapidly develop custom analyses, workflows, and end-user applications. IDAES-PSE 2.7.0 Release Highlights New features: AutoScaler and CustomScalerBase classes: Such tools are the core of the new scaling framework being implemented in IDAES. Wider adoption of scaling tools among users will result in quicker and more robust model solutions. Scaler for equilibrium reactor and saponification properties: These scaler models are examples to follow for how to use the new scaling tools. ONNX Surrogate support from Optimization & Machine Learning Toolkit (OMLT): ONNX is an open standard format to save and load ML/AI models that is widely supported by all major frameworks. This capability makes it easier for IDAES users to create surrogate models and use them without having to support each framework individually. 1D Membrane Model for CO2 Capture and Utilization: Supports ongoing efforts for modeling and optimizing polymer membrane processes for CO2 capture and conversion into formic acid. StreamScaler unit model: Unrelated to the CustomScalerBase, this unit model allows a stream’s extensive variables to be scaled by a fixed factor. This allows streams being processed by multiple units in parallel to be scaled down to unit scale and scaled back up to process scale. Bug fixes or improvements: Scaling, EoS, Diagnostics tool, Modular Properties, tests & documentation Deprecations: Old Cubic EoS

AS↗

Automated bubble analysis of high-speed subcooled flow boiling images using U-net transfer learning and global optical flow

Capturing and analyzing the bubble dynamics is crucial to improving the understanding of boiling heat transfer mechanisms and predicting boiling heat transfer coefficient and boiling crisis. High speed video (HSV) imaging has been used for decades towards this end. Still, there is no universal approach to quantitatively analyze bubble dynamics from HSV images. In this study, we propose a data-driven post-processing approach to segment, track, and identify wall-attached vapor bubbles from HSV images of the boiling process in subcooled flow conditions. Firstly, we employ a transfer learning framework with a U-Net-based convolution neural network (CNN) architecture to detect and segment bubbles in HSV images of diverse contrast and surface texture using very little data (e.g., 10 images) for training. Then, we evaluate the trained CNN model with 100 ground-truth images, and the validation results show that the model accuracy and precision in detecting the optical footprint of bubbles are higher than 90%. Finally, we suggest a criterion to identify a condensing bubble based on the divergence of the bubble displacement, which is calculated from sequential segmented bubble images using a global optical flow code. Using this combination of machine learning and optical flow, we can identify nucleation sites and track the growth of bubbles nucleating at each site to quantify nucleation site density, nucleation frequency, and other fundamental boiling parameters. The proposed system is validated using results obtained on a special heater, which enables both infrared (IR) thermometry and HSV imaging on a metallic surface. We compare the fundamental boiling parameters obtained by the two different diagnostics. The results show good agreement. In conclusion, the difference between the measurements of nucleation site density, averaged nucleation frequency, and averaged growth time performed with the two techniques is always within ± 20% and mostly ± 10% of the values measured with IR thermometry.

42 ENGINEERING↗

Investigating the origin of the far-field reflection interference fringe (RIF) of microdroplets

We show that the reflection interference fringe (RIF) is formed on a screen far away from the microdroplets placed on a prism-based substrate, which have low contact angles and thin droplet heights, caused by the dual convex–concave profile of the droplet, not a pure convex profile. The geometric formulation shows that the interference fringes are caused by the optical path difference when the reflected rays from the upper convex profile at the droplet–air interface interfere with reflection from the lower concave profile at oblique angles lower than the critical angle. Analytic solutions are obtained for the droplet height and the contact angle out of the fringe number and the fringe radius in RIF from the geometric formulation. Furthermore, the ray tracing simulation is conducted using the custom-designed code. The geometric formulation and the ray tracing show excellent agreement with the experimental observation in the relation between the droplet height and the fringe number and the relation between the contact angle and the fringe radius. This study is remarkable as the droplet's dual profile cannot be easily observed with the existing techniques. However, the RIF technique can effectively verify the existence of a dual profile of the microdroplets in a simple setup. In this work, the RIF technique is successfully developed as a new optical diagnostic technique to determine the microdroplet features, such as the dual profile, the height, the contact angle, the inflection point, and the precursor film thickness, by simply measuring the RIF patterns on the far-field screen.

