Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data cubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

SU-G-JeP1-04: Characterization of a High-Definition Optical Patient Surface Tracking System Across Five Installations

Purpose: To assess the performance of Varian’s real-time, Optical Surface Monitoring System (OSMS) by measuring relative regular and irregular surface detection accuracy in 6 degrees of motion (6DoM), across multiple installations. Methods: Varian’s Intracranial SRS Package includes OSMS, which utilizes 3 HD camera/projector pods to map a patient surface, track intra-fraction motion, and gate the treatment beam if motion exceeds a threshold. To evaluate motion-detection accuracy of OSMS, we recorded shifts of a cube-shaped phantom on a single Varian TrueBeam linear accelerator as known displacements were performed incrementally across 6DoM. A subset of these measurements was repeated on identical OSMS installations. Phantom motion was driven using the TrueBeam treatment couch, and incremented across ±2cm in steps of 0.1mm, 1mm, and 1cm in the cardinal planes, and across ±40° in steps of 0.1°, 1°, and 5° in the rotational (couch kick) direction. Pitch and Roll were evaluated across ±2.5° in steps of 0.1° and 1°. We then repeated this procedure with a frameless SRS setup with a head phantom in a QFix Encompass mask. Results: Preliminary data show OSMS is capable of detecting regular-surfaced phantom displacement within 0.03±0.04mm in the cardinal planes, and within 0.01±0.03° rotation across all planes for multiple installations. In a frameless SRS setup, OSMS is accurate to within 0.10±0.07mm and 0.04±0.07° across 6DoM. Additionally, a reproducible “thermal drift” was observed during the first 15min of monitoring each day, and characterized by recording displacement of a stationary phantom each minute for 25min. Drift settled after 15min to an average delta of 0.26±0.03mm and 0.38±0.03mm from the initial capture in the Y and Z directions, respectively. Conclusion: For both regular surfaces and clinical SRS situations, OSMS exceeds quoted detection accuracy. To reduce error, a warm-up period should be employed to allow camera/projector pod thermal stabilization.

60 APPLIED LIFE SCIENCES↗

IceCube- A New Detector for Neutrino Astronomy and Particle Astrophysics

IceCube, currently under construction at the South Pole, will be a gigaton detector for high-energy neutrinos and muons. Half of the 5000 optical modules that make up IceCube are now installed in the ice and taking data. The main goal is to find high-energy neutrinos from distant astrophysical sources such as active galactic nuclei and exploding massive stars. I will describe how the detector works, show some current results and discuss status and future plans for the project.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-286: Dose Verification of Spot-Scanning Proton Beam Using GafChromic EBT3 Film

Purpose: Dose verification of spot-scanning proton pencil beam is performed via planar dose measurements at several depths using an ionization-chamber array, requiring repeat irradiations of each field for each depth. Here we investigate film dosimetry which has two advantages: higher resolution and efficiency from one-shot irradiation for multiple depths. Methods: Film calibration was performed using an EBT3 film at 20-cm depth of Plastic Water (CIRS, Norfolk, VA) exposed by a 10-level step wedge on a Proteus Plus proton system (IBA, Belgium). The calibration doses ranged from 25–250 cGy(RBE) for proton energies of 170–200 MeV. A uniform 1000 cm{sup 3} dose cube and a clinical prostate combined with seminal-vesicle and pelvic-nodes plan were used for this study. All treatment plans were generated in the RayStation (RaySearch Lab, Sweden). The planar doses at different depths for both cases were measured with film using triple-channel dosimetry and the MatriXX PT (IBA Dosimetry, Germany). The Gamma passing rates, dose-difference maps, and profiles of 2D planar doses measured with EBT3 film and MatriXX, versus treatment planning system (TPS) calculations were analyzed and compared using the FilmQA Pro (Ashland Inc., Bridgewater, NJ). Results: The EBT3 film measurement results matched well with the TPS calculation data with an average passing rate >95% for 2%/2mm and are comparable with the MatriXX measurements (0.7%, 1.8%, 3.8% mean differences corresponding to 3%/3mm, 3%/2mm, 2%/2mm, respectively). Overall passing rates for EBT3 films appear higher than those with MatriXX detectors. Conclusion: The energy dependence of the film response could be minimized by calibration using proton beam with mixed energies. The greater efficiency of the dose verification using GafChromic EBT3 results in a potential cost trade-off between room capacity and film cost. EBT3 film may offer distinct advantages in highly intensity-modulated fields due to its higher resolution compared to 2D ionization-chamber array detectors. One of the authors has a research grant from Ashland Inc., the manufacturer of GafChromic film.

