Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Slot-Antenna/Permanent-Magnet Device for Generating Plasma

A device that includes a rectangular-waveguide/slot-antenna structure and permanent magnets has been devised as a means of generating a substantially uniform plasma over a relatively large area, using relatively low input power and a low gas flow rate. The device utilizes electron cyclotron resonance (ECR) excited by microwave power to efficiently generate plasma in a manner that is completely electrodeless in the sense that, in principle, there is no electrical contact between the plasma and the antenna. Plasmas generated by devices like this one are suitable for use as sources of ions and/or electrons for diverse material-processing applications (e.g., etching or deposition) and for ion thrusters. The absence of plasma/electrode contact essentially prevents plasma-induced erosion of the antenna, thereby also helping to minimize contamination of the plasma and of objects exposed to the plasma. Consequently, the operational lifetime of the rectangular-waveguide/ slot-antenna structure is long and the lifetime of the plasma source is limited by the lifetime of the associated charged-particle-extraction grid (if used) or the lifetime of the microwave power source. The device includes a series of matched radiating slot pairs that are distributed along the length of a plasma-source discharge chamber (see figure). This arrangement enables the production of plasma in a distributed fashion, thereby giving rise to a uniform plasma profile. A uniform plasma profile is necessary for uniformity in any electron- or ion-extraction electrostatic optics. The slotted configuration of the waveguide/ antenna structure makes the device scalable to larger areas and higher powers. All that is needed for scaling up is the attachment of additional matched radiating slots along the length of the discharge chamber. If it is desired to make the power per slot remain constant in scaling up, then the input microwave power must be increased accordingly. Unlike in prior ECR microwave plasma-generating devices, there is no need for an insulating window on the antenna. Such windows are sources of contamination and gradually become ineffective as they become coated with erosion products over time. These characteristics relegate prior ECR microwave plasma-generating devices to non-ion beam, non-deposition plasma applications. In contrast, the lack of need for an insulating window in the present device makes it possible to use the device in both ion-beam (including deposition) and electron-beam applications. The device is designed so that ECR takes place above each slot and the gradient of the magnetic field at each slot is enough to prevent backflow of plasma.

Foster, John E.↗

RFID and Memory Devices Fabricated Integrally on Substrates

Electronic identification devices containing radio-frequency identification (RFID) circuits and antennas would be fabricated integrally with the objects to be identified, according to a proposal. That is to say, the objects to be identified would serve as substrates for the deposition and patterning of the materials of the devices used to identify them, and each identification device would be bonded to the identified object at the molecular level. Vacuum arc vapor deposition (VAVD) is the NASA derived process for depositing layers of material on the substrate. This proposal stands in contrast to the current practice of fabricating RFID and/or memory devices as wafer-based, self-contained integrated-circuit chips that are subsequently embedded in or attached to plastic cards to make smart account-information cards and identification badges. If one relies on such a chip to store data on the history of an object to be tracked and the chip falls off or out of the object, then one loses both the historical data and the means to track the object and verify its identity electronically. Also, in contrast is the manufacturing philosophy in use today to make many memory devices. Today s methods involve many subtractive processes such as etching. This proposal only uses additive methods, building RFID and memory devices from the substrate up in thin layers. VAVD is capable of spraying silicon, copper, and other materials commonly used in electronic devices. The VAVD process sprays most metals and some ceramics. The material being sprayed has a very strong bond with the substrate, whether that substrate is metal, ceramic, or even wood, rock, glass, PVC, or paper. An object to be tagged with an identification device according to the proposal must be compatible with a vacuum deposition process. Temperature is seldom an issue as the substrate rarely reaches 150 F (66 C) during the deposition process. A portion of the surface of the object would be designated as a substrate for the deposition of the device. By use of a vacuum arc vapor deposition apparatus, a thin electrically insulating film would first be deposited on the substrate. Subsequent layers of materials would then be deposited and patterned by use of known integrated-circuit fabrication techniques. The total thickness of the deposited layers could be much less than the 100- m thickness of the thinnest state-of-the-art self-contained microchips. Such a thin deposit could be readily concealed by simply painting over it. Both large vacuum chambers for production runs and portable hand-held devices for in situ applications are available.

