Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “chemical analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Partial Least Squares and Neural Networks for Quantitative Calibration of Laser-induced Breakdown Spectroscopy (LIBs) of Geologic Samples

The ChemCam instrument [1] on the Mars Science Laboratory (MSL) rover will be used to obtain the chemical composition of surface targets within 7 m of the rover using Laser Induced Breakdown Spectroscopy (LIBS). ChemCam analyzes atomic emission spectra (240-800 nm) from a plasma created by a pulsed Nd:KGW 1067 nm laser. The LIBS spectra can be used in a semiquantitative way to rapidly classify targets (e.g., basalt, andesite, carbonate, sulfate, etc.) and in a quantitative way to estimate their major and minor element chemical compositions. Quantitative chemical analysis from LIBS spectra is complicated by a number of factors, including chemical matrix effects [2]. Recent work has shown promising results using multivariate techniques such as partial least squares (PLS) regression and artificial neural networks (ANN) to predict elemental abundances in samples [e.g. 2-6]. To develop, refine, and evaluate analysis schemes for LIBS spectra of geologic materials, we collected spectra of a diverse set of well-characterized natural geologic samples and are comparing the predictive abilities of PLS, cascade correlation ANN (CC-ANN) and multilayer perceptron ANN (MLP-ANN) analysis procedures.

Anderson, R. B.↗

Multiplex gas chromatography

The principles of the multiplex gas chromatography (GC) technique, which is a possible candidate for chemical analysis of planetary atmospheres, are discussed. Particular attention is given to the chemical modulators developed by present investigators for multiplex GC, namely, the thermal-desorption, thermal-decomposition, and catalytic modulators, as well as to mechanical modulators. The basic technique of multiplex GC using chemical modulators and a mechanical modulator is demonstrated. It is shown that, with the chemical modulators, only one gas stream consisting of the carrier in combination with the components is being analyzed, resulting in a simplified instrument that requires relatively few consumables. The mechanical modulator demonstrated a direct application of multiplex GC for the analysis of gases in atmosphere of Titan at very low pressures.

Valentin, Jose R.↗

SEM Characterization of Extinguished Grains from Plasma-Ignited M30 Charges

M30 propellant grains that had been ignited in interrupted closed bomb experiments were characterize by scanning electron microscopy (SEM). Previous chemical analysis of extinguished grains had given no indications of plasma-propellant chemical interactions that could explain the increased burning rates that had been previously observed in full-pressure closed bomb experiments. (This does not mean that there is no unique chemistry occurring with plasma ignition. It may occur very early in the ignition event and then become obscured by the burning chemistry.) In this work, SEM was used to look at grain morphologies to determine if there were increases in the surface areas of the plasma-ignited grains which would contribute to the apparent increase in the burning rate. Charges were made using 30 propellant grains (approximately 32 grams) stacked in two tiers and in two concentric circles around a plastic straw. Each grain was notched so that, when the grains were expelled from the bomb during extinguishment, it could be determined in which tier and which circle each grain was originally packed. Charges were ignited in a closed bomb by either a nickel wire/Mylar-capillary plasma or black powder. The bomb contained a blowout disk that ruptured when the pressure reached 35 MPa, and the propellant was vented into a collection chamber packed with polyurethane foam. SEM analysis of the grains fired with a conventional black powder igniter showed no signs of unusual burning characteristics. The surfaces seemed to be evenly burned on the exteriors of the grains and in the perforations. Grains that had been subjected to plasma ignition, however, had pits, gouges, chasms, and cracks in the surfaces. The sides of the grains closest to the plasma had the greatest amount of damage, but even surfaces facing the outer wall of the bomb had small pits. The perforations contained gouges and abnormally burned regions (wormholes) that extended into the web. The SEM photos indicated that a grain from the top tier, which was farther away from the plasma ignition source, sustained more plasma-induced damage to the perforations and the web than did the grains on the bottom tier.

