At least 289 records · Page 16

Development of a wind turbine model and simulation platform using an acausal approach: Multiphysics modeling, validation, and control

This article presents the development of the Control-oriented, Reconfigurable, and Acausal Floating Turbine Simulator (CRAFTS). CRAFTS has a modular, hierarchical model architecture that enables rapid and accurate simulation of wind turbines. The architecture facilitates the incorporation of model variants, and its system reconfiguration features help simulate multiple design variants. CRAFTS also supports the integration of models developed on a causality-free platform (e.g., Modelica®) with existing causal models. This article focuses on the validation of a land-based wind turbine models against OpenFAST, an industry-standard platform, for several test cases. Closed-loop scenarios are also tested using the standard ROSCO controller and compared against OpenFAST. In addition, a nonlinear controller developed in our prior work is also evaluated. The test cases demonstrate the user-friendly and computationally efficient capabilities of CRAFTS to facilitate control co-design, assist in incorporating multiphysics models, be adaptable to design variants, and allow for rapid simulations to validate models and evaluate controllers.

17 WIND ENERGY↗

Neural network model of the multi-mode anomalous transport module for accelerated transport simulations

Here, a neural network version of the Multi-Mode Anomalous Transport Module, known as MMMnet, has been developed to calculate plasma turbulent diffusivities in DIII-D with a calculation time suitable for control applications. MMMnet uses a simple artificial neural network structure to predict the ion thermal, electron thermal, and toroidal momentum diffusivities while reproducing Multi-Mode Model (MMM) data with good accuracy and keeping the calculation time as a fraction of that associated with MMM. Model-based control techniques require models with fast calculation times, making many existing physics-oriented predictive codes unsuitable. The control-oriented predictive code COTSIM (Control Oriented Transport SIMulator) calculates the most significant plasma dynamics in response to the different actuators while running at a speed useful for control design. In order to achieve this calculation speed, COTSIM often relies on scaling laws and control-level models. Replacing some of these scaling laws and control-level models with neural network versions of more complex physics-level models has the potential of increasing the range of validity and the level of accuracy of COTSIM without compromising its computational speed. In this work, MMMnet is integrated into COTSIM to improve the turbulent diffusivity predictions, which will in turn improve the prediction accuracy associated with the dynamics of many plasma properties.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Maximum-impact Adversary Design for Network-based Control System: A Case Study on Grid-interactive Efficient Buildings

The Internet of Things (IoT) technology has dramatically improved the efficiency of today's building operation and management. By connecting controllable devices into a communication network, control signals can be easily passed to the devices, and operating status can be acquired from measurable ends with minimal effort. However, this all-connected configuration could also expose the network-based control system (NBCS) to malicious actions, such as cyberattacks. One of the common NBCSs is the building automation system. With the promotion of grid-interactive efficient buildings (GEBs), there has been increasing attention on securing the buildings from the network perspective. This research proposes a maximum-impact adversary design framework so that the adversary can provide the most adversarial impact on the controlled system while remaining stealthy. The proposed framework is numerically demonstrated on a network-based building energy and control system. The building energy system is built in a Modelica-based simulation environment and controlled by the state-of-the-art ASHRAE Guideline 36 control sequences. The control commands at the supervisory level, generated from the Guideline 36 controller, are assumed to be sent to local devices through communication networks using the BACnet protocol. Simulation results show that the proposed maximum-impact adversary on such a system can stealthily affect the building system's performance to its maximum extent. It is anticipated that results can be used by researchers and practitioners in the building automation industry to design efficient and robust cyber-attack detection algorithms, especially for stealthy attacks.

Chu, Mengyuan↗

Model predictive control for voltage restoration in microgrids using temporal logic specifications

Power system operation will encounter numerous voltage variabilities as the proliferation of renewable energy continues. Real-time monitoring and communication technologies can potentially improve voltage stability by enabling the rapid detection of voltage deviations and the implementation of corrective actions. These corrective actions will only be effective in restoring stability if they are chosen in a timely and scalable manner. This paper considers the problem of power systems’ load voltage control in order to simultaneously address both magnitude and time voltage specifications. In order to comply with grid codes and avoid unnecessary relay protection actions, a model predictive control (MPC)-based control strategy employing temporal logic specifications (TLSs) is proposed. The TLSs strategy is introduced as a formalism to control the voltage variation at a critical load bus against operational bounds over time. The control objective is to schedule optimal control input signals from the available supportive energy storage systems, which provide reactive power injections, leading to satisfying the specified finite-time restoration described by the TLSs with minimal control efforts. The simulation results display that the TLSs strategy for power systems’ voltage control synthesis is extremely significant.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digital Twin + AI: Control Room of the Future