60 APPLIED LIFE SCIENCES↗

Estimation of elastic properties of an additively manufactured lattice using resonant ultrasound spectroscopy

Development of improved approaches in the characterization of additively manufactured structures continues to be a topic of interest for the advanced manufacturing community. This article will investigate an approach using resonant ultrasound spectroscopy (RUS) to determine the effective elastic constants of an orthotropic lattice structure. The evaluation is performed on a cube shaped 316 L stainless steel test specimen, constructed using selective laser melting techniques. The approach uses RUS techniques in conjunction with the assumption that in the frequency regime of interest, the wavelength of the diagnostic ultrasound is greater than the discrete structural features of the unit cell of the lattice; thus, the AM structure can be treated as an anisotropic continuum with effective material properties and symmetry inherited from the unit cell. The RUS analysis estimates the nine elastic coefficients associated with orthotropic sample symmetry, which, in turn, are used to determine the elastic moduli and Poisson ratios. Current results show good agreement between experiments and modeled data. Comparisons to published results are also in good agreement, indicating the potential applicability of this characterization technique for estimating the linear elastic properties of innovative additive manufactured metal lattice structures.

36 MATERIALS SCIENCE↗

Report on partially complete post-irradiation-examination of the INL samples

Ferritic-martensitic steels (NF616 and T91), and austenitic stainless steel 800H and its Grain Boundary Engineering (GBE)-treated version 800H-TMP (ThermoMechanical Processing) were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) and their microstructures and mechanical properties were characterized. Ferritic-martensitic steels were irradiated up to 8.16 dpa in the irradiation temperatures ranging from 241 °C to 447.5 °C. Selected 800H and 800H-TMP samples were also irradiated up to 9.12 dpa at 359°C to 431°C. Vickers hardness measurement, fractography, and microstructural characterization were performed on the selected samples in the LAMDA lab. Radiation-induced hardening of NF616 and T91 was observed in the hardness measurements which show ~37% to ~65% increases, depending on irradiation dose and irradiation temperature. Within the irradiation conditions studied in this work, samples with a higher dose had a higher hardness. All the tested alloy 800H and 800H-TMP in this work showed irradiation-hardening by ~96±7% to ~152±10%. Alloy 800HTMP tended to have slightly smaller irradiation-hardening than alloy 800H. The fractography of NF616 samples D2 (2.96 dpa at 291.5°C), D4 (5.91 dpa at 359°C), and D6 (8.16 dpa at 431°C) indicated loss of ductility with negligible necking for the sample D2, yet obvious ductile failure for samples D4 and D6. Fractography of alloy 800H samples N4 (7.27 dpa at 359°C), N5 (3.9 dpa at 451.5°C), and N6 (9.01 dpa at 431°C), and alloy 800H-TMP samples P4 (7.36 dpa at 359°C), P5 (3.95 dpa at 451.5°C), and P6 (9.12 dpa at 431°C) indicated that all samples failed in a ductile mode, with obvious necking. Dimples were observed where large Ti-containing particles were observed for the samples. TEM characterization was performed on alloy 800H (N4, N5, N6) and 800H-TMP (P4, P5 and P6). Accumulation of M23C6 precipitates at grain boundaries was observed in all samples, and the presence of Ti(C,N) precipitates at grain boundaries and in the matrix was observed in alloy 800H-TMP. M23C6 precipitates were found to have the cube-on-cube orientation relationship with the matrix. In addition, nanoscale Si-rich clusters were observed in the matrix of all samples. Atom probe tomography was conducted on the same samples, and their results are being analyzed to be integrated with the TEM results for a confident description of the clustering behavior. Due to the low irradiation temperature (up to 451.5°C), dislocation loops formed in all samples, with the density and the average size of dislocation loops in the order of 1022 – 1023 m-3 and 11.7 – 15.9 nm, respectively. The loop densities in alloy 800H were higher than that in alloy 800H-TMP under the same irradiation conditions. Further systematic data analyses, together with some complementary experiments, will be pursued for these samples to foster peer-reviewed journal article publications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A numerical method for deriving shape functions of nanoparticles for pair distribution function refinements