Kinkennon, A.↗

Multiplex gas chromatography: an alternative concept for gas chromatographic analysis of planetary atmospheres

Gas chromatography (GC) is a powerful technique for analyzing gaseous mixtures. Applied to the earth's atmosphere, GC can be used to determine the permanent gases--such as carbon dioxide, nitrogen, and oxygen--and to analyze organic pollutants in air. The U.S. National Aeronautics and Space Administration (NASA) has used GC in spacecraft missions to Mars (the Viking Biology Gas Exchange Experiment [GEX] and the Viking Gas Chromatograph-Mass Spectrometer [GC-MS]) and to Venus (the Pioneer Venus Gas Chromatograph [PVGC] on board the Pioneer Venus sounder probe) for determining the atmospheric constituents of these two planets. Even though conventional GC was very useful in the Viking and Pioneer missions, spacecraft constraints and limitations intrinsic to the technique prevented the collection of more samples. With the Venus probe, for instance, each measurement took a relatively long time to complete (10 min), and successive samples could not be introduced until the previous samples had left the column. Therefore, while the probe descended through the Venusian atmosphere, only three samples were acquired at widely separated altitudes. With the Viking mission, the sampling rate was not a serious problem because samples were acquired over a period of one year. However, the detection limit was a major disadvantage. The GC-MS could not detect simple hydrocarbons and simple alcohols below 0.1 ppm, and the GEX could not detect them below 1 ppm. For more complex molecules, the detection limits were at the parts-per-billion level for both instruments. Finally, in both the Viking and Pioneer missions, the relatively slow rate of data acquisition limited the number of analyses, and consequently, the amount of information returned. Similar constraints are expected in future NASA missions. For instance, gas chromatographic instrumentation is being developed to collect and analyze organic gases and aerosols in the atmosphere of Titan (one of Saturn's satellites). The Titan-Cassini entry probe, which is being jointly planned by NASA and the European Space Agency (ESA), might be launched as early as 1994. As in the Pioneer mission, limited time--perhaps only 3-4 h--will be available for the completion of all analyses while the probe descends through the atmosphere. A conventional GC or GC-MS system would be able to analyze no more than two aerosol and two gas samples during the probe's descent. Conventional GC also is limited by the sensitivity of the detector and by the sample volume. For the Titan mission, the sensitivity problems will be worse because the atmospheric pressure at the time of instrument deployment is expected to be < 3 torr. Consequently, the sample volume might not be large enough to satisfy the detector sensitivity requirements. Because of such limitations, alternative GC analysis techniques have been investigated for future NASA missions. Multiplex gas chromatography has been investigated as a possible candidate for chemical analysis within a spacecraft or other restricted environment, and chemical modulators have been developed and used when needed with this technique to reduce the size and weight of the instrumentation. Also, several new multiplex techniques have been developed for use in specific applications.

NASA Center ARC↗

A fundamental approach to adhesion: Synthesis, surface analysis, thermodynamics and mechanics

Several techniques were used to study pretreated Ti 6-4 surfaces including scanning electron microscopy (SEM), electron spectroscopy of chemical analysis (ESCA), and, reflectance visible spectroscopy. Each pretreatment type gave a characteristic surface morphology as seen by SEM. Elemental analysis of the Ti 6-4 surfaces was done using ESCA. Trace residual contaminants from particular chemical pretreatments were identified readily. Results indicate that reflectance visible spectroscopy using indicator dyes placed on Ti 6-4 surfaces appears to be a feasible approach to establish surface acidity. Differences in surface acidity were observed using bromthymol blue on Ti 6-4 surfaces pretreated by two different methods.

Beck, B.↗

The use of an ion-beam source to alter the surface morphology of biological implant materials

An electron bombardment, ion thruster was used as a neutralized-ion beam sputtering source to texture the surfaces of biological implant materials. Scanning electron microscopy was used to determine surface morphology changes of all materials after ion-texturing. Electron spectroscopy for chemical analysis was used to determine the effects of ion texturing on the surface chemical composition of some polymers. Liquid contact angle data were obtained for ion textured and untextured polymer samples. Results of tensile and fatigue tests of ion-textured metal alloys are presented. Preliminary data of tissue response to ion textured surfaces of some metals, polytetrafluoroethylene, alumina, and segmented polyurethane were obtained.