Schramm, Harry F.↗

Portable Intravenous Fluid Production Device For Ground Use Project

Several medical conditions require the administration of intravenous (IV) fluids,but limitations of mass, volume, shelf-life, transportation, and local resources can restrict the availability of these important fluids. Such limitations are expected in long-duration space exploration missions and in remote or austere places on Earth. This design uses regular drinking water that is pumped through two filters to produce, in minutes, sterile, ultrapure water that meets the stringent quality standards of the United States Pharmacopeia for Water for Injection (Total Bacteria, Conductivity, Endo - toxins, Total Organic Carbon). The device weighs 2.2 lb (1 kg) and is 10 in. long, 5 in. wide, and 3 in. high (≈25, 13, and 7.5 cm, respectively) in its storage configuration. This handheld device produces one liter of medical-grade water in 21 minutes. Total production capacity for this innovation is expected to be in the hundreds of liters. The device contains one battery powered electric mini-pump. Alternatively, a manually powered pump can be attached and used. Drinking water enters the device from a source water bag, flows through two filters, and final sterile production water exits into a sealed, medical-grade collection bag. The collection bag contains pre-placed crystalline salts to mix with product water to form isotonic intravenous medical solutions. Alternatively, a hypertonic salt solution can be injected into a filled bag. The filled collection bag is detached from the device and is ready for use or storage. This device currently contains one collection bag, but a manifold of several pre-attached bags or replacement of single collection bags under sterile needle technique is possible for the production of multiple liters. The entire system will be flushed, sealed, and radiation-sterilized. Operation of the device is easy and requires minimal training. Drinking water is placed into the collection bag. Inline stopcock flow valves at the source and collection bags are opened, and the mini-pump is turned on by a switch to begin fluid flow. When the collection bag is completely filled with the medical- grade water, the pump can be turned off. The pump is designed so it cannot pump air, and overfilling of the collection bag with fluid is avoided by placing an equal amount of water in the source bag. Backflow is avoided by inline check valves. The filled collection bag is disconnected from its tubing and is ready for use. The source bag can be refilled for production of multiple liters, or the source bag can be replaced with an input tube that can be placed in a larger potable water source if the device is attended. The device functions in all orientations independent of any gravity fields. In addition to creating IV fluids, the device produces medical-grade water, which can be used for mixing with medications for injection, reconstituting freeze-dried blood products for injection, or for wound hydration or irrigation. Potential worldwide use is expected with medical activities in environments that have limited resources, storage, or resupply such as in military field operations, humanitarian relief efforts, submarines, commercial cruise ships, etc.

Technology Portfolio System↗

A Multi-Faceted Approach to Demonstrating Multi-Functional Integrated Medical Devices to Advance Earth-Independent Medical Operations

INTRODUCTION TO MIM DEVICES Multi-functional Integrated Medical (MIM) devices conveniently incorporate multiple medical system capabilities within one device. The NASA Exploration Medical Integrated Product Team (XM-IPT) sponsored a market survey and trade study which identified the Tempus ProTM and the LifeBot 10® as the MIM devices that best met the evaluation criteria of the trade study. The Tempus ProTM (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) and LifeBot 10® (LifeBot Health, Chicago, IL) both provide vital sign measurements such as blood pressure, electrocardiograms, heart rate, end tidal CO2, respiration rate, pulse oximetry and temperature along with ultrasound imaging. A video laryngoscopy capability is unique to the Tempus ProTM, while the LifeBot 10® supports connectivity with a digital stethoscope, otoscope, eye exam camera, and dermatoscope. Both devices include procedural guidance capabilities and have various data transmission and report generation features. TECHNOLOGY DEMONSTRATIONS NASA’s exploration-class missions will have severe resource constraints, long return trip durations, significant communication delays, and limited resupply opportunities. The medical systems of these missions will need to fit within an Earth-Independent Medical Operations (EIMO) construct. Key features of an EIMO medical system include: 1) technologies that support the prevention, diagnosis, and treatment of spaceflight medical events; 2) components that meet mass, volume, power and crew time/training constraints; 3) consideration of the medical skill level of the astronaut caregiver; 4) collection, storage and analysis of medical data within a central data architecture; and 5) incorporation of appropriate guidance and support tools that allow crew autonomy. Evaluations are underway to determine if it will be beneficial to include MIM devices within exploration medical systems by conducting a series of planned technical demonstrations. Exploration Atmosphere Chamber studies are being performed to determine MIM functionality in a high oxygen concentration atmosphere. A side-by-side comparison of the Tempus ProTM and LifeBot 10® will be performed during ground-based demonstrations. Use of the MIM devices within an EIMO medical scenario simulation will be practiced during ground-based demonstrations in preparation for International Space Station (ISS) demonstrations of the MIM device. These various demonstrations are designed to gather evidence for or against the inclusion of MIM devices within an EIMO medical system. EXPECTED DEMONSTRATION OUTCOMES Information will be gained about the feasibility, benefits, and challenges of using a multifunctional, all-in-one, medical device for medical diagnosis. Information will also be collected about performance differences as available ground support decreases. Gaining this understanding will allow for further development of exploration medical system capabilities, which take the EIMO construct into consideration.

