Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cyber detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Flexible visualization of a 3rd party Intrusion Prevention (Security) tool: A use case with the ELK stack

A difficult aspect of cyber security is the ability to achieve automated real time intrusion prevention across various sets of systems. To this extent, several companies are offering comprehensive solutions that leverage an "accuracy of scale" and moving much of the intelligence and detection on the Cloud, relying on an ever-growing set of data and analytics to increase decision accuracy. Often, they provide tools to visualize the decision workflows in attack prevention (as well as tune the algorithm) but those solutions are not always practical as companies see the problem as "global" that is, from a unified Cyber-security standpoint. However, a key to a successful Cyber-security program is transparency and trust: from an experimental team viewpoint, this specifically means having the ability to immediately see what and from where, who has been blocked and being able to inform the community in case of a revoked access without the need for filing a "ticket" (that may eventually be answered) – in other words, rapid response to their user-base is essential but solutions targeting "sub-groups" in an organization are not often available. We have come up with a versatile solution leveraging the ELK stack (Elasticsearch, Logstash, & Kibana) and an IPS (Intrusion Prevention System) based WAF (Web Application Firewall) from Signal Sciences. Signal Science allows the streaming of detailed logs in a Logstash format suitable for custom solutions for visualization. By combining these two tools, we have strengthened our security posture and enabled individual experiments to monitor their own traffic. Specifically, the IPS WAF provides unique data such as country of origin, protocol, response code, source IP, and paths accessed. In this contribution, we will show how we engineered a visualization solution so experiment groups could access a dashboard with predefined graphs but also, where they can create individual customizable dashboards used to display blocked traffic and troubleshoot latency issues. We will discuss the details and procedures for developing and configuring these tools and how it benefits cyber security postures across our scientific based environment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Graph-Net with Node Embeddings to Detect False Data Injection Attacks in Photovoltaic Systems

Distributed energy resources (DER) contribute to the operational stability of the larger power grid both at utility-scale as well as commercial and residential scales in aggregated forms. These DER in-turn are susceptible to increasing cyber threats. An adversary can plug into the same local network that a field photovoltaic (PV) system uses to interconnect its data loggers and inverters and manipulate certain measurements collected from the network or trick existing irradiance and inverter readings through false data injection attacks (FDIA). Control routines that rely on these measurements can propagate the false data, impacting critical decisions that result in a suboptimal operation or even cause intentional harm leading to inverter-tripping or unscheduled loads that need to be shed. To detect FDIA in PV systems, the paper introduces an attention-based graph neural network with node embeddings and applied it to a simple prototypical DC-coupled microgrid with PV, energy storage, and load. The algorithm shows a detection accuracy of up to 98.95%. The proposed FDIA detection technique will provide micro-grid operators with an effective method to safeguard their systems, guaranteeing the secure and reliable operation.

Parvez, Imtiaz [Utah Valley University]↗

Adaptive, self-tuning virtual sensing system for cyber-attack neutralization

An industrial asset may have a plurality of monitoring nodes, each monitoring node generating a series of monitoring node values over time representing current operation of the industrial asset. An abnormality detection computer may determine that an abnormal monitoring node is currently being attacked or experiencing a fault. An autonomous, resilient estimator may continuously execute an adaptive learning process to create or update virtual sensor models for that monitoring node. Responsive to an indication that a monitoring node is currently being attacked or experiencing a fault, a level of neutralization may be automatically determined. The autonomous, resilient estimator may then be dynamically reconfigured to estimate a series of virtual node values based on information from normal monitoring nodes, appropriate virtual sensor models, and the determined level of neutralization. The series of monitoring node values from the abnormal monitoring node or nodes may then be replaced with the virtual node values.

