Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capacity test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Impact of feed variability on cesium removal with multiple actual waste samples from the Hanford site

Here, the Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions (WRPS), will send initial low-activity Hanford waste tank supernate feeds to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. This lot of material was found to have superior performance in comparison to historic batches of CST. Ion exchange column and batch contact testing with supernate from Hanford tanks AP-105, AP-107 and AW-102 was performed to assess the impact of feed variability on system performance. These tests demonstrated that batch contact measurements provide a reasonable prediction of column capacities with some deviation in performance attributed to column dynamics. In addition, the variability in CST capacity for cesium in the various actual waste samples does not track with historical understanding of the competing cations, suggesting that tank waste samples contain other components that may significantly impact cesium loading.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of Silicon Impurity on the Hydrometallurgical Recovery of NCM622 Cathode

Hydrometallurgy is one of the best approaches to date for recycling LIBs due to its high efficiency, low energy usage, and industrial scalability. However, impurities have always been a thorny issue because they could have unintended impacts on the recovered cathode materials. This research marks the first systematic investigation into the influence of silicon impurity on the LiNi 0.6 Co 0.2 Mn 0.2 O 2 (NCM622) cathode obtained from hydrometallurgical recycling. Here we find that silicon nanoparticles will be nucleated at the center of the precursor particles during co-precipitation synthesis, and the silicon core will slowly dissolve in the surrounding ammonia, creating a special hollow structure in the particle. More importantly, the dissolution of silicon impurity will eventually lead to the deposition of silicates in the cathode material, which is an unfavorable result. Test data indicate that NCM622 cathode with 5 at% silicon has a capacity of 148.8 mAh g −1 after 100 cycles at 1/3 C, approximately 10 mAh g −1 lower than the virgin. Despite being relatively mild, the adverse influence of silicon impurity in hydrometallurgical recycling still requires attention.

25 ENERGY STORAGE↗

Environmental control on the distribution of metabolic strategies of benthic microbial mats in Lake Fryxell, Antarctica

Ecological theories posit that heterogeneity in environmental conditions greatly affects community structure and function. However, the degree to which ecological theory developed using plant- and animal-dominated systems applies to microbiomes is unclear. Investigating the metabolic strategies found in microbiomes are particularly informative for testing the universality of ecological theories because microorganisms have far wider metabolic capacity than plants and animals. We used metagenomic analyses to explore the relationships between the energy and physicochemical gradients in Lake Fryxell and the metabolic capacity of its benthic microbiome. Statistical analysis of the relative abundance of metabolic marker genes and gene family diversity shows that oxygenic photosynthesis, carbon fixation, and flavin-based electron bifurcation differentiate mats growing in different environmental conditions. The pattern of gene family diversity points to the likely importance of temporal environmental heterogeneity in addition to resource gradients. Overall, we found that the environmental heterogeneity of photosynthetically active radiation (PAR) and oxygen concentration ([O2]) in Lake Fryxell provide the framework by which metabolic diversity and composition of the community is structured, in accordance with its phylogenetic structure. The organization of the resulting microbial ecosystems are consistent with the maximum power principle and the species sorting model.