42 ENGINEERING↗

Completion document for MRT 8824 - Upgrade NIF’s gaseous radiochemistry diagnostics (RAGS) to support weapons science

This milestone highlights the successful upgrade and deployment of the Radiochemical Analysis of Gaseous Samples (RAGS) system, which delivers high-quality measurements (<20% uncertainty) of activated gaseous species from NIF implosions. These measurements are critical for supporting Stockpile Stewardship Program (SSP) relevant platforms, including LANL’s Double Shell and LLNL’s Pushered Single Shell campaigns. The RAGS diagnostic technique enables analysis of short-range mixing in implosions using high-Z shells, which are otherwise inaccessible to conventional x-ray diagnostic methods. By facilitating the investigation of high-Z material mixing into fusion burn, this system provides essential data for quantifying and interpreting results in high-energy density (HED) experiments. This report details the physics motivation, diagnostic fundamentals, planned and enacted upgrade work, and the quantification of uncertainty for the upgraded system.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Blast Effects on Buildings (Final Report)

Lawrence Livermore National Laboratory (LLNL) has conservatively reduced the explosive safety standards suggested by the Small Quantities in Research Laboratories (SQRL) program testing by 60%. For this reason, further research into the detailed effects of small amounts of explosives in typically constructed rooms is needed in order to improve their factor of safety. The team was tasked with designing an experiment to investigate the effect of different variables on drywall under explosive blasts. In order to meet this objective, the team conducted a comprehensive literature review to gain an understanding of industry-standard construction practices and review previous tests conducted by the Army corp of engineers. Since the team used PBXN-5 rather than C4, as in SQRL, an initial shot was conducted to compare damage levels. From those results and the physical constraints of the testing chamber, the team redesigned multiple single-panel drywall frames to capture the entirety of the incurred damage. Proposed designs were narrowed down using a decision matrix. From the study of previous tests and literature review, variables were chosen that the team hypothesized to have an impact on drywall strength. The variables that were tested were chosen from the results of that work and specific variables the sponsor was interested in, and they were paint, humidity/moisture content, and explosive positioning relative to the studs. Detailed plans were made for each variable according to what conditions the team wanted to investigate. For humidity, this involved testing low, ambient, and high conditions by treating the panels in a chamber. Preliminary shots were performed to test the structural integrity of the frame and streamline the test diagnostics which involved a high-speed camera placed behind the drywall, outside of the chamber, and a pressure probe placed behind the drywall, inside the chamber. Once the instrumentation, diagnostics, and frame design were finalized, a quantitative damage criteria matrix was created to categorize the results of the main shot series. In conjunction with evidence from the high-speed video, the achieved damage levels indicate that high moisture content drywall is better able to withstand explosive blasts. Larger stud damage and lower drywall damage occurred when the explosive was located directly in front of a stud. Paint had no noticeable impact on strength. Ultimately, the team conducted a total of 17 tests, leaving the door open for future in-depth research into the impact of humidity.

36 MATERIALS SCIENCE↗

A Systems Engineering Analysis of National Ignition Facility Industrial Controls Systems and Safety Interlock Systems Remote Input/Output Networking Migration from ControlNet to EtherNet/IP