We report that in the structural refinement of nanoparticles, discrete atomistic modeling can be used for small nanocrystals (< 15 nm), but becomes computationally unfeasible at larger sizes, where instead unit-cell-based small-box modeling is usually employed. However, the effect of the nanocrystal's shape is often ignored or accounted for with a spherical model regardless of the actual shape due to the complexities of solving and implementing accurate shape effects. Recent advancements have provided a way to determine the shape function directly from a pair distribution function calculated from a discrete atomistic model of any given shape, including both regular polyhedra (e.g. cubes, spheres, octahedra) and anisotropic shapes (e.g. rods, discs, ellipsoids) [Olds et al. (2015). J. Appl. Cryst. 48, 1651–1659], although this approach is still limited to small size regimes due to computational demands. In order to accurately account for the effects of nanoparticle size and shape in small-box refinements, a numerical or analytical description is needed. This article presents a methodology to derive numerical approximations of nanoparticle shape functions by fitting to a training set of known shape functions; the numerical approximations can then be employed on larger sizes yielding a more accurate and physically meaningful refined nanoparticle size. Lastly, the method is demonstrated on a series of simulated and real data sets, and a table of pre-calculated shape function expressions for a selection of common shapes is provided.

36 MATERIALS SCIENCE↗

Report on High Energy Arcing Fault Experiments: Experimental Results from Open Box Enclosures

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena. The experiments focus on providing data to better characterize the arc to improve the prediction of arc energy emitted during a HEAF event. An open box experiment allow for direct observation of the arc, which allows diagnostic instrumentation to record the phenomenological data needed for better characterization of the arc energy source term. The data collected supports characterization of the arc and arc jet, enclosure breach, material loss, and electrical properties. These results will be used to better characterizing the hazard for improvements in fire probabilistic risk assessment (PRA) realism. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA Labs. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 22, 2020 and September 18, 2020 on near-identical 51 cm (20 in) cube metal boxes suspended from a Unistrut support structure. The three-phase arcing fault was initiated at the ends of the conductors oriented vertically and located at the center of the box. Either aluminum or copper conductors were used for the conductors. The low-voltage experiments used 1 000 volts AC, while the medium-voltage experiments used 6 900 volts AC consistent with other recently completed experiments. Durations of the experiment ranged from 1 s to 5 s with fault currents ranging from 1 kA to 30 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. The experiments were documented with normal and high-speed videography, infrared imaging and photography.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Explosive Yield Estimation Using Regional Seismic Moment Tensors

Here, we use the Pasyanos and Chiang (2022) data set to calculate the seismic moment M 0 for each explosion and use the measured explosive yield W to validate the W~M 0 relationship in Denny and Johnson (1991; hereafter, DJ91). The M 0 is corrected by transforming to a potency tensor and applying more appropriate near-source geophysical parameter values in the moment estimate. The mean residual between observed and predicted yield is near zero; however, the standard deviation of the residuals results in an F-value (a 95% confidence factor) of about 5. We re-estimate the coefficients in the DJ91 model and find similar values and only a slight improvement in the F-value. Next, we embark on a similar model selection process as DJ91, allowing for non-cube-root yield scaling and other plausible near-source elastic moduli. As was found by DJ91, the yield dependence is not significantly different from unity, and a cube root assumption is valid. Therefore, we yield scale the seismic moment and test the significance of all plausible explanatory variables. Isotropic moment performs better in the response variable than total moment. The preference for isotropic moment could be due to its relationship to volume change, which would be more directly affected by explosive yield. Surprisingly, we find that the overburden pressure, which is a function of depth, is not a significant parameter in the model. We hypothesize that this is due to the competing depth effects on source asymmetry and the incorporation of depth in the Green’s functions used to calculate the seismic moment tensors. Importantly, this emphasizes that only seismic moment tensor-derived moments should be used in these models. After removing insignificant model parameters, we are left with a simple model to predict explosive yield $\widehat{W}$ in kt from isotropic moment M I in N·m, $\widehat{W}$=κ –1.4132 10 0.035626GP M I , in which κ and GP are the near-source bulk modulus and gas porosity in Pa and %, respectively. The F-value for this model is approximately 3.