B. E. Lewandowski↗

An Interface–Type Memristive Device for Artificial Synapse and Neuromorphic Computing

Interface-type (IT) metal/oxide Schottky memristive devices have attracted considerable attention over filament-type (FT) devices for neuromorphic computing because of their uniform, filament-free, and analog resistive switching (RS) characteristics. The most recent IT devices are based on oxygen ions and vacancies movement to alter interfacial Schottky barrier parameters and thereby control RS properties. However, the reliability and stability of these devices have been significantly affected by the undesired diffusion of ionic species. Herein, a reliable interface-dominated memristive device is demonstrated using a simple Au/Nb-doped SrTiO 3 (Nb:STO) Schottky structure. The Au/Nb:STO Schottky barrier modulation by charge trapping and detrapping is responsible for the analog resistive switching characteristics. Because of its interface-controlled RS, the proposed device shows low device-to-device, cell-to-cell, and cycle-to-cycle variability while maintaining high repeatability and stability during endurance and retention tests. Furthermore, the Au/Nb:STO IT memristive device exhibits versatile synaptic functions with an excellent uniformity, programmability, and reliability. A simulated artificial neural network with Au/Nb:STO synapses achieves a high recognition accuracy of 94.72% for large digit recognition from MNIST database. These results suggest that IT resistive switching can be potentially used for artificial synapses to build next-generation neuromorphic computing.

36 MATERIALS SCIENCE↗

Ab initio modeling of transport and thermodynamic stability for hafnia memristive devices

HfO 2 -based memristive switching devices are currently under intensive investigation due to their high performance and mature fabrication techniques. However, several critical issues have to be addressed to bring them from lab to market. We have recently looked into two important issues with the use of density functional theory methods. One is the wide distribution of device resistance in off-states. We have modeled the switching process of a Pt-HfO 2 -Pt structure for which quantized conductance was observed. Oxygen atoms moving inside a conductive oxygen vacancy filament divide the filament into several quantum wells. Device conductance changes exponentially when one oxygen atom moves away from interface into filament. We propose that the high sensitivity of device conductance to the position of oxygen atoms results in the large variation of device off-state resistance. Another issue that we have recently addressed is the poor switching performance of devices based on a TiN-HfO 2 -TiN structure. While recent experiments have shown that by inserting an "oxygen scavenger" metal between positive electrode and oxide significantly improves device performance, the fundamental understanding of the improvement is lacking.We provide detailed understanding how scavenger layers improve device performance. First, we show that Ta insertion facilitates formation of on-states by reducing the formation energy. Second, the inserted Ta layer reduces the Schottky barrier height in the off-states by changing interface electric dipole at the oxide electrode interface. Nevertheless, the device maintains a high on/off resistance ratio. Finally, with Ta insertion the on-state conductance becomes much less sensitive to the specific location from which the oxygen was removed from the oxide. In conclusion, our studies provide fundamental understanding needed for enabling realization of a non-volatile memory technology with reduced energy consumption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of Gallium Nitride Devices in High-Frequency LLC Resonant Converters

