Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “deformation estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Effects of Environmental Conditions on the Mechanical and Degradation Behavior of Polyurethane Foam Subjected to Various Deformation Histories

Since its development, polyurethane foam (PUF) has been widely used as an insulator, including in the marine industry. Liquefied natural gas (LNG) carriers have the highest market share in the LNG-related shipbuilding industry. PUF is used as an insulator in membrane-type cargo containment systems (CCSs) as one of the most important components of LNG carriers. Because PUF is subjected to constant load and deformation when used in insulation for LNG CCSs and is exposed to the cryogenics of the seawater environment for extended times, it is essential to evaluate the mechanical behavior of PUF in such environments. In this study, to investigate the effects of applying an initial strain and of immersion in various media on the mechanical properties of PUF, compression tests were carried out at ambient and cryogenic temperature using a universal testing machine. The mechanical behavior of PUF after deformation recovery upon subjection to various initial strain levels was estimated experimentally. In addition, the microstructure of the PUF specimen prior to testing was analyzed to investigate the effects of the initial strain level and immersion in different media on the mechanical behavior of PUF.

36 MATERIALS SCIENCE↗

Atomic and Molecular Adsorption on Re(0001)

Using periodic, self-consistent density functional theory calculations, the adsorption of several atomic (H, S, N, O and C) and molecular (CO2, N2, NH3, HCN, CO and NO) species and molecular fragments (NH2, NH, CN, CNH2, HNO, NOH, CH3, CH2, CH and OH) on the (0001) facet of rhenium at a coverage of 0.25 ML has been studied. Preferred binding sites with their corresponding binding energy and deformation energy of the surface, as well as an estimated diffusion barrier of each species have been determined. Atomic species and molecular fragments tend to bind to threefold sites, whereas molecular species tend to bind to top sites. The binding strength, with respect to the corresponding gas phase species and in increasing order for all species studied, is: CO2 < N2 < NH3 < CO < CH3 < HCN < NO < H < NH2 < OH < CH2 < CNH2 < CN < HNO < NH < NOH < S < N < O < CH < C. The vibrational frequencies of all species in their most energetically favorable adsorbed configuration have been calculated. Finally, the thermochemistry of adsorption and decomposition of NO, NO + H, NH3, N2, CO2, CO and CH4 on Re(0001) has been analyzed.

Environmental Molecular Sciences Laboratory↗

Theoretical estimate of the effect of thermal agitation on ribosome motion generated by stochastic microswimming

The effect of thermal agitation on ribosome motion is evaluated through the Péclet number, assuming that the ribosome is self-propelled along the mRNA during protein synthesis by a swimming stroke consisting of a cycle of stochastically-generated ribosome configurations involving its two subunits. The ribosome velocity probability distribution function is obtained, giving an approximately normal distribution. Its mean and variance together with an estimate of the in vivo free diffusion coefficient of the ribosome and using only configuration changes of small size, give a Péclet number similar to motor proteins and microorganisms. These results suggest the feasibility of the stochastic microswimming hypothesis to explain ribosome motion. - Highlights: • Hypothesis: the ribosome swims along the mRNA during protein synthesis. • How can withstand the thermal agitation of the particles in the surrounding fluid? • The Péclet number Pe is calculated estimating the in vivo diffusion coefficient. • With small size deformations the ribosome has speeds similar to motor proteins. • Similar Pe values for the ribosome and the motor proteins mean feasible hypothesis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of Quasielastic Barrier Distributions as a Step towards the Synthesis of Superheavy Elements with Hot Fusion Reactions

