Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data housing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Plant single-cell solutions for energy and the environment

Progress in sequencing, microfluidics, and analysis strategies has revolutionized the granularity at which multicellular organisms can be studied. In particular, single-cell transcriptomics has led to fundamental new insights into animal biology, such as the discovery of new cell types and cell type-specific disease processes. However, the application of single-cell approaches to plants, fungi, algae, or bacteria (environmental organisms) has been far more limited, largely due to the challenges posed by polysaccharide walls surrounding these species’ cells. In this perspective, we discuss opportunities afforded by single-cell technologies for energy and environmental science and grand challenges that must be tackled to apply these approaches to plants, fungi and algae. We highlight the need to develop better and more comprehensive single-cell technologies, analysis and visualization tools, and tissue preparation methods. We advocate for the creation of a centralized, open-access database to house plant single-cell data. Finally, we consider how such efforts should balance the need for deep characterization of select model species while still capturing the diversity in the plant kingdom. Investments into the development of methods, their application to relevant species, and the creation of resources to support data dissemination will enable groundbreaking insights to propel energy and environmental science forward.

59 BASIC BIOLOGICAL SCIENCES↗

Rolling Root Mean Square Based Multimodal Anomaly Detection for Real Time Monitoring of Smart Grid

Reliable real-time monitoring is valuable for maintaining the operational integrity of modern electrical smart grids. Deployment of heterogeneous sensing technologies in substations has enabled high-resolution, multichannel waveform monitoring, but also introduces challenges for anomaly detection due to noise, baseline drift, and modality-dependent signal characteristics. In this work, we present a computationally efficient unsupervised method for multimodal event detection based on Rolling Root Mean Square based Event Detection (RRMSED). The method is developed using in-house, field deployed sensors collecting data at a utility substation. The sensing system comprises voltage and current sensors, triaxial accelerometers, and magnetometers, collectively capturing electrical, vibrational, and magnetic waveform measurements at high temporal resolution. RRMSED operates by extracting rolling RMS energy features and their first-order temporal differences from consecutive waveform segments for each channel and then applying channel-specific statistical thresholds learned from historical data. A persistence-based exceedance logic is employed to robustly identify transient events while suppressing impulsive noise, and to provide precise temporal localization with high resolution. The framework is designed for continuous server-side operation and can be deployed in real time without requiring complex models. Experiments on simulated waveform data with known ground truth demonstrate low false positive (FP) and false negative (FN) rates. Application to real substation data shows RRMSED to identify events that are not captured by conventional monitoring indicators including fast transient detection algorithm currently deployed in the system. These results indicate that rolling RMS based features provide an effective and practical basis for real-time multimodal event detection in smart-grid substations.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗

Numerical Analysis of Fuel Effects on Advanced Compression Ignition Using a Cooperative Fuel Research Engine Computational Fluid Dynamics Model

Growing environmental concerns and demand for a better fuel economy are driving forces that motivate the research for more advanced engines. Multi-mode combustion strategies have gained attention for their potential to provide high thermal efficiency and low emissions for light-duty applications. These strategies target optimizing the engine performance by correlating different combustion modes to load operating conditions. The extension from boosted spark ignition (SI) mode at high loads to advanced compression ignition (ACI) mode at low loads can be achieved by increasing the compression ratio and utilizing intake air heating. Further, in order to enable an accurate control of intake charge condition for ACI mode and rapid mode-switches, it is essential to gain fundamental insights into the autoignition process. Within the scope of ACI, homogeneous charge compression ignition (HCCI) mode is of significant interest. It is known for its potential benefits, operation at low fuel consumption, low NOx, and particulate matter (PM) emissions. In the present work, a virtual Cooperative Fuel Research (CFR) engine model is used to analyze fuel effects on ACI combustion. In particular, the effect of fuel octane sensitivity (S) (at constant Research Octane Number (RON)) on autoignition propensity is assessed under beyond-RON (BRON) and beyond-MON (BMON) ACI conditions. The three-dimensional CFR engine computational fluid dynamics (CFD) model employs a finite-rate chemistry approach with a multi-zone binning strategy to capture autoignition. Two binary blends with Research Octane Number (RON) of 90 are chosen for this study: primary reference fuel (PRF) with S = 0 and toluene–heptane (TH) blend with S = 10.8, representing paraffinic and aromatic gasoline surrogates. Reduced mechanisms for these blends are generated from a detailed gasoline surrogate kinetic mechanism. Simulation results with the reduced mechanisms are validated against experimental data from an in-house CFR engine, with respect to in-cylinder pressure, heat release rate, and combustion phasing. Thereafter, the sensitivity of combustion behavior to ACI operating condition (BRON versus BMON), air-fuel ratio (λ = 2 and 3), and engine speed (600 and 900 rpm) is analyzed for both fuels. It is shown that the sensitivity of a fuel’s autoignition characteristics to λ and engine speed significantly differs at BRON and BMON conditions. Moreover, this sensitivity is found to vary among fuels, despite the same RON. It is also observed that the presence of low-temperature heat release (LTHR) under BRON condition leads to more sequential autoignition and longer combustion duration than BMON condition. Finally, the study indicates that the octane index (OI) fails to capture the trend in the variation of autoignition propensity with S under the BMON condition.

