Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “connect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

The cross-aisle seismic performance of storage rack base connections

Steel storage racks used in retail stores and warehouses are seismically designed as moment resisting frames in the down-aisle direction, and braced frames in the cross-aisle direction. While their down-aisle response is relatively well understood, there is little understanding of their cross-aisle response, especially as it pertains to the desired mode of inelastic deformation and associated design methods. In this paper, results are presented from six full scale tests on braced frames representing storage racks in the cross-aisle direction. These tests investigate the base plate thickness and dimensions, and the upright (column) cross section. The experiments indicate that inelastic deformation in the base plate provides stable hysteretic response with significant ductility and energy dissipation. Ductile tearing is also observed in welds connecting the base plate to the upright. However, it does not appear to negatively influence the hysteretic response. The tests are complemented by Finite Element (FE) simulations of the base connections. These simulations provide insights into internal force distributions within the connections. Based on these insights, analytical equations are proposed for characterizing the backbone curve of the hysteretic response, for use in displacement based design methods. It is determined that the current approach for characterizing design forces in the anchors is unconservative, since it does not incorporate the effects of strain hardening or the membrane action as the base plate undergoes large deformations. A new approach which incorporates these phenomena is presented, and determined to be significantly more accurate. Finally, limitations of the study are outlined and directions for future work are identified.

36 MATERIALS SCIENCE↗

At the interfaces of the hydrologic sciences: Connecting water, elements, ecosystems, and people through the major contributions of Dr. Emily Bernhardt

Here, in this paper, we describe the major contributions of Professor Emily Bernhardt to the hydrologic sciences. Dr. Bernhardt’s work addresses how carbon, nutrient, and contaminant dynamics respond to a wide range of environmental perturbations that alter hydrologic dynamics within and connectivity among ecosystems. Her research leverages intensive and extensive field sampling, experimental manipulations, macroscale data harmonization and exploration, and continental to global-scale synthesis activities to uncover key drivers and patterns of the impacts human perturbations have on water and elemental cycles. Dr. Bernhardt’s research program is defined by her ability to ask questions and use approaches that explicitly consider connectivity and interfaces in a variety of ways. Here, we highlight significant contributions from Dr. Bernhardt’s work, organized by connectivity, interfaces, and interactions among and across (1) elemental cycles, (2) ecosystems, (3) watersheds, (4) scales, and (5) disciplines. We conclude with a section on Dr. Bernhardt’s impact on the hydrologic sciences and beyond through her exceptional dedication to mentorship, engagement, and service.

58 GEOSCIENCES↗

Parallel algorithms for finding connected components using linear algebra

Finding connected components is one of the most widely used operations on a graph. Optimal serial algorithms for the problem have been known for half a century, and many competing parallel algorithms have been proposed over the last several decades under various different models of parallel computation. This paper presents a class of parallel connected-component algorithms designed using linear-algebraic primitives. These algorithms are based on a PRAM algorithm by Shiloach and Vishkin and can be designed using standard GraphBLAS operations. Here, we demonstrate two algorithms of this class, one named LACC for Linear Algebraic Connected Components, and the other named FastSV which can be regarded as LACC’s simplification. With the support of the highly-scalable Combinatorial BLAS library, LACC and FastSV outperform the previous state-of-the-art algorithm by a factor of up to 12x for small to medium scale graphs. For large graphs with more than 50B edges, LACC and FastSV scale to 4K nodes (262K cores) of a Cray XC40 supercomputer and outperform previous algorithms by a significant margin. This remarkable performance is accomplished by (1) exploiting sparsity that was not present in the original PRAM algorithm formulation, (2) using high-performance primitives of Combinatorial BLAS, and (3) identifying hot spots and optimizing them away by exploiting algorithmic insights.

