At least 289 records · Page 16

The monogroove high performance heat pipe

The development of the monogroove heat pipe, a fundamentally new high-performance device suitable for multi-kilowatt space radiator heat-rejection systems, is reported. The design separates heat transport and transfer functions, so that each can be separately optimized to yield heat transport capacities on the order of 25 kW/m. Test versions of the device have proven the concept of heat transport capacity control by pore dimensions and the permeability of the circumferential wall wick structure, which together render it insensitive to tilt. All cases tested were for localized, top-side heat input and cooling and produced results close to theoretical predictions.

Alario, J.↗

Low-Cost High-Power Anodes for Electric Vehicle Batteries

Saratoga Energy has developed a system for making graphite from carbon dioxide. LBNL has experience in benchmarking graphites for Li-ion battery applications. In half cells, we tested graphites for their reversible capacity and their rate capability. They used this data to support a phase II proposal that was funded by DOE to scale up their best material and test in larger cells.

25 ENERGY STORAGE↗

Initial evaluation tests of Eagle-Picher Industries 9.0 ampere-hour nickel-cadmium spacecraft cells for the heat capacity mapping mission satellite and the stratospheric aerosol and gas experiment satellite

The results of tests to insure that all cells put into the life cycle program are of high quality are reported. The tests consisted of the following: phenolptalein leak tests, internal short test, charge efficiency test, and overcharge tests. The results of tests for 10 cells are tabulated.

Harkness, J. D.↗

Ion Exchange Technology Development in Support of the Urine Processor Assembly Precipitation Prevention Project for the International Space Station

In support of the Urine Processor Assembly Precipitation Prevention Project (UPA PPP), multiple technologies were explored to prevent CaSO4 dot 2H2O (gypsum) precipitation during the on-orbit distillation process. Gypsum precipitation currently limits the water recovery rate onboard the International Space Station (ISS) to 70% versus the planned 85% target water recovery rate. Due to its advanced performance in removing calcium cations in pretreated augmented urine (PTAU), ion exchange was selected as one of the technologies for further development by the PPP team. A total of 12 ion exchange resins were evaluated in various equilibrium and dynamic column tests with solutions of dissolved gypsum, urine ersatz, PTAU, and PTAU brine at 85% water recovery. While initial evaluations indicated that the Purolite SST60 resin had the highest calcium capacity in PTAU (0.30 meq/mL average), later tests showed that the Dowex G26 and Amberlite FPC12H resins had the highest capacity (0.5 meq/mL average). Further dynamic column testing proved that G26 performance is +/- 10% of that value at flow rates of 0.45 and 0.79 Lph under continuous flow, and 10.45 Lph under pulsed flow. Testing at the Marshall Spaceflight Center (MSFC) integrates the ion exchange technology with a UPA ground article under flight-like pulsed flow conditions with PTAU. To date, no gypsum precipitation has taken place in any of the initial evaluations.

Mitchell, Julie L.↗

A survey of thermocouple anomalies: mechanisms, interpretation, and mitigation

Thermocouples (TCs) are a critical diagnostic sensor for high enthalpy environments including thermal protection systems (TPS) for atmospheric re-entry, hypersonic wind tunnels, and arc jet test facilities. They are used for both evaluating facility environmental conditions (enthalpy, heat flux) as well as for measuring in-situ material thermal response under test conditions (thermal conductivity, heat capacity, B’, etc.). Consequently, accurate TC measurements are fundamental for both material and facility verification and validation (V&V). However, a number of TC anomalies have been observed in both ground tests and flight instrumentation. These anomalies are caused via various coupling mechanisms: electrostatic gradients, temperature-dependent electrical shorts, radio pickup, magnetic induction, and pressure-dependent leaks. All of these mechanisms can, if unaddressed, result in obviously compromised results or worse, non-physical measurements which appear reasonable. This work will survey known anomaly mechanisms and discuss ongoing efforts to quantify and mitigate anomaly mechanisms including anomaly modeling, diagnostics, and new TC designs/development.

thermocouple anomalies↗

Electromagnetic Thermocouple (TC) Anomaly Mechanisms During Atmospheric Entry

Thermocouples (TCs) are a critical diagnostic sensor for high enthalpy environments including Thermal Protection Systems (TPS) for atmospheric entry, hypersonic wind tunnels, and arc jet test facilities. They are used for both evaluating facility environmental conditions (enthalpy, and heat flux) as well as for measuring in-situ material thermal response under test conditions (thermal conductivity, heat capacity, etc.). Consequently, accurate TC measurements are fundamental for both material and facility Verification and Validation (V&V). However, a number of electromagnetic TC anomalies have been observed in both ground tests and flight instrumentations. These anomalies are caused via various coupling mechanisms: surface voltage coupling, Hall effect currents, and RF rectification. All of these mechanisms can, if unaddressed, result in obviously compromised results or worse, non-physical measurements which appear reasonable. This talk will provide an overview of each of these anomaly mechanisms and discuss ongoing efforts to quantify and mitigate them.