33 ADVANCED PROPULSION SYSTEMS↗

SU-E-T-82: A Study On Enhanced Dynamic Wedge (EDW) Dosimetry Using 2D Seven29 Ion Chamber Array Detector

Purpose: To study the dosimetric properties of Enhanced Dynamic Wedge (EDW) using PTW Seven29 ion chamber array Methods: PTW Seven29 ion chamber array and Solid Water phantoms for different depths were used for the study. The study was carried out in Varian Clinac ix with photon energies, 6MV & 15MV. Primarily the solid water phantoms with the 2D array were scanned using a CT scanner (GE Optima 580) at different depths. These scanned images were used for EDW planning in an Eclipse treatment planning system (version 10). Planning was done for different wedge angles and for different depths for 6MV & 15MV. A dose of 100 CGy was delivered in each cases. For each delivery, calculated the Monitoring Unit (MU) required. Same set-up was created before delivering the plans in Varian Clinac-ix. For each clinically relevant depth and for different wedge angles, the same MU was delivered as calculated. Different wedged dose distributions where reconstructed from the measured 2D array data using the in-house developed excel program. Results: It is observed that the shoulder like region in the profile which reduces as depth increases. For the same depth and energy, the percentage difference between planned and measured dose is lesser than 3%. For smaller wedge angles, the percentage difference is found to be greater than 3% for the largest wedge angle. Standard deviation between measured doses at shoulder region for planned and measured profiles is 0.08 and 0.02 respectively. Standard deviations between planned and measured wedge factors for different depths (2.5cm, 5cm, 10cm, and 15cm) are (0.0021, 0.0007, 0.0050, 0.0001) for 6MV and (0.0024, 0.0191, 0.0013, 0.0005) for 15MV respectively. Conclusion: The 2D Seven29 ion chamber array is a good tool for the Enhanced Dynamic Wedge (EDW) dosimetry.

60 APPLIED LIFE SCIENCES↗

SU-F-T-259: GPR Tables for the Estimation of Mid-Plane Dose Using EPID

Purpose: To develop a simple method for estimating the mid-plane dose (MPD) of a patient using Electronic Portal imaging Device (EPID). Methods: A Varian TrueBeam with aSi100 EPID was used in this study. The EPID images were acquired for a 30 cm × 30 cm homogeneous slab phantom and a 30 cm diameter 20 cm thick cylindrical phantom in the continuous dosimetry mode. The acquired EPID images in XIM format were imported into in-house MATLAB program for the data analysis. First, the dosimetric characteristics of EPID were studied for dose-response linearity, dose-rate dependence, and field size dependence. Next, the average pixels values of the EPID images were correlated with the MPD measured by an ionisation chamber for various thicknesses of the slab phantom (8 cm – 30 cm) and for various square field sizes (3×3 cm{sup 2} – 25×25 cm{sup 2} at the isocenter). Look-up tables called as GPR tables were then generated for both SSD and SAD setup by taking the ratio of MPD measured by the ionisation chamber and the corresponding EPID pixel values. The accuracy of the GPR tables was evaluated by varying the field size, phantom thickness, and wedge angles with the slab and cylindrical phantoms. Results: The dose response of EPID was linear from 20 MU to 300 MU. The EPID response for different dose rates from 40 MU/min to 600 MU/min was within ±1%. The difference in the doses from the GPR tables and the doses measured by the ionization chambers were within 2% for slab phantoms, and 3% for the cylindrical phantom for various field sizes, phantom thickness, and wedge angles. Conclusion: GPR tables are a ready reckoner for in-vivo dosimetry and it can be used to quickly estimate the MPD value from the EPID images with an accuracy of ±3% for common clinical treatment. project work funded by Union for International cancer control(UICC) under ICRETT fellowship.

