Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coding standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

qSIEVE: Efficient qLDPC Memory via Systolic Movement in Atom Arrays

As quantum machines have scaled up in their number of qubits, significant research has turned towards increasing their fidelity with quantum error correction codes. Although promising results have been shown with the surface code, which only requires near-neighbor connections between qubits, the high qubit overhead of such local codes promises to be problematic. Consequently, recent work has explored non-local quantum LDPC (qLDPC) codes, which have good asymptotic encoding rates. Despite theoretical progress, hardware implementations of these codes have been a longstanding challenge. At the experimental level, demonstrations of movement based communication on atom arrays suggest this is a powerful new primitive to achieve non-local connectivity. Leveraging this, we present a protocol for implementing non-local qLDPC codes in hardware. Our protocol, qSIEVE, is a co-design of such codes with movement in atom arrays. qSIEVE defines a restricted family of qLDPC codes that can be implemented efficiently with systolic movement. We then quantify the utility of qSIEVE in the context of a complete fault tolerant architecture. We compare the cost of implementing benchmark programs in a standard, surface code only architecture and a mixed architecture where data is stored in qLDPC memory with qSIEVE and loaded to surface codes for computation.

Quantum error correction↗

Building Energy Codes Program: National Benefits Assessment (1992-2040)

Building energy codes and standards set minimum requirements for energy-efficient design and construction for new and renovated buildings, assuring reductions in energy use and greenhouse gas emissions over the life of buildings. DOE, through the Building Energy Codes Program, supports the improvement of energy efficiency in buildings. BECP periodically assesses the impacts of its activities by estimating historical and projected energy savings, consumer savings, and avoided emissions. The Pacific Northwest National Laboratory conducted the codes benefits assessment in support of the BECP. Underlying the assessment is a series of calculations that estimate and compare energy savings under two scenarios: "with BECP" and "without BECP." The analysis covers the years 1992-2040 and includes comparing the nominal energy savings (assuming 100 percent adoption and compliance) attributable to different code versions, determining the applicable floor space (both residential and commercial) subject to the code, and estimating the final energy savings by adjusting nominal energy savings for the applicable floor space according to the estimated actual adoption and compliance levels. The resulting estimates of energy consumption for each scenario are compared, and the difference equals the impact of BECP activities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Production and characterization of a nitrogen-implanted Fe standard to calibrate PIGE measurements

Three calibration standard was produced by ion implantation of nitrogen in samples of Armco iron (99.7% iron). The samples was irradiated with nitrogen ion beams at several different energies (between 4 keV and 40 keV), and the ion doses were adjusted to obtain an uniform depth profile, using simulations with SRIM code. Two standards, one thick and other a foil (1.62mg/cm{sup 2}), was irradiated at same time with total nominal dose of 6.6×10{sup −16} atoms/cm{sup 2} distributed in a region of 100 nm in depth, with an average concentration of 9.0% nitrogen in iron. The third sample uses the same profile, but with a small dose, 1.1×10{sup −16} atoms/cm{sup 2} and average concentration of 1.5% nitrogen. The characterization of the implanted samples was done using RBS and NRA techniques to quantification of nitrogen.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the Path to SunShot. Emerging Issues and Challenges in Integrating Solar with the Distribution System

This report analyzes distribution-integration challenges, solutions, and research needs in the context of distributed generation from PV (DGPV) deployment to date and the much higher levels of deployment expected with achievement of the U.S. Department of Energy's SunShot targets. Recent analyses have improved estimates of the DGPV hosting capacities of distribution systems. This report uses these results to statistically estimate the minimum DGPV hosting capacity for the contiguous United States using traditional inverters of approximately 170 GW without distribution system modifications. This hosting capacity roughly doubles if advanced inverters are used to manage local voltage and additional minor, low-cost changes could further increase these levels substantially. Key to achieving these deployment levels at minimum cost is siting DGPV based on local hosting capacities, suggesting opportunities for regulatory, incentive, and interconnection innovation. Already, pre-computed hosting capacity is beginning to expedite DGPV interconnection requests and installations in select regions; however, realizing SunShot-scale deployment will require further improvements to DGPV interconnection processes, standards and codes, and compensation mechanisms so they embrace the contributions of DGPV to system-wide operations. SunShot-scale DGPV deployment will also require unprecedented coordination of the distribution and transmission systems. This includes harnessing DGPV's ability to relieve congestion and reduce system losses by generating closer to loads; minimizing system operating costs and reserve deployments through improved DGPV visibility; developing communication and control architectures that incorporate DGPV into system operations; providing frequency response, transient stability, and synthesized inertia with DGPV in the event of large-scale system disturbances; and potentially managing reactive power requirements due to large-scale deployment of advanced inverter functions. Finally, additional local and system-level value could be provided by integrating DGPV with energy storage and 'virtual storage,' which exploits improved management of electric vehicle charging, building energy systems, and other large loads. Together, continued innovation across this rich distribution landscape can enable the very-high deployment levels envisioned by SunShot.