54 ENVIRONMENTAL SCIENCES↗

Drying Wet Stored and Corroded Magnox Fuel for Interim Dry Storage - 20187

To investigate the feasibility of drying corroded Magnesium alloy clad nuclear fuel, the corrosion products of inactive and unirradiated Magnox simulant dry corrosion product and dried corroded Magnox sludge were characterised by X-ray diffraction and thermogravimetric analysis. XRD identified brucite in the dried corrosion product and both brucite and hydromagnesite in the sludge. TGA identified mass loss on dehydration of ∼9.1% up to 250 deg. C and 27.9% from dehydroxylation up to 440 deg. C, with total mass loss of 41.9% up to 800 deg. C for the dried corrosion product. The sludge TGA showed 8.3% mass loss up to 250 deg. C from dehydration, 7.5% up to 330 deg. C from dehydroxylation and 31.4% mass loss up to 47.2% for decarbonation, with total mass loss of 49.2% up to 800 deg. C. Water removal up to 1.8 g was performed by cold vacuum drying (40 deg. C-120 deg. C) on a ≅14.8 g (wet) corroded Magnox sample. The process was monitored by observing pressure, dew point, temperature and gas flow changes supported by measuring the sample mass loss as water is removed. From these tests, it was observed that the dried corroded Magnox displayed some hygroscopic capacity which has implications for water retention following vacuum drying and the length of exposure required to achieve the desired dryness. Whilst at higher temperatures the water was removed faster, the increased temperature also risks the fuel cladding undergoing unwanted chemical reactions with the residual water during the process. However, at lower temperatures the achievable levels of dryness were reduced. Therefore, from these observations this work has identified that there is a temperature balance that may be necessary to optimise the drying process with respect to allowing the greatest level of dryness whilst restricting unwanted chemical reactions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comprehensive Assessment of On-And Off-Board Vehicle-To-Grid Technology Performance and Impacts on Battery and the Grid

This project defined, developed, and tested the open standards-based requirements, engineering design and system integration of on and off-vehicle Vehicle-to-Grid technologies both on the grid and on the PEV, to assess their effectiveness in implementing the use cases that create value for the grid, which in turn, can be passed on to the ratepayers and the PEV owners. The project comprised of three key categories of work and four key sub-areas of work. The three key categories were: On-Vehicle V2G, Off-Vehicle V2G, and impact of V2G operation on the battery capacity degradation. The four key sub-areas of work under each of these categories were: defining requirements, implementing the technology, performing system integration testing, and estimating the value of each of the grid services under specific assumptions, on a per-vehicle and on an aggregated basis. The technical implementation demonstrated the validity of standards-based approach to grid integration that led to interoperability, in addition to assessing the operational details with grid constraints imposed at the transformer level. The technology implementation also identified the subtle gaps in the standards definition to close the feedback loop on the accuracy of the standards as written, which are being implemented as revisions to the appropriate protocols. The battery impacts assessment developed a test cycle that the batteries from a real PHEV were subjected to for both the mobility-only and mobility with V2G specific energy cycling. While the battery impact results show a clear incremental degradation in response to additional throughput for V2G application purposes, the amount of additional kWh that can be made available without exceeding the end-of-life capacity definition of the battery at its 10-year warranty period was found to be significant. Given that the PEV battery being exercised during testing was a PHEV battery (smaller energy capacity), and 44% of its usable energy (i.e., SOC) was utilized daily for V2G applications, the EVs with much larger batteries will fare much better, either in terms of extracting more value in terms of incremental kWh for V2G, or in terms of relative incremental degradation of the capacity through the battery lifespan. Further, this battery was the second-generation Lithium-Ion chemistry circa 2015, which is at least two generations ago. Continual improvements in electrochemistry and manufacturing techniques as well as on-board capacity will enable the future batteries to provide even more energy for non-mobility-related services. Finally, the valuation of V2G energy services at the premise, distribution, and the ISO/market level was carried out for both the on-vehicle and off-vehicle cases, to understand both the GHG mitigation and operational efficiency improvements in quantitative terms. The analysis indicates that between $\$400$ and $\$1400$ per year of total value to the grid can be realized. When netted of costs to implement V2G either on or off-vehicle, the net value is available to be shared between the ratepayers and the EV owners. Over the life of the EV, therefore, this value becomes significant and can easily provide both ratepayer and EV owner benefits more than the cost of the equipment, either on or off-board, in addition to providing GHG mitigation benefits both on the grid and on the mobility sides. For these benefits to accrue, the key learnings from both the on- and off-vehicle V2G parts of the project indicate the need for at-scale demonstrations through involvement of real EV owners to validate both the technical feasibility, interoperability, as well as real grid benefits by performing extensive data collection and analysis. This will help inform the grid planners, the program designs, and tariff designers, as well as automotive and equipment manufacturers how best to create their products to maximize grid, ratepayer, and EV owner value.

