Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Full-Column Greenhouse Gas Sampling Field Campaign Report

The AirCore is a balloon-borne sampler patented and developed at the National Oceanic and Atmospheric Administration (NOAA) Earth System Research Laboratory (ESRL) Global Monitoring Division (GMD) (Tans 2009) that has the capability to provide full-column measurements of greenhouse gases and other trace gas species (Karion et al. 2010). It consists of a long, coated stainless steel tube that is filled with a known trace gas mixture prior to balloon launch (Figure 1). The AirCore is opened at one end prior to balloon launch and, as the balloon ascends, it evacuates to ambient pressure. At 30 km, the balloon is cut away and the AirCore descends via parachute, now capturing an atmospheric air sample or “core” of air from 30 km to the surface due to the pressure gradient between the evacuated AirCore and the environment. Upon landing, the AirCore is closed, preserving the air sample collected in-flight. Because diffusion acts slowly on the AirCore sample in the four hours that it typically takes to launch, retrieve, and analyze the sample, it is possible to capture more than 100 discrete samples in the atmospheric profile collected by the AirCore. Currently, the AirCore is analyzed for carbon dioxide (CO2), methane (CH4), and carbon monoxide (CO) at NOAA/ESRL GMD, but the sample collected can be measured on a variety of other analyzers to obtain full-column profiles of other trace gas species. Unlike routine aircraft measurements, the AirCore provides a low-cost alternative to atmospheric profiling and captures >95% of the atmospheric column. It has a variety of applications, including to full-column greenhouse and trace gas sampling and monitoring, to satellite and remote-sensing instrumentation evaluation, and to tropospheric and stratospheric model evaluation.

Greenhouse gases, Southern Great Plains, balloon-b↗

Tests of isotopic separation efficiency of palladium packed columns

The isotopic effect of palladium has been applied in different ways to separate hydrogen isotopes for many years. At Savannah River Site palladium deposited on kieselguhr (Pd/k) is used in a thermal cycling absorption process (TCAP) to purify tritium for over ten years. The need to design columns for different throughputs and the desire to advance the performance of TCAP created the need to evaluate different column designs and packing materials for their separation efficiency. In this work, columns with variations in length, diameter and metal foam presence were tested using an isotope displacement method. A simple computer model was also developed to calculate the number of theoretical separation stages based on the test results. The effects of column diameter, metal foam presence and gas flow rate were identified. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Simulation of In Situ Bioremediation of Chromium (VI) Using Consortium Cultures and Column Studies - 19357

Chromium contaminated soil and ground water has become a serious problem caused by the rapid expansion of industries, leading to direct or indirect discharge of Cr(VI). The conventional methods that include pump and treat result into toxic byproducts and residual. Cr(VI) reducing bacteria in the contrary have been envisioned as an economically and ecologically friendly method to treat contaminated sites. Biological Cr(VI) reduction processes include biotransformation, biosorption which involve detoxification/ removal of hazardous substances and bioaccumulation. A continuous flow column system for Cr(VI) reduction was investigated in three different treatments and the control, using dried sludge and soil from target site. Cultures identified using effluent samples in the 16S rRNA sequencing showed a prominent of Exiguobacterium aestuarii species as it was identified from all column systems. Other cultures that showed 100% query cover included; Enterobacter aerogenes, Enterobacter kobei and Pseudomonas aeruginosa. More than 90% of Cr(VI) reduction was observed in all columns over a 60 day period at 40 mgL{sup -1}. Cr(VI) was reduced from 38.12 mgL{sup -1} to 0.39 mgL{sup -1}. A more unstable profile was observed at 60 mgL{sup -1} over 60 days. Subsequently, there was near complete reduction from System 1 and 3 of 1.152 mgL{sup -1} and 1.215 mgL{sup -1} Cr(VI) concentration, respectively. A Cr(VI) reduction profile along the column proved to be uniform at assumed quasi-steady state from the influent to the effluent for both 40 and 60 mgL{sup -1} Cr(VI) concentration. Biological remediation strategies for Cr(VI) contaminated soil and groundwater is an emerging field that has been proposed to successfully treat Cr(VI) contaminated sites using Cr(VI) reduction species of bacteria. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fundamental Study of Migration Behavior of Cesium under the Unsaturated Condition through One-dimensional Column Simulating Soil around the Disposal Site - 20262

