Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controlled humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A preliminary investigation of the Environmental Control and Life Support Subsystem (EC/LSS) for the space construction base manufacturing modules

The preliminary data of the environmental control and life support subsystem for a space construction base manufacturing module was reported. A space processing module, which is capable of performing production biological experiments, was chosen as a baseline configuration. The primary assemblies and components considered for use were humidity and temperature control, ventilation fan, cabin fan, water separator, condensate storage, overboard dumping, distribution system, contaminant monitoring, cabin sensors, and fire and smoke detection.

Wells, H. B.↗

Diffusion-to-Imbibition Transition in Water Sorption in Nanoporous Media: Theoretical Studies

The ability to predict multiphase fluid transport in nanoporous rocks such as shales is critical for many geoscience applications, for example unconventional hydrocarbon production, geologic carbon sequestration, and nuclear waste disposal. When the pore sizes approach nanoscales, the impact of the molecular interaction forces between fluids and solids becomes increasingly important. These forces can alter macroscopic fluid phase behavior and control transport. Recent experimental studies have shown that capillary condensation and subsequent imbibition of liquid water can occur in hydrophilic nanoporous media even if the vapor phase is at a critical relative humidity (rhcrit) well below vapor saturation. This study presents a theoretical investigation of the processes controlling adsorption, capillary condensation and imbibition in nanoporous media, using the square-gradient classical density functional theory. The proposed theoretical model explicitly includes the relevant interaction forces among fluids and solids in macroscopic porous media. Application of the model to a relative-humidity-controlled water adsorption experiment is presented to demonstrate the impact of water-pore wall attractive forces on multiphase water behavior in a hydrophilic silicon nanoporous medium. Here, the model represents well the measured time-dependent evolution of the water imbibition front inside the nanoporous medium and also explains the diffusion-like water transport regimes observed at rh < rh crit and the imbibition-like flow regimes observed at rh > rh crit . The study furthermore gives an insight on hysteresis phenomenon in adsorption and desorption isotherms.

58 GEOSCIENCES↗

The shuttle orbiter cabin atmospheric revitalization systems

The Orbiter Atmospheric Revitalization Subsystem (ARS) and Pressure Control Subsystem (ARPCS) are designed to provide the flight crew and passengers with a pressurized environment that is both life-supporting and within crew comfort limitations. The ARPCS is a two-gas (oxygen-nitrogen) system that obtains oxygen from the Power Reactant Supply and Distribution (PRSD) subsystem and nitrogen from the nitrogen storage tanks. The ARS includes the water coolant loop; cabin CO2, odor, humidity and temperature control; and avionics cooling. Baseline ARPCS and ARS changes since 1973 include removal of the sublimator from the water coolant loop, an increase in flowrates to accommodate increased loads, elimination of the avionics bay isolation from the cabin, a decision to have an inert vehicle during ferry flight, elimination of coldwall tubing around windows and hatches, and deletion of the cabin heater.

Ward, C. F.↗

Lower Tropospheric Processes: A Control on the Global Mean Precipitation Rate

The spread in global mean precipitation among climate models is explored in two ensembles using the complementary perspectives of surface evaporation and energy budgets. Models with higher global mean precipitation have stronger oceanic evaporation, driven by drier near-surface air. The drier surface conditions occur alongside increases in near-surface temperature and moisture at 925 hPa, which point to stronger boundary layer mixing. Correlations suggest that the degree of lower tropospheric mixing explains 18%–49% of the intermodel precipitation variance. To test this hypothesis, the degree of mixing is indirectly varied in a single-model experiment by adjusting the relative humidity threshold that controls low-cloud fraction. Indeed, increasing lower tropospheric mixing results in more global mean precipitation. Energetically, increased precipitation rates are associated with more downwelling longwave radiation to the surface and weaker sensible heat fluxes. These results highlight how lower-tropospheric processes must be better constrained to reduce the precipitation discrepancy among climate models.

