Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “code compliance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

An Affordable Test Approach for Lunar Fission Surface Power Systems

The objective of the Fission Surface Power System (FSPS) development and qualification program is to assure that the components, subsystems and complete power system satisfy all of their mission requirements with a sufficiently high level of confidence. To accomplish this objective, the FSPS program will conduct nuclear and non-nuclear development and testing in compliance with standard NASA practice for all of the reactor, power conversion, and system integration hardware and software items. The anticipated program includes extensive performance and environmental testing of components throughout their predicted operational conditions and possible fault conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimentation in Exploring Photovoltaic Inverter Dynamics Under Different Irradiance Levels Through a Data-Driven Approach

As conventional direct connections of synchronous generators are being phased out, inverter-based resources (IBRs) with grid support functions are increasingly being integrated into power systems. This transition requires the development of accurate dynamic models for IBRs to predict how power systems will adapt to varying levels of IBRs penetration, establish grid code requirements, and ensure compliance. Here, this study introduces an active probing signal-based data-driven modeling technique to accurately derive the dynamics model of a smart photovoltaic inverter operating in Volt-Watt and Freq-Watt modes, in compliance with the IEEE 1547–2018 standard. The paper focuses on investigating how the dynamics of the PV inverter model respond to fluctuations in solar irradiance, utilizing real-time digital simulator experimentation. The experimental analysis demonstrates that the amplitude of dynamics fluctuates with changes in irradiance across both operational modes and confirms the active power’s dependence on irradiance levels. Furthermore, the nature of inverter dynamics varies distinctly between the different modes of activation. Critically, our findings indicate that dynamic models require DC-gain adjustments to accommodate contrasting irradiance levels, highlighting a negative gradient linear relationship between the DC-gain of each model and the irradiance.

14 SOLAR ENERGY↗

Advanced Grid Simulator for Multi-Megawatt Power Converter Testing and Certification

Grid integration testing of inverter-coupled renewable energy technologies is an essential step in the qualification of renewable energy and energy storage systems to ensure the stability of the power system. New types of devices must be thoroughly tested and validated for compliance with relevant grid codes and interconnection requirements. For this purpose, highly specialized custom-made testing equipment is needed to emulate various types of realistic grid conditions that are required by certification bodies or for research purposes. For testing multi-megawatt converters, a high power grid simulator capable of creating controlled grid conditions and meeting both power quality and dynamic characteristics is needed. This paper describes the new grid simulator concept based on ABB's medium voltage ACS6000 drive technology that utilizes advanced modulation and control techniques to create an unique testing platform for various multi-megawatt power converter systems. Its performance is demonstrated utilizing the test results obtained during commissioning activities at the National Renewable Energy Laboratory in Colorado, USA.

17 WIND ENERGY↗

High-Performance Molecular Dynamics Simulation for Biological and Materials Sciences: Challenges of Performance Portability, Dallas, TX, November 2018.

Highly-optimized parallel molecular dynamics programs have allowed researchers to achieve ground-breaking results in biological and materials sciences. This type of performance has come at the expense of portability: a significant effort is required for performance optimization on each new architecture. Using a metric that emphasizes speedup, we assess key accelerating programming components of four different best-performing molecular dynamics programs - GROMACS, NAMD, LAMMPS and CP2K-- each having a particular scope of application, for contribution to performance and for portability. We use builds with and without these components, tested on HPC systems. We also analyze the code-bases to determine compliance with portability recommendations. We find that for all four programs, the contributions of the non-portable components to speed are essential to the programs' performances; without them we see a reduction in time-to-solution of a magnitude that is insufferable to domain scientists. This characterizes the performance efficiency that must be approached for good performance portability on a programmatic level, suggesting solutions to this difficult problem, which should come from developers, industry and funding institutions, and possibly new research in programming languages.