58 GEOSCIENCES↗

Information Guided Exploration of Scalar Values and Isocontours in Ensemble Datasets

Uncertainty of scalar values in an ensemble dataset is often represented by the collection of their corresponding isocontours. Various techniques such as contour-boxplot, contour variability plot, glyphs and probabilistic marching-cubes have been proposed to analyze and visualize ensemble isocontours. All these techniques assume that a scalar value of interest is already known to the user. Not much work has been done in guiding users to select the scalar values for such uncertainty analysis. Moreover, analyzing and visualizing a large collection of ensemble isocontours for a selected scalar value has its own challenges. Interpreting the visualizations of such large collections of isocontours is also a difficult task. In this work, we propose a new information-theoretic approach towards addressing these issues. Using specific information measures that estimate the predictability and surprise of specific scalar values, we evaluate the overall uncertainty associated with all the scalar values in an ensemble system. This helps the scientist to understand the effects of uncertainty on different data features. To understand in finer details the contribution of individual members towards the uncertainty of the ensemble isocontours of a selected scalar value, we propose a conditional entropy based algorithm to quantify the individual contributions. This can help simplify analysis and visualization for systems with more members by identifying the members contributing the most towards overall uncertainty. We demonstrate the efficacy of our method by applying it on real-world datasets from material sciences, weather forecasting and ocean simulation experiments.

59 BASIC BIOLOGICAL SCIENCES↗

Solvothermal Synthesis of [Cr 7 S 8 (en) 8 Cl 2 ]Cl 3 ⋅ 2H 2 O with Magnetically Frustrated [Cr 7 S 8 ] 5+ Double‐Cubes**

Abstract A novel transition metal chalcohalide [Cr 7 S 8 (en) 8 Cl 2 ]Cl 3 ⋅ 2H 2 O, with [Cr 7 S 8 ] 5+ dicubane cationic clusters, has been synthesized by a low temperature solvothermal method, using dimethyl sulfoxide (DMSO) and ethylenediamine ( en ) solvents. Ethylenediamine ligand exhibits bi‐ and monodentate coordination modes; in the latter case ethylenediamine coordinates to Cr atoms of adjacent clusters, giving rise to a 2D polymeric structure. Although magnetic susceptibility shows no magnetic ordering down to 1.8 K, a highly negative Weiss constant, θ =−224(2) K, obtained from Curie‐Weiss fit of inverse susceptibility, suggests strong antiferromagnetic (AFM) interactions between S =3/2 Cr(III) centers. Due to the complexity of the system with (2 S +1) 7 =16384 microstates from seven Cr 3+ centers, a simplified model with only two exchange constants was used for simulations. Density‐functional theory (DFT) calculations yielded the two exchange constants to be J 1 =−21.4 cm −1 and J 2 =−30.2 cm −1 , confirming competing AFM coupling between the shared Cr 3+ center and the peripheral Cr 3+ ions of the dicubane cluster. The best simulation of the experimental data was obtained with J 1 =−20.0 cm −1 and J 2 =−21.0 cm −1 , in agreement with the slightly stronger AFM exchange within the triangles of the peripheral Cr 3+ ions as compared to the AFM exchange between the central and peripheral Cr 3+ ions. This compound is proposed as a synthon towards magnetically frustrated systems assembled by linking dicubane transition metal‐chalcogenide clusters into polymeric networks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distinct Recrystallization Pathways in a Cold-Rolled Al-2%Mg Alloy Evidenced by In-Situ Neutron Diffraction