Magnus Haw↗

A Survey of Thermocouple Anomalies: Mechanisms, Interpretation, and Mitigation

Thermocouples (TCs) are a critical diagnostic sensor for high enthalpy environments including thermal protection systems (TPS) for atmospheric re-entry, hypersonic wind tunnels, and arc jet test facilities. They are used for both evaluating facility environmental conditions (enthalpy, heat flux) as well as for measuring in-situ material thermal response under test conditions (thermal conductivity, heat capacity, B’, etc.). Consequently, accurate TC measurements are fundamental for both material and facility verification and validation (V&V). However, a number of TC anomalies have been observed in both ground tests and flight instrumentation. These anomalies are caused via various coupling mechanisms: electrostatic gradients, temperature-dependent electrical shorts, radio pickup, magnetic induction, and pressure-dependent leaks. All of these mechanisms can, if unaddressed, result in obviously compromised results or worse, non-physical measurements which appear reasonable. This work will survey known anomaly mechanisms and discuss ongoing efforts to quantify and mitigate anomaly mechanisms including anomaly modeling, diagnostics, and new TC designs/development.

Thermocouple Anomalies↗

Predicting Li-Ion Battery Capacity Fade Using Early-Life Data and a Hybrid Data-Driven Gaussian Process-Bayesian Regression Approach

Accurately predicting Li-ion battery capacity trajectories using early-life data can dramatically improve battery-life understandings and be used to rapidly evaluate design/cost/performance trade-offs when developing new battery materials. Accurate early-life predictions enable researchers to quickly iterate over cell designs and material precursor properties without consistently cycling cells to failure. To this end, we present a toolbox that uses a combined Gaussian Process and Bayesian regression approach that capitalizes on signals other than just capacity (e.g., dQ/dV, voltage drops) to rapidly predict capacity-fade trajectories. The prediction tool uses Bayesian regression to fit functional forms, e.g., power law, sigmoids, etc., to predict capacity-fade dynamics. By fitting functional forms, the capacity fade can be interrogated at any point in the future, allowing for early cell-failure prediction. Additionally, Bayesian regression allows for accurate uncertainty estimates that account for cell-to-cell variability (aleatoric uncertainty) and the lack of observation data (epistemic uncertainty). By only using early cycle data to predict the capacity fade trajectory, uncertainty bounds at end-of-life can be extremely large. The large uncertainty bounds are further exacerbated because there is no systematic way to define the prior distribution of the functional forms' parameters. We improve our the predicted trajectory confidence interval of our predicted trajectory using two methods. First, we shows that a small amount of held-out cycling data is sufficientuse some train cells, that have been cycled to failure to derive information regarding the appropriate prior distributions for the functional forms' parameters of the functional form, effectively leading to data-driven priors.. We propose constructing the data-driven priors by first running a Bayesian regression starting with uninformed priors to generate intermediate cell-specific posterior parameter distributions. These posterior distributions are combined using a Ggaussian mixture model for each parameter to create the data-driven priors. These mixture models serve as the data-driven prior distributions for the parameters for. Second, we derive multiple features, e.g., C_dchg 0.5 DoD 0.5, log (|mean(dQ/dV_(w_3-w_0 ) (V)|), etc., from the train cellsheld-out cycling data, identify which the features are that best predicting capacity at early/mid-life cycles, and then create Ggaussian process regression models that are used for predicting capacity at early/mid-life cycles for the test cells (see blue dots with error bars in Fig 1b). Finally, these predicted data-points are used in addition to the actual early cycle data capacity fade to construct the Bayesian regression trajectory for the test cell s. Notably. We note that these two methods are complementary and can be combined with each other. We evaluate the performance of our proposed method on an testing open-source dataset from Iowa State University and Iowa Lakes Community College (ISU-ILCC). This dataset comprises of 251 nickel-manganese-cobalt/graphite Lithium-ion cells that are cycled under 63 different conditions. We compute the mean average percentage error (MAPE) and negative log predictive density (NLPD) to quantify the efficacy of our method. Our initial findings suggest that, when only few observations are available, for test cells, when using only Bayesian regression with uninformed priors, a power law functional provides the most accurate predictions. with very few data points. However, asHowever, a the number of data points increases, a twin sigmoidal function becomes more accurate as the number of observations further increases. We also find that using as little as 10% of the data set towards generating data-driven priors can lead to significant improvement in prediction accuracy when using early cycle data. Lastly, we found that augmenting early-cycle data with Gaussian process-predicted capacity data for Bayesian regression greatly improves the prediction accuracy. We will present a comprehensive comparison of our methods to other methods available in the literature and apply this method to additional battery datasets.