Abbaszadeh, Masoud↗

OT Operational Anomaly Detection (OAD) T&D + DER

The growth of utility-scale renewable energy resources, distributed energy resources (DER), and transportation electrification has increased uncertainty and cybersecurity risks in power grids. The Purdue Enterprise Reference Architecture model which is widely adopted by the utility industry is now insufficient to protect the power grid against cyber-attacks. There is a need to identify what cybersecurity model is effective on Energy Management System (EMS), Advanced Distribution Management System (ADMS), and DER Management System (DERMS) to address the fundamental cybersecurity challenges in the age of increasing renewable energy and DER share as well as consumer participation in the electric energy industry. The next generation of cybersecurity model for OT network should be able to detect inside attackers, mitigate the cybersecurity risks arising from the new grid participants including DER aggregators, electric vehicle owners, and behind-the-meter consumers outside the utility company, and develop the strategy to trust consumer measurement data. This panel will discuss the challenges and pathways for the development of an ensemble cybersecurity model based on predictive state estimation to detect cybersecurity anomalies in OT network including EMS, ADMS, and DERMS.

cybersecurity↗

Anomaly Detection and Mitigation for Dynamic Frequency Regulation in Hydropower-Battery Systems

Hydropower operators and energy storage providers are increasingly interested in participating in frequency regulation services, driven by the incentives offered by independent system operators, such as the PJM Interconnection. This transition, however, unfolds against the backdrop of a modernizing and rapidly digitizing power grid, exposing the integrated legacy infrastructure to a multitude of cybersecurity threats. This work presents an approach for developing an anomaly detection and mitigation system to address cybersecurity challenges during the participation of a hydropower-integrated battery energy storage system (BESS) in a frequency regulation market. The applied anomaly detector utilizes machine learning algorithms to provide detailed classification of cyber-physical events. Later, the applied mitigation system triggers predefined corrective actions to minimize the impact of data integrity attacks on the regulation market and system stability. We evaluated the proposed approach on a hydropower-integrated BESS topology, specifically analyzing the slow regulation signal (Reg A) coming from the PJM market. Our simulation results demonstrate that the proposed approach performs well in detecting data integrity attacks within the allocated time frame and also minimizes the system's transient instability during the participation of hydropower and BESS in the regulation market.

battery energy storage system↗

Demystifying Cyberattacks: Potential for Securing Energy Systems With Explainable AI : Preprint

Modernization of energy systems has led to in- creased interactions among multiple critical infrastructures and diverse stakeholders making the challenge of operational decision making more complex and at times beyond cognitive capabilities of human operators. The state-of-the-art machine learning and deep learning approaches show promise of supporting users with complex decision-making challenges, such as those occurring in our rapidly transforming cyber-physical energy systems. However, successful adoption of data-driven decision support technology for critical infrastructure will be dependent on the ability of these technologies to be trustworthy and contextually interpretable. In this paper, we investigate the feasibility of implementing XAI for interpretable detection of cyberattacks in the energy system. Leveraging a proof-of-concept simulation use case of detection of a data falsification attack on a photovoltaic system using XGBoost algorithm, we demonstrate how Local Interpretable Model-Agnostic Explanations (LIME), a flavor XAI approach, can help provide contextual and actionable interpretation of cyberattack detection.

artificial intelligence↗

Cybersecurity Attacks in Vehicular Sensors

Today's modern vehicles contain anywhere from sixty to one-hundred sensors and exhibit the characteristics of Cyber-Physical-Systems (CPS). There is a high degree of coupling, cohesiveness, and interactions among vehicle's CPS components (e.g., sensors, devices, systems, systems-of-systems) across sensing, communication, and control layers. Cyber-attacks in the sensing or communication layers can compromise the security of the control layer. This paper provides a detailed review of potential cyber threats related to the sensing layer. Notably, the focus is mainly towards two categories of sensors: vehicle dynamics sensors (e.g., Tire Pressure Monitoring Systems (TPMS), magnetic encoders, and inertial sensors) and environment sensors (e.g., Light Detection and Ranging (LiDAR), ultrasonic, camera, Radio Detection and Ranging (Radar) systems, and Global Positioning System (GPS) units). Furthermore, the paper also offers perspectives through existing countermeasures from literature and stresses the need for data-driven cybersecurity solutions.