Computer Science↗

SU-E-P-05: Electronic Brachytherapy: A Physics Perspective On Field Implementation

Purpose: We want to summarize our experience implementing a successful program of electronic brachytherapy at several dermatology clinics with the help of a cloud based software to help us define the key program parameters and capture physics QA aspects. Optimally developed software helps the physicist in peer review and qualify the physical parameters. Methods: Using the XOFT™ Axxent™ electronic brachytherapy system in conjunction with a cloud-based software, a process was setup to capture and record treatments. It was implemented initially at about 10 sites in California. For dosimetric purposes, the software facilitated storage of the physics parameters of surface applicators used in treatment and other source calibration parameters. In addition, the patient prescription, pathology and other setup considerations were input by radiation oncologist and the therapist. This facilitated physics planning of the treatment parameters and also independent check of the dwell time. From 2013–2014, nearly1500 such calculation were completed by a group of physicists. A total of 800 patients with multiple lesions have been treated successfully during this period. The treatment log files have been uploaded and documented in the software which facilitated physics peer review of treatments per the standards in place by AAPM and ACR. Results: The program model was implemented successfully at multiple sites. The cloud based software allowed for proper peer review and compliance of the program at 10 clinical sites. Dosimtery was done on 800 patients and executed in a timely fashion to suit the clinical needs. Accumulated physics data in the software from the clinics allows for robust analysis and future development. Conclusion: Electronic brachytherapy implementation experience from a quality assurance perspective was greatly enhanced by using a cloud based software. The comprehensive database will pave the way for future developments to yield superior physics outcomes.

07 ISOTOPE AND RADIATION SOURCES↗

TU-AB-204-02: Device Adverse Events and Compliance

The responsibilities of the Food and Drug Administration (FDA) have increased since the inception of the Food and Drugs Act in 1906. Medical devices first came under comprehensive regulation with the passage of the 1938 Food, Drug, and Cosmetic Act. In 1971 FDA also took on the responsibility for consumer protection against unnecessary exposure to radiation-emitting devices for home and occupational use. However it was not until 1976, under the Medical Device Regulation Act, that the FDA was responsible for the safety and effectiveness of medical devices. This session will be presented by the Division of Radiological Health (DRH) and the Division of Imaging, Diagnostics, and Software Reliability (DIDSR) from the Center for Devices and Radiological Health (CDRH) at the FDA. The symposium will discuss on how we protect and promote public health with a focus on medical physics applications organized into four areas: pre-market device review, post-market surveillance, device compliance, current regulatory research efforts and partnerships with other organizations. The pre-market session will summarize the pathways FDA uses to regulate the investigational use and commercialization of diagnostic imaging and radiation therapy medical devices in the US, highlighting resources available to assist investigators and manufacturers. The post-market session will explain the post-market surveillance and compliance activities FDA performs to monitor the safety and effectiveness of devices on the market. The third session will describe research efforts that support the regulatory mission of the Agency. An overview of our regulatory research portfolio to advance our understanding of medical physics and imaging technologies and approaches to their evaluation will be discussed. Lastly, mechanisms that FDA uses to seek public input and promote collaborations with professional, government, and international organizations, such as AAPM, International Electrotechnical Commission (IEC), Image Gently, and the Quantitative Imaging Biomarkers Alliance (QIBA) among others, to fulfill FDA’s mission will be discussed. Learning Objectives: Understand FDA’s pre-market and post-market review processes for medical devices Understand FDA’s current regulatory research activities in the areas of medical physics and imaging products Understand how being involved with AAPM and other organizations can also help to promote innovative, safe and effective medical devices J. Delfino, nothing to disclose.