Using a packed column simulating unsaturated soil around the disposal site, flow experiments of cesium ions were conducted in order to examine the difference of retardation effect between saturated and unsaturated conditions. The column was packed with silica sand particles of 350 μm in diameter. In this study, it was confirmed that the X-ray CT images of the column showed that the water saturation was mostly uniform within the column under unsaturated conditions. The values of water saturation in the flow experiments of Cs ions were in a range from 0.85 to 0.93. The retardation coefficients(Rd) were estimated by applying the one-dimensional advection-dispersion equation to the experimental results. The comparison of the Rd-values estimated experimentally and theoretically showed that the experimental value was estimated to be larger than the theoretical value. This means that the theoretical value evaluated through a conventional method would bring the conservative value as an apparent retardation coefficient, at least when the flow direction is from top to bottom as shown in this study. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automated metal-free multiple-column nanoLC for improved phosphopeptide analysis sensitivity and throughput

We report on the development and characterization of an automated metal-free nanoscale multiple-capillary system for reversed-phase liquid chromatography-mass spectrometry analysis of phosphopeptides. The system incorporates a capillary column (50 um i.d. × 30 cm, packed with 5 um C18 particles) coupled on-line to a solid phase extraction column (150 um i.d. × 4 cm, packed with 5 um C18 particles). Electrospray ionization tips are constructed on the packed capillary column to couple the reversed-phase liquid chromatographic separation to a linear ion trap tandem mass spectrometer.

59 BASIC BIOLOGICAL SCIENCES↗

Plant-Scale Concentration Column Designs for SHINE Target Solution Utilizing AG 1 Anion Exchange Resin

Argonne is assisting SHINE Medical Technologies (SHINE) in their efforts to develop SHINE, an accelerator-driven process that will utilize a uranyl-sulfate solution for the production of fission product Mo-99. An integral part of the process is the development of a column for the separation and recovery of Mo-99, followed by a concentration column to reduce the product volume from 15-25 L to <1 L. Argonne has collected data from batch studies and breakthrough column experiments to utilize the VERSE (Versatile Reaction Separation) simulation program (Purdue University) to design plant-scale product recovery and concentration processes.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Reconfigurable Magnetic Liquid Building Blocks for Constructing Artificial Spinal Column Tissues

All-liquid molding can be used to transform a liquid into free-form solid constructs, while maintaining internal fluidity. Traditional biological scaffolds, such as cured pre-gels, are normally processed in solid state, sacrificing flowability and permeability. However, it is essential to maintain the fluidity of the scaffold to truly mimic the complexity and heterogeneity of natural human tissues. Here, this work molds an aqueous biomaterial ink into liquid building blocks with rigid shapes while preserving internal fluidity. The molded ink blocks for bone-like vertebrae and cartilaginous-intervertebral-disc shapes, are magnetically manipulated to assemble into hierarchical structures as a scaffold for subsequent spinal column tissue growth. It is also possible to join separate ink blocks by interfacial coalescence, different from bridging solid blocks by interfacial fixation. Generally, aqueous biomaterial inks are molded into shapes with high fidelity by the interfacial jamming of alginate surfactants. The molded liquid blocks can be reconfigured using induced magnetic dipoles, that dictated the magnetic assembly behavior of liquid blocks. The implanted spinal column tissue exhibits a biocompatibility based on in vitro seeding and in vivo cultivating results, showing potential physiological function such as bending of the spinal column.

