Implementation of the final geometry of the V0A detector for the ALICE experiment in the simulator program AliRoot

The V0A trigger detector of the ALICE experiment is a scintillator hodoscope of 32 channels that has been designed and constructed by the Mexican groups at the Instituto de Fisica de la UNAM and the CINVESTAV.In this work, the final geometry of the constructed detector and its support frame have been implemented using the geometrical modeler of the Root framework in order to be able to simulate the response and trigger performance of the detector with AliRoot.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GlueX: Detector Construction and Event Simulations

The GlueX experiment[1] at Jefferson Lab is designed to map out the spectrum of light hybrid mesons and, in particular, identify those with exotic quantum numbers[2]. Exotic hybrid mesons populate states that cannot be described as a simple quark-antiquark pair, but require the introduction of a gluonic excitation. Their existence is predicted by lattice QCD[3], but their experimental signature is still limited. The experimental building (Hall D) is nearing completion and major parts of the detector construction are well under way. An overview of the final detector and its construction status will be presented, together with some results from the ongoing simulation analyses to identify the exotic quantum number states in GlueX.

Jarvis, Naomi↗

Impact of Source Geometry on Detector Response Matrix Efficiency: Simulations of the PFUNS-MUSiC Experiments

This work looks at two different bare highly enriched uranium (HEU) systems, configuration one from Measurements of Uranium Subcritical and Critical (MUSiC) and Prompt Fission Uranium Neutron Spectrum (PFUNS) to see the effect geometry has on detector efficiency and the response matrix. The distance from the multiplying source, the medium between the source and detector, and the geometry of the source all play a part in the efficiency of the detector. These factors are especially important when performing spectrum unfolding. Spectrum unfolding is a process used to reconstruct a true spectrum from measured detector response data. It involves interpreting a set of measured values, such as a light signal from a scintillator, to recover the original neutron energy spectrum. This leads to the question, how much will the efficiency of a detector change when you measure a point source compared to an extended source? The distance and solid angle from the source to the detector may be different. It may only be a minuscule change, but in the spectrum unfolding process it can have a considerable effect on the unfolded spectrum

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo Simulations of Microchannel Plate Detectors II: Pulsed Voltage Results

This paper is part of a continuing study of straight-channel microchannel plate (MCP)–based x-ray detectors. Such detectors are a useful diagnostic tool for two-dimensional, time-resolved imaging and time-resolved x-ray spectroscopy. To interpret the data from such detectors, it is critical to develop a better understanding of the behavior of MCPs biased with subnanosecond voltage pulses. The subject of this paper is a Monte Carlo computer code that simulates the electron cascade in a MCP channel under an arbitrary pulsed voltage, particularly those pulses with widths comparable to the transit time of the electron cascade in the MCP under DC voltage bias. We use this code to study the gain as a function of time (also called the gate profile or optical gate) for various voltage pulse shapes, including pulses measured along the MCP. In addition, experimental data of MCP behavior in pulsed mode are obtained with a short-pulse UV laser. Comparisons between the simulations and experimental data show excellent agreement for both the gate profile and the peak relative sensitivity along the MCP strips. We report that the dependence of relative gain on peak voltage increases in sensitivity in pulsed mode when the width of the high-voltage waveform is smaller than the transit time of cascading electrons in the MCP.

Kruschwitz, Craig A.↗

Web-based, GPU-accelerated, Monte Carlo simulation and visualization of indirect radiation imaging detector performance

Purpose: Monte Carlo simulations play a vital role in the understanding of the fundamental limitations, design, and optimization of existing and emerging medical imaging systems. Efforts in this area have resulted in the development of a wide variety of open-source software packages. One such package, hybridMANTIS, uses a novel hybrid concept to model indirect scintillator detectors by balancing the computational load using dual CPU and graphics processing unit (GPU) processors, obtaining computational efficiency with reasonable accuracy. In this work, the authors describe two open-source visualization interfaces, webMANTIS and visualMANTIS to facilitate the setup of computational experiments via hybridMANTIS. Methods: The visualization tools visualMANTIS and webMANTIS enable the user to control simulation properties through a user interface. In the case of webMANTIS, control via a web browser allows access through mobile devices such as smartphones or tablets. webMANTIS acts as a server back-end and communicates with an NVIDIA GPU computing cluster that can support multiuser environments where users can execute different experiments in parallel. Results: The output consists of point response and pulse-height spectrum, and optical transport statistics generated by hybridMANTIS. The users can download the output images and statistics through a zip file for future reference. In addition, webMANTIS provides a visualization window that displays a few selected optical photon path as they get transported through the detector columns and allows the user to trace the history of the optical photons. Conclusions: The visualization tools visualMANTIS and webMANTIS provide features such as on the fly generation of pulse-height spectra and response functions for microcolumnar x-ray imagers while allowing users to save simulation parameters and results from prior experiments. The graphical interfaces simplify the simulation setup and allow the user to go directly from specifying input parameters to receiving visual feedback for the model predictions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Heavy Resonances in the Dimuon Channel with the DØ Detector