30 DIRECT ENERGY CONVERSION↗

High-Voltage, Intermediate-Temperature, Fe- and Al-Mixed Metal Halide Molten Salt for Molten Sodium Battery Energy Storage

An inorganic Fe and Al halide-based, low-temperature molten salt catholyte is described, which, when paired with a molten sodium anode, has high operating potentials rivaling those of Li ion batteries. The newly developed catholyte consists of metal halides FeCl 3 /FeCl 2 –AlCl 3 –NaCl and is intended to cycle between Fe 3+ /Fe 2+ redox couples in the molten salt. The multicomponent molten salt was initially evaluated for phase behavior and basic electrochemical behavior before full battery testing. The assembled battery, utilizing a 20:35:45 (FeCl 3 :AlCl 3 :NaCl) composition, with a 50.83 Ah/kg theoretical gravimetric capacity and a specific energy of 176.95 Wh/kg, was cycled at variable depths of discharge (DoD) and current densities to determine its cycling efficiencies and limitations. In conclusion, preliminary cycling tests showed two operational potential regimes, with higher potential, 3.91 V (vs Na/Na + ), at low DoD and lower potential, 3.39 V (vs Na/Na + ), at high DoD with excellent energy efficiencies and cycling behavior under both regimes.

Aluminum↗

Building an EPA Class VI Permit Application

Summary To accelerate the commercialization of carbon capture and storage (CCS), the US Department of Energy (US DOE) is building on decades of characterization efforts and pilot-scale projects through their CarbonSAFE program. Administered through their National Energy Technology Laboratory, this program seeks to bring fully integrated projects to the sector that can store more than 50 million tonnes of CO2 over a 30-year period. The program, which was enacted before the enhancement of Internal Revenue Code Section 45Q, is in the capture assessment, characterization, and permitting phase. The objectives of this paper are to discuss (a) the injection permitting requirements of the CarbonSAFE projects; (b) information gathering in support of the permit; (c) the timelines of field development and permit-related activities; (d) the major technical components of the field development plan; and (e) early feedback from the regulators toward acceptance of the permit. In Mississippi, more than 30,000 acres have been characterized by six deep characterization wells, a deep groundwater well, and 92 line miles of 2D seismic as part of the CarbonSAFE Project ECO2S. During the acquisition of seismic data, all receiver lines were live, which resulted in the generation of a pseudo-3D seismic design. The incorporation of a 3D seismic survey was not included as part of this project due to logistical difficulties presented by the undulating, wooded surface terrain. A suite of openhole geophysical logs was taken from each well, allowing for a detailed interpretation of prospective storage reservoirs and confining intervals to complement the analysis carried out on the 290 ft of a whole core that was cut through the prospective confining zone and storage reservoir. The detailed geologic and reservoir data were assembled and entered into a 3D model to assess the injection capacity and the area of review (AoR). This information fed into the detailed corrective action, monitoring, testing, and postinjection site care (PISC) modeling. The results have been exceptional. The geologic assessment has revealed three primary storage targets, ranging in depth from 3,500 ft to 6,000 ft. These storage reservoirs net 1,300 ft of sandstone, with mean porosity and permeability of 29% and 3.6 darcies, respectively. Together, these reservoirs have storage capacities that may exceed 20 million tonnes per square mile, making this a gigatonne prospect. Forward modeling of the project resulted in an AoR of 16 sq miles, injecting about 8000 t/d, for 30 years, via two deep injection wells. The excellent confining characteristics of the caprock, relatively simple geologic structure, and lack of historical well drilling activity in this area provide excellent containment of the injected CO2. Based on this work, the project has proposed 20 years of PISC. To date, only two US CO2 injection permits have been granted. These projects relied on a singular capture point feeding a singular sequestration point (source to sink), and considerations have not been made to garner CO2 emissions from other industrial sources. The Kemper County Storage Complex is a first-of-its-kind storage hub concept that looks to develop an area capable of storing significant quantities of CO2 from the region. Also, this work will show how characterization efforts, geological and numerical modeling efforts, and plan development were constructed in support of permit and incentives acceptance.