The time-of-flight neutron diffraction data collected in-situ on Oak Ridge National Laboratory’s (ORNL, Oak Ridge, TN, USA) VULCAN and Los Alamos National Laboratory’s (LANL, Los Alamos, NM, USA) High-Pressure-Preferred-Orientation (HIPPO) diffractometers have been analyzed complementarily to show the texture evolution during annealing of a cold-rolled Al-2%Mg alloy. The texture analysis aimed to identify the components present in the initial rolling (or deformation) texture and in the thermally-activated recrystallization texture, respectively. Using a quasi-Monte-Carlo (QMC) approach, a new method has been developed to simulate the weighted texture components, and to obtain inverse pole figures for both rolling and normal directions. As such, distinct recrystallization pathways during annealing in isochronal conditions, can be revealed in terms of the evolution of the texture components and their respective volume fractions. Moreover, the recrystallization kinetics associated with the cube and random texture components are analyzed quantitatively using a similar approach developed for differential scanning calorimetry (DSC).

36 MATERIALS SCIENCE↗

Nanoalloy catalysts inside fuel cells: An atomic-level perspective on the functionality by combined in operando x-ray spectroscopy and total scattering

We introduce an experimental approach for structural characterization of catalysts for fuel cells combining synchrotron x-ray spectroscopy and total scattering. The approach allows probing catalysts inside operating fuel cells with atomic-level precision (~ 0.02 Å) and element specificity (~ 2–3 at%) in both time (~ 1 min) and space (~ μm) resolved manner. The approach is demonstrated on exemplary Pd-Sn and Pt-Ni-Cu nanoalloy catalysts for the oxygen reduction reaction (ORR) deposited on the cathode of an operating proton exchange membrane fuel cell. In operando x-ray data show that under operating conditions, the catalyst particles can undergo specific structural changes, ranging from sub-Å atomic fluctuations and sharp nanophase transitions to a gradual strain relaxation and growth, which inflict significant losses in their ORR activity. Though triggered electrochemically, the changes are not driven solely by differences in the reduction potential and surface energy of the metallic species constituting the nanoalloys but also by the formation energy of competing nanophases, mismatch between the size of individual atomic species and their ability to interdiffuse fast in search of energetically favorable configurations. Given their complexity, the changes are difficult to predict and so the resulting ORR losses remain difficult to limit. We show that in operando knowledge of the structural evolution of nanoalloy catalysts helps create strategies for improving their activity and stability. In particular, we show that shaping Pd-Sn nanoalloys rich in Pd as cubes reduces the interdiffusion of atoms at their surface and so makes them better catalysts for ORR in fuel cells in comparison to other Pd-Sn nanoalloys. In addition, we demonstrate that the approach introduced here can provide knowledge of other major factors affecting the performance of fuel cells such as operating temperature and the overall catalyst utilization, in particular the evolution of elemental and mass distribution of catalyst particles over the cells’ cathode. Last but not least, we discuss how in operando x-ray spectroscopy and total x-ray scattering can bridge the knowledge gap between the widely used in situ SAXS, EXAFS and monocrystal surface XRD techniques for structural characterization of nanoalloy catalysts explored for energy related applications.

25 ENERGY STORAGE↗

Small-scale properties from exascale computations of turbulence on a $\mathbf{32\,768^3}$ periodic cube

To study the physics of small-scale properties of homogeneous isotropic turbulence at increasingly high Reynolds numbers, direct numerical simulation results have been obtained for forced isotropic turbulence at Taylor-scale Reynolds number R λ = 2500 on a 32 768 3 three-dimensional periodic domain using a GPU pseudo-spectral code on a 1.1 exaflop GPU supercomputer (Frontier). These simulations employ the multi-resolution independent simulation (MRIS) technique (Yeung & Ravikumar 2020, Phys. Rev. Fluids, vol. 5, 110517) where ensemble averaging is performed over multiple short segments initiated from velocity fields at modest resolution, and subsequently taken to higher resolution in both space and time. Reynolds numbers are increased by reducing the viscosity with the large-scale forcing parameters unchanged. Although MRIS segments at the highest resolution for each Reynolds number last for only a few Kolmogorov time scales, small-scale physics in the dissipation range is well captured – for instance, in the probability density functions and higher moments of the dissipation rate and enstrophy density, which appear to show monotonic trends persisting well beyond the Reynolds number range in prior works in the literature. Attainment of range of length and time scales consistent with classical scaling also reinforces the potential utility of the present high-resolution data for studies of short-time-scale turbulence physics at high Reynolds numbers where full-length simulations spanning many large-eddy time scales are still not accessible. A single snapshot of the 32 768 3 data is publicly available for further analyses via the Johns Hopkins Turbulence Database.