58 GEOSCIENCES↗

Long Term Performance Stability of TES Detectors

We are developing superconducting transition-edge sensor (TES) microcalorimeter arrays for a variety of applications such as ground-based laboratory astrophysics experiments and next generation space-based X-ray missions. These detectors can provide X-ray spectral information with an unprecedent resolution of ~2 eV at 6 keV and have been selected for the X-ray Integral Field Unit (X-IFU) instrument of ESA’s large flagship mission Athena. To maintain detector performance over the lifetime of the mission, it is important to understand whether environmental conditions that the detector may be exposed to will affect its properties over time. This “aging” begins right after the array leaves the fabrication environment, with potential exposure to humidity, oxygen, or elevated temperatures which may affect the detector performance. In a few prior arrays we have observed increased fall times in the pulse shape and/or the introduction of anomalous low energy tails on the X-ray spectrum. This is thought to be an indication of “aging” on chips exposed to such conditions, causing e.g. changes in the absorber properties. In this contribution, we report on a systematic characterization of TES properties, before and after exposing the chip to various controlled temperature and humidity levels and assess the changes in the measured transition and pulse shapes, energy resolution, and spectral redistribution.

S Beaumont↗

Influence of Deep Convection on Cirrus and Water Vapor Concentration in the Upper Troposphere and Lower Stratosphere

It is well known that stratospheric humidity is primarily controlled by freeze drying (ice crystal growth and sedimentation) of air ascending across the cold tropical tropopause. However, the suggestion of an important source of water vapor from deep convection that extends above the tropical tropopause has persisted. There exists much anecdotal evidence of direct convective hydration of the lower stratosphere based on measurements from high altitude aircraft campaigns, but quantifying the impact of deep convection on the overall budget of stratospheric water vapor has proven challenging. The role of convection on the humidity of the upper troposphere and lower stratosphere (UTLS) is investigated in simulations of cirrus clouds along trajectories launched from given potential temperature level surfaces. The one-dimensional (vertical) cloud model tracks individual ice crystals through their life cycles, beginning with nucleation or detrainment from convection, followed by deposition growth, sedimentation and sublimation. Convective influence of the parcels is diagnosed by tracing the trajectories through time-dependent fields of convective cloud-top height adjusted to match the CloudSAT and CALIPSO statistics. Model simulations of UTLS water vapor and cloud fields are evaluated and constrained by comparison with MLS and CALIPSO measurements. The simulation results indicate that the overall impact of convection on water vapor near the tropical tropopause is 10-15%, while the impact on lower stratospheric humidity is no more than a few percent. Ice crystals detrained from deep convection have relatively small effect. The general implications for the importance of deep convection on UTLS humidity and cirrus cloud fraction will be discussed.

Ueyama, Rei↗

Somatic Mutation in Mice on the International Space Station (ISS): Guanine Substitution Suggests Link to Cancer Risk

We conducted comprehensive analysis of single nucleotide somatic mutations in mice exposed to microgravity and other factors aboard the International Space Station (ISS), using data archived in GeneLab. Animals in the experimental cohort consisted of mice that spent 37 days on the ISS within the Rodent Habitat. Ground control animals consisted of mice of identical age, sex, strain, in a terrestrial Rodent Habitat controlled for temperature, humidity and carbon dioxide levels, to match ISS conditions as closely as possible. RNA extracted from eye, liver, skeletal muscle, and kidney tissue specimens was subjected to next-generation sequencing to acquire primary data. Our analysis employed cutting-edge software developed at NASA Ames Research Center, executed on the NASA Ames Supercomputer and on another high-performance computer, for accurate variant calling of single point mutations. ISS-flown mice exhibited a notably heightened level of somatic mutation compared to control mice. The degree of somatic mutation correlated with the degree of gene expression across the four tissue types, i.e., the greatest rate of mutation accumulation was seen in highly expressed genes. We discovered that guanine substitutions were the most common type of somatic mutation. This observation is consistent with the hypothesis that DNA mutation events stem from reactive oxygen/nitrogen/chlorine species-mediated guanine oxidation induced by the spaceflight environment. Since guanine oxidation is a prominent feature of the DNA mutation landscape that accompanies malignant transformation, our findings suggest a possible link between the spaceflight environment and cancer risk that is independent of radiation carcinogenesis.

ISS↗

Effectiveness of Rain Cleaning on Artificially Soiled PV Modules With and Without Anti-Soiling Coatings

A simple, inexpensive methodology for testing the effectiveness of rain cleaning on artificially soiled single-cell and multi-cell photovoltaic (PV) modules having anti-soiling coatings has been developed. Using an indoor soil deposition chamber and methodology as described in our previously published work, multiple layers of soil were deposited on to the glass surface of single-cell PV modules subjected to controlled temperature and humidity cycles. Three single-cell monocrystalline PV modules are reported in this study, two of which had different anti-soiling (AS) coatings applied to the surface and the third did not have any AS coating. The set-up and operation of a rain-simulator is described as well as the rain cleaning parameters the PV test modules were exposed to. The purpose of this work is to determine the effectiveness of anti-soiling coatings and cleaning techniques, so vendor claims can be quantitatively validated using an appropriately controlled soil deposition chamber and a rain simulating spray nozzle.