97 MATHEMATICS AND COMPUTING↗

Tau covariance patterns in Alzheimer's disease patients match intrinsic connectivity networks in the healthy brain

According to the network model of neurodegeneration, the spread of pathogenic proteins occurs selectively along connected brain regions. We tested in vivo whether the distribution of filamentous tau (measured with [ 18 F]flortaucipir-PET), fibrillar amyloid-β ([ 11 C]PIB-PET) and glucose hypometabolism ([ 18 F]FDG-PET) follows the intrinsic functional organization of the healthy brain. We included 63 patients with Alzheimer's disease (AD; 30 male, 63 ± 8 years) who underwent [ 18 F]flortaucipir, [ 11 C]PIB and [ 18 F]FDG PET, and 1000 young adults (427 male, 21 ± 3 years) who underwent task-free fMRI. We selected six predefined disease epicenters as seeds for whole-brain voxelwise covariance analyses to compare correlated patterns of tracer uptake across AD patients against fMRI intrinsic connectivity patterns in young adults. We found a striking convergence between [18F]flortaucipir covariance patterns and intrinsic connectivity maps (range Spearman rho's: 0.32-0.78, p < .001), which corresponded with expected functional networks (range goodness-of-fit: 3.8-8.2). The topography of amyloid-β covariance patterns was more diffuse and less network-specific, while glucose hypometabolic patterns were more spatially restricted than tau but overlapped with functional networks. These findings suggest that the spatial patterns of tau and glucose hypometabolism observed in AD resemble the functional organization of the healthy brain, supporting the notion that tau pathology spreads through circumscribed brain networks and drives neurodegeneration.

60 APPLIED LIFE SCIENCES↗

Effect of heat treatments on superconducting properties and connectivity in K-doped BaFe2As2

Abstract Fe-based superconductors and in particular K-doped BaFe 2 As 2 (K-Ba122) are materials of interest for possible future high-field applications. However the critical current density ( J c ) in polycrystalline Ba122 is still quite low and connectivity issues are suspected to be responsible. In this work we investigated the properties of high-purity, carefully processed, K-Ba122 samples synthesized with two separate heat treatments at various temperatures between 600 and 825 °C. We performed specific heat characterization and T c -distribution analysis up to 16 T and we compared them with magnetic T c and J c characterizations, and transmission-electron-microscopy (TEM) microstructures. We found no direct correlation between the magnetic T c and J c , whereas the specific heat T c -distributions did provide valuable insights. In fact the best J c -performing sample, heat treated first at 750 °C and then at 600 °C, has the peak of the T c -distributions at the highest temperatures and the least field sensitivity, thus maximizing H c2 . We also observed that the magnetic T c onset was always significantly lower than the specific heat T c : although we partially ascribe the lower magnetization T c to the small grain size (< λ , the penetration depth) of the K-Ba122 phase, this behaviour also implies the presence of some grain-boundary barriers to current flow. Comparing the T c -distribution with J c , our systematic synthesis study reveals that increasing the first heat treatment above 750 °C or the second one above 600 °C significantly compromises the connectivity and suppresses the vortex pinning properties. We conclude that high-purity precursors and clean processing are not yet enough to overcome all J c limitations. However, our study suggests that a higher temperature T c -distribution, a larger H c2 and a better connectivity could be achieved by lowering the second heat treatment temperature below 600 °C thus enhancing, as a consequence, J c .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Control system design and stability analysis for a three phase SiC-based Filter-less grid-connected PV inverter

In this paper, a control system of a filter-less grid-connected SiC inverter is designed. Stability analysis has been researched with a focus on grid disturbance rejection. The analysis shows that the conventional control method with instantaneous grid voltage feedforward (IGVF) will significantly limit the bandwidth or stability margin of a filter-less grid-connected inverter, thus make the inverter sensitive to grid disturbance. Two proposed grid voltage feedforward control methods, which require little additional computation resources, are presented to suppress the grid voltage disturbance. The design methods of control parameters are derived. The effects of the proposed feedforward methods are also compared with that of conventional IGVF. Lastly, the grid-connected experimental results of a three phase SiC based filter-less PV inverter are provided to verify and compare the proposed control methods.