Energy & Fuels↗

Iron-Doped Sodium Vanadium Oxyflurophosphate Cathodes for Sodium-Ion Batteries—Electrochemical Characterization and In Situ Measurements of Heat Generation

Sodium-ion batteries (NaIBs) are increasingly being envisioned for grid-scale energy-storage systems because of cost advantages. However, implementation of this vision has been challenged by the low-energy densities delivered by most NaIB cathodes. Toward addressing this challenge, the authors report the synthesis and characterization of a new iron-doped Na 3 Fe 0.3 V 1.7 O(PO 4 ) 2 F 2 cathode using a novel facile hydrothermal route. The synthesized material was characterized using scanning electron microscopy, X-ray diffraction, and Mössbauer spectroscopy techniques. The obtained discharge capacity in the half-cell configuration lies from 119 to 125 to 130 mA h/g at C/10 while tested using three different electrolyte formulations, dimethyl carbonate–ethylene carbonate (EC)–propylene carbonate (PC), diethyl carbonate–EC, and EC–PC, respectively. The synthesized cathodes were also evaluated in full-cell configurations, which delivered an initial discharge capacity of 80 mA h/g with NaTi 2 (PO 4 ) 3 MWCNT as the anode. Ionic diffusivity and interfacial charge transfer kinetics were also evaluated as a function of temperature and sodium concentration, which revealed that electrochemical rate performances in this material were limited by charge-transfer kinetics. To understand the heat generation mechanism of the Na/Na 3 Fe 0.3 V 1.7 O(PO 4 ) 2 F 2 half-cell during charge and discharge processes, an electrochemical isothermal calorimetry measurement was carried out at different current rates for two different temperatures (25 and 45 °C). The results showed that the amount of heat generated was strongly affected by the operating charge/discharge state, C-rate, and temperature. Altogether, this work provides a new synthesis route for the development of iron-doped Na 3 Fe 0.3 V 1.7 O(PO 4 ) 2 F 2 -based high-performance sodium cathode materials aimed at providing a viable pathway for the development and deployment of large-scale energy-storage based on sodium battery systems.

25 ENERGY STORAGE↗

Polysulfide entrapment and retardation in gel electrolyte Li–S batteries: experiments and modeling

Gelling the electrolyte in lithium–sulfur (Li–S) batteries provides advantages in terms of safety and mitigating polysulfide shuttling leading to reduced side reactions and dendrite growth on the anode side. In the current study, organic and ceramic crosslinkers have been used to improve the entrapment of polysulfides and prevent them from shuttling to the anode side. However, the performance of gel electrolytes is still far from being on par with liquid electrolytes in terms of raw capacity. The discharge curves exhibit an extended first plateau for gel electrolyte batteries compared to liquid electrolytes, showing that polysulfides are better trapped in the gel system. Yet, in the conversion of soluble polysulfides into insoluble polysulfides, the second plateau was delayed. Qualitative and quantitative analysis of the polysulfide diffusion in the liquid electrolyte and gel electrolyte systems were also conducted to predict the relative diffusivity ratio between the liquid electrolyte and gel electrolyte for simulation. To probe what happens at the end of the discharge, where the mass transport in the gel electrolyte appears to be slow, a modified discharge procedure was used where the cell is first paused after discharge and then discharged a second time before recharging normally. Coin cell tests for two gel electrolytes in addition to liquid electrolyte show up to 7% capacity recovery after the pause, which indicates that the diffusion of species during the pause is responsible for the failure recovery. Additionally, the recovery is higher for gel electrolytes compared to liquid, for higher C-rates, and for longer pause times. To better understand this behavior, a Li–S numerical model with mass transport limited reactions was used to examine the polysulfide diffusion coefficients expected in different electrolyte systems. The model is able to reproduce the trends seen in experiments and yields a higher recovery for smaller Li 2 S 4 diffusion coefficients, suggesting that insufficient Li 2 S 4 mass transport is responsible for failure at the end of discharge. By identifying the effect that gel electrolytes have on the state of the battery during discharge using both experimental and simulation methods, this work is a step towards leveraging the advantages of gel electrolytes and mitigating their weaknesses.