A digital twin enhances power grid control room operations by providing real-time monitoring, predictive insights, simulation capabilities, remote control, training opportunities, data integration, and decision support. This technology empowers control room operators to effectively manage the grid, optimize performance, and ensure reliable and efficient energy distribution.

control room of the future↗

Fuel Fabrication and Single Stage Aqueous Process Modeling

The Material Protection, Accounting, and Control Technologies program utilizes modeling and simulation to assess Material Control and Accountability (MC&A) concerns for a variety of nuclear facilities. Single analyst tools allow for rapid design and evaluation of advanced approaches for new and existing nuclear facilities. A low enriched uranium (LEU) fuel conversion and fabrication facility simulator is developed to assist with MC&A for existing facilities. Measurements are added to the model (consistent with current best practices). Material balance calculations and statistical tests are also added to the model. In addition, scoping work is performed for developing a single stage aqueous reprocessing model. Preliminary results are presented and discussed, and next steps outlined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Variational control forces for enhanced sampling of nonequilibrium molecular dynamics simulations

We introduce a variational algorithm to estimate the likelihood of a rare event within a nonequilibrium molecular dynamics simulation through the evaluation of an optimal control force. Optimization of a control force within a chosen basis is made possible by explicit forms for the gradients of a cost function in terms of the susceptibility of driven trajectories to changes in variational parameters. We consider probabilities of time-integrated dynamical observables as characterized by their large deviation functions and find that in many cases, the variational estimate is quantitatively accurate. Additionally, we provide expressions to exactly correct the variational estimate that can be evaluated directly. We benchmark this algorithm against the numerically exact solution of a model of a driven particle in a periodic potential, where the control force can be represented with a complete basis. Additionally, we then demonstrate the utility of the algorithm in a model of repulsive particles on a line, which undergo a dynamical phase transition, resulting in singular changes to the form of the optimal control force. In both systems, we find fast convergence and are able to evaluate large deviation functions with significant increases in statistical efficiency over alternative Monte Carlo approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probability Density Function Control for Stochastic Nonlinear Systems using Monte Carlo Simulation

This paper presents a fast implementation framework of output probability density function (PDF) control for a class of stochastic nonlinear systems which are subjected to non-Gaussian noises. The statistical properties of the system outputs can be adjusted by shaping the dynamic output probability density function to track the reference stochastic distribution. However, the dynamic probability density function evolution is very difficult to obtain analytically even if the system model and the stochastic distributions of the noises are known. Motivated by Monte Carlo simulation, the dynamic probability density function can be estimated by sampling data which forms the contribution of this paper. In particular, the sampling points are generated following the stochastic distribution of the noise for each instant. These points go through the system would generate the histogram for system outputs, then the dynamic model can be established based on the dynamic histogram which reflects the randomness and the nonlinear dynamics of the investigated system. Based on the established model, the output probability density function tracking can be achieved and the simulation results and discussions show the effectiveness and benefits of the presented framework.

Zhang, Qichun↗

Crosslinking and Gelation of Polymer Brushes and Free Polymer Chains in a Confined Space during Controlled Radical Polymerization-A Computer Simulation Study

The confinement effect on crosslinking and gelation during controlled/living copolymerization of a monovinyl and a divinyl monomer was studied by Monte Carlo computer simulation using the dynamic lattice liquid method. The simulated reactions took place in plane-parallel slits of various widths for various grafting densities (GDs) and various initial initiator/crosslinker ratios ([X] 0 /[Ini] 0 ). Monomers and crosslinkers were initially randomly distributed in the slit, but initiators were either anchored to one solid plane (polymer brushes) or randomly distributed (free chains). For brushes, the gel point (GP) depended on GD and [X] 0 /[Ini] 0 . The higher these parameters, the lower was the gel point. The gel point was also affected by the slit width. For free, nongrafted chains, the dependence of GP on slit width was negligible. For brushes, a nonuniform density of crosslinks was found, the highest density was close to the wall. This asymmetry was high at the gel point and decreased at higher conversions.

36 MATERIALS SCIENCE↗

Data and scripts associated with “When do Riverine Systems 'Feel the Burn'? Simulating How Burn Extent and Severity Modulate Hydrologic Controls on Biogeochemical Export” (v2)

This data package is associated with the publication “When do Riverine Systems 'Feel the Burn'? Simulating How Burn Extent and Severity Modulate Hydrologic Controls on Biogeochemical Export” published in Water Resources Research (Wampler et al. 2025; preprint: https://doi.org/10.22541/essoar.174438106.63564767/v1). This study used the Soil and Water Assessment Tool (SWAT), a processed based model to explore the impacts of area burned and burn severity on streamflow, nitrate, and dissolved organic carbon (DOC) in two test basins: a semi-arid, mixed land use basin and a humid, primarily forested basin. We developed 1800 wildfire scenarios that we ran in each basin: 20 different burn extents (5 to 100% by 5%), 3 different burn severities (low, moderate, and high), and 30 different post-fire precipitation scenarios. We also ran an additional 30 scenarios associated with no wildfire for the 30 post-fire precipitation scenarios. For each scenario we were interested in the change in runoff ratio (streamflow) and average concentration and annual loads (nitrate and DOC) across the wildfire scenarios. This data package contains the data and scripts required to build SWAT models for the two test basins, create and run the wildfire scenarios, and generate the data summaries and figures used in the associated manuscript. This data package was originally published in March 2025. It was updated in January 2026 (v2; new and modified files) to include the final files after the manuscript went through reviews. See the change history section below for more details. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About.