60 APPLIED LIFE SCIENCES↗

Fully automated four-column capillary LC-MS system for maximizing throughput in proteomic analyses

We describe a 4-column, high-pressure capillary liquid chromatography (LC) system for robust, high-throughput LC-MS(/MS) analyses. This system performs multiple LC separations in parallel, but staggers each of them such that the data-rich region of each separation is sampled sequentially. By allowing nearly continuous data acquisition, this design maximizes the use of the mass spectrometer. Each analytical column is connected to a corresponding ESI emitter in order to avoid the use of post-column switching and associated dead volume issues. Encoding translation stages are employed to sequentially position the emitters at the MS inlet. The high reproducibility of this system is demonstrated using consecutive analyses of global tryptic digest of the microbe Shewanella oneidensis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

3D printed structures for optimized carbon capture technology in packed bed columns

The use of 3D printed structured packing for the optimization of aqueous-amine based carbon capture in packed absorption columns is examined in this paper. An experimental testing system has been set up, and initial comparisons were made between metal, plastic, and 3D printed 16-inch packing elements and between three 8-inch 3D printed elements of different densities. Pressure drop measurements were obtained at various air flowrates under dry conditions. Measurements were also taken for a wet system by adding water at six different liquid flowrates. In each case, theoretical calculations for pressure drop were performed based on a model presented in the literature. It was found that, for the 16-inch dry column, the model slightly overpredicts the pressure drop. The model provides an accurate prediction for the dry 8-inch experimental data, especially for the two least dense packing elements. For the wet system, the model overpredicts the pressure drop, likely due to modeling deficiencies when the column reaches its loading limit. Furthermore, these results provide sufficient confidence to move forward with testing and process intensification of the CO 2 capture process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-current medium-pressure RF discharge with electron photoemission in the electrode sheath and penetration of the sheath electrons into the discharge column

A model is developed for simulating a low-current moderate-pressure RF discharge with allowance for such characteristic discharge properties as the existence of two sheaths near both electrodes throughout the RF field period; the formation of an electron cloud at the sheath boundary that periodically fills the sheath and leaves it, depending on the phase of the applied RF voltage; the production by the sheath electrons of metastable gas particles that interact with the cloud electrons during subsequent field periods, followed by the excitation of metastable states to the emitting levels; the formation of a sheath in a low-current RF discharge due to the overlap of the secondary electron avalanches triggered by electron photoemission from the electrode surface; and the conditions under which the sheath electrons penetrate into the positive column and accumulate there, which makes, thereby making a low-current RF discharge similar to a non-self-sustained discharge. The parameters of the sheath in a low-current RF discharge are determined by the conditions under which the electron photoemission current from the electrode surface in the sheath is self-sustaining and, like the parameters of the positive discharge column, depend on the sort of gas, the gas pressure, the frequency of the applied RF field, and the interelectrode distance. The results of calculating the parameters of the sheath and column of a low-current RF discharge for nitrogen and helium at different pressures, as well as for different field frequencies and interelectrode distances, are presented and are compared with the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Repetitive Regeneration of Media #1 in a Dynamic Column Extraction using Brine #1

This data is from a regeneration study from a dynamic column extraction experiment where we ran a solution of REE's through a column of media #1 then stripped the REE's off the media using 2M HNO3 solution. We then re-equilibrated the media and repeated the process of running a REE solution through the column and stripping the REE's off the media and comparing the two runs.

15 GEOTHERMAL ENERGY↗

Reference Model 6 Full Scale Geometry (RM6: Oscillating Water Column)

Contains the Reference Model 6 (RM6) full scale geometry files of the Oscillating Water Column, developed by the Reference Model Project (RMP). These full scale geometry files are saved as SolidWorks assembly, IGS, and STEP files, and require a CAD program to view. This data was generated upon completion of the project on September 30, 2014. The Reference Model Project (RMP), sponsored by the U.S. Department of Energy (DOE), was a partnered effort to develop open-source MHK point designs as reference models (RMs) to benchmark MHK technology performance and costs, and an open-source methodology for design and analysis of MHK technologies, including models for estimating their capital costs, operational costs, and levelized costs of energy. The point designs also served as open-source test articles for university researchers and commercial technology developers. The RMP project team, led by Sandia National Laboratories (SNL), included a partnership between DOE, three national laboratories, including the National Renewable Energy Laboratory (NREL), Pacific Northwest National Laboratory (PNNL), and Oak Ridge National Laboratory (ORNL), the Applied Research Laboratory of Penn State University, and Re Vision Consulting. Reference Model 6 (RM6) is a Backward Bent Duct Buoy (BBDB), which is a type of oscillating water column wave energy converter. First proposed by Masuda, the BBDB design is a floating Oscillating Water Column (OWC) device that consists of an air chamber, an L-shaped duct, bow and stern buoyancy modules, and a power take-off (PTO) composed of a Wells air turbine and a generator. This L- shaped device opens to the ocean downstream from the wave propagation direction. Power is produced by the motion of the wave, which causes the ambient pressure in the air chamber to vary thereby forcing air to flow through the Wells turbine. The reference wave energy resource for RM6 was developed from site information collected near Eureka, in Humboldt County, California.