14 SOLAR ENERGY↗

Three-Dimensional Event Localization in Bulk Scintillator Crystals Using Optical Coded Apertures

Scintillator-based detectors are among the most commonly used methods for detecting ionizing radiation. Scintillators provide a reliable, cost-effective, and simple way to make large-volume detectors. Furthermore, localizing the position of the interactions in three dimensions within the crystals is useful to a wide array of fields. The most straightforward way of doing this is to pair the crystal with a position-sensitive phototransducer (PT). This allows for measurement of the shape of the light spot at the PT plane. Using this information, various methods exist to localize the gamma-ray interaction in the crystal; however, the position resolution worsens the farther the event occurs from the PT plane. To improve on the localization ability, this work uses an optical coded-aperture shadow mask between the crystal and the PT. In addition, the recorded detector response is used in reconstructing the event over the entire depth of the crystal, and the “sharpest” reconstructed image gives an event's depth. The lateral position is given from the standard coded-aperture image reconstruction. Lastly, experimental results obtained by emulating a 26-mm-thick crystal using a thin 1-mm-thick NaI(Tl) crystal and different amounts of light pipe between the crystal and the PT plane achieved ~ 1 to 2-mm resolution in all three dimensions throughout most of the 26-mm-thick crystal.

36 MATERIALS SCIENCE↗

High-Performance Ducts in Hot-Dry Climates

Duct thermal losses and air leakage have long been recognized as prime culprits in the degradation of heating, ventilating, and air-conditioning (HVAC) system efficiency. Both the U.S. Department of Energy’s Zero Energy Ready Home program and California’s proposed 2016 Title 24 Residential Energy Efficiency Standards require that ducts be installed within conditioned space or that other measures be taken to provide similar improvements in delivery effectiveness (DE). Pacific Gas & Electric Company commissioned a study to evaluate ducts in conditioned space and high-performance attics (HPAs) in support of the proposed codes and standards enhancements included in California’s 2016 Title 24 Residential Energy Efficiency Standards. The goal was to work with a select group of builders to design and install high-performance duct (HPD) systems, such as ducts in conditioned space (DCS), in one or more of their homes and to obtain test data to verify the improvement in DE compared to standard practice. Davis Energy Group (DEG) helped select the builders and led a team that provided information about HPD strategies to them. DEG also observed the construction process, completed testing, and collected cost data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RELIABILITY BASED DESIGN OF FIXED FOUNDATION WIND TURBINES

Recent analysis of offshore wind turbine foundations using both applicable API and IEC standards show that the total load demand from wind and waves is greatest in wave driven storms. Further, analysis of overturning moment loads (OTM) reveal that impact forces exerted by breaking waves are the largest contributor to OTM in big storms at wind speeds above the operating range of 25 m/s. Currently, no codes or standards for offshore wind power generators have been adopted by the Bureau of Ocean Energy Management Regulation and Enforcement (BOEMRE) for use on the Outer Continental Shelf (OCS). Current design methods based on allowable stress design (ASD) incorporate the uncertainty in the variation of loads transferred to the foundation and geotechnical capacity of the soil and rock to support the loads is incorporated into a factor of safety. Sources of uncertainty include spatial and temporal variation of engineering properties, reliability of property measurements applicability and sufficiency of sampling and testing methods, modeling errors, and variability of estimated load predictions. In ASD these sources of variability are generally given qualitative rather than quantitative consideration. The IEC 61400‐3 design standard for offshore wind turbines is based on ASD methods. Load and resistance factor design (LRFD) methods are being increasingly used in the design of structures. Uncertainties such as those listed above can be included quantitatively into the LRFD process. In LRFD load factors and resistance factors are statistically based. This type of analysis recognizes that there is always some probability of failure and enables the probability of failure to be quantified. This paper presents an integrated approach consisting of field observations and numerical simulation to establish the distribution of loads from breaking waves to support the LRFD of fixed offshore foundations.