60 APPLIED LIFE SCIENCES↗

Recertification Project Plan (Rev. 5)

The Waste Isolation Pilot Plant (WIPP) Recertification Project was established to meet the WIPP Land Withdrawal Act (LWA) (Public Law 102-579, as amended by Public Law 104-201) (102nd U.S. Congress, 1992) requirement to demonstrate continued compliance with U.S. Environmental Protection Agency (EPA) disposal regulations. This plan sets the overall direction for a complex and interdependent set of tasks that is repeated at five-year intervals and culminates in EPA certification that the WIPP facility demonstrates continued compliance with Title 40 Code of Federal Regulations (CFR) Part 191, "Environmental Radiation Protection Standards for the Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes," pursuant to LWA sections 8(d)(1) and 8(f).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DOE 2012 Occupational Radiation Exposure October 2013

The U.S. Department of Energy (DOE) Office of Analysis within the Office of Health, Safety and Security (HSS) publishes the annual DOE Occupational Radiation Exposure Report to provide an overview of the status of radiation protection practices at DOE (including the National Nuclear Security Administration [NNSA]). The DOE 2012 Occupational Radiation Exposure Report provides an evaluation of DOE-wide performance regarding compliance with Title 10, Code of Federal Regulations (C.F.R.), Part 835, Occupational Radiation Protection dose limits and as low as reasonably achievable (ALARA) process requirements. In addition, the report provides data to DOE organizations responsible for developing policies for protection of individuals from the adverse health effects of radiation. The report provides a summary and an analysis of occupational radiation exposure information from the monitoring of individuals involved in DOE activities. Over the past 5-year period, the occupational radiation exposure information is analyzed in terms of aggregate data, dose to individuals, and dose by site. As an indicator of the overall amount of radiation dose received during the conduct of operations at DOE, the report includes information on collective total effective dose (TED). The TED is comprised of the effective dose (ED) from external sources, which includes neutron and photon radiation, and the internal committed effective dose (CED), which results from the intake of radioactive material into the body. The collective ED from photon exposure decreased by 23% between 2011 and 2012, while the neutron dose increased by 5%. The internal dose components of the collective TED decreased by 7%. Over the past 5-year period, 99.99% of the individuals receiving measurable TED have received doses below the 2 roentgen equivalent in man (rems) (20 millisievert [mSv]) TED administrative control level (ACL), which is well below the DOE regulatory limit of 5 rems (50 mSv) TED annually. The occupational radiation exposure records show that in 2012, DOE facilities continued to comply with DOE dose limits and ACLs and worked to minimize exposure to individuals. The DOE collective TED decreased 17.1% from 2011 to 2012. The collective TED decreased at three of the five sites with the largest collective TED. u Idaho Site – Collective dose reductions were achieved as a result of continuing improvements at the Advanced Mixed Waste Treatment Project (AMWTP) through the planning of drum movements that reduced the number of times a container is handled; placement of waste containers that created highradiation areas in a centralized location; and increased worker awareness of high-dose rate areas. In addition, Idaho had the largest decrease in the total number of workers with measurable TED (1,143 fewer workers). u Hanford Site (Hanford) – An overall reduction of decontamination and decommissioning (D&D) activities at the Plutonium Finishing Plant (PFP) and Transuranic (TRU) retrieval activities resulted in collective dose reductions. u Savannah River Site (SRS) – Reductions were achieved through ALARA initiatives employed site wide. The Solid Waste Management Facility used extended specialty tools, cameras and lead shield walls to facilitate removal of drums. These tools and techniques reduce exposure time through improved efficiency, increase distance from the source of radiation by remote monitoring, shield the workers to lower the dose rate, and reduce the potential for contamination and release of material through repacking of waste. Overall, from 2011 to 2012, there was a 19% decrease in the number of workers with measurable dose. Furthermore, due to a slight decrease in both the DOE workforce (7%) and monitored workers (10%), the ratio of workers with measurable doses to monitored workers decreased to 13%. Another primary indicator of the level of radiation exposure covered in this report is the average measurable dose, which normalizes the collective dose over the population of workers who actually received a measurable dose. The average measurable TED increased by 3% from 2011 to 2012. Additional analyses show that the dose distribution in 2012 was similar to the distribution in 2011. In 2012, 13% of the monitored workers received a measurable TED and the average measurable TED, 0.069 rem, was less than 2% of the DOE limit. From 2011 to 2012, the collective TED and the number of individuals with measurable TED decreased 17.1% and 19%, respectively. These decreases were mainly due to an overall reduction of D&D activities at the PFP and TRU retrieval activities at Hanford; a 78% decrease in the number of targeted waste drums that were processed at the Idaho Site’s Accelerated Retrieval Project (ARP) from 5,566 drums in 2011 to a total of 1,211 drums processed in 2012; and ALARA initiatives employed site wide at SRS. In addition, the decreases were the result of decreased American Recovery and Reinvestment Act (ARRA) activities and continuing D&D, particularly at the DOE sites that comprise the majority of DOE collective dose. Over the past 5 years, the size of the monitored workforce has remained at a fairly stable level (within 12%), while the collective dose has varied up to 37%. No reported doses exceeded the DOE occupational limit of 5 rems TED in 2012 and no reported doses exceeded the DOE ACL of 2 rems TED.

