Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Cooling and Heating Season Impacts of Right-Sizing of Fixed- and Variable-Capacity Heat Pumps With Attic and Indoor Ductwork

A new generation of central, ducted variable-capacity heat pump systems has come on the market, promising very high cooling and heating efficiency. They are controlled differently than standard fixed-capacity systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they vary their cooling and heating output over a wide range (approximately 40% - 118% of nominal full capacity), thus staying 'on' for 60% - 100% more hours per day compared to fixed -capacity systems. Experiments in this research examined the performance of 2-ton and 3-ton fixed- and variable-capacity systems and the impacts of system oversizing.

BA-PIRC↗

Establishing a Technical Assistance Network to Build Capacity in Southwest Alaska (Southwest Alaska Energy Network - Final Report)

The Southwest Alaska Municipal Conference (SWAMC) is a non-profit regional membership economic development organization that represents the Aleutian/Pribilof Islands, Bristol Bay, and Kodiak regions of southwest Alaska. SWAMC applied for the DOE-OIE Establishment of an Inter-Tribal Technical Assistance Energy Providers Network grant FOA to work with our partners to provide energy planning and project development technical assistance. The project team was made up of SWAMC, three regional organizations, a management consulting firm, and a panel of technical consultants. SWAMC sub-contracted with the three Alaska Native regional non-profit organizations – Aleutian Pribilof Islands Association (APIA), Bristol Bay Native Association (BBNA), and Kodiak Area Native Association (KANA) – to fund full or partial Regional Energy Coordinator (REC) positions. The project period ran from September 2016 to March 2020. The project goal was to help southwest Alaska regional tribal partners and communities to develop efficient and financially sustainable structures for identifying and developing energy projects that enhance community resiliency and energy sustainability. This project established energy coordinators and management structures in the Aleutian, Bristol Bay, and Kodiak regions to expand technical assistance capacity of regional residents; demonstrate this capacity by advancing energy efficiency, heat, and power supply projects; and secure long-term funding commitments to establish a sustained technical assistance structure. The project team expanded technical assistance capacity of energy coordinators and regional stakeholders in several ways: by providing funding for the SWAMC project manager to attend three Office of Indian Energy trainings; for energy coordinators to attend numerous energy conferences; for utility clerks from several villages to receive one-on-one reporting training on Alaska’s Power Cost Equalization electric subsidy program; and for the Kodiak REC to complete the Arctic Remote Energy Networks Academy and NREL’s Executive Energy Leadership Academy. The energy coordinators demonstrated and shared their increased capacity by hosting several public events: SWAMC hosted two full-day energy workshops in February 2017 and 2018; the Kodiak REC hosted seven Energy Committee meetings for Kodiak stakeholders and gave several presentations at other events; and SWAMC and BBNA organized a Bristol Bay Regional Energy Visioning Session in May 2019. The project team created platforms to both share and request information to involve energy stakeholders in this project, including an energy website, a Facebook group, a periodic newsletter, surveys, mass emails, and paper mailers. An increase in regional capacity was demonstrated through several grant awards, including a $1.2 million USDA grant for Akhiok for an electric distribution infrastructure replacement; an AHFC Kickstarter grant for Aleknagik to audit 2 Tribal and 3 City buildings; and installation of an Air Source Heat Pump demonstration project in Atka. Two communities and one region – Ouzinkie (May 2017), Ugashik (July 2017), and the Bristol Bay region (May 2019) – utilized DOE’s technical assistance services to hold Strategic Energy Planning sessions with NREL and DOE facilitation assistance. And in early 2018, SWAMC established a parallel program, funded through a USDA Energy Audit and Renewable Energy Development grant to provide subsidized energy audits for small businesses in the region. SWAMC and partners have now completed energy audits of over 60 businesses (buildings and fishing vessels) and are currently operating a third round of the USDA program. Fifteen of those business owners have now received additional grant funding to cover 25% of the cost of the energy efficiency upgrades identified in the audit. This technical assistance structure will be sustained beyond DOE grant funding in several forms. As a sign of increased grant writing and project management capacity, the Kodiak Regional Energy Coordinator applied for and received a USDA Community Facilities Technical Assistance and Training grant to continue work begun under this program. Energy coordination tasks have been folded into existing economic development positions at SWAMC and at BBNA, ensuring long-term outreach and support in the region.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Bench-Scale Development of Promoted High-Capacity Structured Sorbents (Final Technical Report)