High-energy particle physics is often described as the quest for a fundamental theory. One can think of one theory as being more "fundamental" than a second theory if the first explains some or all of the predictions of the second in terms of processes at smaller distance scales and higher energies. Another sense in which a theory can be thought of as being more fundamental than another, is if the first theory "explains" the second; that is, if some arbitrary aspect of the second theory is a special case of a more general principle in the first theory. The Standard Model of particle physics is the most fundamental experimentally tested theory in either sense. It was developed in its final form in the 1960's and 1970's and continues to successfully predict the outcomes of high-energy physics experiments; the research presented in this thesis offers no exception to this trend ( unfortunately). However, the Standard Model only makes sense as an effective theory; that is, a theory that is not actually fundamental, but which is a low-energy limit of some underlying theory, without being dependent on the details of that underlying theory. Moreover, one important aspect of the Standard Model so far remains unexplained, namely electroweak symmetry breaking. Phase transitions occur in many places in physics, and can often be explained as a low-energy aspect of some more fundamental process. However, there is no such underlying process for electroweak symmetry breaking within the Standard Model; the introduction of the scalar Higgs field does not, in itself, explain electroweak symmetry breaking, it merely parameterizes it. Therefore, it is perhaps not surprising that the (most obvious) problem with the Standard Model, the '·gauge hierarchy problem", occurs in relation with the Higgs field. This problem, the "unnaturalness" of the Standard Model, will be discussed (briefly) in the next chapter. It so happens that the unnaturalness of the Standard Model strongly suggests the presence of new physics at an energy scale that is very close to the energies achieved with the Tevatron collider (and presumably well within the reach of the next collider, the LHC). Therefore, there is a general expectation that new physics is "just around the corner". Many, many models for new physics exist, and it is not possible to devise an optimal search strategy for all of them at once. Therefore (and possibly to reduce bias), it is preferable to search for new physics in a model-independent way. While the analysis presented in this thesis is certainly not model-independent, it uses the fact that many, often very different models share the prediction of a new mass resonance. Specifically, we search for such resonances in the dimuon channel. Since no new resonance was in fact observed, the various models only serve to parameterize the degree to which nothing was found. In chapter 2, an outline of the Standard Model is given, and some extensions to the Standard Model are described. Chapter 3 describes the accelerator complex and the D0 detector. Chapter 4 describes the simulation of both Standard Model and new physics processes and the detector simulation. Chapter 5 describes the data sample, the reconstruction algorithms, the event selection and the kinematic fit. A sample of high-PT dimuon events is obtained by applying a number of cuts, and the simulation is tuned to match the efficiencies and track resolution measured on Z→ μ + μ - data. The integrated luminosity times the trigger efficiency of the final sample is determined by comparing it to the predicted (and well-tested) Z cross section. The mass resolution is improved by a kinematic fit which uses the transverse energy balance in the event to constrain the muon track P T for each event in the final selection. In chapter 6, a final cut on the (fitted) invariant mass of the selected events is chosen in such a way that it maximizes the sensitivity to the presence of new physics for specific models and resonance masses. A counting experiment is performed for several values of the mass of a hypothetical new particle. Since no excess over the predicted background is observed, Bayesian credibility limits on the production cross-section times branching ratio of the hypothetical new particles were calculated, as well as limits on the parameters of new physics models. The uncertainties on the theory and detector simulation are taken into account. An event display of the highest reconstructed mass event is shown as well. Finally, chapter 7 gives a conclusion, some prospects of improving the result and a brief outlook.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geant4-based multiphysics simulation toolkit for analysis of radiation detector performance