16 TIDAL AND WAVE POWER↗

BNF C-band Scanning ARM Precipitation Radar 2nd Generation (CSAPR-2) Extracted Radar Columns and In-Situ Sensors (RadCLss)

Corrected Moments in Antenna Coordinates (CMAC) calculates quantitative precipitation estimates (QPE) from empirical relationships based on equivalent radar reflectivity factor, specific differ- ential phase, and specific attenuation. To evaluate these empirical relationships, the Extracted Radar Columns and In-Situ Sensors (RADclss) product was developed. Utilizing Py-ART, RAD- clss extracts CMAC radar columns above various ARM and partner locations. These columns are then spatiotemporally synced with in-situ observations at the surface utilizing the Atmospheric data Community Toolkit (ACT; Theisen et al. 2025), allowing direct comparison of radar parameters with rain gauges and laser disdrometers for further investigation.

bankhead↗

The column strength of aluminum alloy 75S-T extruded shapes

Because the tensile strength and tensile yield strength of alloy 75S-T are appreciably higher than those of the materials used in the tests leading to the use of the straight-line column curve, it appeared advisable to establish the curve of column strength by test rather than by extrapolation of relations determined empirically in the earlier tests. The object of this investigation was to determine the curve of column strength for extruded aluminum alloy 75S-T. In addition to three extruded shapes, a rolled-and-drawn round rod was included. Specimens of various lengths covering the range of effective slenderness ratios up to about 100 were tested.

COLUMNS, ALUMINUM-ALLOY - ALCOA 75ST - STRENGTH↗

Understanding Measured Water Rotational Temperatures and Column Densities in the Very Innermost Coma of Comet 73P/Schwassmann-Wachmann 3 B

Direct sublimation of a comet nucleus surface is usually considered to be the main source of gas in the coma of a comet. However, evidence from a number of comets including the recent spectacular images of Comet 103P/Hartley 2 by the EPOXI mission indicates that the nucleus alone may not be responsible for all, or possibly at times even most, of the total amount of gas seen in the coma. Indeed, the sublimation of icy grains, which have been injected into the coma, appears to constitute an important source. We use the fully-kinetic Direct Simulation Monte Carlo model of Tenishev et al. to reproduce the measurements of column density and rotational temperature of water in Comet 73P-B/Schwassmann-Wachmann 3 obtained with a very high spatial resolution of approx. 30 km using IRCS/Subaru in May 2006. For gas released solely from the cometary nucleus at a heliocentric distance of 1 AU, modeled rotational temperatures start at 110 K close to the surface and decrease to only several tens of degrees by 10-20 nucleus radii. However, the measured decay of both rotational temperature and column density with distance from the nucleus is much slower than predicted by this simple model. The addition of a substantial (distributed) source of gas from icy grains in the model slows the decay in rotational temperature and provides a more gradual drop in column density profiles. Together with a contribution of rotational heating of water molecules by electrons, the combined effects allow a much better match to the IRCS/Subaru observations. From the spatial distributions of water abundance and temperature measured in 73P/SW3-B, we have identified and quantified multiple mechanisms of release. The application of this tool to other comets may permit such studies over a range of heliocentric and geocentric distances.