The excitation functions for quasielastic scattering of Ne 22 + Cm 248 , Mg 26 + Cm 248 , and Ca 48 + U 238 are measured using a gas-filled recoil ion separator. The quasielastic barrier distributions are extracted for these systems and are compared with coupled-channel calculations. The results indicate that the barrier distribution is affected dominantly by deformation of the actinide target nuclei, but also by vibrational or rotational excitations of the projectile nuclei, as well as neutron transfer processes before capture. From a comparison between the experimental barrier distributions and the evaporation residue cross sections for Sg ( Z = 106 ), Hs (108), Cn (112), and Lv (116), it is suggested that the hot fusion reactions take advantage of a compact collision, where the projectile approaches along the short axis of a prolately deformed nucleus. Overall, a new method is proposed to estimate the optimum incident energy to synthesize unknown superheavy nuclei using the barrier distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TH-EF-207A-05: Feasibility of Applying SMEIR Method On Small Animal 4D Cone Beam CT Imaging

Purpose: Small animal cone beam CT imaging has been widely used in preclinical research. Due to the higher respiratory rate and heat beats of small animals, motion blurring is inevitable and needs to be corrected in the reconstruction. Simultaneous motion estimation and image reconstruction (SMEIR) method, which uses projection images of all phases, proved to be effective in motion model estimation and able to reconstruct motion-compensated images. We demonstrate the application of SMEIR for small animal 4D cone beam CT imaging by computer simulations on a digital rat model. Methods: The small animal CBCT imaging system was simulated with the source-to-detector distance of 300 mm and the source-to-object distance of 200 mm. A sequence of rat phantom were generated with 0.4 mm{sup 3} voxel size. The respiratory cycle was taken as 1.0 second and the motions were simulated with a diaphragm motion of 2.4mm and an anterior-posterior expansion of 1.6 mm. The projection images were calculated using a ray-tracing method, and 4D-CBCT were reconstructed using SMEIR and FDK methods. The SMEIR method iterates over two alternating steps: 1) motion-compensated iterative image reconstruction by using projections from all respiration phases and 2) motion model estimation from projections directly through a 2D-3D deformable registration of the image obtained in the first step to projection images of other phases. Results: The images reconstructed using SMEIR method reproduced the features in the original phantom. Projections from the same phase were also reconstructed using FDK method. Compared with the FDK results, the images from SMEIR method substantially improve the image quality with minimum artifacts. Conclusion: We demonstrate that it is viable to apply SMEIR method to reconstruct small animal 4D-CBCT images.

60 APPLIED LIFE SCIENCES↗

Distribution of Slip at the Northern Sumatran Fault System

We model spatial variations in horizontal displacements of 117 geodetic sites measured during annual surveys in 1989-1996 with the Global Positioning System (GPS) as elastic strain across a locked strike-slip fault to infer the contemporary slip rate, locking depth, and location of the Sumatran fault (SF) in northern Sumatra (1 S-3 N). GPS-derived slip rate estimates increase slightly northward from 23 plus or minus 3 mm/yr at 0.8 deg S to 26 plus or minus 2mm/yr at 2.7 N. They agree with geologic estimates north of the Equator, but at 0.5 S they are about 10 mm/yr higher. Strain appears to be distributed asymmetrically about the fault. South of 2 N, about 5 mm/yr of shear is required within the offshore forearc, west of the fault, to achieve a closer agreement of fault locations inferred from GPS velocities with geologically identified traces of the SF. Locking depth estimates are on the order of 10-20 km. The western branch of the major fault bifurcation near 1 N slips at a rate five times higher than the eastern branch. The two main strands of the fault at the northwestern tip of Sumatra (5.5 N) appear to be nearly free of horizontal strain; significant slip must occur away from the two strands, probably further east at two other geologically active branches. The Banda Aceh embayment is extruded to the northwest at a rate of 5 plus or minus 2 mm/yr. Within the estimated velocity uncertainties of several mm/yr, fault-normal deformation along the SF is insignificant. Almost strain free, the northern part of the back-arc basin is part of a rigid Sunda shelf, while the northern forearc is subjected to 8 plus or minus 5 x 10 (exp -8)/yr of extension nearly parallel to the arc.