The ControlNet industrial communications protocol and modules used in the Industrial Control System (ICS) and Safety Interlock System (SIS) at the National Ignition Facility (NIF) are no longer necessary and the ICS and SIS would be better served by migrating the communications structure to use EtherNet/Industrial Protocol (IP) and EtherNet bridge modules instead. By the admission of the vendor of ControlNet hardware, Rockwell Automation, in literature by Bill Petro [1], “Moving forward, customers will be able to optimize their asset utilization better using EtherNet/IP protocol than with ControlNet.” The NIF is one of the key elements of the Inertial Confinement Fusion (ICF) program at Lawrence Livermore National Laboratory (LLNL), a federally funded research and development center (FFRDC). The NIF contains the systems and provides the operational capacity to perform ICF, high energy density (HED), and discovery science experiments utilizing 192 individual beamlines, a host of diagnostics, and all the industrial systems required to facilitate these beamlines and diagnostics. The industrial systems are governed by the ICS and SIS, with the ICS providing control and the SIS providing monitoring and permissives. Construction on the NIF began in 1997 and was certified complete in 2009 and, as a result, the ICS and SIS were developed during this time using the tools that were available then. This includes the communications structure and protocols for these systems, much of which was, and still is, ControlNet. ControlNet, particularly during the time that the ICS and SIS were being built, has several attractive features. ControlNet hardware is exclusive to Rockwell Automation, which was the automation hardware chosen for the ICS and SIS. One feature that could be considered an advantage or a disadvantage depending on the communication needs of the system is that ControlNet also utilizes no active network components, excluding repeaters which are not always necessary. According to the architect of the ICS system at the NIF, Gordon Lau, one of the most attractive features of the ControlNet protocol during development of the ICS and SIS was that it is deterministic, providing timing of data transfer that is executed exactly as it is defined by the developer.

42 ENGINEERING↗

225 Ac/ 213 Bi Generator Based on Millifluidics Controlled Electrodeposition

Radioisotopes provide both diagnostic tools and therapeutic treatments for cancer and other diseases. In the US, millions of radioisotope doses are given to patients per year. Radiopharmaceutical generators are widely used to provide such short-lived medical radioisotopes in a clinical setting. These generators work by exploiting chemical differences in a parent/daughter isotope relationship. Actinium-225 (half-life 10 d) is used to provide clinically useful amounts of daughter isotopes 213 Bi (46 m). An integrated millifluidic 225 Ac/ 213 Bi radiopharmaceutical generator device was engineered to produce 213 Bi labeled biomolecules. Using recent LANL successes in additive manufacturing of small-scale fluidic devices, a disposable device was developed that integrates three steps for the production of 213 Bi labeled antibodies: 1) 213 Bi separation from 225 Ac parent, 2) 213 Bi antibody labeling, and 3) purification of the labelled antibody.

213Bi↗

Deep learning based x-ray spectrometer for high repetition rate characterization of betatron radiation

Betatron radiation produced from a laser-wakefield accelerator is a broadband, hard x-ray (>1 keV) source that has been used in a variety of applications in medicine, engineering, and fundamental science. Further development and optimization of stable, high repetition rate (HRR) (>1 Hz) betatron sources will provide a means to extend their application base to include single-shot dynamical measurements of ultrafast processes or dense materials. Recent advances in laser technology used in such experiments have enabled increases in shot-rate and system stability, providing improved statistical analysis and detailed parameter scans. However, unique challenges exist at high repetition rate, where data throughput and source optimization are now limited by diagnostic acquisition rates and analysis. Here, we present the development of a machine-learning algorithm for the real-time analysis of betatron radiation. We report on the fielding of this deep learning algorithm for online source characterization at the Institut National de la Recherche Scientifique's Advanced Laser Light Source. By fine-tuning an algorithm originally trained on a fully synthetic dataset using a subset of experimental data, the algorithm can predict the betatron critical energy with a percent error of 7.2 % with a reconstruction time of 1.5 ms, providing a valuable tool for real-time, multi-objective optimization at HRR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Placing High-redshift Quasars in Perspective: A Catalog of Spectroscopic Properties from the Gemini Near Infrared Spectrograph–Distant Quasar Survey

Here, we present spectroscopic measurements for 226 sources from the Gemini Near Infrared Spectrograph–Distant Quasar Survey (GNIRS-DQS). Being the largest uniform, homogeneous survey of its kind, it represents a flux-limited sample ($m_i$ ≲ 19.0 mag, H ≲ 16.5 mag) of Sloan Digital Sky Survey (SDSS) quasars at 1.5 ≲ $\mathcal{z}$ ≲ 3.5 with a monochromatic luminosity ($\lambda {L}_{\lambda }$) at 5100 Å in the range of 10 44 –10 46 erg s –1 . A combination of the GNIRS and SDSS spectra covers principal quasar diagnostic features, chiefly the C IV λ1549, Mg ii λλ2798, 2803, Hβ λ4861, and [O III ] λλ4959, 5007 emission lines, in each source. The spectral inventory will be utilized primarily to develop prescriptions for obtaining more accurate and precise redshifts, black hole masses, and accretion rates for all quasars. Additionally, the measurements will facilitate an understanding of the dependence of rest-frame ultraviolet–optical spectral properties of quasars on redshift, luminosity, and Eddington ratio, and test whether the physical properties of the quasar central engine evolve over cosmic time.