30 DIRECT ENERGY CONVERSION↗

Distribution-Connected PV's Response to Voltage Sags at Transmission-Scale

The ever increasing amount of residential- and commercial-scale distribution-connected PV generation being installed and operated on the U.S.'s electric power system necessitates the use of increased fidelity representative distribution system models for transmission stability studies in order to ensure the continued safe and reliable operation of the grid. This paper describes a distribution model-based analysis that determines the amount of distribution-connected PV that trips off-line for a given voltage sag seen at the distribution circuit's substation. Such sags are what could potentially be experienced over a wide area of an interconnection during a transmission-level line fault. The results of this analysis show that the voltage diversity of the distribution system does cause different amounts of PV generation to be lost for differing severity of voltage sags. The variation of the response is most directly a function of the loading of the distribution system. At low load levels the inversion of the circuit's voltage profile results in considerable differences in the aggregated response of distribution-connected PV Less variation is seen in the response to specific PV deployment scenarios, unless pushed to extremes, and in the total amount of PV penetration attained. A simplified version of the combined CMPLDW and PVD1 models is compared to the results from the model-based analysis. Furthermore, the parameters of the simplified model are tuned to better match the determined response. The resulting tuning parameters do not match the expected physical model of the distribution system and PV systems and thus may indicate that another modeling approach would be warranted.

14 SOLAR ENERGY↗

Exactness of OPF Relaxation on Three-phase Radial Networks with Delta Connections

Simulations have shown that while semi-definite relaxations of AC optimal power flow (AC-OPF) on three-phase radial networks with only wye connections tend to be exact, the presence of delta connections seem to render them inexact. This paper shows that such inexactness originates from the non-uniqueness of relaxation solutions and numerical errors amplified by the non-uniqueness. This finding motivates two algorithms to recover the exact solution of AC-OPF in unbalanced distribution networks featuring both wye and delta connections. In simulations using IEEE 13, 37 and 123-bus systems, the proposed algorithms provide exact optimal solutions up to numerical precision.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SMART Mobility. Connected and Automated Vehicles Capstone Report

The U.S. Department of Energy’s Systems and Modeling for Accelerated Research in Transportation (SMART) Mobility Consortium is a multiyear, multi-laboratory collaborative, managed by the Energy Efficient Mobility Systems Program of the Office of Energy Efficiency and Renewable Energy, Vehicle Technologies Office, dedicated to further understanding the energy implications and opportunities of advanced mobility technologies and services. The first three-year research phase of SMART Mobility occurred from 2017 through 2019 and included five research pillars: Connected and Automated Vehicles, Mobility Decision Science, Multi-Modal Freight, Urban Science, and Advanced Fueling Infrastructure. A sixth research thrust integrated aspects of all five pillars to develop a SMART Mobility Modeling Workflow to evaluate new transportation technologies and services at scale. This report summarizes the work of the Connected and Automated Vehicles (CAVs) Pillar. This Pillar investigated the energy, technology, and usage implications of vehicle connectivity and automation and identified efficient CAV solutions. For information about the other Pillars and about the SMART Mobility Modeling Workflow, please refer to the relevant Pillar’s Capstone Report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Distributed Wind Turbine Controls Series: Part 3-Wind Energy in Grid-Connected Deployments – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In recent years the technical ability and requirement for distributed wind turbines to provide grid support services beyond maximum energy production has increased. Ancillary services leveraged through advance controls of a wind turbine support grid reliability and resilience. One ancillary service that is significant to a grid-connected wind turbine deployment is fault ride through (FRT) in response to the voltage and frequency events in the power system. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, the wind turbine's FRT capabilities to support stable grid operation. We establish that the wind turbine models exceed FRT performance requirements stipulated in IEEE 1547-2018, regarding interconnection and interoperability of distributed energy resources. Utilizing a standalone CART2 (600 kW) wind turbine connected to the NREL's Flatirons Campus grid, we study voltage and frequency FRT utilizing various test cases. One of the test cases under study is a Category III voltage fault defined in IEEE 1547-2018 and derived from CA Rule 21. Some distributed wind turbines were unable to connect to the grid following the Rule 21 enforcement in California. Even if this is not a general requirement elsewhere, the grid codes might evolve in this direction. This study illustrates how a distributed wind turbine can provide some of these FRT services and enable a pathway toward a higher contribution of renewable energy in a distribution grid.