17 WIND ENERGY↗

HyRAM (Hydrogen Risk Assessment Models) v. 1.0

HyRAM is a software toolkit for conducting quantitative risk assessment (QRA) and consequence modeling for hydrogen infrastructure and transportation systems. HyRAM contains validated, simplified hydrogen behavior models, a standardized QRA approach, and engineering models and generic data relevant to hydrogen installations. HyRAM 1.0 was developed by Sandia National Laboratories for the U. S. Department of Energy to increase access to technical data about hydrogen and to enable the use of that data to support development and revision of national and international codes and standards with risk assessment and consequence modeling. The HyRAM toolkit integrates analytical and probabilistic models for quantifying accident scenarios, predicting physical effects, and characterizing the impact of hydrogen hazards (including thermal effects from jet fires and overpressure effects from deflagrations in confined areas) on people and structures. HyRAM incorporates generic probabilities for equipment failures for nine types of components, and probabilistic models for the impact of heat flux on humans and structures, with computationally and experimentally validated analytical first order models of hydrogen release and flame physics. Version 1 can be used to quantify the risk and consequences associated with gaseous hydrogen releases from user-defined hydrogen installations.

Groth, Katrina M.↗

Methodology for assessing the safety of Hydrogen Systems: HyRAM 1.0 technical reference manual

The HyRAM software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen infrastructure and transportation systems. HyRAM is designed to facilitate the use of state-of-the-art science and engineering models to conduct robust, repeatable assessments of hydrogen safety, hazards, and risk. HyRAM is envisioned as a unifying platform combining validated, analytical models of hydrogen behavior, a standardized, transparent QRA approach, and engineering models and generic data for hydrogen installations. HyRAM is being developed at Sandia National Laboratories for the U. S. Department of Energy to increase access to technical data about hydrogen safety and to enable the use of that data to support development and revision of national and international codes and standards. This document provides a description of the methodology and models contained in the HyRAM version 1.0. HyRAM 1.0 includes generic probabilities for hydrogen equipment failures, probabilistic models for the impact of heat flux on humans and structures, and computationally and experimentally validated analytical and first order models of hydrogen release and flame physics. HyRAM 1.0 integrates deterministic and probabilistic models for quantifying accident scenarios, predicting physical effects, and characterizing hydrogen hazards (thermal effects from jet fires, overpressure effects from deflagrations), and assessing impact on people and structures. HyRAM is a prototype software in active development and thus the models and data may change. This report will be updated at appropriate developmental intervals.

08 HYDROGEN↗

Updating Small Generator Interconnection Procedures for New Market Conditions

Federal and state regulators are faced with the challenge of keeping interconnection procedures updated against a backdrop of evolving technology, new codes and standards, and considerably transformed market conditions. This report is intended to educate policymakers and stakeholders on beneficial reforms that will keep interconnection processes efficient and cost-effective while maintaining a safe and reliable power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Explicit Integration of Extremely Stiff Reaction Networks: Quasi-Steady-State Methods

A preceding paper [1] demonstrated that explicit asymptotic methods generally work much better for extremely stiff reaction networks than has previously been shown in the literature. There we showed that for systems well removed from equilibrium explicit asymptotic methods can rival standard implicit codes in speed and accuracy for solving extremely stiff differential equations. In this paper we continue the investigation of systems well removed from equilibrium by examining quasi-steady-state (QSS) methods as an alternative to asymptotic methods. We show that for systems well removed from equilibrium, QSS methods also can compete with, or even exceed, standard implicit methods, even for extremely stiff networks, and in many cases give somewhat better integration speed than for asymptotic methods. As for asymptotic methods, we will find that QSS methods give correct results, but with non-competitive integration speed as equilibrium is approached. Thus, we shall find that both asymptotic and QSS methods must be supplemented with partial equilibrium methods as equilibrium is approached to remain competitive with implicit methods.