25 ENERGY STORAGE↗

On the Efficacy of Repeat Voltage Holds for Conditioning and Calendar Life Testing of Graphite and Silicon Cells

Voltage-hold (V-hold) protocols have shown promise toward calendar lifetime analysis of cells with graphite (Gr) and silicon (Si) anodes. In this work, repeat V-holds are performed on Gr and Si cells paired with lithium iron phosphate cathodes to delineate their beneficial role in formation and conditioning. We find that V-hold at the top of charge supplements constant current cycling in conditioning the cell to higher capacities for both Gr and Si cells after the first V-hold. A reduced order model provides the irreversible capacity proportions of each V-hold. With each repeat V-hold, parasitic loss of lithium to the solid electrolyte interphase (SEI) decreases on both Gr and Si cells. Gr cells show the square-root-of-time capacity loss behavior within 200 h of V-hold, indicative of its fast relaxation and low impact of reference performance test cycles on the SEI growth. Lifetime estimates from repeat V-holds on Gr can reach years. Si exhibits longer transition times from kinetic to diffusion-limited SEI growth, evidenced by the 400 h and 200 h holds showing square-root-of-time and linear behavior, respectively. Lifetime predictions from repeat V-holds on Si only reach 1–2 months, highlighting its limitations. Recommended duration of V-holds for Si cells should be ≥400 h.

25 ENERGY STORAGE↗

IDAES Enterprise: Generation Expansion Planning with Enhanced Requirements for Capacity Adequacy Under Renewable Intermittency

Achieving net zero carbon emissions likely requires future power systems to integrate new, flexible energy technologies to accommodate higher levels of capacity from variable renewable energy sources. To determine the optimal deployment of new electricity capacity and to study the likelihood of deployments of new energy technologies, an expansion planning model has been developed as part of the IDAES-Enterprise suite of grid models. The Generation Expansion Planning (GEP) model is a multi-period model in which investment decisions occur yearly, and a Unit Commitment (UC) problem is examined on an hourly timescale. To reduce computational complexity of the GEP model, the UC problem is solved for average “representative days” which leaves out extreme, but relatively common, scenarios in which low renewable generation occurs, leaving the system with inadequacy in capacity. The IDAES-Enterprise GEP model has been modified to include these extreme scenarios while keeping the model reasonably tractable. Specifically, a lazy constraint technique was implemented to check for capacity adequacy on an hourly basis over a large data set of aligned load-wind-solar profiles. As a vast majority of the capacity constraints will not be violated, the technique lowers computational expense by searching for violated capacity constraints over an “iterative manner,” adding those infeasible constraints back into the model. Results on a test case of the Southwest Power Pool shows that the lazy constraint technique significantly reduces retirements and increases installments of natural gas combined cycles and flexible natural gas units. It also reduces some retirements of coal units. These modifications provide a more reasonable estimation of required dispatchable power generation capacity to ensure feasibility during peak net load.

Liu, Peng↗

Shell Predictive Battery Life Models (SPBLM) [SWR-20-35]

Battery life models to predict the capacity fade and resistance growth of lithium-ion batteries from various manufacturers with different chemistries. The battery life model is trained on experimental test data, and accounts for calendar and cycling aging mechanisms as functions of cell environmental conditions and use. The battery life model is then used to predict capacity fade and resistance growth under any arbitrary aging scenario.