Genrich, J. F.↗

Popcorning Failures in Polymer and MnO2 Tantalum Capacitors

Popcorning is a well-known effect in plastic encapsulated microcircuits (PEM) and it occurs in chip tantalum capacitors. The sensitivity of components to the presence of moisture during soldering is characterized by the moisture sensitivity level (MSL); however, contrary to PEMs, there is no standard procedure for establishing MSL for tantalum capacitors.The effect of absorbed moisture on soldering related degradation and failures in tantalum capacitors have not been studied properly yet, and there is no sufficient information regarding the difference in the sensitivity to soldering between polymer and MnO2 capacitors. In this work, 16 types of polymer and 9 types of MnO2 tantalum capacitors with different moisture content have been tested before and after reflow soldering. The level of moisture release during soldering has been estimated and thermo-mechanical analysis used to assess deformation of capacitorsduring soldering simulations. Results show that moisture uptake in similar parts is approximately two times greater in polymer than in MnO2 capacitors. Cracking of the case and degradation of parameters can occur in both types of parts, but MnO2 capacitors are much more likely to fail catastrophically with a short circuit and possible ignition during the first power-on cycle. This type of failure in MnO2 capacitors is lot-related, can occur even at derated voltages and relatively low levels of moisture sorption that corresponds to room conditions. Baking before soldering is an effective measure to prevent failures even in lots susceptible to popcorning damage.

Capacitor↗

Effect of Soldering on Polymer and MnO2 Tantalum Capacitors

Soldering might have a strong effect on performance and reliability of most surface mount technology components, including tantalum capacitors. High quality tantalum capacitors are likely the only type of components where soldering simulation is the first step during screening. Nevertheless, post-soldering failures of tantalum capacitors happen and require additional analysis. Popcorning is a well-known effect in plastic encapsulated microcircuits (PEM) and it occurs also in chip tantalum capacitors. The sensitivity of parts to the presence of moisture during soldering is characterized by the moisture sensitivity level (MSL); however, contrary to PEMs, there is no standard procedure for establishing MSL for tantalum capacitors. The effect of absorbed moisture on soldering related degradation and failures in tantalum capacitors have not been studied properly yet, and there is no sufficient information regarding the difference in the sensitivity to soldering between polymer and MnO2 tantalum capacitors. In this work, 16 types of polymer and 9 types of MnO2 cathodes tantalum capacitors with different moisture content have been tested before and after reflow soldering. The level of moisture release after soldering has been estimated and thermo-mechanical analysis used to assess deformation of capacitors during soldering simulations. Results show that moisture uptake in similar parts is approximately two times greater in polymer than in MnO2 capacitors. Cracking of the case and degradation of parameters can occur in both types of parts, but MnO2 capacitors are much more likely to fail catastrophically with a short circuit and possible ignition during the first power-on cycle. This type of failure in MnO2 capacitors is lot-related, can occur even at derated voltages and relatively low levels of moisture sorption corresponding to room conditions. Baking before soldering is an effective measure to prevent failures even in lots susceptible to popcorning damage. Recommendations for baking and testing to establish MSL are suggested.

Alexander Teverovsky↗

Toward adaptive radiotherapy for head and neck patients: Feasibility study on using CT-to-CBCT deformable registration for “dose of the day” calculations