The project objective was to develop high-capacity structured sorbent capable of achieving low CO 2 removal from air. The sorbent framework consists of an amine-functionalized onto hydrophobic polymer backbone with an added promoter. The functionalized amine provides high CO 2 capacity and adsorption rates and the polymer backbone to reduce water uptake. For the sorbent development, multiple functionalized amines and promoters were assessed to select a candidate that achieved high CO 2 capacity, high adsorption rate, and high stability. A sorbent-coated filter design was selected as the structured sorbent, which provides high sorbent loading capacity and contains an electrically conductive nonwoven filter substrate that can be Joule-heated to provide efficient utilization of available electricity for sorbent regeneration. A commercial partner operated a pilot filter manufacturing line to produce the filter panels coated with the developed sorbent. A 1 kg CO 2 /day bench unit was designed and fabricated to test the structured filter sorbent. The key achievements from the structured sorbent development activity were demonstrating that existing filter industrial-scale processes can be used for manufacturing Susteon’s structured sorbent and completing a proof-of-concept demonstration of the commercially manufactured structured sorbent filters for CO 2 capture from air with direct, Joule-heated regeneration. A techno-economic assessment with sensitivity analysis was conducted on a 100,000 TPY facility with 85% operating capacity. Through sorbent optimization and process design improvements, it is estimated that the cost of capture was reduced from $\$$349/tCO 2 to $\$$241/tCO 2 . The TEA projects further reductions to $165/tCO 2 through enhancements in CO 2 adsorption rate and sorbent capacity and reducing manufacturing and scale up risks. A life cycle analysis was conducted on the same 100,000 TPY facility and confirmed that the facility’s electricity demand drives its greenhouse gas impact. It was determined that electricity supplied through the current grid mix would result in net-positive CO 2 emissions and that achieving net-negative emissions is only possible by powering the system with renewable electricity or fossil fuel sources equipped with carbon capture and sequestration.

36 MATERIALS SCIENCE↗

GRIDCERF - Geospatial Raster Input Data for Capacity Expansion Regional Feasibility

The Geospatial Raster Input Data for Capacity Expansion Regional Feasibility (GRIDCERF) data package is a high-resolution product to evaluate siting suitability for renewable and non-renewable power plants in the conterminous United States. GRIDCERF offers hundreds of individual suitability layers for use with both renewable and non-renewable power plant technology configurations in a harmonized format that can be easily ingested by geospatially-enabled modeling software. It also provides pre-compiled technology-specific suitability layers and allows for user customization to robustly address science objectives when evaluating varying future conditions. GRIDCERF data can be directly used with the CERF (Capacity Expansion Regional Feasibility) model to site power plants at a 1km resolution. GRIDCERF includes composite technology siting suitability raster layers for the following utility scale technology configurations. Note that, in addition to technology sub-types shown below, various cooling types are also included (recirculating, pond, once-through, recirculating-seawater, dry-hybrid, or dry) for various technologies. Biomass Conventional (with or without CCS) IGCC (with or without CCS) Coal Conventional (with or without CCS) IGCC (with or without CCS) Natural Gas Combined-cycle (CC) (with or without CCS) Turbine Geothermal Enhanced Geothermal Systems (EGS) - Class 1 through Class 5 resource potential Nuclear Gen 2 Light Water Reactor (LWR) Gen 3 Small Modular Reactor (SMR) Gen 3 AP1000 Refined Liquids Combined-cycle (CC) (with or without CCS) Turbine Solar Photovoltaic (PV) - for capacity factors in the range of 6-18% Utility-scale Concentrating Solar Power (CSP) - for capacity factors in the range of 24-46% Tower Wind (Onshore) - for capacity factors in the range of 5-50% 80m hub height 100m hub height 120m hub height 140m hub height Wind (Offshore) - for capacity factors in the range of 25-60% 100m hub height 140m hub height 160m hub height

capacity expansion↗

GRIDCERF - Geospatial Raster Input Data for Capacity Expansion Regional Feasibility