54 ENVIRONMENTAL SCIENCES↗

Prediction of Substrate Distortion in Powder DED Using Finite Element Model

Abstract Leveraging the capabilities of both additive and subtractive manufacturing to repair tooling and other high value items can result in significant cost and time saving opportunities. However, when dimensional accuracy of the repaired component must be held within a specified tolerance, distortion of the component induced during repair can lead to an out of specification final component. This work presents simulation of a novel method to mitigate part distortion using sacrificial support structures. A blown powder directed energy deposition system was utilized for deposition of sacrificial support structures and clad surface depositions. Sacrificial support structures were deposited on the underside of the substrate with varying geometries prior to clad surface depositions. A finite element model was developed and verified using experimental results. The simulation and experimental control results were found to match within 6%. It has been shown that simulation can be used to predict effects of sacrificial support structures on substrate distortion in a blown powder directed energy deposition process.

Burl, Alan G.↗

Steric Sea Level Rise and Relationships with Model Drift and Water Mass Representation in GFDL CM4 and ESM4

Abstract Density-driven steric seawater changes are a leading-order contributor to global mean sea level rise. However, intermodel differences in the magnitude and spatial patterns of steric sea level rise exist at regional scales and often emerge during the spinup and preindustrial control integrations of climate models. Steric sea level results from an eddy-permitting climate model, GFDL CM4, are compared with a lower-resolution counterpart, GFDL-ESM4. The results from both models are examined through basin-scale heat budgets and watermass analysis, and we compare the patterns of ocean heat uptake, redistribution, and sea level differ in ocean-only [i.e., Ocean Model Intercomparison Project (OMIP)] and coupled climate configurations. After correcting for model drift, both GFDL CM4 and GFDL-ESM4 simulate nearly equivalent ocean heat content change and global sea level rise during the historical period. However, the GFDL CM4 model exhibits as much as a 40% increase in surface ocean heat uptake in the Southern Ocean and subsequent increases in horizontal export to other ocean basins after bias correction. The results suggest regional differences in the processes governing Southern Ocean heat export, such as the formation of Antarctic Intermediate Water (AAIW), Subpolar Mode Water (SPMW), and gyre transport between the two models, and that sea level changes in these models cannot be fully bias-corrected. Since the process-level differences between the two models are evident in the preindustrial control simulations of both models, these results suggest that the control simulations are important for identifying and correcting sea level–related model biases.

Krasting, John P. [a NOAA/OAR/Geophysical Fluid Dy↗

Rapid QSTS Simulations for High-Resolution Comprehensive Assessment of Distributed PV

The rapid increase in penetration of distributed energy resources on the electric power distribution system has created a need for more comprehensive interconnection modeling and impact analysis. Unlike conventional scenario-based studies, quasi-static time-series (QSTS) simulations can realistically model time-dependent voltage controllers and the diversity of potential impacts that can occur at different times of year. However, to accurately model a distribution system with all its controllable devices, a yearlong simulation at 1-second resolution is often required, which could take conventional computers a computational time of 10 to 120 hours when an actual unbalanced distribution feeder is modeled. This computational burden is a clear limitation to the adoption of QSTS simulations in interconnection studies and for determining optimal control solutions for utility operations. The solutions we developed include accurate and computationally efficient QSTS methods that could be implemented in existing open-source and commercial software used by utilities and the development of methods to create high-resolution proxy data sets. This project demonstrated multiple pathways for speeding up the QSTS computation using new and innovative methods for advanced time-series analysis, faster power flow solvers, parallel processing of power flow solutions and circuit reduction. The target performance level for this project was achieved with year-long high-resolution time series solutions run in less than 5 minutes within an acceptable error.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Heat pump water heater enhanced with phase change materials thermal energy storage: Modeling study

A promising solution to improve the first hour rating (FHR) of a heat pump water heater (HPWH) involves employing a secondary tank which contains phase change material (PCM) capsules. To better understand the influence of PCM thermal storage on the HPWH operational performance, a dynamic model was developed to simulate and analyze the behavior of a newly developed HPWH technology that incorporates PCM storage into a standard HPWH to optimize key parameters such as the uniform energy factor and FHR. Mathematical models of several key components of the proposed HPWH-PCM integrated thermal energy storage (TES) system, e.g., water heater tank, PCM TES tank, evaporator, compressor, and expansion valve, have been elaborated. Also, a model-based control co-simulation platform was developed to integrate a embed PCM storage HPWH dynamic model with a control model for better supporting control design, analysis, verification, and validation. The model accuracy has been validated through comparing simulation results with lab test results, with a mean average percentage error of <5.5% for most of the selected performance variables. In addition, using the developed co-simulation platform, the demand response control strategy was studied to evaluate the load flexibility of the combined HPWH-PCM storage system by shifting system power usage to outside of the 3.5 h peak load period.