comet↗

Small Column Ion Exchange Design and Safety Strategy

Small Column Ion Exchange (SCIX) is a transformational technology originally developed by the Department of Energy (DOE) Environmental Management (EM-30) office and is now being deployed at the Savannah River Site (SRS) to significantly increase overall salt processing capacity and accelerate the Liquid Waste System life-cycle. The process combines strontium and actinide removal using Monosodium Titanate (MST), Rotary Microfiltration, and cesium removal using Crystalline Silicotitanate (CST, specifically UOP IONSIV{reg_sign}IE-911 ion exchanger) to create a low level waste stream to be disposed in grout and a high level waste stream to be vitrified. The process also includes preparation of the streams for disposal, e.g., grinding of the loaded CST material. These waste processing components are technically mature and flowsheet integration studies are being performed including glass formulations studies, application specific thermal modeling, and mixing studies. The deployment program includes design and fabrication of the Rotary Microfilter (RMF) assembly, ion-exchange columns (IXCs), and grinder module, utilizing an integrated system safety design approach. The design concept is to install the process inside an existing waste tank, Tank 41H. The process consists of a feed pump with a set of four RMFs, two IXCs, a media grinder, three Submersible Mixer Pumps (SMPs), and all supporting infrastructure including media receipt and preparation facilities. The design addresses MST mixing to achieve the required strontium and actinide removal and to prevent future retrieval problems. CST achieves very high cesium loadings (up to 1,100 curies per gallon (Ci/gal) bed volume). The design addresses the hazards associated with this material including heat management (in column and in-tank), as detailed in the thermal modeling. The CST must be size reduced for compatibility with downstream processes. The design addresses material transport into and out of the grinder and includes provisions for equipment maintenance including remote handling. The design includes a robust set of nuclear safety controls compliant with DOE Standard (STD)-1189, Integration of Safety into the Design Process. The controls cover explosions, spills, boiling, aerosolization, and criticality. Natural Phenomena Hazards (NPH) including seismic event, tornado/high wind, and wildland fire are considered. In addition, the SCIX process equipment was evaluated for impact to existing facility safety equipment including the waste tank itself. SCIX is an innovative program which leverages DOE's technology development capabilities to provide a basis for a successful field deployment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Production of Molybdenum-99 by (n, ) activation and direct separation of Technetium-99m without column generator fabrication: A viable strategy for enhanced availability of technetium-99m

Fission-produced 99Mo (F 99Mo) is traditionally used for fabrication of 99Mo/99mTc adsorption-type column generators. In this paper, several emerging strategies that are being pursued or have been suggested to overcome the continuing shortages of F 99Mo are discussed. To provide an alternative source of 99Mo, the principal focus of this analysis is a detailed discussion of the advantages and strategies for enhanced production of low-specific-activity 99Mo (LSA 99Mo) by direct activation of molybdenum targets in nuclear reactors. In order to enhance the availability of 99Mo, development of an increased network of reactors for production of LSA 99Mo is described, as well as utilization of currently unused reactors. The time spent in manufacturing of 99Mo/99mTc column generators is responsible for the loss of more than 50% of F99Mo produced. Hence, the authors propose a paradigm shift in the use of 99Mo by recovering clinical-grade 99mTc from 99Mo solution as an alternative to use of 99Mo/99mTc column generators, thereby avoiding substantial decreased availability of 99Mo from radioactive decay. Implementation of the suggested strategies would be expected to increase availability of 99mTc to the clinical user community by several folds. Additional important advantages of the use of LSA 99Mo include precluding the need for fission product waste management and phasing out the need for high- and low-enriched uranium as target materials for medical radioisotope production.

column generator↗

Salt Processing Through Ion Exchange at the Savannah River Site Selection of Exchange Media and Column Configuration - 9198

The Department of Energy (DOE) has developed, modeled, and tested several different ion exchange media and column designs for cesium removal. One elutable resin and one non-elutable resin were considered for this salt processing application. Deployment of non-elutable Crystalline Silicotitanate and elutable Resorcinol Formaldehyde in several different column configurations were assessed in a formal Systems Engineering Evaluation (SEE). Salt solutions were selected that would allow a grouping of non-compliant tanks to be closed. Tests were run with the elutable resin to determine compatibility with the resin configuration required for an in-tank ion exchange system. Models were run to estimate the ion exchange cycles required with the two resins in several column configurations. Material balance calculations were performed to estimate the impact on the High Level Waste (HLW) system at the Savannah River Site (SRS). Conceptual process diagrams were used to support the hazard analysis. Data from the hazard analysis was used to determine the relative impact on safety. This report will discuss the technical inputs, SEE methods, results and path forward to complete the technical maturation of ion exchange.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