intermittency↗

Dose and detectability for a cone-beam C-arm CT system revisited

Purpose: The authors had previously published measurements of the detectability of disk-shaped contrast objects in images obtained from a C-arm CT system. A simple approach based on Rose's criterion was used to scale the date, assuming the threshold for the smallest diameter detected should be inversely proportional to (dose){sup 1/2}. A more detailed analysis based on recent theoretical modeling of C-arm CT images is presented in this work. Methods: The signal and noise propagations in a C-arm based CT system have been formulated by other authors using cascaded systems analysis. They established a relationship between detectability and the noise equivalent quanta. Based on this model, the authors obtained a relation between x-ray dose and the diameter of the smallest disks detected. A closed form solution was established by assuming no rebinning and no resampling of data, with low additive noise and using a ramp filter. For the case when no such assumptions were made, a numerically calculated solution using previously reported imaging and reconstruction parameters was obtained. The detection probabilities for a range of dose and kVp values had been measured previously. These probabilities were normalized to a single dose of 56.6 mGy using the Rose-criteria-based relation to obtain a universal curve. Normalizations based on the new numerically calculated relationship were compared to the measured results. Results: The theoretical and numerical calculations have similar results and predict the detected diameter size to be inversely proportional to (dose){sup 1/3} and (dose){sup 1/2.8}, respectively. The normalized experimental curves and the associated universal plot using the new relation were not significantly different from those obtained using the Rose-criterion-based normalization. Conclusions: From numerical simulations, the authors found that the diameter of detected disks depends inversely on the cube root of the dose. For observer studies for disks larger than 4 mm, the cube root as well as square root relations appear to give similar results when used for normalization.

36 MATERIALS SCIENCE↗

GRiP - A flexible approach for calculating risk as a function of consequence, vulnerability, and threat.