25 ENERGY STORAGE↗

Interactive Power to Frequency Dynamics Between Grid-Forming Inverters and Synchronous Generators in Power Electronics-Dominated Power Systems

With increased attention on grid-forming inverters as a power system stabilizing device during high shares of inverter-based resource operations, there is a present need for a transparent and methodical investigation of the inverted and direct power to frequency control capabilities and impacts of these devices on emerging power systems. Here, analysis of the frequency dynamics of the droop-controlled grid-forming inverter and the synchronous generator illuminates the inverted active power-frequency relationship and the frequency response order reduction, forming the basis for novel, nonlinear frequency control approaches. Device-level electromagnetic transient domain simulations corroborate the order-reduction findings, establish that a properly designed dc-side system has a negligible impact on power transfer and will not impede frequency regulation, and confirm the primary frequency response improvement with nonlinear control. Simulations of the 9- and 39-bus test systems validate the order reduction and associated decoupling of the nadir and rate of change of frequency in larger networks. Oscillatory mode analysis confirms the grid-forming benefit of increased damping; decreased damping is observed at shares above 80%, but not at 100%. Finally, simulations on a validated Maui power system model with a 96% of inverter-based resources model yield a trend toward a first-order response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Simulation and Analysis of Occupancy-Based Control for Office Buildings with Variable-Air-Volume Systems

Variable-air-volume (VAV) systems are used in many office buildings. The minimum airflow rate setting of VAV terminal boxes has a significant impact on both energy consumption and indoor air quality. Conventional controls usually have the terminal’s minimum airflow rate at a constant (e.g., 30% or more of the terminal design airflow rate), irrespective of the occupancy status, which may cause problems, such as excessive simultaneous heating and cooling, under ventilation, and thermal comfort issues. This paper examines the potential of energy savings from occupancy-based controls (OBCs). The sensed occupancy information, either occupant presence or people count, is used to determine the airflow rate of terminal boxes, the thermostat setpoints, and the lighting control. Using EnergyPlus, a whole-building energy modeling software, the energy savings of OBC strategies are evaluated for representative existing medium office buildings in the U.S. The simulation results show that the conventional OBC, based on occupant presence sensing, can save 8% of whole-building energy use in Miami (hot climate) for systems without air-side economizer and about 13% in both Baltimore (mixed climate) and Chicago (cold climate). Comparatively, the advanced OBC, based on people counting, can save 8% in Miami to 23% in Baltimore for systems with economizers. The outdoor-air fraction of the supply air from air-handling units significantly affects the potential energy savings from the advanced OBC strategy. In addition to energy savings, the advanced OBC satisfies the zone ventilation during all occupied hours over the whole year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Distributed Wind Turbine Controls Series: Part 2-Wind Energy in Isolated Grids – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In an isolated grid, wind turbines are typically deployed to provide energy to maximize energy production, reduce diesel-fuel consumption, reduce carbon emissions, and reduce costs for energy and fuel transportation. However, in addition to solely providing energy to the power system, wind turbines contain rotating masses and inverter-based controls that can enable various reliability and resilience services through advance controls. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, advanced wind turbine controls that can be employed to support higher contributions of wind in isolated grids, and to demonstrate ways that wind can play a role in supporting stability of an isolated grid. This isolated grid used in these desktop simulations is comprised of a wind turbine (600 kW), solar PV (430 kW), battery energy storage system (1 MW/1MWh), a simulated diesel generator (2 MW) and various types of loads (critical, dynamic). We developed a model of the subsystems in MATLAB/Simulink and validated them with available data from real-world components on NREL's Flatirons Campus. These validated models are then configured for various case studies. We compare the output of the desktop simulation with a baseline case with the diesel generator. Active and reactive power control of the wind turbine can help improve frequency and voltage responses in the isolated grid, respectively. By utilizing a small integrated battery energy storage system in the DC-link of the wind turbine, we also demonstrate that wind turbines can help blackstart a critical load comparable to its rated power and support other renewables (e.g. solar PV) come online and pick up an additional load. This report illustrates some of these reliability and resilience services a wind turbine can provide in an isolated grid.

17 WIND ENERGY↗