Often only a single physical process or component is investigated in the simulation of radiation detector systems. The results are then considered to be representative of what is expected in the correlating physical experiment. Although singular assessments may serve as a good estimate, the overall performance of a radiation detector system depends on several physical processes and the performance of all components within the system. Our Geant4-based multiphysics simulation toolkit couples radiation transport with optical photon processes, providing simulations of radiation detector systems components from the scintillator through the photocathode of the photodetector. Work to incorporate the back-end detector components, including the complete photodetector and subsequent electronics (e.g., amplifiers, digitizers), is underway. Geant4 is used to model the radiation transport and optical photon processes that occur in the front-end detector system components when exposed to a chosen source. These components include the scintillator, detector housing, optical coupling to the photodetector, and photocathode of the photodetector. Characteristics of several detector systems that have been studied include time response; pulse height spectra; number of photoelectrons per MeV; detector efficiency versus incident quanta energy; and effects on detector response due to change in geometries, materials, and reflectivity. Comparison of these characteristics by means of this toolkit enables the selection of the optimal individual components; thus, it is possible to specify the radiation detector system best suited to meet the requirements of any physical experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geometrical expression for the angular resolution of a network of gravitational-wave detectors

We report for the first time general geometrical expressions for the angular resolution of an arbitrary network of interferometric gravitational-wave (GW) detectors when the arrival time of a GW is unknown. We show explicitly elements that decide the angular resolution of a GW detector network. In particular, we show the dependence of the angular resolution on areas formed by projections of pairs of detectors and how they are weighted by sensitivities of individual detectors. Numerical simulations are used to demonstrate the capabilities of the current GW detector network. We confirm that the angular resolution is poor along the plane formed by current LIGO-Virgo detectors. A factor of a few to more than ten fold improvement of the angular resolution can be achieved if the proposed new GW detectors LCGT or AIGO are added to the network. We also discuss the implications of our results for the design of a GW detector network, optimal localization methods for a given network, and electromagnetic follow-up observations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-18C-05: Characterization of a Silicon Strip Photon-Counting Detector in the Presence of Compton Scatter: A Simulation Study

Purpose: To investigate the effect of Compton scatter on detection efficiency and charge-sharing for a Si strip photon-counting detector as a function of pixel pitch, slice thickness and total pixel length. Methods: A CT imaging system employing a silicon photon-counting detector was implemented using the GATE Monte Carlo package. A focal spot size of 300 µm, magnification of 1.33, and pixel pitches of 0.1 and 0.5mm were initially investigated. A 60 kVp spectrum with 3 mm Al filter was used and energy spectral degradation based on a prototype detector was simulated. To study charge-sharing, a single pixel was illuminated, and the detector response in neighboring pixels was investigated. A longitudinally semiinfinite detector was simulated to optimize the quantum detection efficiency of the imaging system as a function of pixel pitch, slice thickness and depth of interaction. A 2.5 mm thick tungsten plate with a 0.01 mm by 1.5 mm slit was implemented to calculate the modulation transfer function (MTF) from projection-based images. A threshold of 15 keV was implemented in the detector simulation. The preliminary charge sharing investigation results considered only scattering effects and the detector electronics related factors were neglected. Results: Using a 15 keV threshold, 1% of the pixel charge migrated into neighboring pixels with a pixel size of 0.1×0.1 mm{sup 2}. The quantum detection efficiency was 77%, 84%, 87% and 89% for 15 mm, 22.5 mm, 30 mm, and 45 mm length silicon detector pixels, respectively. For a pixel pitch of 0.1 mm, the spatial frequency at 10% of the maximum MTF was found to be 5.2 lp/mm. This agreed with an experimental MTF measurement of 5.3 lp/mm with a similar detector configuration. Conclusion: Using optimized design parameters, Si strip photon-counting detectors can offer high detection efficiency and spatial resolution even in the presence of Compton scatter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Position sensitive alpha detector for an associated particle imaging system

Associated Particle Imaging (API) is a nuclear technique that provides for the nondestructive determination of 3D isotopic distributions. The method is based on the detection of the alpha particles associated with the neutron emitted in the deuterium-tritium (DT) fusion reaction, which provides information regarding the direction and time of the emitted 14 MeV neutron. Inelastic neutron scattering leads to characteristic gamma-ray emission from certain isotopes, for example 12 C, that can be correlated with the neutron interaction location. An API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector is under development for the nondestructive quantification of carbon distribution in soils. This paper describes the design of the alpha detector, detector response simulations, and first experimental results. The alpha detector consists of a Yttrium Aluminum Perovskite (YAP) scintillator mounted on the inside of a neutron generator tube. The scintillation light propagates through a sapphire window to a position-sensitive photomultiplier tube mounted on the outside. The 16x16 output signals are connected through a resistive network for a 4-corner readout. The four readout channels are amplified, filtered, and then digitized for the calculation of the alpha position. First test findings demonstrate that an excellent alpha position resolution, better than the 1 mm FWHM required by the application, can be achieved with this detector design.