Weigand, A. J.↗

Liquid oxygen LOX compatibility evaluations of aluminum lithium (Al-Li) alloys: Investigation of the Alcoa 2090 and MMC weldalite 049 alloys

The behavior of liquid oxygen (LOX) compatibility of aluminum lithium (Al-Li) alloys is investigated. Alloy systems of Alcoa 2090, vintages 1 to 3, and of Martin Marietta Corporation (MMC) Weldalite 049 were evaluated for their behavior related to the LOX compatibility employing liquid oxygen impact test conditions under ambient pressures and up to 1000 psi. The developments of these aluminum lithium alloys are of critical and significant interest because of their lower densities and higher specific strengths and improved mechanical properties at cryogenic temperatures. Of the different LOX impact tests carried out at the Marshall Space Flight Center (MSFC), it is seen that in certain test conditions at higher pressures, not all Al-Li alloys are LOX compatible. In case of any reactivity, it appears that lithium makes the material more sensitive at grain boundaries due to microstructural inhomogeneities and associated precipitate free zones (PFZ). The objectives were to identify and rationalize the microstructural mechanisms that could be relaxed to LOX compatibility behavior of the alloy system in consideration. The LOX compatibility behavior of Al-Li 2090 and Weldalite 049 is analyzed in detail using microstructural characterization techniques with light optical metallography, scanning electron microscopy (SEM), electron microprobe analysis, and surface studies using secondary ion mass spectrometry (SIMS), electron spectroscopy in chemical analysis (ESCA) and Auger electron spectroscopy (AES). Differences in the behavior of these aluminum lithium alloys are assessed and related to their chemistry, heat treatment conditions, and microstructural effects.

Diwan, Ravinder M.↗

Eudicot Nutshells: Cell-Wall Composition and Biofuel Feedstock Potential

Nutshells are the recalcitrant and membranous layers that encompass and provide protection to the seed of a fruit. Rich in lignin, these are often waste products of the food industry and are a potential energy-dense feedstock for biorefineries to convert to biofuels. Here, assessing their potential requires an understanding of the relative amounts of cellulose, hemicelluloses, and lignin, the composition and structure of the lignin, and a saccharifiability assessment, all provided here. In the context of understanding the general character of phylogenetically diverse eudicot species, we provide a chemical analysis of the lignin in the shells of commonly eaten nuts and detail the chemical composition of their lignins. Particularly striking observations include the >40% levels of Klason lignins in the nutshells from macadamia, pecan, and Brazil nut and lignin compositions ranging from <1% syringyl (S) in macadamia to 77% S in pistachio and essentially 0% p-hydroxyphenyl (H) in mango to as high as 7.5% H in walnut. Novel units in the lignin polymer (such as the hydroxystilbenes recently discovered in macaúba and coconut shell lignins) were not evident in any of the samples, but the series provided such a range of compositions that it aided more detailed assignment.