42 ENGINEERING↗

Sensitivity and history match analysis of a carbon dioxide “huff-and-puff” injection test in a horizontal shale gas well in Tennessee

Due to improvements in well development, shale gas production has gained importance recently, especially in the United States. To improve gas production and develop a better understanding of shale reservoirs, researchers are conducting field tests to monitor CO 2 storage and enhanced gas recovery. Reservoir simulations can then utilize these field results for sensitivity studies, uncertainty analysis, history matching, gas production forecasts, and CO 2 storage capacity estimations. One such field test was performed for the Chattanooga Shale formation in Morgan County, Tennessee. Approximately 463 tonnes (510 tons) of CO 2 was successfully injected into a hydraulically fractured horizontal well over a thirteen-day period in March 2014. The injection test was achieved in four steps: pre-injection, injection, soaking, and flowback. In this paper, those steps were modeled with a reservoir simulator to match the historic production and injection rates with gas component compositions and forecast the production for five years. The reservoir fluid was modeled as a multi-component gas, including CH 4 , C 2 H 6 , C 3 H 8 , N 2 , and CO 2 . Langmuir constants, reservoir pressure, and fracture network volume were adjusted to match simulation results with observed production rates and gas composition. Results showed that, under the same reservoir conditions, each gas component behaves differently by way of compositional changes in production. CH4 behaves like N2, while CO 2 behaves like heavier hydrocarbons such as C 2 H 6 and C 3 H 8 . CO 2 plume results showed that, after injection, the produced CO 2 is mostly derived from fractured limestone (i.e., Fort Payne Formation) because the injected CO 2 is not adsorbed in limestone but rather by shale formations.

03 NATURAL GAS↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company 40.0 ampere hour nickel cadmium spacecraft cells for the tracking data relay satellite system

Average end of charge voltages and pressures, and capacity output in ampere hours are presented. Test limits specify those values at which a cell is to be terminated from charge or discharge. Requirements are based on past cell performance data. The requirement does not constitute a limit for discontinuance from testing. The nickel cadmium batteries were screened for internal shorts, low capacity, electrolyte leakage, or inability of any cell to recover its open circuit voltage above 1.150 volts during the internal short test.

Hall, S. W.↗

Long cycle and calendar life of Si-based Li-ion batteries enabled by localized high-concentration electrolytes and their surprising water tolerance

Silicon-based anodes promise an increase in energy density for Li-ion batteries, yet they suffer from a poor calendar life. Researchers have posited that fluorinated lithium salt forms reactive side products that destroy the solid electrolyte interphase (SEI), even without cycling. HF is one such reactive side product formed from trace water contamination in the electrolyte. Some electrolytes, such as localized high concentration electrolytes (LHCEs) may improve cell stability in highly reactive systems, such as Li metal and Si. In the present study, LHCEs containing 200-300 ppm of water retained up to 8% greater capacity (1200-1300 mAh/g Si) in calendar life tests over 200 days compared to dried electrolytes (< 20 ppm water). Calendar aging took place at 100% state of charge. Cells with 200-300 ppm water performed comparably to cells with 20 ppm water in cycle life tests (900-1000 mAh/g Si) . Even adding 1000 ppm water did not lead to rapid capacity fade in cells undergoing cycle life tests. Nano-FTIR spectroscopy revealed chemical and structural differences in the SEI for cells with 1000 ppm water compared to 200-300 ppm water. The SEI differences, including increased Li2O concentration, may have contributed to improved calendar life. This research reveals the capabilities of LHCEs to improve the calendar and cycle life of Si-based Li-ion batteries, despite the presence of a highly reactive contaminant.

25 ENERGY STORAGE↗

Pelletization with Spark Plasma Sintering and Characterization of Metal Iodides: An Assessment of Long-Term Radioiodine Immobilization Options

Four promising iodine “getter” materials (Ag, Cu, Bi, and Sn) for radioiodine capture were assessed in their pure metal-iodide (MI x ) pelletized forms to compare relative chemical durabilities. To study chemical durability, commercial MI x compounds of AgI, BiI 3 , BiOI, CuI, and SnI 4 were converted to dense monolithic pellets using spark plasma sintering. Semidynamic leach testing in the form of modified ASTM C1308 tests was then performed on the pellets in two different forms including unmounted (as-pressed) specimens (i.e., “U”) and epoxy-mounted specimens (i.e., “M”) with polished surfaces. The chemical durability results and sample characterizations showed that three of the five MI x compounds tested (i.e., AgI, CuI, and BiOI) displayed moderate to high leach resistances. Further, the remaining two MI x compounds (i.e., BiI 3 and SnI 4 ), which are both desirable iodine waste forms due to their high iodine loading capacities, readily decomposed during leach testing, indicated by crystallographic changes in the specimens as well as large amounts of iodine detected in the leachate solutions. The instabilities of BiI 3 and SnI 4 raise uncertainties for using the base metals/cations (i.e., Bi 0 /Bi 3+ and Sn 0 /Sn 4+ , respectively) as viable getters for radioiodine capture due to likely poor waste form chemical durabilities after capture and consolidation into waste forms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low temperature performance of lithium/silver vanadium oxide cells