47 OTHER INSTRUMENTATION↗

The Urban Deployment Model: A Toolset for the Simulation and Performance Characterization of Radiation Detector Deployments in Urban Environments

Static and mobile radiation detectors can be deployed in urban environments for a range of nuclear security applications, including radiological source search-and-tracking scenarios. Modeling detector performance for such applications is challenging, as it does not depend solely on the detector capabilities themselves. Many factors must be taken into consideration, including specific source and background signatures, the topology and constraints of the deployment environment, the presence of nuisance sources, and whether detectors are mobile or static. When considering the simultaneous deployment of multiple, heterogeneous detectors, assessment of the system-wide performance requires the simulation of the individual detectors, and a system-level analysis of the detection performance. In radiological source search-and-tracking scenarios, performance is mostly dominated by the probability of encounter, which depends on the specifics of a given deployment, e.g., static vs. mobile detectors or a combination of both modalities, the number of detectors deployed, the dynamic vs. static setting of false alarm rates, and individual vs. networked operation. The Urban Deployment Model (UDM) toolset was specifically developed to cover the gap in the available generic frameworks for the simulation of radiation detector deployments at city scales. UDM provides a unified and modular framework to support the simulation and performance characterization of heterogeneous detector deployments in urban environments. This paper presents the key components along the UDM workflow.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

X-ray and γ-ray beam interstellar communication and implications for SETI

The possibility of detecting artificial signals transmitted by alien civilizations via collimated X-ray or gamma-ray beams is investigated. The prospect of using such beams for human communication within the solar system and beyond is also discussed. Detector responses were simulated for input signals and analyzed using relative entropy. For simplicity, all signals were assumed to use on-off keying (OOK) modulation. “Real” signals were generated by taking digital files and sequentially feeding their raw binary data to the detector simulator, the resulting normalized information content of the detector signals was plotted and compared to random noise signals. Since jpeg files contain compressed information, these served as a proxy for artificial alien signals. This showed that there is a clear difference in measured information content between natural and artificial signals, even with relatively poor time resolution in the detector causing the signals to be smeared (dead-time/rise-time intervals many times longer than the duration between signal pulses). It was found that so long as the signal lasts for at least several rise-time/dead-time intervals, the distinction between random and artificial signals is obvious. A space-telescope with high time resolution for searching for such signals is briefly described and its basic requirements are outlined.

43 PARTICLE ACCELERATORS↗

Improving The Simulation Of Muons In The Rock Around The NOvA Near Detector

This thesis investigates the viability of the PROPOSAL lepton propagation tool as an alternative to the commonly used GEANT4 simulation for muon propagation within the NOvA experiment. The main objectives of this research were twofold: first, to validate the accuracy of PROPOSAL data in simulating rock muons when compared to GEANT4 data; second, to explore the practical application of transporting cosmic muons through the NOvA rock region using PROPOSAL. Additionally, an 1D analysis was conducted to determine the optimal altitude at which to hand over the simulation task from PROPOSAL to GEANT4, should we choose to use PROPOSAL for rock simulations and GEANT4 for detector simulations in the NOvA experiment. By thoroughly examining these aspects, this study aims to contribute to the advancement of muon simulation techniques and their implementation in high-energy experiments such as NOvA.

Parvez, Radwan↗

A simulation study of the ability to detect power distribution perturbations in the texas A&M TRIGA reactor with self-powered neutron detectors