61 RADIATION PROTECTION AND DOSIMETRY↗

DOE 2013 occupational radiation exposure

The Office of Analysis within the U.S. Department of Energy (DOE) Office of Environment, Health, Safety and Security (EHSS) publishes the annual DOE Occupational Radiation Exposure Report to provide an overview of the status of radiation protection practices at DOE (including the National Nuclear Security Administration [NNSA]). The DOE 2013 Occupational Radiation Exposure Report provides an evaluation of DOE-wide performance regarding compliance with Title 10, Code of Federal Regulations (C.F.R.), Part 835, Occupational Radiation Protection dose limits and as low as reasonably achievable (ALARA) process requirements. In addition, the report provides data to DOE organizations responsible for developing policies for protection of individuals from the adverse health effects of radiation. The report provides a summary and an analysis of occupational radiation exposure information from the monitoring of individuals involved in DOE activities. Over the past five-year period, the occupational radiation exposure information has been analyzed in terms of aggregate data, dose to individuals, and dose by site.

Source record↗

DOE 2012 occupational radiation exposure

The U.S. Department of Energy (DOE) Office of Analysis within the Office of Health, Safety and Security (HSS) publishes the annual DOE Occupational Radiation Exposure Report to provide an overview of the status of radiation protection practices at DOE (including the National Nuclear Security Administration [NNSA]). The DOE 2012 Occupational Radiation Exposure Report provides an evaluation of DOE-wide performance regarding compliance with Title 10, Code of Federal Regulations (C.F.R.), Part 835, Occupational Radiation Protection dose limits and as low as reasonably achievable (ALARA) process requirements. In addition, the report provides data to DOE organizations responsible for developing policies for protection of individuals from the adverse health effects of radiation. The report provides a summary and an analysis of occupational radiation exposure information from the monitoring of individuals involved in DOE activities. Over the past 5-year period, the occupational radiation exposure information is analyzed in terms of aggregate data, dose to individuals, and dose by site.

Source record↗

DOE 2011 occupational radiation exposure

The U.S. Department of Energy (DOE) Office of Analysis within the Office of Health, Safety and Security (HSS) publishes the annual DOE Occupational Radiation Exposure Report to provide an overview of the status of radiation protection practices at DOE (including the National Nuclear Security Administration [NNSA]). The DOE 2011 Occupational Radiation Exposure Report provides an evaluation of DOE-wide performance regarding compliance with Title 10, Code of Federal Regulations (C.F.R.), Part 835, Occupational Radiation Protection dose limits and as low as reasonably achievable (ALARA) process requirements. In addition, the report provides data to DOE organizations responsible for developing policies for protection of individuals from the adverse health effects of radiation. The report provides a summary and an analysis of occupational radiation exposure information from the monitoring of individuals involved in DOE activities. The occupational radiation exposure information is analyzed in terms of aggregate data, dose to individuals, and dose by site over the past five years.