60 APPLIED LIFE SCIENCES↗

SU-F-T-477: Investigation of DEFGEL Dosimetry Using MRI

Purpose: The DEFGEL dosimeter/phantom allows for the measurement of 3D dose distributions while maintaining tissue equivalence and deformability. Although DEFGEL is traditionally read out with optical CT, the use of MRI would permit the measurement of 3D dose distributions in optically interfering configurations, like while embedded in a phantom. To the knowledge of the authors, this work is the first investigation that uses MRI to measure dose distributions in DEFGEL dosimeters. Methods: The DEFGEL (6%T) formula was used to create 1 cm thick, 4.5 cm diameter cylindrical dosimeters. The dosimeters were irradiated using a Varian Clinac 21EX linac. The MRI based transverse relaxation rate (R2) of the gel was measured in a central slice of the dosimeter with a Spin-Echo (SE) pulse sequence on a 3T GE SIGNA PET/MR scanner. The R2 values were fit to a monoexponential dose response equation using in-house software (MATLAB). Results: The data was well fit using a monoexponential fit for R2 as a function of absorbed dose (R{sup 2} = 0.9997). The fitting parameters of the monoexponential fit resulted in a 0.1229 Gy{sub −1}s{sub −1} slope. The data also resulted in an average standard deviation of 1.8% for the R2 values within the evaluated ROI. Conclusion: The close fit for the dose response curve shows that a DEFGEL based dosimeter can be paired with a SE MRI acquisition. The Type A uncertainty of the MRI method shows adequate precision, while the slope of the fit curve is large enough that R2 differences between different gel doses are distinguishable. These results suggest that the gel could potentially be used in configurations where an optical readout is not viable, such as measurements with the gel dosimeter positioned inside larger or optically opaque phantoms. This work is partially funded by NIH grant R01CA190298.

60 APPLIED LIFE SCIENCES↗

Datasets for IWG Report on Energy Communities

Datasets associated with figures in the Initial Report to the President on Empowering Workers Through Revitalizing Energy Communities (available at: https://netl.doe.gov/sites/default/files/2021-04/Initial%20Report%20on%20Energy%20Communities_Apr2021.pdf) from the Interagency Working Group for Coal and Power Plant Communities. These data align to the White House’s The Interagency Working Group on Coal and Power Plant Communities and Economic Revitalization, https://energycommunities.gov/

Coal,Fossil Energy,Jobs and Employment,United Stat↗

Implementation of the Windowed Multipole Method in Shift

The windowed multipole (WMP) method has been implemented in the Shift Monte Carlo (MC) radiation transport code with support for both CPU and GPU execution. With this method, small WMP data libraries (~100 MB) can be used to accurately Doppler broaden cross sections to arbitrary temperatures “on the fly” during an MC simulation. This approach yields significant memory savings relative to traditional methods, making it ideal for high-fidelity analysis such as coupled multiphysics simulations. This document provides the exact forms of the WMP equations used by Shift, as well as a detailed description of the structure of WMP HDF5 data files provided by the Massachusetts Institute of Technology (MIT). The Shift implementation has been validated against the OpenMC radiation transport code, with excellent agreement demonstrated for 70 nuclides across an operative range of temperatures. CPU and GPU performance testing using a small module reactor (SMR) problem demonstrated that this method decreases the neutron tracking rate by a factor of ~2 on the Summitdev machine. A new set of WMP data being developed in-house will employ novel methods to improve tracking rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Conservation of Modules but not Phenotype in Bacterial Response to Environmental Stress

Microbes live in changing environments and change their phenotype via gene regulation in response. Although this transcriptional response is important for fitness, very little is known about how it evolves in microbes. We started by asking a number of high-level questions about the evolution of transcriptional phenotype: (1) To what extent is transcriptional response conserved, i.e. do conserved genes respond similarly to the same condition; (2) To what extent are transcriptional modules conserved; and (3) Does there exist a general stress response to a variety of stressors? To illuminate these questions, we analyzed more than 500 microarray experiments across the bacterial domain. We looked for conservation of transcriptional regulation both in close sister species and vastly divergent clades. In addition, we produced and analyzed an extensive in-house compendium of environmental stress data in three metal-reducing bacteria.