17 WIND ENERGY↗

Energy-Efficient Maneuvering of Connected and Automated Vehicles (CAVs) with Situational Awareness at Intersections (Final Progress Report)

The increased development of Connected and Automated Vehicle (CAV) systems, currently used for safety and driver convenience, presents new opportunities to improve the energy efficiency of vehicles. Southwest Research Institute (SwRI) achieved a 20% energy consumption reduction in a 2017 Toyota Prius Prime plug-in hybrid by using connectivity (V2V, V2I, V2X) as part of the Next Generation Energy Technologies for Connected and Automated on-Road Vehicles (NEXTCAR) program. The energy consumption gains were achieved by a combination of vehicle dynamics and powertrain control algorithms with a focus on SAE L1 and L2 automated vehicles where a human is still responsible for safe operation. SwRI is now involved in NEXTCAR-II, focusing on energy-efficient control tech for SAE Level 4/5 automated vehicles, aiming for a 30% energy reduction compared to stock hybrids. The rise of Mobility as a Service (MaaS) is driving investments in L4 and L5 automated vehicles. A study by the University of Michigan shows these vehicles might increase energy use and emissions by 3-20%. Technology similar to NEXTCAR can enhance energy efficiency in highly automated vehicles, leveraging improved sensing and actuation capabilities. While the NEXTCAR programs targeted energy efficiency improvements for a single vehicle, this program adopts a more expansive approach. It places its focus on understanding and testing the cumulative effects within a region or corridor, aiming to assess how a subset of vehicles equipped with NEXTCAR-style technologies influence the overall energy consumption of all vehicles traveling within that area. Additionally, the program explores infrastructure-based mobility solutions to optimize efficiency, and seeks to understand and quantify public perception and likelihood of technology adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Connected Thermostat Alternatives for Room Air Conditioners and Minisplit Heat Pumps

The availability of smart, connected thermostats has improved climate control, energy efficiency, and grid demand-response programs for central HVAC systems. However, a significant gap exists in addressing integrated control systems for point-source heating and cooling systems such as window air-conditioners (window ACs) and mini-split heat pumps (MSHPs). This report examines the emerging market of third-party connected thermostats tailored for these systems, focusing on their effectiveness, reliability, and potential barriers to adoption.This study evaluates several commercially available products designed for room ACs and MSHPs through a series of laboratory tests. While these infrared-based (IR-based) thermostats offer remote temperature control and scheduling via mobile apps, our findings reveal that none are seamless, with reliability of basic functions being a critical factor. Promising features include integration of indoor air quality metrics and time-of-use pricing, but the latter are not yet available in the U.S. Barriers to broad user acceptance include non-seamless setup processes, challenges in thermostat placement, and unclear product differentiation. There is a pressing need for research and development in enabling MSHPs and central thermostats to coordinate, enhancing energy savings and comfort in retrofit applications. This study underscores the importance of further innovation in connected thermostat technology to address the diverse needs of single-zone HVAC systems and promote efficient energy management in households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Study of an Integration Platform Based on an Adiabatic Active-Layer Waveguide Connection for InP Photonic Device Integration Mirroring That of Heterogeneous Integration on Silicon

In this work, a photonic device integration platform capable of integration of active-passive InP-based photonic devices without the use of material regrowth is introduced. The platform makes use of an adiabatic active-layer waveguide connection (ALWC) to move an optical beam between active and passive devices. The performance of this platform is analyzed using an example made up of four main sections: (1) a fiber coupling section for enabling vertical beam coupling from optical fiber into the photonic chip using a mode-matched surface grating with apodized duty cycles; (2) a transparent waveguide section for realizing passive photonic devices; (3) an adiabatic mode connection structure for moving the optical beam between passive and active device sections; and (4) an active device section for realizing active photonic devices. It is shown that the coupled surface grating, when added with a bottom gold reflector, can achieve a high chip-to-fiber coupling efficiency (CE) of 88.3% at 1550 nm. The adiabatic active-layer mode connection structure has an optical loss of lower than 1% (CE > 99%). The active device section can achieve an optical gain of 20 dB/mm with the use of only 3 quantum wells. The optimized structural parameters of the entire waveguide module are analyzed and discussed.