97 MATHEMATICS AND COMPUTING↗

Review of internal cyber attacks in nuclear facilities and an artificial neural network model for implementing internal cyberforensics

Deployment of digital technologies within a modern shift in cyber defense systems is essential for protecting the energy production units. One of the important components of defense is cyberforensics: once an attack has been detected to locate its origin. In this paper, a review of well-known cyberattacks in nuclear facilities is provided, with the lessons learned leading to the development of a machine learning approach implementing identification of internal at- tacks in the facility's data networks. Our approach may be seen as one of the layers in a defense-in-depth strategy that identifies if the attack comes from inside, which may result in identifying faster the attacker's origin. The presented model exploits network packet examination to cast accurate predictions on detailing the origin of malicious network connections. The approach fuses multiple mathematical functions within an artificial neural network to provide a response in the form of 0/1, i. e., whether the attack is identified as internal or not. The utilization of a variety of test cases is developed to explore the relevance and validity of the predictive approach. The proposed implementation is examined with network data packet variance, and the results obtained exhibit a highly accurate detection rate.

Nuclear Science & Technology↗

Vulnerability Detection Methodology for a Digital Signal Processor Micro-Controller at Edge Level Distributed Energy Resource Controller

Integration of renewable energy and energy storage based Distributed Energy Resource (DER) assets to the grid has seen an upsurge over the past few decades. Traditionally, energy would be generated at a thermal or nuclear power plant and then transmitted over long distance through the transmission grid and then supply to the customers at the distribution grid. Modern renewable energy based DER assets have brought energy production at the edge of distribution grid, which has made the grid vulnerable to cyber intrusion as the power flow controllers for such DER assets are now distributed across the grid from distribution level to transmission level. This paper discusses the vulnerability posed by such power flow controllers of DER assets and demonstrates a detection methodology for unauthorized access and manipulation of system configuration for Digital Signal Processor based Microcontrollers. Experimental results proving efficacy of the methodology have been shown in paper.

Bhowmik, Pankaj↗

Autonomous reconfigurable virtual sensing system for cyber-attack neutralization

An industrial asset may be associated with a plurality of monitoring nodes, each monitoring node generating a series of monitoring node values over time representing current operation of the industrial asset. An abnormality detection computer may determine that at least one abnormal monitoring node is currently being attacked or experiencing a fault. A virtual sensing estimator may continuously execute an adaptive learning process to create or update virtual sensor models for the monitoring nodes. Responsive to an indication that a monitoring node is currently being attacked or experiencing a fault, the virtual sensing estimator may be dynamically reconfigured to estimate a series of virtual node values for the abnormal monitoring node or nodes based on information from normal monitoring nodes and appropriate virtual sensor models. The series of monitoring node values from the abnormal monitoring node or nodes may then be replaced with the virtual node values.

97 MATHEMATICS AND COMPUTING↗

Modeling Cyber Supply Chain Incidents with Multilayered Graph Motifs

As noted within the literature, supply chain includes people and organizations---manufacturers, integrators, and third-party vendors---that are involved in one or more stages of a product lifecycle. Since supply chains, by definition, include organizations and people, supply chain risk management activities must consider dependencies between an organization's business processes and third-party resources. Just as adversarial tactics can be implemented via techniques implemented via networked computer systems, so can such tactics be expressed via legal business relationships. A cyber incident may have an exponential impact downstream, for example, by leveraging a product's distribution channel (e.g. malicious updates in SolarWinds, buggy updates in CrowdStrike). Similarly, legitimate and legal business relationships also affect the attack surface exposure of systems, enabling long-term persistence and/or unknown impacts to product quality that are hard to detect. This paper catalogs several recent digital supply chain incidents and applies a multilayered network formalism to develop structural indicators (graph motifs) that reflect potentially-adversarial behavior. Finally, we compare and contrast the characteristics of adversarial tactics (e.g. Loss of Availability, Data Collection) that leverage cyber-physical dependencies to those that leverage legal organizational relationships.