Given the variety of ways that nuclear reactor core power may be perturbed, reactor operators and developers are keen on understanding the accuracy and convergence time during which perturbations in reactor power distribution may be synthesized (i.e., inferred) from an array of in-core radiation detectors. A simulation study was conducted as described herein using a highly detailed model of the Texas A&M Training, Research, Isotopes, General Atomics Reactor, in which an array of self-powered neutron detectors (SPNDs) was considered for input to the power synthesis methodology. The core power synthesis is conducted using a point-based iterative method with an iterative loop built in to ensure working equation consistency. The forward problem of SPND response to simulated perturbations in reactor power was solved for Gaussian peak-type perturbations in the reactor power distribution. These perturbations varied in variance, amplitude, and core location to assess their impact on synthesis error and to determine the number of iterations required for convergence. A relation between the unique resolvability limit and perturbation width was identified such that the maximum synthesis error increased rapidly when the peak width went beneath this limit (a width approximating half the reactor’s fuel pin-to-pin pitch); this resolvability limit is specific to the SPND configuration and fuel segmentation considered herein. The synthesis error increased linearly with perturbation peak amplitude, whereas the convergence time increased nonlinearly. Perturbations located closer to the center of the core were synthesized more accurately, albeit with a higher number of required iterations. These findings provide a qualitative and quantitative understanding of the accuracy and speed at which different types of spatial power perturbations can be resolved in light-water reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-F-19A-05: Experimental and Monte Carlo Characterization of the 1 Cm CivaString 103Pd Brachytherapy Source

Purpose: To determine the in-air azimuthal anisotropy and in-water dose distribution for the 1 cm length of the CivaString {sup 103}Pd brachytherapy source through measurements and Monte Carlo (MC) simulations. American Association of Physicists in Medicine Task Group No. 43 (TG-43) dosimetry parameters were also determined for this source. Methods: The in-air azimuthal anisotropy of the source was measured with a NaI scintillation detector and simulated with the MCNP5 radiation transport code. Measured and simulated results were normalized to their respective mean values and compared. The TG-43 dose-rate constant, line-source radial dose function, and 2D anisotropy function for this source were determined from LiF:Mg,Ti thermoluminescent dosimeter (TLD) measurements and MC simulations. The impact of {sup 103}Pd well-loading variability on the in-water dose distribution was investigated using MC simulations by comparing the dose distribution for a source model with four wells of equal strength to that for a source model with strengths increased by 1% for two of the four wells. Results: NaI scintillation detector measurements and MC simulations of the in-air azimuthal anisotropy showed that ≥95% of the normalized data were within 1.2% of the mean value. TLD measurements and MC simulations of the TG-43 dose-rate constant, line-source radial dose function, and 2D anisotropy function agreed to within the experimental TLD uncertainties (k=2). MC simulations showed that a 1% variability in {sup 103}Pd well-loading resulted in changes of <0.1%, <0.1%, and <0.3% in the TG-43 dose-rate constant, radial dose distribution, and polar dose distribution, respectively. Conclusion: The CivaString source has a high degree of azimuthal symmetry as indicated by the NaI scintillation detector measurements and MC simulations of the in-air azimuthal anisotropy. TG-43 dosimetry parameters for this source were determined from TLD measurements and MC simulations. {sup 103}Pd well-loading variability results in minimal variations in the in-water dose distribution according to MC simulations. This work was partially supported by CivaTech Oncology, Inc. through an educational grant for Joshua Reed, John Micka, Wesley Culberson, and Larry DeWerd and through research support for Mark Rivard.

07 ISOTOPE AND RADIATION SOURCES↗

Digitization modeling of a CGEM detector based on Garfield++ simulation

Abstract Background The Cylindrical Gas Electron Multiplier Inner Tracker (CGEM-IT) is one of the candidates for the replacement of the current BESIII inner drift chamber, which has developed serious aging effects due to beam-related backgrounds. Purpose To build a full digitization model, it is necessary to understand the electron drift behavior and signal induction. Methods A simulation study based on Garfield++ and ANSYS software has been performed. Results Parameters describing the Lorentz angle, diffusion effect, drift time, multiplication, and induction are obtained from the Garfield++ simulation. Based on these results, a preliminary digitization model is implemented in the BESIII offline software system.

Zhao, Jing-Yi (ORCID:0000000220287286)↗

Monte Carlo Simulation of Spacecraft Particle Detectors to Assess the True Human Risk

Particle detectors (DOSTEL, CPDS, and TEPC) measure the energy deposition spectrum inside earth orbiting - manned spacecraft (shuttle, space station). These instruments attempt to emulate the deposition of energy in human tissue to evaluate the health risk. However, the measurements are often difficult to relate to tissue equivalent because nuclear fragmentation (internuclear cascade/evaporation), energy-loss straggling, heavy ions, spacecraft shielding and detector geometry/orientation, and coincidence thresholds significantly affect the measured spectrum. 'A le have developed a high fidelity Monte Carlo model addressing each of these effects that significantly improves interpretation of these instruments and the resulting assessment of radiation risk to humans.

O'Neill, Patrick M.↗