Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “demand response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Market and Policy Barriers for Demand Response Providing Ancillary Services in U.S. Markets

In this study, we attempt to provide a comprehensive examination of various market and policy barriers to demand response providing ancillary services in both ISO/RTO and non-ISO/RTO regions, especially at the program provider level. It is useful to classify barriers in order to create a holistic understanding and identify parties that could be responsible for their removal. This study develops a typology of barriers focusing on smaller customers that must rely on a program provider (i.e., electric investor owned utility or IOU, ARC) to create an aggregated DR resource in order to bring ancillary services to the balancing authority.ii The barriers were identified through examinations of regulatory structures, market environments, and product offerings; and discussions with industry stakeholders and regulators. In order to help illustrate the differences in barriers among various wholesale market designs and their constituent retail environments, four regions were chosen to use as case studies: Colorado, Texas, Wisconsin, and New Jersey. We highlight the experience in each area as it relates to the identified barriers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Empirical Assessment of the Appliance-Level Load Shape and Demand Response Potential in India

Over the next 15 years, electricity demand from the key residential and commercial appliances is projected to be nearly 300 GW or ~65% of India’s total peak demand. The objective of this study is to characterize appliance level demand and temporal variation, and identify the overall DR potential in India. We use Bangalore Electricity Supply Company territory (peak load of 3,505 MW in 2016) as a case study, using actual one-minute resolution load data for 2,979 distribution feeders and a detailed load survey. Our results show that agricultural pumping and space cooling (residential, commercial, and industrial) are the main contributors to the peak demand – with shares of 23-27% and 14-23%, respectively. Both sectors have about 1,000 MW of DR potential – agricultural pumps offering load shifting service while space cooling offering shimmy service that is capable of dynamically adjusting to react to short-run ramps and grid disturbances. Residential electric water heaters contribute nearly 18% of the winter morning peak demand and can also offer about 500 MW in shimmy service. Overall, we find that shifting and shimmy services offer 1,199 MW and 1,511 MW total DR potential, respectively.

demand response↗

Voltage-Load Sensitivity Matrix Based Demand Response for Voltage Control in High Solar Penetration Distribution Feeders

This paper presents a voltage-load sensitivity matrix (VLSM) based voltage control method to deploy demand response resources for controlling voltage in high solar penetration distribution feeders. The IEEE 123-bus system in OpenDSS is used for testing the performance of the preliminary VLSM-based voltage control approach. A load disaggregation process is applied to disaggregate the total load profile at the feeder head to each load nodes along the feeder so that loads are modeled at residential house level. Measured solar generation profiles are used in the simulation to model the impact of solar power on distribution feeder voltage profiles. Different case studies involving various PV penetration levels and installation locations have been performed. Simulation results show that the VLSM algorithm performance meets the voltage control requirements and is an effective voltage control strategy.

distribution system modeling↗

A Hierarchical VLSM-Based Demand Response Strategy for Coordinative Voltage Control between Transmission and Distribution Systems

This paper presents a two-stage hierarchical voltage-load sensitivity matrix (VLSM)-based demand response (DR) algorithm for regulating the voltage at distribution feeders while fulfilling the transmission system DR requests. This allows distributed energy resources be aggregated to provide transmission-level services without causing operational issues in the distribution grids. At the beginning of each operation interval, a transmission system controller will issue DR commands to distribution system controllers. In the first stage, the distribution system controller uses a VLSM-based dispatch algorithm to dispatch the available DR resources on the distribution feeder with an objective to minimize the total voltage deviations at the lowest cost. Then, power flow studies are conducted assuming that the DR commands have been executed. If voltage violations are detected, a second-stage VLSM-based DR dispatch will be performed to remove those violations. After that, the upper and lower DR limits calculated for the next operation interval are sent back to the transmission system controller so the transmission optimization algorithm can use them as operational constraints to make subsequent decisions. The DR resources include smart photovoltaic (PV) inverters that can curtail real power and provide reactive power support, controllable loads and capacitor banks. In conclusion, the IEEE 123-bus test system with 5-minute PV and load data is used to evaluate the performance of the algorithm. In conclusion, simulation results show that the proposed algorithm can fulfill the transmission-level DR requests while maintaining the voltage in the distribution system within limits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of plug-in hybrid electric vehicles on power systems with demand response and wind power.