NMR↗

Identification of Suitable Vacuum Gas Oils as Plasticizers Using HT-GC × GC-HRMS

Vacuum gas oils (VGOs) have long been heralded as effective plasticizers due to their high boiling-points and lubricating properties. One of these VGOs, HyVac Oil 93050, is a paraffinic plasticizer that is currently utilized in polymer–plasticizer explosive formulations, while this oil effectively increases the elasticity and decreases the sensitivity for current formulations. We seek to identify alternative VGOs with similar density, viscosity, molecular composition, and impurities for future formulations. In this study, 18 VGOs, including HyVac Oil 93050, were initially evaluated for their density and viscosity. The oils were then ranked based on physical characteristics and analyzed for molecular composition using high-temperature comprehensive two-dimensional gas chromatography with high-resolution time-of-flight mass spectrometry (HT-GC × GC-HRMS). Further, the HT-GC × GC-HRMS chromatograms of the top 10 most similar VGOs to HyVac Oil 93050, according to density, were compared utilizing the Pearson correlation coefficient. Three of the oils with densities similar to those of HyVac Oil 93050 had a Pearson correlation within the lot-to-lot variation of HyVac Oil 93050. For the top 3 candidates, Pearson correlation was then utilized as a feature selection technique to discover significant chemical differences. Positive chemical ionization (PCI) and negative chemical ionization (NCI) HT-GC × GC-HRMS chromatograms were also evaluated and aided in the discovery and identification of several key compounds including additives that acted as stabilizers for the VGOs. After this further chemical analysis, two of the original 17 potential VGOs were determined to be physically and chemically similar to HyVac Oil 93050.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The use of an ion-beam source to alter the surface morphology of biological implant materials

An electron-bombardment ion-thruster was used as a neutralized-ion-beam sputtering source to texture the surfaces of biological implant materials. The materials investigated included 316 stainless steel; titanium-6% aluminum, 4% vanadium; cobalt-20% chromium, 15% tungsten; cobalt-35% nickel, 20% chromium, 10% molybdenum; polytetrafluoroethylene; polyoxymethylene; silicone and polyurethane copolymer; 32%-carbon-impregnated polyolefin; segmented polyurethane; silicone rubber; and alumina. Scanning electron microscopy was used to determine surface morphology changes of all materials after ion-texturing. Electron spectroscopy for chemical analysis was used to determine the effects of ion-texturing on the surface chemical composition of some polymers. Liquid contact angle data were obtained for ion-textured and untextured polymer samples. Results of tensile and fatigue tests of ion-textured metal alloys are presented. Preliminary data of tissue response to ion-textured surfaces of some metals, polytetrafluoroethylene, alumina, and segmented polyurethane have been obtained.

Weigand, A. J.↗

Thermal stability of the microstructure of an aged Nb-Zr-C alloy

The effects of thermal aging with and without an applied stress on the microstructure of a Nb-Zr-C alloy containing 0.9 wt percent Zr and 0.06 wt percent C were studied. Chemical analysis, metallographic examination, energy dispersive x-ray spectra of the bulk material, and chemical and x-ray analyses of the phase-extracted residue were used to characterize the microstructure. The samples examined were from a creep strength study involving hot and cold working, and various combinations of exposure to temperatures ranging from 1350 to 1755 K with and without applied load for times as long as 34,000 plus hours. The results showed that the initial microstructure consisted primarily of orthorombic precipitates of Nb sub 2 C which were partially or completely transformed to face-centered cubic carbides of nb and Zr, (Zr, Nb)C, upon prolonged exposure to elevated temperatures. Furthermore, it was found that the microstructure of the alloy is extremely stable owing to the very finely distributed precipitates throughout its matrix and along the grain boundaries. The lattice parameters of the cubic carbides were determed to vary from 0.458 to 0.465 nm as the Zr/Nb ratio varied from 38/62 to 75/25.

Uz, Mehmet↗

Thermal stability of the microstructure of an aged Nb-Zr-C alloy

The effects of thermal aging with and without an applied stress on the microstructure of a Nb-Zr-C alloy containing 0.9 wt percent Zr and 0.06 percent C were studied. Chemical analysis, metallographic examination, energy dispersive X-ray spectra of the bulk material, and chemical and X-ray analyses of the phase-extracted residue were used to characterize the microstructure. The samples examined were from a creep strength study involving hot and cold working, and various combinations of exposure to temperatures ranging from 1350 to 1755 K with and without applied load times as long as 34,000 plus hours. The results showed that the initial microstructure consisted primarily of orthorombic precipitates of Nb sub C which were partially or completely transformed to face-centered cubic carbides of Nb and Zr, (Zr, Nb)C, upon prolonged exposure to elevated temperatures. Furthermore, it was found that the microstructure of the alloy is extremely stable owing to the very finely distributed precipitates throughout its matrix and along the grain boundaries. The lattice parameters of the cubic carbides were determined to vary from 0.458 to 0.465 nm as the Zr/Nb ratio varied from 38/62 to 75/25.