42 ENGINEERING↗

On Efficient Deployment of Wireless Sensors for Coverage and Connectivity in Constrained 3D Space

Sensor networks have been used in a rapidly increasing number of applications in many fields. This work generalizes a sensor deployment problem to place a minimum set of wireless sensors at candidate locations in constrained 3D space to k-cover a given set of target objects. By exhausting the combinations of discreteness/continuousness constraints on either sensor locations or target objects, we formulate four classes of sensor deployment problems in 3D space: deploy sensors at Discrete/Continuous Locations (D/CL) to cover Discrete/Continuous Targets (D/CT). We begin with the design of an approximate algorithm for DLDT and then reduce DLCT, CLDT, and CLCT to DLDT by discretizing continuous sensor locations or target objects into a set of divisions without sacrificing sensing precision. Furthermore, we consider a connected version of each problem where the deployed sensors must form a connected network, and design an approximation algorithm to minimize the number of deployed sensors with connectivity guarantee. For performance comparison, we design and implement an optimal solution and a genetic algorithm (GA)-based approach. Extensive simulation results show that the proposed deployment algorithms consistently outperform the GA-based heuristic and achieve a close-to-optimal performance in small-scale problem instances and a significantly superior overall performance than the theoretical upper bound.

47 OTHER INSTRUMENTATION↗

Generic characterization of electrical test benches for AC- and HVDC-connected wind power plants

The electrical test and assessment of wind turbines go hand in hand with standards and network connection requirements. In this paper, the generic structure of advanced electrical test benches, including grid emulator or controllable grid interface, wind torque emulator, and device under test, is proposed to harmonize state-of-the-art test sites. On the other hand, modern wind turbines are under development towards new features, concerning grid-forming, black-start, and frequency support capabilities as well as harmonic stability and control interaction considerations, to secure the robustness and stability of renewable-energy-based power systems. Therefore, it is necessary to develop new and revised test standards and methodologies to address the new features of wind turbines. This paper proposes a generic test structure within two main groups, including open-loop and closed-loop tests. The open-loop tests include the IEC 61400-21-1 standard tests as well as the additional proposed test options for the new capabilities of wind turbines, which replicate grid connection compliance tests using open-loop references for the grid emulator. In addition, the closed-loop tests evaluate the device under test as part of a virtual wind power plant and perform real-time simulations considering the grid dynamics. The closed-loop tests concern grid connection topologies consisting of AC and HVDC, as well as different electrical characteristics, including impedance, short-circuit ratio, inertia, and background harmonics. The proposed tests can be implemented using available advanced test benches by adjusting their control systems. The characteristics of a real power system can be emulated by a grid emulator coupled with real-time digital simulator systems through a high-bandwidth power-hardware-in-the-loop interface.

17 WIND ENERGY↗

Electrification: Connecting the Pieces in the Broader View

Presented at the SELECT Annual Meeting on September 26, 2017, this PowerPoint presentation gives an overview of connectivity and automation and how these new technologies will impact society in both known and unknown ways. Electrification challenges and opportunities are also outlined as without electrification, connectivity and automation will just magnify the negative health, climate and economic problems of the current transportation systems. Electrification can provide benefits while mitigating the negative consequences. And with careful connection of all of the pieces from materials up through controls, a sustainable transportation eco-system is attainable.

30 DIRECT ENERGY CONVERSION↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode

This paper explores the dispatchability of grid-forming (GFM) inverters in grid-connected and islanded mode. An innovative concept of dispatching GFM sources (inverters and synchronous generators) is proposed to output the target power by adjusting their droop intercepts. The fundamental principle is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, and thus dispatching the active and reactive power of a GFM inverter can be achieved through dispatching its frequency and voltage. The concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one GFL inverter, and the load in both grid-connected and islanded mode. This pioneering work results in practical guidance for the development of energy management systems for future electric grids with GFM and GFL inverters. The key findings are summarized as follows: 1) The GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power; 2) The dispatch rule for grid-connected and islanded mode is slightly different.

dispatch GFM inverter↗

Effects of Methylphenidate on Resting-State Functional Connectivity of the Mesocorticolimbic Dopamine Pathways in Cocaine Addiction

Cocaine addiction is associated with altered resting-state functional connectivity among regions of the mesocorticolimbic dopamine pathways. Methylphenidate hydrochloride, an indirect dopamine agonist, normalizes task-related regional brain activity and associated behavior in cocaine users; however, the neural systems–level effects of methylphenidate in this population have not yet been described. To use resting-state functional magnetic resonance imaging to examine changes in mesocorticolimbic connectivity with methylphenidate and how connectivity of affected pathways relates to severity of cocaine addiction.