Purpose: The aim of this study was to evaluate the appropriateness of using computed tomography (CT) to cone-beam CT (CBCT) deformable image registration (DIR) for the application of calculating the “dose of the day” received by a head and neck patient. Methods: NiftyReg is an open-source registration package implemented in our institution. The affine registration uses a Block Matching-based approach, while the deformable registration is a GPU implementation of the popular B-spline Free Form Deformation algorithm. Two independent tests were performed to assess the suitability of our registrations methodology for “dose of the day” calculations in a deformed CT. A geometric evaluation was performed to assess the ability of the DIR method to map identical structures between the CT and CBCT datasets. Features delineated in the planning CT were warped and compared with features manually drawn on the CBCT. The authors computed the dice similarity coefficient (DSC), distance transformation, and centre of mass distance between features. A dosimetric evaluation was performed to evaluate the clinical significance of the registrations errors in the application proposed and to identify the limitations of the approximations used. Dose calculations for the same intensity-modulated radiation therapy plan on the deformed CT and replan CT were compared. Dose distributions were compared in terms of dose differences (DD), gamma analysis, target coverage, and dose volume histograms (DVHs). Doses calculated in a rigidly aligned CT and directly in an extended CBCT were also evaluated. Results: A mean value of 0.850 in DSC was achieved in overlap between manually delineated and warped features, with the distance between surfaces being less than 2 mm on over 90% of the pixels. Deformable registration was clearly superior to rigid registration in mapping identical structures between the two datasets. The dose recalculated in the deformed CT is a good match to the dose calculated on a replan CT. The DD is smaller than 2% of the prescribed dose on 90% of the body's voxels and it passes a 2% and 2 mm gamma-test on over 95% of the voxels. Target coverage similarity was assessed in terms of the 95%-isodose volumes. A mean value of 0.962 was obtained for the DSC, while the distance between surfaces is less than 2 mm in 95.4% of the pixels. The method proposed provided adequate dose estimation, closer to the gold standard than the other two approaches. Differences in DVH curves were mainly due to differences in the OARs definition (manual vs warped) and not due to differences in dose estimation (dose calculated in replan CT vs dose calculated in deformed CT). Conclusions: Deforming a planning CT to match a daily CBCT provides the tools needed for the calculation of the “dose of the day” without the need to acquire a new CT. The initial clinical application of our method will be weekly offline calculations of the “dose of the day,” and use this information to inform adaptive radiotherapy (ART). The work here presented is a first step into a full implementation of a “dose-driven” online ART.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Failure Analysis for Molten Salt Thermal Energy Storage Tanks for In-Service CSP Plants

Thermal Energy Storage (TES) is a fundamental component in concentrating solar power (CSP) plants to increase the plant's dispatchability, capacity factor, while reducing the levelized cost of electricity. In central receivers CSP plants, nitrate molten salts have been used for several years for operation temperatures of up to 565 degrees C. Despite many efforts to advance nitrate salt to higher operation temperatures (even considering a replacement with molten chloride salts) to achieve higher energy conversion efficiencies, the 565 degrees C temperature is currently considered the state-of-the art. Although molten salt tanks have been broadly deployed in commercial CSP plants worldwide, several failures have been reported in these tanks after a few months or years of operation, causing significant economic loss and mistrust in CSP technologies. Most of these failures are associated with the infancy of the technology and multiple issues related to tank design, fabrication, commissioning, and aggressive operation. A technical standard dedicated to the design and fabrication of molten nitrate TES tanks does not exist today. Current in-service molten salt tanks have been generally designed based on the American Petroleum Institute's (API) 650 and ASME Section II standards. The API 650 code provides guidelines for dimensions and fabrication for oil storage tanks up to 260 degrees C. The ASME standard provides allowable stress values for various materials at a range of temperatures and conditions. Both standards seem to be limited for molten salt TES tanks where high temperatures, thermal cycling, and transient conditions are expected. In 2020, NREL released the Concentrating Solar Power Best Practices Study (NREL/TP-5500-75763) that summarized multiple issues in CSP plants, along with potential alternatives and recommendations to address those issues based on information collected from participants representing about 80% of operating CSP plants in the world. One of the recommendations from this study was the development of accurate and validated models to evaluate the plant's transient operation, capable of capturing the effect of short-term clouds and operator response, while being flexible in being adapted to various spatial and temporal resource data. The "Failure Analysis for Molten Salt Thermal Energy Tanks for In-Service CSP Plants" project was inspired on this recommendation and was focused on (1) the development and validation of a physics-based model for a representative, commercial-scale molten salt tank, (2) performing simulations to evaluate the behavior of the tank as a function of typical plant operation conditions, (3) understanding tank failures mechanisms, (4) determining the residual stress and distortion in the tank floor after welding fabrication and evaluating their impact in the stresses developed in the tank during operation, (5) assessing the impact of key operation parameters on the temperature and stress distribution, (6) conduct a preliminary evaluation of design features to reduce stress and improve tank's reliability, and (7) estimate the tank's service life based on the stress developed under diverse operation scenarios. From the analysis conducted in the project and presented in this report, it was found that maximum stresses surpassing the yield strength point of the stainless steel (SS) 347H are developed on the tank floor near the perimeter. These large stresses are strongly influenced by the initial residual stresses and distortion of the tank floor after welding fabrication. During operation, large stresses are developed in the tank floor at high operation temperatures with large salt inventory levels during transient operation. High stresses are also related to elevated temperature gradients in the tank floor that could be attributed to insufficient mixing within the salt inflow and the salt inventory. Based on the analysis, creep is the predominant failure mechanism. However, the large stress levels could favor the plastic deformation into buckles, and crack formation due to stress relaxation cracking during cycle operation. A lifetime below 3 years was estimated for the typical plant operation conditions and a specific initial residual stress and deformation distribution of the tank floor. The estimated life agrees with the service time to failure reported in several commercial molten salt tanks. Desing and operation guidelines can be extracted from the analysis presented in this report, which could be adopted by tank manufacturers and CSP operators to advance toward an ultimate solution for tank failures by reducing residual and operational stresses to achieve a tank service life of more than 30 years. Addressing failures in molten salt TES tanks is fundamental for the CSP industry's survivability, but it is also important for other industrial and power generation applications using this technology, including nuclear and concentrating solar thermal.