Newly emerged gallium nitride (GaN) devices feature ultrafast switching speed and low on-state resistance that potentially provide significant improvements for power converters. Here, this article investigates the benefits of GaN devices in an LLC resonant converter and quantitatively evaluates GaN devices' capabilities to improve converter efficiency. First, the relationship of device and converter design parameters to the device loss is established based on an analytical model of LLC resonant converter operating at the resonance. Due to the low effective output capacitance of GaN devices, the GaN-based design demonstrates about 50% device loss reduction compared with the Si-based design. Second, a new perspective on the extra transformer winding loss due to the asymmetrical primary-side and secondary-side current is proposed. The device and design parameters are tied to the winding loss based on the winding loss model in the finite element analysis (FEA) simulation. Compared with the Si-based design, the winding loss is reduced by 18% in the GaN-based design. Finally, in order to verify the GaN device benefits experimentally, 400- to 12-V, 300-W, 1-MHz GaN-based and Si-based LLC resonant converter prototypes are built and tested. One percent efficiency improvement, which is 24.8% loss reduction, is achieved in the GaN-based converter.

30 DIRECT ENERGY CONVERSION↗

Simulating Thermoelectric Devices Using the MOOSE Framework

Thermoelectric generators (TEG) are devices that generate energy by converting heat into electricity or provide cooling via the Peltier effect. This feature of thermoelectric devices originates from the Seebeck, Peltier, Thomson, and Joule heating effects. TEGs can be applied in energy and thermal management systems such as waste heat recovery and refrigeration, respectively. Thermoelectric device design is influenced by the material selection and the device's geometry operating conditions. Therefore, predicting, verifying, and validating thermoelectric device performance using simulations tools is essential to deploying thermoelectric devices in industry. The Multiphysics Object-Oriented Simulation Environment (MOOSE) Framework is an open-source simulation tool capable of modeling simple to complex systems. In this work, we demonstrate MOOSE's thermoelectric device modeling capabilities by simulating a unicouple, module, and exhaust gas recovery system. The Seebeck, Peltier, Thomson, and Joule heating physics are implemented into MOOSE. The MOOSE thermoelectric physics were thoroughly verified and validated using published COMSOL® results and experimental data. In addition, thermoelectric modules were integrated into an exhaust gas recovery system using the MOOSE MultiApp function as a demonstration of the model's ability. The verification and validation results and exhaust gas heat recovery system showcases MOOSE's capability to model thermoelectric devices and integrate these devices into practical energy systems.

42 - ENGINEERING↗

Performance Limits of an Alternating Current Electroluminescent Device

Abstract The use of an alternating current (AC) voltage is a simple, versatile method of producing electroluminescence from generic emissive materials without the need for contact engineering. Recently, it was shown that AC‐driven, capacitive electroluminescent devices with carbon nanotube network contacts can be used to generate and study electroluminescence from a variety of molecular materials emitting in the infrared‐to‐ultraviolet range. Here, performance trade‐offs in these devices are studied through comprehensive device simulations and illustrative experiments, enhancing understanding of the mechanism and capability of electroluminescent devices based on alternating as opposed to direct current (DC) schemes. AC‐driven electroluminescent devices can overcome several limitations of conventional DC‐driven electroluminescent devices, including the requirement for proper alignment of material energy levels and the need to process emitting materials into uniform thin films. By simultaneously optimizing device geometry, driving parameters, and material characteristics, the performance of these devices can be tuned. Importantly, the turn‐on voltage of AC‐driven electroluminescent devices approaches the bandgap of the emitting material as the gate oxide thickness is scaled, and internally efficient electroluminescence can be achieved using low‐mobility single‐layer emitter films with varying thicknesses and energy barrier heights relative to the contact.