14 SOLAR ENERGY↗

Development of the Plant Growth Facility for Use in the Shuttle Middeck and Test Units for Ground-Based Experiments

The plant growth facility (PGF), currently under development as a Space Shuttle middeck facility for the support of research on higher plants in microgravity, is presented. The PGF provides controlled fluorescent lighting and the active control of temperature, relative humidity and CO2 concentration. These parameters are designed to be centrally controlled by a dedicated microprocessor. The status of the experiment can be displayed for onboard analysis, and will be automatically archived for post-flight analysis. The facility is designed to operate for 15 days and will provide air filtration to remove ethylene and trace organics with replaceable potassium permanganate filters. Similar ground units will be available for pre-flight experimentation.

Chapman, David K.↗

Microgravity Effecs During Fertilization, Cell Division, Development, and Calcium Metabolism in Sea Urchins

Calcium loss and muscle atrophy are two of the main metabolic changes experienced by astronauts and crew members during exposure to microgravity in space. For long-term exposure to space it is crucial to understand the underlying mechanisms for altered physiological functions. Fundamental occurrences in cell biology which are likely to depend on gravity include cytoskeletal dynamics, chromatin and centrosome cycling, and ion immobilization. These events can be studied during fertilization and embryogenesis within invertebrate systems. We have chosen the sea urchin system to study the effects of microgravity on cytoskeletal processes and calcium metabolism during fertilization, cell division, development, and embryogenesis. Experiments during an aircraft parabolic flight (KC-135) demonstrated: (1) the viability of sea urchin eggs prior to fertilization, (2) the suitability of our specimen containment system, (3) the feasibility of fertilization in a reduced gravity environment (which was achieved during 25 seconds of reduced gravity under parabolic flight conditions). Two newly developed pieces of spaceflight hardware made further investigations possible on a spaceflight (STS-77); (1) the Aquatic Research Facility (ARF), and (2) the Fertilization Syringe Unit (FSU). The Canadian Space Agency developed ARF to conduct aquatic spaceflight experiments requiring controlled conditions of temperature, humidity, illumination, and fixation at predetermined time points. It contained a control centrifuge which simulated the 1 g environment of earth during spaceflight. The FSU was developed at the Kennedy Space Center (KSC) by the Bionetics Corporation specifically to enable the crew to perform sea urchin fertilization operations in space.

Schatten, Heide↗

Environmental Testing of Contamination Sensitive Instruments and Optics in Non-Cleanliness Controlled Facilities

The James Webb Space Telescope (JWST) Optical Telescope Element + Integrated Science Instrument Module (OTIS) went through environmental testing at the Goddard Space Flight Center. The vibration and acoustic tests occurred outside of cleanrooms. These areas are typically around ISO Class 8, far out of specifications for JWST. Through collaboration between the OTIS Mechanical and Contamination Engineering teams, a portable clean enclosure was designed, built, and verified to prevent contamination of the sensitive OTIS assembly. This manuscript describes the process of designing and building this enclosure, including materials selection and High Efficiency Particle Air (HEPA) filtration. This enclosure also provided environmental control with a portable air conditioning unit to control the relative humidity level enabling personnel to work within it. The manuscript emphasizes working in a systematic order to maintain cleanliness and integrity. “Clean as you go” during construction was a top priority to ensure that this critical Ground Support Equipment (GSE) was acceptable. The process of installing the walls and then sealing their internal and external surfaces with approved films was critical to maintaining OTIS integrity. This proved important because OTIS was in the enclosure for months longer than originally planned. This manuscript concludes by reviewing the process used to verify that the OTIS clean enclosure could achieve acceptable contamination level fallout accumulation for use during the vibration and acoustic testing and then verifying that the predicted performance was achieved after testing was complete.