14 SOLAR ENERGY↗

Mechanism-based constitutive modeling of ZEK100 magnesium alloy with crystal plasticity and in-situ HEXRD experiment

The constitutive behavior of a hexagonal close-packed (HCP) polycrystalline ZEK100 magnesium alloy was investigated here using combined high energy X-ray diffraction (HEXRD) from a synchrotron source and crystal plasticity modeling approach. The in-situ tensile test data coupled with the HEXRD enabled the tracking of the lattice strain evolution during deformation. The microscopic behavior represented by lattice strain and the macroscopic behavior represented by stress-strain curves were then used together as objective function to estimate the critical resolved shear stress (CRSS) and hardening parameters of available slip and deformation twin systems in the ZEK100 alloy. An enhanced predominant twinning reorientation (ePTR) scheme was proposed in the current work, and the ePTR parameters were determined for the first time by the use of basal plane peak intensity along loading direction measured from HEXRD. Two crystal plasticity models, the computationally efficient elastic-plastic self-consistent (EPSC) and crystal plasticity finite element (CPFE) models, were developed incorporating the deformation twinning for the HCP-structured metals. The determined constitutive parameters were further validated by comparing the predicted deformation texture with the measured one. The work provides a useful and computationally-efficient modeling scheme to understand the slip/twin induced deformation behaviors of the ZEK100 alloy in micro- and macro-scales.

36 MATERIALS SCIENCE↗

Motion tracking in the liver: Validation of a method based on 4D ultrasound using a nonrigid registration technique

Purpose: Treatments like radiotherapy and focused ultrasound in the abdomen require accurate motion tracking, in order to optimize dosage delivery to the target and minimize damage to critical structures and healthy tissues around the target. 4D ultrasound is a promising modality for motion tracking during such treatments. In this study, the authors evaluate the accuracy of motion tracking in the liver based on deformable registration of 4D ultrasound images. Methods: The offline analysis was performed using a nonrigid registration algorithm that was specifically designed for motion estimation from dynamic imaging data. The method registers the entire 4D image data sequence in a groupwise optimization fashion, thus avoiding a bias toward a specifically chosen reference time point. Three healthy volunteers were scanned over several breathing cycles (12 s) from three different positions and angles on the abdomen; a total of nine 4D scans for the three volunteers. Well-defined anatomic landmarks were manually annotated in all 96 time frames for assessment of the automatic algorithm. The error of the automatic motion estimation method was compared with interobserver variability. The authors also performed experiments to investigate the influence of parameters defining the deformation field flexibility and evaluated how well the method performed with a lower temporal resolution in order to establish the minimum frame rate required for accurate motion estimation. Results: The registration method estimated liver motion with an error of 1 mm (75% percentile over all datasets), which was lower than the interobserver variability of 1.4 mm. The results were only slightly dependent on the degrees of freedom of the deformation model. The registration error increased to 2.8 mm with an eight times lower temporal resolution. Conclusions: The authors conclude that the methodology was able to accurately track the motion of the liver in the 4D ultrasound data. The authors believe that the method has potential in interventions on moving abdominal organs such as MR or ultrasound guided focused ultrasound therapy and radiotherapy, pending the method is enabled to run in real-time. The data and the annotations used for this study are made publicly available for those who would like to test other methods on 4D liver ultrasound data.