Lithium/silver vanadium oxide cells for low temperature applications have been developed. Prismatic and spirally wound AA cells were tested under constant load discharge of 0.3 to 1.8 amps or pulse discharge of 0.225 or 1.0 amps at temperatures from -40 to 25 C. At -40 C with current densities of 2.5 mA/cm2, 23 percent of theoretical capacity was achieved under constant load discharge and 40 percent of theoretical capacity was achieved under pulse test. Self-discharge estimates of 0.7 percent per year at 25 C were obtained from microcalorimetry. Preliminary safety testing of the cells revealed no violent performance under short circuit or crush tests.

Takeuchi, E. S.↗

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗

Nonproliferation and Arms Control Research and Development (NPAC R&D) [Slides]

NPAC R&D focus areas include: Advancing U.S. capabilities to detect and characterize nuclear weapon development activities globally, including material production, the movement of special nuclear materials and nuclear weapons, and the testing or use of nuclear weapons, Supporting the development and testing of policy options and technical capabilities for international nuclear safeguards, arms control / treaty verification, nuclear export controls, and nonproliferation initiatives consistent with U.S. Government goals and objectives to enable monitoring and verification, Utilizing uranium, lithium, and high explosives (HE) materials expertise to support national-level activities in nuclear forensics and nuclear detection technology testing and evaluation, Providing unique training and capacity-building programs, particularly with the Nuclear Detection and Sensor Testing Center (NDSTC), and Engaging internationally to promote nonproliferation and arms control norms and best practices through bilateral and multilateral work.

36 MATERIALS SCIENCE↗

Bipropellant shut-off valve

An advanced design of an all metal, fast response, bipropellant, shut-off valve for use on long duration space missions is reported. The valve provides the flow control capability for a 1,000 lb thrust, bipropellant engine using oxygen difluoride and diborane as propellants. The shutoff seal selection is a soft-on-hard metal concept. The soft seal is a spherical shell that seats against a hard conical seat. Beryllium copper and beryllium nickel seals were selected to seal against an electrolyzed Inconel 718 seat. Poppet shaft sealing is achieved by use of hydroformed, Inconel 718 bellows. Two valve assemblies were fabricated and subjected to a series of tests including leak, response time, flow capacity, dry cycles, water cycles, liquid nitrogen cycles, liquid fluorine cycles, and lead-lag operation cycles. These tests demonstrated the ability of the valve to meet design goals.

Smith, J. V.↗

Plasma viscosity elevations with simulated weightlessness

A hypothesis correlating an increase in blood viscosity during bed rest to a decrease in aerobic capacity during simulated weightlessness is tested. Eight human subjects were studied on the sixth day of bed rest during two consecutive 10-d bed rest periods separated by a 14-d recovery interval designed to simulate the flight-layover schedule of Shuttle astronauts. Plasma viscosity and volume were measured, together with maximal aerobic capacity (VO2max). An increase in hematocrit, plasma protein, and fibrinogen concentrations was found, contributing to an elevation in plasma viscosity. VO2max decreased significantly in the first, but not the second bed rest cycle, and though many individuals exhibited a decrease in plasma volume and aerobic capacity coupled with elevated plasma viscosity, correlations between these variables were lacking. It is concluded that the decrease in VO2max observed following simulated weightlessness cannot be attributed to alterations in muscle blood flow resulting from increased blood viscosity.

Martin, D. G.↗

Evaluation and characterization of the methane-carbon dioxide decomposition reaction

A program was conducted to evaluate and characterize the carbon dioxide-methane (CO2-CH4) decomposition reaction, i.e., CO2 + CH4 = 2C + 2H2O. The primary objective was to determine the feasibility of applying this reaction at low temperatures as a technique for recovering the oxygen (O2) remaining in the CO2 which exits mixed with CH4 from a Sabatier CO2 reduction subsystem (as part of an air revitalization system of a manned spacecraft). A test unit was designed, fabricated, and assembled for characterizing the performance of various catalysts for the reaction and ultraviolet activation of the CH4 and CO2. The reactor included in the test unit was designed to have sufficient capacity to evaluate catalyst charges of up to 76 g (0.17 lb). The test stand contained the necessary instrumentation and controls to obtain the data required to characterize the performance of the catalysts and sensitizers tested: flow control and measurement, temperature control and measurement, product and inlet gas analysis, and pressure measurement. A product assurance program was performed implementing the concepts of quality control and safety into the program effort.