Wang, Vivian↗

In Situ Chemical Monitoring and Imaging of Contents within Microfluidic Devices Having a Porous Membrane Wall Using Liquid Microjunction Surface Sampling Probe Mass Spectrometry

The ability to observe dynamic chemical processes (e.g., signaling, transport, etc.) in vivo or in situ using nondestructive chemical imaging opens a new door to understanding the complex dynamics of developing biological systems. With the advent of “biology-on-a-chip” devices has come the ability to monitor dynamic chemical processes in a controlled environment, using these engineered habitats to capture key features of natural systems while allowing visual observation of system development. Having the capability to spatially and temporally map the chemical signals within these devices may yield new insights into the forces that drive biosystem development. Here, a porous membrane sealed microfluidic device was designed to allow normal microfluidic operation while enabling continuous, location specific sampling and chemical characterization by liquid microjunction surface sampling probe mass spectrometry (LMJ-SSP MS). LMJ-SSP was used to extract fluids with nL-to-μL/min flow rates directly from selected areas of the microfluidic device without negatively impacting the device function. These extracts were subsequently characterized using MS. This technique was used to acquire MS images of the entirety of several multi-input microfluidic devices having different degrees of fluid mixing. LMJ-SSP MS imaging visualized the spatial distribution of chemical components within the microfluidic channels and could visualize chemical reactions occurring in the device. These microfluidic devices with a porous membrane wall are wholly compatible with the construction of biology-on-a-chip devices. This ultimately would enable correlation of biosystem physical structure with an evolving chemical environment

47 OTHER INSTRUMENTATION↗

The strain capacitor: A novel energy storage device

A novel electromechanical energy storage device is reported that has the potential to have high energy densities. It can efficiently store both mechanical strain energy and electrical energy in the form of an electric field between the electrodes of a strain-mismatched bilayer capacitor. When the charged device is discharged, both the electrical and mechanical energy are extracted in an electrical form. The charge-voltage profile of the device is suitable for energy storage applications since a larger portion of the stored energy can be extracted at higher voltage levels compared to a normal capacitor. Its unique features include the potential for long lifetime, safety, portability, wide operating temperature range, and environment friendliness. The device can be designed to operate over varied operating voltage ranges by selecting appropriate materials and by changing the dimensions of the device. In this paper a finite element model of the device is developed to verify and demonstrate the potential of the device as an energy storage element. This device has the potential to replace conventional energy storage devices.

36 MATERIALS SCIENCE↗

Performance comparison between photovoltaic and thermoradiative devices

Photovoltaic (PV) and thermoradiative (TR) devices are power generators that use the radiative energy transfer between a hot and a cold reservoir. For PV devices, the semiconductor at the cold side (PV cell) generates electric power; for TR devices, the semiconductor at the hot side (TR cell) generates electric power. In this work, we compare the performance of the photovoltaic and thermoradiative devices, with and without the non-radiative processes. Without non-radiative processes, PV devices generally produce larger output powers than TR devices. However, when non-radiative processes become important, the TR can outperform the PV devices. This conclusion applies to both far-field and near-field based devices. A key difference in efficiency between PV and TR devices is pointed out.

42 ENGINEERING↗

User Impressions and Gait Analysis of Exoskeleton Device Usage in Generalized Tank Farm Activities

Tank farm workers involved in nuclear cleanup activities perform physically demanding tasks, typically while wearing heavy personal protective equipment (PPE). Exoskeleton devices have the potential to bring considerable benefit to this industry but have not been thoroughly studied in the context of nuclear cleanup. In this paper, we examine the performance of exoskeletons during a series of tasks emulating jobs performed on tank farms while participants wore PPE commonly deployed by tank farm workers. The goal of this study was to evaluate the effects of commercially available lower-body exoskeletons on a user’s gait kinematics and user perceptions. Three participants each tested three lower-body exoskeletons in a 70-min protocol consisting of level treadmill walking, incline treadmill walking, weighted treadmill walking, a weight lifting session, and a hand tool dexterity task. Results were compared to a no exoskeleton baseline condition and evaluated as individual case studies. The three participants showed a wide spectrum of user preferences and adaptations toward the devices. Individual case studies revealed that some users quickly adapted to select devices for certain tasks while others remained hesitant to use the devices. Temporal effects on gait change and perception were also observed for select participants in device usage over the course of the device session. Here, device benefit varied between tasks, but no conclusive aggregate trends were observed across devices for all tasks. Evidence suggests that device benefits observed for specific tasks may have been overshadowed by the wide array of tasks used in the protocol.