54 ENVIRONMENTAL SCIENCES↗

Test report: Shock test of the electron/proton spectrometer structural test unit

A shock test of the electron-proton spectrometer structural test unit was conducted. The purpose of the shock test was to verify the structural integrity of the electron-spectrometer design and to obtain data on the shock response of the electronics and electronic housing. The test equipment is described and typical shock response data are provided.

Vincent, D. L.↗

Hybrid upper surface blown flap propulsive-lift concept for the quiet short-haul research aircraft

The hybrid upper surface blowing concept consists of wing-mounted turbofan engines with a major portion of the fan exhaust directed over the wing upper surface to provide high levels of propulsive lift, but with a portion of the fan airflow directed over selected portions of the airframe to provide boundary layer control. NASA-sponsored preliminary design studies identified the hybrid upper surface blowing concept as the best propulsive lift concept to be applied to the Quiet Short-Haul Research Aircraft (QSRA) that is planned as a flight facility to conduct flight research at low noise levels high approach lift coefficients, and steep approaches. Data from NASA in-house and NASA-sponsored small and large-scale wind tunnel tests of various configurations using this concept are presented.

Cochrane, J. A.↗

Hybrid upper surface blown flap propulsive-lift concept for the Quiet Short-Haul Research Aircraft

The hybrid upper surface blowing concept consists of wing-mounted turbofan engines with a major portion of the fan exhaust directed over the wing upper surface to provide high levels of propulsive lift, but with a portion of the fan airflow directed over selected portions of the airframe to provide boundary layer control. NASA-sponsored preliminary design studies identified the hybrid upper surface blowing concept as the best propulsive lift concept to be applied to the Quiet Short-Haul Research Aircraft (QSRA) that is planned as a flight facility to conduct flight research at low noise levels, high approach lift coefficients, and steep approaches. Data from NASA in-house and NASA-sponsored small and large-scale wind tunnel tests of various configurations using this concept are presented.

Cochrane, J. A.↗

Electronic Components and Systems for Cryogenic Space Applications

Electronic components and systems capable of operation at cryogenic temperatures are anticipated in many future NASA space missions such as deep space probes and planetary surface exploration. For example, an unheated interplanetary probe launched to explore the rings of Saturn would reach an average temperature near Saturn of about - 183 C. In addition to surviving the deep space harsh environment, electronics capable of low temperature operation would contribute to improving circuit performance, increasing system efficiency, and reducing payload development and launch costs. Terrestrial applications where components and systems must operate in low temperature environments include cryogenic instrumentation, superconducting magnetic energy storage, magnetic levitation transportation system, and arctic exploration. An on-going research and development program at the NASA Glenn Research Center focuses on the development of reliable electronic devices and efficient power systems capable of surviving in low temperature environments. An overview of the program will be presented in this paper. A description of the low temperature test facilities along with selected data obtained from in-house component testing will also be discussed. Ongoing research activities that are being performed in collaboration with various organizations will also be presented.