The Geospatial Raster Input Data for Capacity Expansion Regional Feasibility (GRIDCERF) data package is a high-resolution product to evaluate siting suitability for renewable and non-renewable power plants in the conterminous United States. GRIDCERF offers hundreds of individual suitability layers for use with both renewable and non-renewable power plant technology configurations in a harmonized format that can be easily ingested by geospatially-enabled modeling software. It also provides pre-compiled technology-specific suitability layers and allows for user customization to robustly address science objectives when evaluating varying future conditions. GRIDCERF data can be directly used with the CERF (Capacity Expansion Regional Feasibility) model to site power plants at a 1km resolution. GRIDCERF includes composite technology siting suitability raster layers for the following utility scale technology configurations. Note that, in addition to technology sub-types shown below, various cooling types are also included (recirculating, pond, once-through, recirculating-seawater, dry-hybrid, or dry) for various technologies. Biomass Conventional (with or without CCS) IGCC (with or without CCS) Coal Conventional (with or without CCS) IGCC (with or without CCS) Natural Gas Combined-cycle (CC) (with or without CCS) Turbine Geothermal Enhanced Geothermal Systems (EGS) - Class 1 through Class 5 resource potential Nuclear Gen 2 Light Water Reactor (LWR) Gen 3 Small Modular Reactor (SMR) Gen 3 AP1000 Refined Liquids Combined-cycle (CC) (with or without CCS) Turbine Solar Photovoltaic (PV) - for capacity factors in the range of 6-18% Utility-scale Concentrating Solar Power (CSP) - for capacity factors in the range of 24-46% Tower Wind (Onshore) - for capacity factors in the range of 5-50% 80m hub height 100m hub height 120m hub height 140m hub height Wind (Offshore) - for capacity factors in the range of 25-60% 100m hub height 140m hub height 160m hub height

capacity expansion↗

Phase Transformation Contributions to Heat Capacity and Impact on Thermal Diffusivity, Thermal Conductivity, and Thermoelectric Performance

Abstract The accurate characterization of thermal conductivity κ, particularly at high temperature, is of paramount importance to many materials, thermoelectrics in particular. The ease and access of thermal diffusivity D measurements allows for the calculation of κ when the volumetric heat capacity, ρc p , of the material is known. However, in the relation κ = ρc p D , there is some confusion as to what value of c p should be used in materials undergoing phase transformations. Herein, it is demonstrated that the Dulong–Petit estimate of c p at high temperature is not appropriate for materials having phase transformations with kinetic timescales relevant to thermal transport. In these materials, there is an additional capacity to store heat in the material through the enthalpy of transformation Δ H . This can be described using a generalized model for the total heat capacity for a material where φ is an order parameter that describes how much latent heat responds “instantly” to temperature changes. Here, C pφ is the intrinsic heat capacity (e.g., approximately the Dulong–Petit heat capacity at high temperature). It is shown experimentally in Zn 4 Sb 3 that the decrease in D through the phase transition at 250 K is fully accounted for by the increase in c p , while κ changes smoothly through the phase transition. Consequently, reports of κ dropping near phase transitions in widely studied materials such as PbTe and SnSe have likely overlooked the effects of excess heat capacity and overestimated the thermoelectric efficiency, zT .

Agne, Matthias T.↗

3D Carbon Coating Enabled High‐capacity and Stable Micro‐sized Silicon Suboxide‐graphite Blended Anodes for Practical Lithium‐ion Batteries

Abstract Silicon oxide (SiO x ) is a promising anode candidate of lithium‐ion batteries (LIBs) owing to its extremely high specific capacity. However, the low initial Coulombic efficiency (ICE) and rapid capacity degradation of SiO x , triggered by the enormous volume variation upon repeated (de)lithiation, gravely hinder its practical use. Herein, two mass‐produced micro‐sized SiO x @C composites with obviously different morphologies for commercial LIBs are reported. Particularly, the SiO x ‐graphite blended anode (SiO x @3D‐G‐Gr) based on SiO x wrapped by three‐dimensional (3D) carbon layers (SiO x @3D‐G) exhibits a capacity of 519 mAh g −1 , an ICE of 90.0 % and a capacity retention of 83.4 % at 0.2 C over 100 cycles. which is far exceeding its counterpart SiO x @C‐H‐Gr (65.7 %). The obtained impressive properties of SiO x @3D‐G originate from the critical contribution of 3D carbon layers, which serves as the effective stress buffer and protective layer as well as the strong networks for electron/Li + transport. Accordingly, the full‐cell based on SiO x @3D‐G‐Gr anode and commercial LiCoO 2 cathode delivers a capacity of 803 mAh and an excellent capacity retention of 95.6 % (616 mAh, 96.6 % for graphite, respectively) at 1 C over 100 cycles with a stabilized CE of nearly 100 %. The micro‐sized SiO x @3D‐G showing a promising prospect in the commercial‐grade anodes in LIBs.