Tank farm↗

Experimental testing of additively manufactured embedded fiber optic smart devices for clean energy applications

Abstract An additively manufactured prototype smart device was created to investigate in-flow temperature distributions using embedded high-definition fiber optic sensors within a component for clean energy systems. The devices were created using Ultrasonic Additive Manufacturing to create a unique embedded pathway within a flow conditioner for the high-definition fiber optic sensors to be placed within. The fibers used allowed for temperature measurements to be taken every 0.65 mm along the fiber. The high-resolution fibers were thermally calibrated enable the 2D reconstruction of the temperature profile in the flow path of the structure. This is due to the temperature-related strain response of the material and strain measurements of the fibers. Hot airflow testing of these devices showed the ability to identify localized temperature differences in the flow. The observed strain response within the smart device had higher strain concentrations in the thicker web regions than in the thinner web regions. These higher strain regions resulted in higher uncertainties for the temperature responses. Further calibration is needed to improve the accuracy of the smart devices, specifically within the inner web structures of a flow straightening component. Further investigations of the devices within flow showed the temperature sensing to be independent of the effects of flow velocity. The devices were able to distinguish temperature differences within single and two-phase flow and showed local sensitivity to the temperature changes with the identification of hot and cold spots. The presented results showed the viability of the smart device for obtaining detailed temperature distributions using common industrial components. Eventually, the goal for these smart devices will be to withstand higher temperature and pressure environments such as those experienced in nuclear, fusion, and concentrated solar energy systems.

Donlan, Connor F. (ORCID:0000000223317882)↗

Comparative Performance of Three Eye-Tracking Devices in Detection of Mild Traumatic Brain Injury in Acute Versus Chronic Subject Populations

ABSTRACT Introduction Presently, traumatic brain injury (TBI) triage in field settings relies on symptom-based screening tools such as the updated Military Acute Concussion Evaluation. Objective eye-tracking may provide an alternative means of neurotrauma screening due to sensitivity to neurotrauma brain-health changes. Previously, the US Army Medical Research and Development Command Non-Invasive NeuroAssessment Devices (NINAD) Integrated Product Team identified 3 commercially available eye-tracking devices (SyncThink EYE-SYNC, Oculogica EyeBOX, NeuroKinetics IPAS) as meeting criteria toward being operationally effective in the detection of TBI in service members. We compared these devices to assess their relative performance in the classification of mild traumatic brain injury (mTBI) subjects versus normal healthy controls. Materials and Methods Participants 18 to 45 years of age were assigned to Acute mTBI, Chronic mTBI, or Control group per study criteria. Each completed a TBI assessment protocol with all 3 devices counterbalanced across participants. Acute mTBI participants were tested within 72 hours following injury whereas time since last injury for the Chronic mTBI group ranged from months to years. Discriminant analysis was undertaken to determine device classification performance in separating TBI subjects from controls. Area Under the Curves (AUCs) were calculated and used to compare the accuracy of device performance. Device-related factors including data quality, the need to repeat tests, and technical issues experienced were aggregated for reporting. Results A total of 63 participants were recruited as Acute mTBI subjects, 34 as Chronic mTBI subjects, and 119 participants without history of TBI as controls. To maximize outcomes, poorer quality data were excluded from analysis using specific criteria where possible. Final analysis utilized 49 (43 male/6 female, mean [x̅] age = 24.3 years, SD [s] = 5.1) Acute mTBI subjects, and 34 (33 male/1 female, x̅ age = 38.8 years, s = 3.9) Chronic mTBI subjects were age- and gender-matched as closely as possible with Control subjects. AUCs obtained with 80% of total dataset ranged from 0.690 to 0.950 for the Acute Group and from 0.753 to 0.811 for the Chronic mTBI group. Validation with the remaining 20% of dataset produced AUCs ranging from 0.600 to 0.750 for Acute mTBI group and 0.490 to 0.571 for the Chronic mTBI group. Conclusions Potential eye-tracking detection of mTBI, per training model outcomes, ranged from acceptable to excellent for the Acute mTBI group; however, it was less consistent for the Chronic mTBI group. The self-imposed targeted performance (AUC of 0.850) appears achievable, but further device improvements and research are necessary. Discriminant analysis models differed for the Acute versus Chronic mTBI groups, suggesting performance differences in eye-tracking. Although eye-tracking demonstrated sensitivity in the Chronic group, a more rigorous and/or longitudinal study design is required to evaluate this observation. mTBI injuries were not controlled for this study, potentially reducing eye-tracking assessment sensitivity. Overall, these findings indicate that while eye-tracking remains a viable means of mTBI screening, device-specific variability in data quality, length of testing, and ease of use must be addressed to achieve NINAD objectives and DoD implementation.