Patterson, R. L.↗

Electronic Components and Circuits for Extreme Temperature Environments

Planetary exploration missions and deep space probes require electrical power management and control systems that are capable of efficient and reliable operation in very low temperature environments. Presently, spacecraft operating in the cold environment of deep space carry a large number of radioisotope heating units in order to maintain the surrounding temperature of the on-board electronics at approximately 20 C. Electronics capable of operation at cryogenic temperatures will not only tolerate the hostile environment of deep space but also reduce system size and weight by eliminating or reducing the radioisotope heating units and their associate structures; thereby reducing system development as well as launch costs. In addition, power electronic circuits designed for operation at low temperatures are expected to result in more efficient systems than those at room temperature. This improvement results from better behavior and tolerance in the electrical and thermal properties of semiconductor and dielectric materials at low temperatures. The Low Temperature Electronics Program at the NASA Glenn Research Center focuses on research and development of electrical components, circuits, and systems suitable for applications in the aerospace environment and deep space exploration missions. Research is being conducted on devices and systems for reliable use down to cryogenic temperatures. Some of the commercial-off-the-shelf as well as developed components that are being characterized include switching devices, resistors, magnetics, and capacitors. Semiconductor devices and integrated circuits including digital-to-analog and analog-to-digital converters, DC/DC converters, operational amplifiers, and oscillators are also being investigated for potential use in low temperature applications. An overview of the NASA Glenn Research Center Low Temperature Electronic Program will be presented in this paper. A description of the low temperature test facilities along with selected data obtained through in-house component and circuit testing will also be discussed. Ongoing research activities that are being performed in collaboration with various organizations will also be presented.

Patterson, Richard L.↗

Electrical Devices and Circuits for Low Temperature Space Applications

The environmental temperature in many NASA missions, such as deep space probes and outer planetary exploration, is significantly below the range for which conventional commercial-off-the-shelf electronics is designed. Presently, spacecraft operating in the cold environment of such deep space missions carry a large number of radioisotope or other heating units in order to maintain the surrounding temperature of the on-board electronics at approximately 20 C. Electronic devices and circuits capable of operation at cryogenic temperatures will not only tolerate the harsh environment of deep space but also will reduce system size and weight by eliminating or reducing the heating units and their associate structures; thereby reducing system development cost as well as launch costs. In addition, power electronic circuits designed for operation at low temperatures are expected to result in more efficient systems than those at room temperature. This improvement results from better behavior in the electrical and thermal properties of some semiconductor and dielectric materials at low temperatures. An on-going research and development program on low temperature electronics at the NASA Glenn Research Center focuses on the development of efficient electrical systems and circuits capable of surviving and exploiting the advantages of low temperature environments. An overview of the program will be presented in this paper. A description of the low temperature test facilities along with selected data obtained from in-house component testing will also be discussed. On-going research activities that are being performed in collaboration with various organizations will also be presented.

Patterson, R. L.↗

Diabatic Initialization of Mesoscale Models in the Southeastern United States: Can 0 to 12h Warm Season QPF be Improved?

It is well known that numerical warm season quantitative precipitation forecasts lack significant skill for numerous reasons. Some are related to the model--it may lack physical processes required to realistically simulate convection or the numerical algorithms and dynamics employed may not be adequate. Others are related to initialization-mesoscale features play an important role in convective initialization and atmospheric observation systems are incapable of properly depicting the three-dimensional stability structure at the mesoscale. The purpose of this study is to determine if a mesoscale model initialized with a diabatic initialization scheme can improve short-term (0 to 12h) warm season quantitative precipitation forecasts in the Southeastern United States. The Local Analysis and Prediction System (LAPS) developed at the Forecast System Laboratory is used to diabatically initialize the Pennsylvania State University/National center for Atmospheric Research (PSUNCAR) Mesoscale Model version 5 (MM5). The SPORT Center runs LAPS operationally on an hourly cycle to produce analyses on a 15 km covering the eastern 2/3 of the United States. The 20 km National Centers for Environmental Prediction (NCEP) Rapid Update Cycle analyses are used for the background fields. Standard observational data are acquired from MADIS with GOES/CRAFT Nexrad data acquired from in-house feeds. The MM5 is configured on a 140 x 140 12 km grid centered on Huntsville Alabama. Preliminary results indicate that MM5 runs initialized with LAPS produce improved 6 and 12h QPF threat scores compared with those initialized with the NCEP RUC.

Lapenta, William M.↗

Connecting Black Hole States and Accertion Flow Geometry

Under this program, INTEGRAL made four observations of the Galactic black hole X-ray binary GRO 51655-40 in outburst. Our team made a number of supporting observations simultaneously in the radio, optical, and X-ray bands. The data have been processed by INTEGRAL and efforts to make a preliminary reduction and analysis of the data are underway. As the data have only been in house for a month at the time of writing, there are no significant results to report at this time, apart from the fact that the source appears to have been detected clearly even up to an energy of 200 keV.

Teegarden, Bonnard↗