Uz, Mehmet↗

Establishing In-House Titration Capabilities: Part I. Hydroxyl Group Titration through Acetic Anhydride Acetylation

This lessons learned document provides a detailed analysis of the hydroxy termination titration methods employed for determining hydroxyl group content in various chemical samples. The primary focus is on the evaluation of techniques such as ASTM E222 and their practical applications in laboratory settings. Through examination of method selection, sample preparation, and titration execution, key insights have been identified that enhance the accuracy and reliability of results. Notable findings include the advantages of using pressure bottle methods for improved heating uniformity and reduced solvent loss, as well as the challenges associated with endpoint detection in dark-colored solutions. Recommendations for alternative sampling and titration techniques are proposed to address these challenges. This document serves as a valuable resource for enhancing the effectiveness and efficiency of hydroxy termination titration methods in chemical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing TPS Microstructure: A Review of Some techniques

I. When seeking to understand ablator microstructure and morphology there are several useful techniques A. SEM 1) Visual characteriza3on at various length scales. 2) Chemical mapping by backscatter or x-ray highlights areas of interest. 3) Combined with other techniques (density, weight change, chemical analysis) SEM is a powerful tool to aid in explaining thermo/structural data. B. ASAP. 1) Chemical characteriza3on at various length scales. 2) Chemical mapping of pore structure by gas adsorption. 3) Provides a map of pore size vs. pore volume. 4) Provided surface area of exposed TPS. II. Both methods help characterize and understand how ablators react with other chemical species and provides insight into how they oxidize.

Gasch, Matthew↗

An ESCA study of lunar and terrestrial materials.

The technique of electron spectroscopy for chemical analysis (ESCA) is used to obtain rapid, nondestructive elemental analyses of selected lunar samples, and the chemical shift of the Fe(2p) line in lunar materials is found characteristic of iron in the Fe(2+) state. A difference in binding energy of approximately 0.5 eV is observed between the 0(1s) levels of the terrestrial minerals fayalite and quartz, and effects due to surface oxidation and absorption are also observed in terrestrial materials. The new ESCA technique is based on energy analysis at high resolution of electrons emitted from the surface of a sample on irradiation with X rays and is valuable for the study of the electronic structure of atoms and molecules.

Huntress, W. T., Jr.↗

Analysis of chromatograph systems using orthogonal collocation

Research is generating fundamental engineering design techniques and concepts for the chromatographic separator of a chemical analysis system for an unmanned, Martian roving vehicle. A chromatograph model is developed which incorporates previously neglected transport mechanisms. The numerical technique of orthogonal collocation is studied. To establish the utility of the method, three models of increasing complexity are considered, the latter two being limiting cases of the derived model: (1) a simple, diffusion-convection model; (2) a rate of adsorption limited, inter-intraparticle model; and (3) an inter-intraparticle model with negligible mass transfer resistance.

Woodrow, P. T.↗

Spectroscopic characterization of titanium 6-4 surfaces after chemical pretreatments

Several techniques have been used to study pretreated Ti 6-4 surfaces including scanning electron microscopy (SEM), electron spectroscopy of chemical analysis (ESCA), and, reflectance visibile spectroscopy. Each pretreatment type gives a characteristic surface morphology as seen by SEM. Elemental analysis of the Ti 6-4 surfaces was done using ESCA. Trace residual contaminants from particular chemical pretreatments are identified readily. Reflectance visible spectroscopy using indicator dyes placed on Ti 6-4 surfaces appears to be a feasible approach to establish surface acidity. Differences in surface acidity have been observed using bromthymol blue on Ti 6-4 surfaces pretreated by two different methods.

Chen, W.↗