97 - MATHEMATICS AND COMPUTING↗

Precursor Analysis Report: Remote Access Attack on Oldsmar Water Treatment Facility 2021

The Remote Access Attack on Oldsmar Water Treatment Facility 2021 Precursor Analysis Report leverages publicly available information about the Oldsmar cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. On 5 February 2021, an adversary gained unauthorized remote access to Bruce T. Haddock Water Treatment Plant in Oldsmar, Florida, which provides treated water to 15,000 customers. The adversary accessed the facility’s Supervisory Control and Data Acquisition (SCADA) workstation and human machine interface (HMI) to change the chemical concentration of sodium hydroxide, commonly referred to as lye and used to regulate acidity levels, from 100 parts per million (PPM) to 11,100 PPM. The chemical was raised to lethal levels that if ingested could lead to serious soft tissue damage, burns, or even death. The facility, however, had redundancies and alarms in place to alert personnel of dangerous chemical levels, and facility officials stated it would have taken 24 to 36 hours for the chemical changes to affect the water supply. Researchers and analysts identified six unique techniques utilized during the attack with a total of 23 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Four of the identified techniques used during the Oldsmar cyber attack were precursors to the triggering event. Analysis identified 21 observables associated with these precursor techniques, 20 of which were assessed to have an increased likelihood of being perceived in the minutes preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Anomaly Detection and Mitigation for Dynamic Frequency Regulation in Hydropower-Battery Systems: Preprint

Hydropower operators and energy storage providers are increasingly interested in participating in frequency regulation services, driven by the incentives offered by independent system operators, such as the Pennsylvania-New Jersey-Maryland Interconnection (PJM), in a competitive electricity market. This transition, however, unfolds against the backdrop of a modernizing and rapidly digitizing power grid, exposing the integrated legacy infrastructure and vulnerable communication networks to a multitude of cybersecurity threats. These evolving threats not only endanger grid operations but also have the potential to trigger cascading disruptions across the broader grid network and influence regulation markets. This work presents an approach for developing an anomaly detection and mitigation system to address cybersecurity challenges during the participation of a hydropower-integrated battery energy storage system (BESS) in a frequency regulation market. The applied anomaly detector utilizes machine learning algorithms to provide detailed classification of cyber-physical events and provide a comprehensive situation awareness to grid operators. Later, the applied mitigation system triggers predefined corrective actions to minimize the impact of data integrity attacks on the regulation market and system stability. We evaluated the proposed approach on a fully active BESS topology using the slow regulation signal (Reg A) coming from the PJM market. Our simulation results reveal that the proposed approach performs well in detecting data integrity attacks within the allocated time frame and also minimizes the system's instability and economic loss during the participation of hydropower and BESS in the regulation market.

battery energy storage system↗

Detection of Synchrophasor False Data Injection Attack using Feature Interactive Network

The synchrophasor data recorded by Phasor Measurement Units (PMUs) plays an increasingly critical role in the regulation and situational awareness of power systems. However, the widely installed PMUs are vulnerable to multiple malicious attacks from cyber hackers during data transmission and storage. To address this problem, a Modified Ensemble Empirical Mode Decomposition (MEEMD) is proposed first to extract the intrinsic mode functions of each Synchrophasor Data Attacks (SDA). The frequency-based adaptive screening criterion embedded in MEEMD is used to eliminate the false intrinsic mode functions. Next, a Multivariate Convolutional Neural Network (MCNN) is proposed to identify multiple SDA by utilizing the extracted intrinsic mode functions and original SDA as input vectors. A fusion block as the main structure of MCNN is also leveraged to increase the diversity of features and compress the model parameters. Integrating MEEMD and MCNN, a framework with automatic feature extraction and multi-source information fusion capability, referred to as Feature Interactive Network (FIN), is proposed to detect multiple SDA. Based on the proposed FIN framework, six types of SDA are explored for the first time using actual synchrophasor data in FNET/Grideye that was collected from different locations in the U.S. Eastern Interconnection. Finally, a large quantity of experiments with different attack strengths are used to evaluate the adaptability and classification performance of the proposed FIN.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Precursor Analysis Report: Ryuk Ransomware Attack on Universal Health Services 2020