Source record↗

Best Practices for NPT Transit Matching

Transit matching is the process for relating or matching reports of shipments and receipts submitted to the International Atomic Energy Agency (IAEA). Transit matching is a component used by the IAEA in drawing safeguards conclusions and performing investigative analysis. Transit matching is part of IAEA safeguards activities and the State evaluation process, and it is included in the annual Safeguards Implementation Report (SIR). Annually, the IAEA currently receives reports of ~900,000 nuclear material transactions, of which ~500,000 are for domestic and foreign transfers. Of these the IAEA software can automatically match (i.e., machine match) about 95% of the domestic transfers and 25% of the foreign transfers. Given the increasing demands upon IAEA resources, it is highly desirable for the machine-matching process to match as many transfers as possible. Researchers at Oak Ridge National Laboratory (ORNL) have conducted an investigation funded by the National Nuclear Security Administration through the Next Generation Safeguards Initiative to identify opportunities to strengthen IAEA transit matching. Successful matching, and more specifically machine matching, is contingent on quality data from the reporting States. In February 2016, ORNL hosted representatives from three States, the IAEA, and Euratom to share results from past studies and to discuss the processes, policies, and procedures associated with State reporting for transit matching. Drawing on each entity's experience and knowledge, ORNL developed a best practices document to be shared with the international safeguards community to strengthen transit matching. This paper shares the recommendations that resulted from this strategic meeting and the next steps being taken to strengthen transit matching.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Biofuels Campus for Accelerated Development

The award was intended for Biofuels Center of North Carolina to create a functioning Biofuels Company Accelerator, for various companies to work toward establishing biofuels production viability in North Carolina and the southeast. To achieve this outcome, DOE funds were used to refurbish eight existing laboratories for compliance with safety and code regulations. These labs were located in the headquarters building and were originally constructed in 1969 and used extensively until 1994. Completely idled, the laboratories required significant updating and modification to make them functional. According to the Final Progress Report, the project funds were used to renovate the laboratories. Janice Ford was the Technical Project Officer who managed this Congressionally Directed Project. The project’s period of performance was from 11/01/2010 through 10/31/2011. Biofuels Center of North Carolina dissolved 12/10/2013.

09 BIOMASS FUELS↗

Nevada National Security Site Radiological Control Manual

This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO). (Activities conducted under the purview of the U.S. Department of Energy, Office of Environmental Management Nevada[(EM Nevada] may require additional approval authorities as described in the EM Nevada Prime Contractor’s implementation plan.) Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations (CFR) Part 835, “Occupational Radiation Protection.” This manual represents policies, guidelines, and best practices for implementing the DOE/NV/03624--0082, “Nevada National Security Site Radiation Protection Program,” (NNSS RPP) according to the requirements of 10 CFR 835.