Smith, Kandler↗

Illuminating the pathways to carbon liberation: a systems approach to characterizing the consequential unknowns of carbon transformation and loss from thawing permafrost peatlands (Final Report)

The IsoGenie3 Project delivered new systems-level insights into carbon cycling in thawing permafrost landscapes, with an emphasis on methane and carbon dioxide emissions. From >200 samples from the site collected over a decade, co-analyzed for geochemistry and microbiology, the team recovered ~1,500 assembled microbial genomes and ~1,900 viral population genomes, revealing appreciable genetic novelty - from a new highly abundant bacterial phylum, to novel methane consumers and their activities, to rampant viral novelty. IsoGenie3 linked these organisms to carbon compound transformations (which define the cycling of organic matter in soils, and the loss of the greenhouse gases carbon dioxide and methane), and saw that the microbes at each stage of permafrost thaw had different genetic potential to degrade categories of compounds, expressed that genetic potential differently, and actually transformed carbon compounds into greenhouse gases in different ways. IsoGenie 3 identified that some of the thaw-stage differences were due to plant-microbiome relationships; the plant species across the thaw gradient contributed different carbon compounds into the soil, and hosted distinct microbiota (differing among parts of plants as well as species). Lastly, microbes in the saturated post-thaw conditions appeared likely to contribute to the mobilization and toxification of mercury released during thaw. In parallel with ongoing field sampling and analysis, hypotheses arising from field observations were tested via lab incubation experiments. When communities are taken out of their native habitats, they behave differently, and the team first rigorously quantified the magnitude of this effect on microbiome composition and functional capacity, organic matter composition, and gas production; overall the main system processes were maintained in the lab incubations under the conditions tested. Further, the microbial data could inform geochemical reaction network models of those processes. Then, the team ran experiments with additions of compounds, varying temperature, and “live” vs. “dead” peat (the latter having been gamma irradiated, with a few additional variants to control for methodological artifacts). From these, we (a) determined the importance of plant-derived soluble phenolic compounds in bogs’ extraordinary recalcitrance of organic matter, and carbon gas emissions skewed to carbon dioxide; (b) proposed an abiotic ‘tanning’ mechanism, which could contribute to Sphagnum’s inhibitory effect on anaerobic decomposition through alteration of N availability. IsoGenie3 illuminated longer-term and landscape-scale interactions of permafrost thaw and carbon cycling, advancing knowledge of the drivers of methane dynamics not only across in the permafrost-associated peatland (where hydrology and plant communities dictate microbiomes) but also their interconnected lakes (where sediment carbon quality and resident microbiota are determined by position within lake, and lake features). By leveraging observations of site methane dynamics extending well before this project, the team was able to construct a 44-year portrait of the interplay of permafrost thaw, hydrology, vegetation dynamics, and carbon gas emissions, and the doubling of the fully-thawed fens over this time. From the detailed study of this focal site, IsoGenie3 also aimed to improve model representation of these kinds of sites and processes. To improve predictions of methane transformations, we incorporated acetate and isotope dynamics into the ‘DNDC’ biogeochemistry model. In addition, recovered genomes were grouped into ‘functional groups’, i.e. the genomes that perform a specific function of interest, then used to parameterize maximum growth rate and optimum growth temperature (via signatures in their sequence composition) for the BioCrunch model. The BioCrunch model was then in turn used to test the impact of increasing functional resolution of the microbes, on the carbon gas emissions. Lastly for modeling, the ecosys model was parameterized from the microbial and other data, and used to evaluate drivers of e.g. change in methane emissions. Finally, this project also led to the development of a range of new methods and tools, a new metric of organic matter decomposability, as well as a graph-database solution to multidisciplinary data storage and querying. This project’s ongoing analyses at our focal site also contributed to broader advancements in understanding elements of genetic plasticity and methane metabolism, climate change microbiology and community assembly, global peatland geochemistry and Arctic lakes’ roles in climate feedbacks.