60 APPLIED LIFE SCIENCES↗

4D dose-position verification in radiation therapy using the RADPOS system in a deformable lung phantom

Purpose: A novel 4D in vivo dosimetry system (RADPOS), in conjunction with a deformable lung phantom, has been evaluated as a potential quality assurance tool for 4D radiotherapy. Methods: RADPOS detectors, which consist of a MOSFET dosimeter combined with an electromagnetic positioning probe, were placed inside the deformable lung phantom. One detector was positioned directly inside a tumor embedded in the lung phantom and another was positioned inside the lung portion of the phantom, outside the tumor. CT scans were taken with the phantom at three breathing phases, and for each phase, the detector position inside the phantom was read with the RADPOS software and compared to the position as determined from the CT data. These values were also compared to RADPOS measurements taken with the phantom on the couch of a Varian Clinac 6EX linac. The deformable phantom and the RADPOS system were also used in two radiation delivery scenarios: (1) A simulation of a free-breathing delivery and (2) a simulation of an adaptive treatment. Results: Compared to CT imaging, the RADPOS positional accuracy was found to be better than 2.5 mm. The radial displacement measurements taken in the CT and linac rooms agreed to within an average of (0.7{+-}0.3) mm. Hence, the system can provide relative displacement measurements in the treatment room, consistent with measurements made in the CT room. For the free-breathing delivery, the total dose reported by RADPOS agreed to within 4% and 5% of the treatment planning doses in the tumor and the lung portion of the phantom, respectively. The RADPOS-measured dose values for the adaptive delivery were within 1.5% of the treatment plan values, which was well within the estimated experimental uncertainties. Conclusions: This work has shown that the deformable lung phantom-RADPOS system can be an efficient quality assurance tool for 4D radiation therapy.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRA-05: Fully Automatic Segmentation of Male Pelvic Organs On CT Without Manual Intervention

Purpose: We aim to develop a fully automatic tool for accurate contouring of major male pelvic organs in CT images for radiotherapy without any manual initialization, yet still achieving superior performance than the existing tools. Methods: A learning-based 3D deformable shape model was developed for automatic contouring. Specifically, we utilized a recent machine learning method, random forest, to jointly learn both image regressor and classifier for each organ. In particular, the image regressor is trained to predict the 3D displacement from each vertex of the 3D shape model towards the organ boundary based on the local image appearance around the location of this vertex. The predicted 3D displacements are then used to drive the 3D shape model towards the target organ. Once the shape model is deformed close to the target organ, it is further refined by an organ likelihood map estimated by the learned classifier. As the organ likelihood map provides good guideline for the organ boundary, the precise contouring Result could be achieved, by deforming the 3D shape model locally to fit boundaries in the organ likelihood map. Results: We applied our method to 29 previously-treated prostate cancer patients, each with one planning CT scan. Compared with manually delineated pelvic organs, our method obtains overlap ratios of 85.2%±3.74% for the prostate, 94.9%±1.62% for the bladder, and 84.7%±1.97% for the rectum, respectively. Conclusion: This work demonstrated feasibility of a novel machine-learning based approach for accurate and automatic contouring of major male pelvic organs. It shows the potential to replace the time-consuming and inconsistent manual contouring in the clinic. Also, compared with the existing works, our method is more accurate and also efficient since it does not require any manual intervention, such as manual landmark placement. Moreover, our method obtained very similar contouring results as the clinical experts. Project is partially support by a grant from NCI 1R01CA140413.