61 RADIATION PROTECTION AND DOSIMETRY↗

National Cost-effectiveness of ANSI/ASHRAE/IES Standard 90.1-2016

The purpose of this analysis is to examine the cost-effectiveness of the 2016 edition of ANSI/ASHRAE/IES Standard 90.1 (ASHRAE 2016). Standard 90.1 is developed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard Standing Project Committee (SSPC) 90.1. It is the model energy standard for commercial and multi-family residential buildings over three floors (42 USC 6833). PNNL analyzed the cost-effectiveness of changes in Standard 90.1 from 90.1-2013 to 90.1-2016, as applied in commercial buildings across the United States. During the development of new editions of Standard 90.1, the cost-effectiveness of individual changes (addenda) is often calculated to support the deliberations of ASHRAE Standard Standing Project Committee (SSPC) 90.1. The ASHRAE process, however, does not include analysis of the cost-effectiveness of the entire package of addenda from one edition of the standard to the next, which is of particular interest to adopting State and local governments. Providing States with an analysis of cost-effectiveness may encourage more rapid adoption of newer editions of energy codes based on Standard 90.1. This information may also inform the development of future editions of Standard 90.1. To establish the cost-effectiveness of Standard 90.1-2016, three main tasks were addressed: (1) Identification of building elements impacted by the updated standard; (2) Allocation of associated installation, maintenance, and replacement costs; and (3) Cost-effectiveness analysis of required changes In addition to installation, maintenance, and replacement costs, energy cost differences were needed to determine cost-effectiveness. The energy costs for each edition of Standard 90.1 were determined previously under the development of Standard 90.1-2016, as described below. The current analysis builds on the previous PNNL analysis (as outlined in Section 5.2) of the energy use and energy cost saving impacts of Standard 90.1-2016 compared to previous editions. The overall energy savings analysis of Standard 90.1 utilized a suite of 16 prototype EnergyPlus building models in 15 climate locations representing all eight U.S. climate zones. Detailed methodology and overall energy saving results from Standard 90.1-2016 are documented in the DOE technical report titled Energy Savings Analysis: ANSI/ASHRAE/IES Standard 90.1-2016 (DOE. 2018b).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BENCHMARKING ORTEC ISOTOPIC MEASUREMENTS AND CALCULATIONS

This report represents a description of compiled benchmark tests conducted to probe and to demonstrate the extensive utility of the Ortec ISOTOPIC {gamma}-ray analysis computer program. The ISOTOPIC program performs analyses of {gamma}-ray spectra applied to specific acquisition configurations in order to apply finite-geometry correction factors and sample-matrix-container photon absorption correction factors. The analysis program provides an extensive set of preset acquisition configurations to which the user can add relevant parameters in order to build the geometry and absorption correction factors that the program determines from calculus and from nuclear g-ray absorption and scatter data. The Analytical Development Section field nuclear measurement group of the Savannah River National Laboratory uses the Ortec ISOTOPIC analysis program extensively for analyses of solid waste and process holdup applied to passive {gamma}-ray acquisitions. Frequently the results of these {gamma}-ray acquisitions and analyses are to determine compliance with facility criticality safety guidelines. Another use of results is to designate 55-gallon drum solid waste as qualified TRU waste3 or as low-level waste. Other examples of the application of the ISOTOPIC analysis technique to passive {gamma}-ray acquisitions include analyses of standard waste box items and unique solid waste configurations. In many passive {gamma}-ray acquisition circumstances the container and sample have sufficient density that the calculated energy-dependent transmission correction factors have intrinsic uncertainties in the range 15%-100%. This is frequently the case when assaying 55-gallon drums of solid waste with masses of up to 400 kg and when assaying solid waste in extensive unique containers. Often an accurate assay of the transuranic content of these containers is not required, but rather a good defensible designation as >100 nCi/g (TRU waste) or <100 nCi/g (low level solid waste) is required. In these cases the ISOTOPIC analysis program is especially valuable because it allows a rapid, defensible, reproducible analysis of radioactive content without tedious and repetitive experimental measurement of {gamma}-ray transmission through the sample and container at multiple photon energies. The ISOTOPIC analysis technique is also especially valuable in facility holdup measurements where the acquisition configuration does not fit the accepted generalized geometries where detector efficiencies have been solved exactly with good calculus. Generally in facility passive {gamma}-ray holdup measurements the acquisition geometry is only approximately reproducible, and the sample (object) is an extensive glovebox or HEPA filter component. In these cases accuracy of analyses is rarely possible, however demonstrating fissile Pu and U content within criticality safety guidelines yields valuable operating information. Demonstrating such content can be performed with broad assumptions and within broad factors (e.g. 2-8) of conservatism. The ISOTOPIC analysis program yields rapid defensible analyses of content within acceptable uncertainty and within acceptable conservatism without extensive repetitive experimental measurements. In addition to transmission correction determinations based on the mass and composition of objects, the ISOTOPIC program performs finite geometry corrections based on object shape and dimensions. These geometry corrections are based upon finite element summation to approximate exact closed form calculus. In this report we provide several benchmark comparisons to the same technique provided by the Canberra In Situ Object Counting System (ISOCS) and to the finite thickness calculations described by Russo in reference 10. This report describes the benchmark comparisons we have performed to demonstrate and to document that the ISOTOPIC analysis program yields the results we claim to our customers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Duct Leakage Modeling in EnergyPlus and Analysis of Energy Savings from Implementing SAV with InCITeTM