The Ryuk Ransomware Attack on Universal Health Services (UHS) 2020 Precursor Analysis Report leverages publicly available information about the 2020 UHS cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. UHS manages over 400 hospitals and is one of the largest healthcare providers in the United States with 3.5 million patients each year. On 27 September 2020, UHS suffered a widespread ransomware attack that resulted in a denial of service to critical internet-dependent healthcare systems including workstations, phones, and data centers. Employees resorted to filing patient details with pen and paper, while other facilities had to redirect ambulances and urgent patients to other facilities for adequate care. Adversaries carried out the attack with Ryuk, a ransomware that encrypts data and generates a RyukReadMe.txt ransom note with the ransom fee to decrypt the data, varying from 15 Bitcoin (BTC) to 50 BTC, equivalent to roughly $\$$353,892 to $\$$964,617. UHS did not pay the ransom and was able to recover data through backups, but still reported an impact of $\$$67 million dollars in recovery costs. On 29 October, one month after the attack, UHS made an official statement that their systems had been restored and they were resuming normal operations. Researchers and analysts identified 18 unique techniques (used in a sequence of 19 steps) utilized during the attack with a total of 185 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Fourteen of the identified techniques used during the UHS cyber attack were precursors to the triggering event. Analysis identified 106 observables associated with these precursor techniques, 82 of which were assessed to have an increased likelihood of being perceived in the 30 days to two hours preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

SDN-Based Smart Cyber Switching (SCS) for Cyber Restoration of a Digital Substation

In recent years, critical infrastructure and power grids have increasingly been targets of cyber-attacks, causing widespread and extended blackouts. Digital substations are particularly vulnerable to such cyber incursions, jeopardizing grid stability. This paper addresses these risks by proposing a cybersecurity framework that leverages software-defined networking (SDN) to bolster the resilience of substations based on the IEC- 61850 standard. The research introduces a strategy involving smart cyber switching (SCS) for mitigation and concurrent intelligent electronic device (CIED) for restoration, ensuring ongoing operational integrity and cybersecurity within a substation. The SCS framework improves the physical network’s behavior (i.e., leveraging commercial SDN capabilities) by incorporating an adaptive port controller (APC) module for dynamic port management and an intrusion detection system (IDS) to detect and counteract malicious IEC-61850-based sampled value (SV) and generic object-oriented system event (GOOSE) messages within the substation’s communication network. The framework’s effectiveness is validated through comprehensive simulations and a hardware-in-the-loop (HIL) testbed, demonstrating its ability to sustain substation operations during cyber-attacks and significantly improve the overall resilience of the power grid.

Liu, Chen-Ching (ORCID:0000000289417958)↗

Load Margin Constrained Moving Target Defense against False Data Injection Attacks

Cyber physical security of power systems with high penetration of renewable generation has attracted attention from researchers. One critical issue is that cyber-physical attacks, disguised as uncertain renewable generation, can target conventional power system state estimation (SE). Moving target defense (MTD) is a promising defense strategy to detect stealthy false data injection (FDI) attacks against SE. However, all existing studies myopically perturb the reactance of transmission lines equipped with distributed flexible AC transmission system (D-FACTS) devices without adequately considering the system voltage stability. Exacerbated by the renewable generation uncertainty, existing MTD may cause voltage instability when the power grid is under stress. To address this issue, we propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow. We utilize the sensitivity matrix of power injection to line impedance, on which an optimization problem for maximizing load margin is formulated. This framework is validated on the IEEE 14-bus system and the IEEE 118-bus system, in which net load redistribution attacks are launched by sophisticated attackers. Steady-state simulations and dynamic simulations on PSS/E show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. The impact of the proposed method on attack detection effectiveness is also revealed.

Zhang, Hang↗