Get a GRiP (Gravitational Risk Procedure) on risk by using an approach inspired by the physics of gravitational forces between body masses! In April 2010, U.S. Department of Homeland Security Special Events staff (Protective Security Advisors [PSAs]) expressed concern about how to calculate risk given measures of consequence, vulnerability, and threat. The PSAs believed that it is not 'right' to assign zero risk, as a multiplicative formula would imply, to cases in which the threat is reported to be extremely small, and perhaps could even be assigned a value of zero, but for which consequences and vulnerability are potentially high. They needed a different way to aggregate the components into an overall measure of risk. To address these concerns, GRiP was proposed and developed. The inspiration for GRiP is Sir Isaac Newton's Universal Law of Gravitation: the attractive force between two bodies is directly proportional to the product of their masses and inversely proportional to the squares of the distance between them. The total force on one body is the sum of the forces from 'other bodies' that influence that body. In the case of risk, the 'other bodies' are the components of risk (R): consequence, vulnerability, and threat (which we denote as C, V, and T, respectively). GRiP treats risk as if it were a body within a cube. Each vertex (corner) of the cube represents one of the eight combinations of minimum and maximum 'values' for consequence, vulnerability, and threat. The risk at each of the vertices is a variable that can be set. Naturally, maximum risk occurs when consequence, vulnerability, and threat are at their maximum values; minimum risk occurs when they are at their minimum values. Analogous to gravitational forces among body masses, the GRiP formula for risk states that the risk at any interior point of the box depends on the squares of the distances from that point to each of the eight vertices. The risk value at an interior (movable) point will be dominated by the value of one vertex as that point moves closer and closer to that one vertex. GRiP is a visualization tool that helps analysts better understand risk and its relationship to consequence, vulnerability, and threat. Estimates of consequence, vulnerability, and threat are external to GRiP; however, the GRiP approach can be linked to models or data that provide estimates of consequence, vulnerability, and threat. For example, the Enhanced Critical Infrastructure Program/Infrastructure Survey Tool produces a vulnerability index (scaled from 0 to 100) that can be used for the vulnerability component of GRiP. We recognize that the values used for risk components can be point estimates and that, in fact, there is uncertainty regarding the exact values of C, V, and T. When we use T = t{sub o} (where t{sub o} is a value of threat in its range), we mean that threat is believed to be in an interval around t{sub o}. Hence, a value of t{sub o} = 0 indicates a 'best estimate' that the threat level is equal to zero, but still allows that it is not impossible for the threat to occur. When t{sub o} = 0 but is potentially small and not exactly zero, there will be little impact on the overall risk value as long as the C and V components are not large. However, when C and/or V have large values, there can be large differences in risk given t{sub o} = 0, and t{sub o} = epsilon (where epsilon is small but greater than a value of zero). We believe this scenario explains the PSA's intuition that risk is not equal to zero when t{sub o} = 0 and C and/or V have large values. (They may also be thinking that if C has an extremely large value, it is unlikely that T is equal to 0; in the terrorist context, T would likely be dependent on C when C is extremely large.) The PSAs are implicitly recognizing the potential that t{sub o} = epsilon. One way to take this possible scenario into account is to replace point estimates for risk with interval values that reflect the uncertainty in the risk components. In fact, one could argue that T never equals zero for a man-made hazard. This paper describes the thought process that led to the GRiP approach and the mathematical formula for GRiP and presents a few examples that will provide insights about how to use GRiP and interpret its results.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Different site occupancies in substitution variants of Mo{sub 3}Sb{sub 7}

A series of samples with the initial formula Mo{sub 3–x}Fe{sub x}Sb{sub 7} and Mo{sub 3–x}Ni{sub x}Sb{sub 7} have been prepared by solid state reaction at 873 K, starting from the elements in the stoichiometric ratios. The materials were compressed via hot-pressing, and their thermoelectric properties determined. Single crystal data show that Ni atoms in part occupy the cubic voids of the Mo{sub 3}Sb{sub 7} structure, as well as replace some Mo atoms, in contrast to the Fe analogues, where we found no evidence for Fe in the cubic voids. Supported by electronic structure calculations, replacing Mo with Fe or Ni increases the valence-electron count, thus decreases the numbers of p-type carriers of Mo{sub 3}Sb{sub 7}. On the other hand, filling the holes with Ni atoms appears to have no such effect. As a consequence, the Ni containing samples exhibit higher electrical conductivity than the Fe analogues, and ultimately lower thermoelectric figure-of-merit, as the p-type carrier concentration remains too high. - Graphical abstract: Trying to substitute Ni atoms for Mo in Mo{sub 3}Sb{sub 7} resulted in partial filling of the cubic voids, in contrast to Mo{sub 3–x}Fe{sub x}Sb{sub 7}. Since the Ni atoms in the Sb{sub 8} cubes do not act as electron donors, the Ni-containing materials exhibit very high carrier concentration, and thus high electric conductivity and low Seebeck coefficient. - Highlights: • Various substitution variants of Mo{sub 3}Sb{sub 7} with Fe and Ni were characterized. • While the Fe atoms replace the Mo atoms, the Ni atoms also fill the cubic voids. • Higher Fe/Ni amount on the Mo sites causes a decrease of the charge carriers. • The Ni atoms on the cubic sites do not decrease the charge carriers. • The lower the carrier concentration, the better the thermoelectric properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Embedded symmetric positive semi-definite machine-learned elements for reduced-order modeling in finite-element simulations with application to threaded fasteners