Guidry, Mike W↗

Final Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

In 2017, New York State Energy Research and Development Authority (NYSERDA) developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code. Since2017, NYSERDA has continued to develop the 2018 edition, as part of the efforts to achieve a statewide Net Zero Energy Code by 2028. To support this effort, Pacific Northwest National Laboratory (PNNL)conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code 2018 compared to ANSI/ASHRAE/IES1 Standard 90.1-2013. Specifically, PNNL collaborated with New Buildings Institute (NBI), and developed energy-efficiency measures (EEMs) from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the ongoing NYStretch-Energy code development process. PNNL analyzed these measures using whole building energy simulation for selected prototype commercial and multifamily buildings representing buildings in New York State.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Final Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

In 2017, New York State Energy Research and Development Authority (NYSERDA) developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code. Since 2017, NYSERDA has continued to develop the 2018 edition, as part of the efforts to achieve a statewide Net Zero Energy Code by 2028. To support this effort, Pacific Northwest National Laboratory (PNNL) conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code 2018 compared to ANSI/ASHRAE/IES1 Standard 90.1-2013. Specifically, PNNL collaborated with New Buildings Institute (NBI), and developed energy-efficiency measures (EEMs) from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the ongoing NYStretch-Energy code development process. PNNL analyzed these measures using whole building energy simulation for selected prototype commercial and multifamily buildings representing buildings in New York State. This report describes the analysis methodology, explains detailed specifications of the EEMs, and summarizes the results of individual EEMs and EEM bundles by building type and climate zone. As shown in Figure ES.1, significant energy saving could be achieved by adopting the NYStretch-Energy Code 2018.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lighting: Development, Adoption, and Compliance Guide

The guide provides information for anyone dealing with a lighting energy code or standard. It provides background and development information to help readers understand the basis for requirements and their intent. The guide also provides detailed explanations of the major types of requirements such that users can more effectively design to meet compliance while applying the most flexibility possible.

Luminaires, IECC, code compliance, high-intensity ↗

Quantifying Occupant Health and Productivity for Deep Retrofits: Beyond Traditional IEQ Studies

As energy-efficiency standards for both new construction and existing building renovations become more stringent, further reductions become less tractable and more expensive. With increasing interest and rising investment in healthy built environments, integrating energy efficiency with improved occupant experience (i.e., health, comfort, and work performance) offers a new path to drive deep energy retrofits. However, the difficulty in quantifying and verifying health and productivity gains from building upgrades leads to lower valuation of human benefits in practice. Building codes and standards have progressive energy targets but often give minimum requirements to occupant health for factors such as ventilation and thermal comfort. State and federal laws in the United States that govern the energy service performance contract (ESPC) have no clear and consistent guidance on quantifying non-energy benefits and incorporating them into a formal cost-effectiveness analysis. This paper presents a methodology to measure a building’s potential performance improvement regarding occupant health based on existing evidence correlating IEQ to occupant outcomes. Health improvement measures are integrated with a building energy model to identify and measure the impact of holistic improvement strategies. The net present value of these measures is determined based on the investment costs required to attain those improvements, energy savings, and personnel gains. We will discuss results from one pilot building, which showed nearly $50 per square foot 20-year net present value using the integrated approach.

Keene, Kevin M.↗

Plant Reload Optimization (prlo)

The PRLO framework is built on a modular and extensible architecture that tightly couples advanced evolutionary optimization algorithms with nuclear fuel depletion solvers (i.e., nuclear physics neutronics code). It supports exploring complex, high-dimensional design spaces constrained by user-specified operational, safety, and economic constraints. Objectives such as minimizing fresh fuel enrichment, flattening radial and axial power distributions, and maximizing discharge burnup are evaluated. PRLO’s equilibrium cycle optimization capability enables the identification of core configurations that maintain fuel cycle sustainability over extended planning horizons. Its integration with the RAVEN platform facilitates optimization of loading patterns or fuel shuffling schemes across multiple cycles. The interface with SIMULATE, a licensed industry-standard nodal code developed by Studsvik, ensures accurate neutronic and thermal-hydraulic feedback for reactor core design. PRLO’s automated workflow engine supports iterative design refinement, enabling utilities to streamline core design processes and meet evolving performance and regulatory targets.

Kim, Junyung [Idaho National Laboratory] (00090005↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