This paper uses a new unit commitment model which can simulate the interactions among plug-in hybrid electric vehicles (PHEVs), wind power, and demand response (DR). Four PHEV charging scenarios are simulated for the Illinois power system: (1) unconstrained charging, (2) 3-hour delayed constrained charging, (3) smart charging, and (4) smart charging with DR. The PHEV charging is assumed to be optimally controlled by the system operator in the latter two scenarios, along with load shifting and shaving enabled by DR programs. The simulation results show that optimally dispatching the PHEV charging load can significantly reduce the total operating cost of the system. With DR programs in place, the operating cost can be further reduced.

17 WIND ENERGY↗

Optimizing HVAC Operations in Multi-unit Buildings for Grid Demand Response

The thermal inertia of buildings, along with the flexibility associated with thermostatically controlled loads (TCL) allows heating ventilation and cooling (HVAC) systems to be used for grid demand response (DR). In this work, we consider an HVAC system that serves multiple units in a residential building to meet their space heating requirements. We aim to determine the optimal power flow to each unit that minimizes the power costs incurred by the building's occupants while keeping in consideration their thermal comfort. The DR program is assumed to allow the building temperatures to deviate from the set-points up to a maximum limit. Despite the complex, non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using quadratic programming. Since HVAC systems can run on either electricity or natural gas, we study the efficacy of the DR regime for both hourly electricity prices and flat gas prices over the course of 24 hours. Finally, we run simulations to determine the optimal thermal power and the evolution of unit temperatures for various energy pricing schemes.

Naqvi, Syed A.↗

EFFORT (EFFectiveness Of Rate sTructure for enabling demand response)

This tool helps utilities evaluate potential time of use price-plans and find effective hours for price plan on peak periods and the potential price-elastic demand response. An optimization model can be used to find tiered prices for the time of use tariffs and analyze the impact on load profiles, energy consumption, utility, and customer savings. The tool is equipped with an optimization model to determine the energy consumption of electric appliances that can leverage survey data containing information on the number of appliances owned by customers. Lastly, a statistical model can be used to predict system-level load based on exogenous parameters such as weather, time of day, month, type of day, and year. The tool is scripted in Python and uses the Pyomo python optimization language.

Duwadi, Kapil↗

Evaluating demand response opportunities for power systems resilience using MILP and MINLP Formulations

While peak shaving is commonly used to reduce power costs, chemical process facilities that can reduce power consumption on demand during emergencies (e.g., extreme weather events) bring additional value through improved resilience. For process facilities to effectively negotiate demand response (DR) contracts and make investment decisions regarding flexibility, they need to quantify their additional value to the grid. We present a grid–centric mixed–integer stochastic programming framework to determine the value of DR for improving grid resilience in place of capital investments that can be cost prohibitive for system operators. We formulate problems using both a linear approximation and a nonlinear alternating current power flow model. Our numerical results with both models demonstrate that DR can be used to reduce the capital investment necessary for resilience, increasing the value that chemical process facilities bring through DR. Furthermore, the linearized model often underestimates the amount of DR needed in our case studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DReAM: Demand Response Architecture for Multi-level District Heating and Cooling Networks

In this paper, we exploit the inherent hierarchy of heat exchangers in District Heating and Cooling (DHC) networks and propose DReAM, a novel Demand Response (DR) architecture for Multi-level DHC networks. DReAM serves to economize system operation while still respecting comfort requirements of individual consumers. Contrary to many present day DR schemes that work on a consumer level granularity, DReAM works at a level of hierarchy above buildings, i.e. substations that supply heat to a group of buildings. This improves the overall DR scalability and reduce the computational complexity. In the first step of the proposed approach, mathematical models of individual substations and their downstream networks are abstracted into appropriately constructed low-complexity structural forms. In the second step, this abstracted information is employed by the utility to perform DR optimization that determines the optimal heat inflow to individual substations rather than buildings, in order to achieve the targeted objectives across the network. We validate the proposed DReAM framework through experimental results under different scenarios on a test network.