This project addressed two significant deficiencies in air-handling systems for large commercial building: duct leakage and duct static pressure reset. Both constitute significant energy reduction opportunities for these buildings. The overall project goal is to bridge the gaps in current duct performance modeling capabilities, and to expand our understanding of air-handling system performance in California large commercial buildings. The purpose of this project is to provide technical support for the implementation of a duct leakage modeling capability in EnergyPlus, to demonstrate the capabilities of the new model, and to carry out analyses of field measurements intended to demonstrate the energy saving potential of the SAV with InCITeTM duct static pressure reset (SPR) technology. A new duct leakage model has been successfully implemented in EnergyPlus, which will enable simulation users to assess the impacts of leakage on whole-building energy use and operation in a coupled manner. This feature also provides a foundation to support code change proposals and compliance analyses related to Title 24 where duct leakage is an issue. Our example simulations continue to show that leaky ducts substantially increase fan power: 10percent upstream and 10percent downstream leakage increases supply fan power 30percent on average compared to a tight duct system (2.5percent upstream and 2.5percent downstream leakage). Much of this increase is related to the upstream leakage rather than to the downstream leakage. This does not mean, however, that downstream leakage is unimportant. Our simulations also demonstrate that ceiling heat transfer is a significant effect that needs to be included when assessing the impacts of duct leakage in large commercial buildings. This is not particularly surprising, given that ?ceiling regain? issues have already been included in residential analyses as long as a decade ago (e.g., ASHRAE Standard 152); mainstream simulation programs that are used for large commercial building energy analyses have not had this capability until now. Our analyses of data that we collected during our 2005 tests of the SAV with InCITeTM duct static pressure reset technology show that this technology can substantially reduce fan power (in this case, by about 25 to 30percent). Tempering this assessment, however, is that cooling and heating coil loads were observed to increase or decrease significantly depending on the time window used. Their impact on cooling and heating plant power needs to be addressed in future studies; without translating the coil loads to plant equipment energy use, it is not possible to judge the net impact of this SPR technology on whole-building energy use. If all of the loads had decreased, such a step would not be as necessary.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measured moisture performance of sealed and insulated attics with permeable insulation in california homes

This study performed detailed thermal and moisture measurements in two homes in Fresno and Clovis, California with sealed attics insulated with glass fiber insulation to determine moisture performance in inland California climates. Data were recorded once every minute for more than a year in each home to allow detailed observation of time-varying moisture and thermal conditions. Moisture measurements were taken at multiple locations in each attic and included wood moisture, surface condensation and surface relative humidity. The results showed that there are strong solar-driven diurnal cycles in attic wood and air moisture content, as well as longer-term seasonal and annual variations. Mold growth was obdserved on the North roof deck in one of the two homes even in this sunny dry climate with attics built in compliance with California building codes that specifically address sealed and insulated attics with vapor-permeable insulation. We investigated moisture stratification in the attic and found that, although there is stratification during sunny daytime hours, this was not when wood moisture content, surface humidity or surface condensation are high. Therefore, other moisture transport mechanisms are acting to increase moisture levels near the roof peak. Finally, our measurements also showed that the attic with the highest measured moisture levels did not have any mold growth, while mold was visually observed in the attic whose measurements indicted little or no concern, indicating that the state-of-the-art in moisture measurement and mold growth prediction in building assemblies may be insufficient.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