General & Internal Medicine↗

Cyber Protection of Grid-Connected Devices Through Embedded Online Security

Cybersecurity research regarding the electric power grid has primarily been focused on protecting the communication layer of grid-connected devices against cyber-attack threats. Although many developed methods have greatly reduced the effects of a cyber-attack on the vulnerabilities of grid-connected devices, discovering new vulnerabilities is inevitable and a constant threat. As a result, the overall reliability and security of network communications with regard to grid-connected devices is a concern. Here, this paper proposes a method that further secures a system by focusing on the control and hardware layer of grid-connected devices. The device’s controller firmware will be validated and authenticated using integrated device emulation resources prior to being activated to control the grid-connected device. This verification process is performed while the controller is online and actively controlling power flows related to the device. Therefore, an attack to the system through a malicious firmware patch would be detected by the online security and rejected while safely maintaining continuous and stable control of the device. This method integrates the concepts of firmware hot-patching, digital twins, and active monitoring into an overall cybersecurity protection system.

cybersecurity↗

Investigating Users’ Privacy Concerns of Internet of Things (IoT) Smart Devices

Although the number of smart Internet of Things (IoT) devices has grown in recent years, the public's perception of how effectively these devices secure IoT data has been questioned. Many IoT users do not have a good level of confidence in the security or privacy procedures implemented within IoT smart devices for protecting personal IoT data. Moreover, determining the level of confidence end users have in their smart devices is becoming a major challenge. In this paper, we present a study that focuses on identifying privacy concerns IoT end users have when using IoT smart devices. We investigated multiple smart devices and conducted a survey to identify users’ privacy concerns. Furthermore, we identify five IoT privacy-preserving (IoTPP) control policies that we define and employ in comparing the privacy measures implemented by various popular smart devices. Results from our study show that the over 86% of participants are very or extremely concerned about the security and privacy of their personal data when using smart IoT devices such as Google Nest Hub or Amazon Alexa. In addition, our study shows that a significant number of IoT users may not be aware that their personal data is collected, stored or shared by IoT devices.

Joy, Daniel↗

SU-F-J-115: Target Volume and Artifact Evaluation of a New Device-Less 4D CT Algorithm

Purpose: 4DCT is often used in radiation therapy treatment planning to define the extent of motion of the visible tumor (IGTV). Recent available software allows 4DCT images to be created without the use of an external motion surrogate. This study aims to compare this device-less algorithm to a standard device-driven technique (RPM) in regards to artifacts and the creation of treatment volumes. Methods: 34 lung cancer patients who had previously received a cine 4DCT scan on a GE scanner with an RPM determined respiratory signal were selected. Cine images were sorted into 10 phases based on both the RPM signal and the device-less algorithm. Contours were created on standard and device-less maximum intensity projection (MIP) images using a region growing algorithm and manual adjustment to remove other structures. Variations in measurements due to intra-observer differences in contouring were assessed by repeating a subset of 6 patients 2 additional times. Artifacts in each phase image were assessed using normalized cross correlation at each bed position transition. A score between +1 (artifacts “better” in all phases for device-less) and −1 (RPM similarly better) was assigned for each patient based on these results. Results: Device-less IGTV contours were 2.1 ± 1.0% smaller than standard IGTV contours (not significant, p = 0.15). The Dice similarity coefficient (DSC) was 0.950 ± 0.006 indicating good similarity between the contours. Intra-observer variation resulted in standard deviations of 1.2 percentage points in percent volume difference and 0.005 in DSC measurements. Only two patients had improved artifacts with RPM, and the average artifact score (0.40) was significantly greater than zero. Conclusion: Device-less 4DCT can be used in place of the standard method for target definition due to no observed difference between standard and device-less IGTVs. Phase image artifacts were significantly reduced with the device-less method.

60 APPLIED LIFE SCIENCES↗