Bhattacharya, Saptarshi↗

Load Reduction, Demand Response and Energy Efficient Technologies and Strategies

The Department of Energy’s (DOE’s) Pacific Northwest National Laboratory (PNNL) was tasked by the DOE Office of Electricity (OE) to recommend load reduction and grid integration strategies, and identify additional demand response (energy efficiency/conservation opportunities) and strategies at the Forest City Housing (FCH) redevelopment at Pearl Harbor and the Marine Corps Base Hawaii (MCBH) at Kaneohe Bay. The goal was to provide FCH staff a path forward to manage their electricity load and thus reduce costs at these FCH family housing developments. The initial focus of the work was at the MCBH given the MCBH has a demand-ratchet tariff, relatively high demand (~18 MW) and a commensurate high blended electricity rate (26 cents/kWh). The peak demand for MCBH occurs in July-August. And, on average, family housing at MCBH contributes ~36% to the MCBH total energy consumption. Thus, a significant load reduction in family housing can have a considerable impact on the overall site load. Based on a site visit to the MCBH and meetings with MCBH installation, FCH, and Hawaiian Electric Company (HECO) staff, recommended actions (including a "smart grid" recommendation) that can be undertaken by FCH to manage and reduce peak-demand in family housing are made. Recommendations are also made to reduce overall energy consumption, and thus reduce demand in FCH family housing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determining and Unlocking Untapped Demand-Side Management Potential in South Africa: Demand Response at the Grid Edge

The National Renewable Energy Laboratory (NREL), funded through the Climate Technology and Change Network (CTCN), has provided technical assistance to key energy sector entities in South Africa to examine untapped demand-side management potential. NREL partnered with the Council for Scientific and Industrial Research (CSIR) and included key South Africa stakeholders: Eskom, the South African National Energy Development Institute (SANEDI), and the Department of Mineral and Resources and Energy (DMRE), including the CTCN National Designated Entity (NDE), the Department of Science and Innovation (DSI). South Africa is currently experiencing an energy crisis with extensive load shedding. While the load shedding crisis in South Africa is a supply side problem, demand-side management provides opportunities to achieve energy efficiency and to reduce peak demand. DSM also has huge potential to help alleviate load shedding, which is a last resort form of DSM.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency based electric vehicle charge controller system and method for implementing demand response and regulation services to power grid using frequency detection

Frequency responsive charging for plug-in hybrid electric vehicles (PHEV) and battery electric vehicles (BEV), a frequency sensing charging system and a method are provided for implementing demand response and regulation services to power grid using frequency detection for a frequency-based charge controller for plug-in hybrid electric vehicles (PHEV) and battery electric vehicles (BEV). A frequency of the power grid is continuously monitored and compared to a predefined tolerance band by a frequency sensor. Responsive to the frequency being outside the predefined tolerance band, the frequency is applied to a programmable logic controller. The programmable logic controller uses the applied frequency to identify a control action. A charge controller and a switch coupled to a battery charger receive respective identified control actions for controlling the battery charger.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Challenges to retail demand response program participation in ISO New England wholesale markets: Technical assistance provided to the New England Conference of Public Utilities Commissioners

Berkeley Lab provided technical assistance to the New England Conference of Public Utilities Commissioners on challenges that participants in retail demand response programs face to accessing ISO-NE wholesale markets. This report summarizes findings from the technical assistance and includes actions that New England regulators can take to address the challenges to wholesale market access.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Transactive Control of Commercial Buildings for Demand Response