79 ASTRONOMY AND ASTROPHYSICS↗

Sandia National Laboratories FY21 Progress Report

The Energetic Neutrons campaign led by Sandia National Laboratories (SNL) had a successful year testing electronic devices and printed circuit boards (PCBs) under 14 MeV neutron irradiation at OMEGA. During FY21 Sandia’s Neutron Effects Diagnostics (NEDs) and data acquisition systems were upgraded to test novel commercial off-the-shelf and Sandia-fabricated electronic components that support SNL’s National Security mission. The upgrades to the Sandia platform consisted of new cable chains, sample mount fixtures and a new fiber optics platform for testing optoelectronic devices.

42 ENGINEERING↗

IDAES-PSE 2.4.0 Release

The Institute for the Design of Advanced Energy Systems (IDAES) Integrated Platform is a versatile computational environment offering extensive process systems engineering (PSE) capabilities for optimizing the design and operation of complex, interacting technologies and systems. IDAES enables users to efficiently search vast, complex design spaces to discover the lowest cost, most environmentally sustainable solutions while supporting the full process modeling lifecycle, from conceptual design to dynamic optimization and control. The extensible, open platform empowers users to create models of novel processes and rapidly develop custom analyses, workflows, and end-user applications.. Deprecations • Convergence Analysis tool (idaes/core/util/convergence): deprecated in favor of new Parameter Sweep tools. To be removed in v3.0.0. New Beta Capabilities • Parameter Sweep Tool (idaes.core.util.parameter_sweep) o A new API for defining and performing parameter sweep studies on IDAES models has been developed • Diagnostics Tools (idaes.core.util.model_diagnostics) o New methods for identifying duplicate variables and constraints have been added to the diagnostics toolbox o New tools for detecting ill conditioning in Jacobians have been developed and are available in the model_diagnostics module. These provide alternatives to the existing DegeneracyHunter toolbox, and will eventually be merged with this capability, but initial working versions have been provided as beta capabilities for interested users o IpoptConvergenceAnalysis (replaces deprecated Convergence Analysis tool):  A new tool for performing convergence analysis studies that leverages the new Parameter Sweep tools has been developed. This tool allows users to define the input parameters to their model and sampling methods for these (leveraging Pysmo's sampling tools) and to then solve their model across the sampled domains and return a summary of the solver performance (IPOPT only) Improved Models • Thickener model (idaes.models.unit_models.solid_liquid.thickener) o Improved model to include predictive correlations for unit sizing based on settling velocity measurements (steady-state only) • Modular Property Packages o Added general support for calculating critical properties of mixtures using defined Equation of State modules. New API defined for Equation of State modules in order to define the necessary constraints for calculating critical properties (most EoS modules DO NOT support calculation of critical properties (yet)) o Added new methods to Cubic Equation of State module to support calculation of critical properties

DiagnosticsToolbox↗

Sensor impact evaluation and verification for fault detection and diagnostics in building energy systems: A review