54 ENVIRONMENTAL SCIENCES↗

Development and Testing of an Advanced Cascaded Thermoelectric Residential Heat Pump

Electricity-driven heat pumps using vapor compression cycle are an energy-efficient solution to replace fossil fuel burning and reduce greenhouse gas emissions for space heating in residential buildings. However, heating capacity and Coefficient of Performance (COP) of heat pumps degrade significantly with increasing temperature difference between ambient and indoor environments. Residents and building owners are hence reluctant to fully embrace electric heat pumps. The use of conventional all-electric heat pumps also causes concern for electric utilities due to an increased winter peak demand arising from the use of supplemental electric resistance heaters. Our research is an attempt to alleviate these concerns by designing and laboratory testing a thermoelectric (TE) heat pump cascaded with a vapor compression cycle to enhance heating capacity and COP. TE modules increase the subcooling in the refrigerant liquid of the vapor compression cycle to enlarge the evaporating capacity and works at an efficiency greater than a conventional electric resistance strip. This results in a simple, affordable, efficient and highly controllable solution to adequately meet space heating needs in dwellings. The laboratory testing of the 3-stage cascaded TE heat pump performed in this research has exhibited a higher heating capacity by above 15%, while maintaining a heating COP of 2.0-3.6 in the ambient temperature range of -18˚C to 8˚C (0˚F to 47 ˚F), which represents more than 60% of winter temperatures observed in US. If successfully commercialized, this technology can advance space-heating electrification by overcoming consumer cost barrier of heat pumps.

Shen, Bo↗

Biosorption of copper from aqueous solutions utilizing agricultural wastes

Abstract The purpose of this study was to determine the copper (Cu) biosorption capacities of several agricultural wastes from aqueous solutions. Samples of agricultural wastes were tested unaltered and after hydrochloric acid (HCl) treatment. Additional parameters tested include sample dose, contact time, particle size, mixing temperature, and the concentrations and pH of the Cu solutions. Desorption studies were performed to determine if the removed Cu could be recovered. In addition, tests were conducted to determine if the agricultural waste samples (AWS) could be reused for additional Cu biosorption cycles. The results of this study demonstrate a wide range of Cu biosorption proficiencies ranging from 0% to 100% removal. The parameters that resulted in higher Cu removal include higher pH and lower Cu solution concentration. Desorption results showed a 58% to 86% Cu recovery rate. Three of the five reused AWS were effective at removing Cu during subsequent trials. Therefore, these AWS types can be reused for additional Cu biosorption cycles. Hence, it is possible that using those AWS for metal treatment could reduce hazardous waste disposal inefficiencies and costs by avoiding disposing of spent AWS following each Cu biosorption cycle.

Rizzuti, Anthony M.↗

An organic bifunctional redox active material for symmetric aqueous redox flow battery

Symmetric redox flow batteries utilizing a single redox active material as catholyte and anolyte, offer a plausible and unique strategy to alleviate cross-contamination issues during cycling, making them an ideal energy storage device for large scale applications. In this work, a low-cost riboflavin organic molecule is coupled with a 2,2,6,6-Tetramethylpiperidinyl-N-oxyl (TEMPO) radical molecule to form a single Riboflavin-TEMPO (RIBOTEMPO) bifunctional redox active material, which is used in both aqueous anolyte and catholyte. Cyclic voltammetry analysis of the combined molecule displays electrochemically reversible reactions for the redox couples at 0.72 V and 0.51 V versus Hg/Hg2SO4, leading to a theoretical cell voltage of 1.23 V. A symmetric cell testing demonstrated over 100 consecutive charge/discharge cycles with nearly 80% coulombic efficiency and capacity retention of 44.7% at a current density of 2.5 mA cm(-2). By utilizing a pH neutral supporting electrolyte, a lowcost, safe, and environmental-friendly redox flow battery is achieved. This work provides a pathway for the design and development of bifunctional redox active molecules for symmetric battery applications.

25 ENERGY STORAGE↗