Contamination Control, James Webb Space Telescope,↗

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing Turbulent Mixing and Microphysical Uniformity in a Tall Convection‐Cloud Chamber Through Idealized Heterogeneity of Boundaries

A large convection cloud chamber has been proposed for exploring aerosol–cloud–drizzle interactions under well‐controlled turbulent conditions. Recent theoretical and numerical studies suggest that a convection cloud chamber with two heated and two cooled sidewalls can significantly enhance the liquid water content and thus benefit drizzle initiation. However, a chamber with such a sidewall configuration develops stable stratification and extremely weak turbulence therein. In this study, we conduct large‐eddy simulations of a tall convection chamber with five different sidewall configurations consisting of alternating warm and cold patches. For each configuration, the total surface area of warm patches equals that of cold patches, resulting in the same expected cloud‐free supersaturation based on a flux budget model. Results show that changing the sidewall configuration, while keeping all other factors constant, can substantially enhance turbulent mixing and improve the uniformity of thermodynamic and cloud microphysical properties in the bulk region of the chamber. In addition, turbulence strength is positively correlated with liquid water content and negatively correlated with cloud droplet number concentration, consistent with theoretical predictions. Our results highlight the advantage of building a large cloud chamber using modular patches with individually controllable temperature and humidity to achieve well‐mixed conditions.

54 ENVIRONMENTAL SCIENCES↗

Artificial Soiling Replication of Field Losses on Commercial Photovoltaic Modules

Here, this study demonstrates the capabilities of an indoor artificial soiling approach developed to closely replicate the natural, cyclic soil accumulation processes in the field-dust suspension, deposition, and sedimentation/cementation-for a subtropical climate. In this work, a near-field environment is replicated in an artificial soiling cubic chamber through controlled regulation of humidity, temperature, dust type, and dust concentration, based on site-specific historical climate data. Two different models (MA and MB) of full-size commercial photovoltaic modules from a single manufacturer, installed side by side in the mid-Atlantic United States, were retrieved and subjected to artificial soiling experiments and various characterization measurements, including short-circuit current, colorimetry, reflectance, X-ray fluorescence, laser diffraction, and optical microscopy. Both in the field and in our improved field-representative artificial soiling tests, the MA model experienced roughly twice the soiling loss as the MB model. To closely replicate the field soiling losses for a site-specific climate, it is critical to include: 1) The use of field-collected dust with identical dust chemistry and particle distribution instead of standardized ISO 12103 Arizona Road dusts, 2) the use of only a small amount of field-collected dust inside the chamber during the deposition process (e.g., 0.15 g), and 3) the preconditioning of the surface coating for the partial/full dose of UV stress as experienced in the field during sunlight exposure and the abrasion as experienced in the field during regular module cleaning activities, if/as needed. The field-representative artificial soiling method developed here could potentially be adopted for rank ordering of various antisoiling coatings developed by researchers and industry stakeholders.

14 SOLAR ENERGY↗

Benchtop-Scale High Temperature Molten Salt Electrochemical Reactors: Experimental Setup and Considerations

Molten salt electrochemical reduction (MSER) is the dominant production method for aluminum and titanium, and emerging technologies for producing other commodity metals with these highly electrified techniques have demonstrated promising results. However, the scale up of MSER of materials such as iron and silicon are limited by the challenging issues of materials compatibility and impurity control. This work describes an experimental MSER setup using both chloride and carbonate salts. This setup is designed for operations outside of a glovebox, which is practical from an industrial perspective, but creates unique challenges. This work serves as a practical guide to discuss some key operational difficulties such as temperature control, air and humidity, material compatibility, developing strong electrical measurements and techniques, and safety.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SPACECRAFT LIFE SUPPORT SYSTEMS

Requirements of life support for the crew members considered in relation to man's metabolic requirements Appropriate methods and equipment are related to these characteristics of various manned space missions. Among the provisions required for maintaining physical well-being are systems for (1) the removal of carbon dioxide, (2) the reclamation and supplying of oxygen, (3) the control of temperature, humidity, and toxic gases, (4) the reclamation of water, (5) the management of wastes, and (6) the supplying of food. Some of the research being performed at the Langley Research Center with life support systems is discussed and the research objectives are stressed. Descriptions are given of the various types of equipment used in this research, together with criteria for system evaluations.

MANNED SPACECRAFT↗

Breathing-metabolic simulator

Breathing-metabolic simulator was developed to be used for evaluation of life support equipment. Apparatus simulates human breathing rate and controls temperature and humidity of exhaled air as well as its chemical composition. All functions are designed to correspond to various degrees of human response.

Bartlett, R. G.↗