Sensors are the key information source for fault detection and diagnostics (FDD) in buildings. However, sensors are often not properly designed, installed, calibrated, located, and maintained, which negatively impacts FDD performance. Several sensor-related FDD topics have been widely studied, covering a wide range of fault types and applications. However, it is difficult to get a clear picture of the technical development of sensor-related topics in FDD. A systematic review of sensor topics is needed to summarize the existing research in a logical way, draw conclusions on the current development, and predict the future development of sensors in building FDD. To address this gap, we conducted a comprehensive literature review of more than 100 FDD-sensor-related papers. In this article, we subdivide the FDD tasks into building-level, system-level, and component-level FDD, and review sensor-related topics in each category. Our major conclusions are: (a) current data-driven FDD research focuses more on FDD algorithms than sensors, (b) sensor “hardware” research topics are less studied than sensor “software” topics, (c) very few papers focus on sensor engineering as an integral aspect of FDD development, and (d) some important sensor topics, such as sensor cost-effectiveness and sensor schema/layout/location, are not well studied. Finally, we discuss the need for a systematic framework of FDD sensors and models to integrate sensor design/selection, sensor data analysis/mining, feature selection, physics-based or data-driven algorithm development, sensor fault detection, sensor calibration, and sensor maintenance. Finally, expert interviews are conducted to validate the above findings and conclusions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optics-on-a-chip for ultrafast manipulation of 350-MHz hard x-ray pulses

Microelectromechanical systems (MEMS) are miniature devices integrated into a vast range of industrial and consumer applications. Optical MEMS are developed for dynamic spatiotemporal control in lightwave manipulation and communication as modulators, switches, multiplexers, spectrometer, etc. However, they have not been shown to function similarly in sub-nm wavelength regimes, namely, with hard x-rays, as high-brilliance pulsed x-rays have proven powerful for addressing challenges in time-domain science, from energy conversion to neurobiological control. While desirable temporal properties of x-ray pulses can be enhanced by optics, conventional x-ray optics are inherently massive in size, hence, never dynamic. We demonstrate highly ultrafast x-ray optics-on-a-chip based on MEMS capable of modulating hard x-ray pulses exceeding 350 MHz, 10 3 × higher than any other mechanical modulator, with a pulse purity >10 6 without compromising the spectral brilliance. Moreover, the timing characteristics of the devices can be tuned on-the-fly to deliver optimal pulse properties to create a host of dynamic x-ray instruments and applications, impossible with traditional optics of 10 9 × bulkier and more massive. The advent of the ultrafast optics-on-a-chip heralds a new paradigm of x-ray photonics, time-domain science, and accelerator diagnostics, especially at not only the future-generation light sources that offer coherent and high-frequency pulses but also lab-based facilities that normally do not offer timing structures.

42 ENGINEERING↗

Small Windowed PDV Slab Shot Verification

Windowed PDV probes are used as a time of arrival diagnostic where conventional PDV measurements cannot be made with accuracy i.e., measurements where the surface measured is bare HE or the surface measured does not provide quality optical return for PDV directly. Often hydro experiments require that these diagnostics be minimally invasive, so their installation does not negatively impact the device performance or the overall experiments goals. In this report we build 3 mm diameter windowed probes and show that they give an error that is still within the error of piezo pins.

13 HYDRO ENERGY↗

Developments and Challenges in the Design of the ITER DRGA

We report the ITER Diagnostic Residual Gas Analyzer (DRGA) will measure the distribution of gas species, i.e., deuterium (D), tritium (T), and impurities, in the divertor exhaust stream and in the plasma periphery, with time resolution relevant to fusion plasma–wall particle dynamics. The uniqueness of the DRGA, over previous implementations of plasma dynamics residual gas analysis, is an integrated approach, combining mass and low-temperature plasma-activated optical spectroscopy, in a differentially pumped analysis station. A further unique feature of the ITER divertor-specific DRGA is an ~8-m separation of the analysis station from the sampled pumping duct, while still maintaining a ~1-s response time for hydrogen isotopic concentrations. ITER DRGA final design activities are strongly benefiting from testing of prototypical DRGA components and methods on present fusion devices, most currently on JET and W7-X. DRGA systems are implemented on both these devices and include sensors (and pumping methods) that are directly relevant to the ITER DRGA design. The recent JET-DTE2 campaign has provided the first experience on operating the combined ITER DRGA sensors with D-T plasmas. While enhancing system design for ITER, this experience on operating devices has also revealed additional engineering challenges, which further guide the continuing final design project. Meanwhile, the recent determination that the ITER DRGA, with slight optimization, will resolve the helium isotopes well enough to support an ITER pre-DT, He-3-based heating scheme, has greatly increased ITER Research Program interest in the DRGA and its implementation well ahead of the DT phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