Here, we present a machine-learning strategy for finite element analysis of solid mechanics wherein we replace complex portions of a computational domain with a data-driven surrogate. In the proposed strategy, we decompose a computational domain into an “outer” coarse-scale domain that we resolve using a finite element method (FEM) and an “inner” fine-scale domain. We then develop a machine-learned (ML) model for the impact of the inner domain on the outer domain. In essence, for solid mechanics, our machine-learned surrogate performs static condensation of the inner domain degrees of freedom. This is achieved by learning the map from displacements on the inner-outer domain interface boundary to forces contributed by the inner domain to the outer domain on the same interface boundary. We consider two such mappings, one that directly maps from displacements to forces without constraints, and one that maps from displacements to forces by virtue of learning a symmetric positive semi-definite (SPSD) stiffness matrix. We demonstrate, in a simplified setting, that learning an SPSD stiffness matrix results in a coarse-scale problem that is well-posed with a unique solution. We present numerical experiments on several exemplars, ranging from finite deformations of a cube to finite deformations with contact of a fastener-bushing geometry. We demonstrate that enforcing an SPSD stiffness matrix drastically improves the robustness and accuracy of FEM–ML coupled simulations, and that the resulting methods can accurately characterize out-of-sample loading configurations with significant speedups over the standard FEM simulations.

97 MATHEMATICS AND COMPUTING↗

Motion as a perturbation: Measurement-guided dose estimates to moving patient voxels during modulated arc deliveries

Purpose: To present a framework for measurement-guided VMAT dose reconstruction to moving patient voxels from a known motion kernel and the static phantom data, and to validate this perturbation-based approach with the proof-of-principle experiments. Methods: As described previously, the VMAT 3D dose to a static patient can be estimated by applying a phantom measurement-guided perturbation to the treatment planning system (TPS)-calculated dose grid. The fraction dose to any voxel in the presence of motion, assuming the motion kernel is known, can be derived in a similar fashion by applying a measurement-guided motion perturbation. The dose to the diodes in a helical phantom is recorded at 50 ms intervals and is transformed into a series of time-resolved high-density volumetric dose grids. A moving voxel is propagated through this 4D dose space and the fraction dose to that voxel in the phantom is accumulated. The ratio of this motion-perturbed, reconstructed dose to the TPS dose in the phantom serves as a perturbation factor, applied to the TPS fraction dose to the similarly situated voxel in the patient. This approach was validated by the ion chamber and film measurements on four phantoms of different shape and structure: homogeneous and inhomogeneous cylinders, a homogeneous cube, and an anthropomorphic thoracic phantom. A 2D motion stage was used to simulate the motion. The stage position was synchronized with the beam start time with the respiratory gating simulator. The motion patterns were designed such that the motion speed was in the upper range of the expected tumor motion (1-1.4 cm/s) and the range exceeded the normally observed limits (up to 5.7 cm). The conformal arc plans for X or Y motion (in the IEC 61217 coordinate system) consisted of manually created narrow (3 cm) rectangular strips moving in-phase (tracking) or phase-shifted by 90 Degree-Sign (crossing) with respect to the phantom motion. The XY motion was tested with the computer-derived VMAT MLC sequences. For all phantoms and plans, time-resolved (10 Hz) ion chamber dose was collected. In addition, coronal (XY) films were exposed in the cube phantom to a VMAT beam with two different starting phases, and compared to the reconstructed motion-perturbed dose planes. Results: For the X or Y motions with the moving strip and geometrical phantoms, the maximum difference between perturbation-reconstructed and ion chamber doses did not exceed 1.9%, and the average for any motion pattern/starting phase did not exceed 1.3%. For the VMAT plans on the cubic and thoracic phantoms, one point exhibited a 3.5% error, while the remaining five were all within 1.1%. Across all the measurements (N = 22), the average disagreement was 0.5 {+-} 1.3% (1 SD). The films exhibited {gamma}(3%/3 mm) passing rates {>=}90%. Conclusions: The dose to an arbitrary moving voxel in a patient can be estimated with acceptable accuracy for a VMAT delivery, by performing a single QA measurement with a cylindrical phantom and applying two consecutive perturbations to the TPS-calculated patient dose. The first one accounts for the differences between the planned and delivered static doses, while the second one corrects for the motion.

60 APPLIED LIFE SCIENCES↗