60 APPLIED LIFE SCIENCES↗

SU-E-J-101: Improved CT to CBCT Deformable Registration Accuracy by Incorporating Multiple CBCTs

Purpose: Combining prior day CBCT contours with STAPLE was previously shown to improve automated prostate contouring. These accurate STAPLE contours are now used to guide the planning CT to pre-treatment CBCT deformable registration. Methods: Six IGRT prostate patients with daily kilovoltage CBCT had their original planning CT and 9 CBCTs contoured by the same physician. These physician contours for the planning CT and each prior CBCT are deformed to match the current CBCT anatomy, producing multiple contour sets. These sets are then combined using STAPLE into one optimal set (e.g. for day 3 CBCT, combine contours produced using the plan plus day 1 and 2 CBCTs). STAPLE computes a probabilistic estimate of the true contour from this collection of contours by maximizing sensitivity and specificity. The deformation field from planning CT to CBCT registration is then refined by matching its deformed contours to the STAPLE contours. ADMIRE (Elekta Inc.) was used for this. The refinement does not force perfect agreement of the contours, typically Dice’s Coefficient (DC) of > 0.9 is obtained, and the image difference metric remains in the optimization of the deformable registration. Results: The average DC between physician delineated CBCT contours and deformed planning CT contours for the bladder, rectum and prostate was 0.80, 0.79 and 0.75, respectively. The accuracy significantly improved to 0.89, 0.84 and 0.84 (P<0.001 for all) when using the refined deformation field. The average time to run STAPLE with five scans and refine the planning CT deformation was 66 seconds on a Telsa K20c GPU. Conclusion: Accurate contours generated from multiple CBCTs provided guidance for CT to CBCT deformable registration, significantly improving registration accuracy as measured by contour DC. A more accurate deformation field is now available for transferring dose or electron density to the CBCT for adaptive planning. Research grant from Elekta.

60 APPLIED LIFE SCIENCES↗

Macroscopic detection of deformed QM by the harmonic oscillator

Based on the nonperturbative analysis, we show that the classical motion of harmonic oscillator derived from the deformed QM is manifestly in contradiction with observations (to the first order in deformation parameter as it has been pointed out in Bawaj et al. (2015)). For this reason, we take an alternate way for estimating the effect and discuss its possible observational manifestations in macrophysics. - Highlights: • The classical motion of harmonic oscillator is derived from deformed QM. • The classical limit is obviously inconsistent with observations. • The reason for this inconsistency is explained. • An alternate estimate of the effect is provided.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CONSTRAINTS ON THE SPACETIME GEOMETRY AROUND 10 STELLAR-MASS BLACK HOLE CANDIDATES FROM THE DISK'S THERMAL SPECTRUM

In a previous paper, one of us (C. Bambi) described a code to compute the thermal spectrum of geometrically thin and optically thick accretion disks around generic stationary and axisymmetric black holes, which are not necessarily of the Kerr type. As the structure of the accretion disk and the propagation of electromagnetic radiation from the disk to the distant observer depend on the background metric, the analysis of the thermal spectrum of thin disks can be used to test the actual nature of black hole candidates. In this paper, we consider the 10 stellar-mass black hole candidates for which the spin parameter has already been estimated from the analysis of the disk's thermal spectrum under the assumption of the Kerr background, and we translate the measurements reported in the literature into constraints on the spin parameter-deformation parameter plane. The analysis of the disk's thermal spectrum can be used to estimate only one parameter of the geometry close to the compact object; therefore, it is not possible to get independent measurements of both the spin and the deformation parameters. The constraints obtained here will be used in combination with other measurements in future work with the final goal of breaking the degeneracy between the spin and possible deviations from the Kerr solution and thus test the Kerr black hole hypothesis.

79 ASTRONOMY AND ASTROPHYSICS↗