Transactive control is a type of distributed control strategy that uses market mechanism to engage self-interested responsive loads to achieve power balance in the electrical power grid. In this paper, we propose a transactive control approach of commercial building Heating, Ventilation, and Air- Conditioning (HVAC) systems for demand response. We first describe the system models, and identify their model parameters using data collected from Systems Engineering Building (SEB) located on our Pacific Northwest National Laboratory (PNNL) campus. We next present a transactive control market structure for commercial building HVAC system, and describe its agent bidding and market clearing strategies. Several case studies are performed in a simulation environment using Building Control Virtual Test Bed (BCVTB) and calibrated SEB EnergyPlus model. We show that the proposed transactive control approach is very effective at peak clipping, load shifting, and strategic conservation for commercial building HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hardware-in-the-Loop Co-simulation of Distribution Grid for Demand Response

In modern power systems, co-simulation is proposed as an enabler for analyzing the interactions between disparate systems. This paper introduces the co-simulation platform Virtual Grid Integration Laboratory (VirGIL) including Hardware-in-the-Loop testing, and demonstrates its potential to assess demand response strategies. VirGIL is based on a modular architecture using the Functional Mock-up Interface industrial standard to integrate new simulators. VirGIL combines state-of-the-art simulators in power systems, communications, buildings, and control. In this work, VirGIL is extended with a Hardware-in-the-Loop component to control the ventilation system of a real 12-story building in Denmark. VirGIL capabilities are illustrated in three scenarios: load following, primary reserves and load following aggregation. Experimental results show that the system can track one minute changing signals and it can provide primary reserves for up-regulation. Furthermore, the potential of aggregating several ventilation systems is evaluated considering the impact at distribution grid level and the communications protocol effect.

Rotger-Griful, Sergi↗

Comparison of Demand Response Performance with an EnergyPlus Model in a Low Energy Campus Building

We have studied a low energy building on a campus of the University of California. It has efficient heating, ventilation, and air conditioning (HVAC) systems, consisting of a dual-fan/dual-duct variable air volume (VAV) system. As a major building on the campus, it was included in two demand response (DR) events in the summers of 2008 and 2009. With chilled water supplied by thermal energy storage in the central plant, cooling fans played a critical role during DR events. In this paper, an EnergyPlus model of the building was developed and calibrated. We compared both whole-building and HVAC fan energy consumption with model predictions to understand why demand savings in 2009 were much lower than in 2008. We also used model simulations of the study building to assess pre-cooling, a strategy that has been shown to improve demand saving and thermal comfort in many types of building. This study indicates a properly calibrated EnergyPlus model can reasonably predict demand savings from DR events and can be useful for designing or optimizing DR strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Examining Uncertainty in Demand Response Baseline Models and Variability in Automated Response to Dynamic Pricing

Controlling electric loads to deliver power system services presents a number of interesting challenges. For example, changes in electricity consumption of Commercial and Industrial (C&I) facilities are usually estimated using counterfactual baseline models, and model uncertainty makes it difficult to precisely quantify control responsiveness. Moreover, C&I facilities exhibit variability in their response. This paper seeks to understand baseline model error and demand-side variability in responses to open-loop control signals (i.e. dynamic prices). Using a regression-based baseline model, we define several Demand Response (DR) parameters, which characterize changes in electricity use on DR days, and then present a method for computing the error associated with DR parameter estimates. In addition to analyzing the magnitude of DR parameter error, we develop a metric to determine how much observed DR parameter variability is attributable to real event-to-event variability versus simply baseline model error. Using data from 38 C&I facilities that participated in an automated DR program in California, we find that DR parameter errors are large. For most facilities, observed DR parameter variability is likely explained by baseline model error, not real DR parameter variability; however, a number of facilities exhibit real DR parameter variability. In some cases, the aggregate population of C&I facilities exhibits real DR parameter variability, resulting in implications for the system operator with respect to both resource planning and system stability.

24 POWER TRANSMISSION AND DISTRIBUTION↗