Electrochemistry↗

Estimating carrying capacity for juvenile salmon using quantile random forest models

Abstract Establishing robust methods and metrics to evaluate habitat quality is critical for the recovery of endangered Pacific salmonids ( Oncorhynchus spp.). A variety of modeling approaches are used for status and trend monitoring of anadromous species throughout the Pacific Northwest, USA, but current methods may fail to capture the complex relationship between fish and habitat and are often limited in predictive power beyond specific watersheds. Further, the focus on species distribution and abundance is not easily manipulated to predict carrying capacity and traditional stock‐recruitment analyses are reliant on long‐term data which are not always available. In this study, we developed a quantile random forest model to provide estimates of habitat carrying capacity for Chinook salmon ( O. tshawytscha ) parr during the summer months, at both the site and watershed scale. Quantile random forest models allow for the consideration of noisy data, correlated variables, and non‐linear relationships: common features in fish–habitat datasets. We leveraged Columbia Habitat Monitoring Program data to select habitat co‐variates and predict capacity at those sites. We also identified a set of globally available attributes to extrapolate capacity estimate predictions throughout wadeable streams within the Columbia River basin. Total capacity estimates for watersheds closely matched estimates from alternative fish productivity models. Carrying capacity estimates based on quantile random forest models, like those presented here, provide managers a framework to guide the identification, prioritization, and development of habitat rehabilitation actions to recover salmon populations.

See, Kevin E.↗

Oxygen Vacancy Introduction to Increase the Capacity and Voltage Retention in Li‐Excess Cathode Materials

Li‐rich rocksalt oxides are promising cathode materials for lithium‐ion batteries due to their large capacity and energy density, and their ability to use earth‐abundant elements. The excess Li in the rocksalt, needed to achieve good Li transport, reduces the theoretical transition metal redox capacity and introduces a labile oxygen state, both of which lead to increased oxygen oxidation and concomitant capacity loss with cycling. Herein, it is demonstrated that substituting the labile oxygen in Li‐rich cation‐disordered rocksalt materials with a vacancy is an effective strategy to inhibit oxygen oxidation. It is found that the oxygen vacancy in cation‐disordered lithium manganese oxide favors high Li coordination thereby reducing the concentration of unhybridized oxygen states, while increasing the theoretical Mn capacity. It is shown that in the vacancy‐containing compound, synthesized by ball milling, the Mn valence is lowered to less than +3, providing access to more than 300 mAh g −1 capacity from the Mn 2+ /Mn 4+ redox reservoir. The increased transition metal redox and decreased O oxidation are found to improve the capacity and voltage retention, indicating that oxygen vacancy creation to remove the most vulnerable oxygen ions and reduce transition metal valence provides a new opportunity for the design of high‐performance Li‐rich rocksalt cathodes.

25 ENERGY STORAGE↗

Anomalous Behavior of Electronic Heat Capacity of Strongly Correlated Iron Monosilicide

The paper deals with the electronic heat capacity of iron monosilicide FeSi subjected to semiconductor–metal thermal transition during which the formation of its spintronic properties is observed. The proposed model which considers pd-hybridization of strongly correlated d-electrons with non-correlated p-electrons, demonstrates a connection of their contribution to heat capacity in the insulator phase with paramagnon effects and fluctuations of occupation numbers for p- and d-states. In a slitless state, the temperature curve of heat capacity is characterized by a maximum appeared due to normalization of the electron density of states using fluctuating exchange fields. At higher temperatures, a linear growth in heat capacity occurs due to paramagnon effects. The correlation between the model parameters and the first-principles calculation provides the electron contribution to heat capacity, which is obtained from the experimental results on phonon heat capacity. Anharmonicity of phonons is connected merely with the thermal expansion of the crystal lattice.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cationic Effect of Ferrous Ions on Sulfide Capacity of CaO-Fe{sub t}O-Al{sub 2}O{sub 3}-SiO{sub 2} Slag System

The cationic effect of ferrous ions on the sulfide capacity of CaO-Fe{sub t}O-Al{sub 2}O{sub 3}-SiO{sub 2} slags was studied from the viewpoint of the ionic structure in the slag using micro-Raman spectroscopy. In the cation-excess region (M{sup 2+}/2(Fe{sup 3+} + Al{sup 3+}) > 1.0), the sulfide capacity was directly proportional to the basicity of the slags, owing to the S{sup 2−} stabilizing effect of excess cations. However, in the cation-deficient region (M{sup 2+}/2(Fe{sup 3+} + Al{sup 3+}) < 1.0), the sulfide capacity was independent of the basicity of the slags owing to the deficiency of cations required for charge compensation with Al{sup 3+} and Fe{sup 3+}. The cation-substitution effect on the sulfide capacity of the CaO-rich slags (Fe{sub t}O/(Fe{sub t}O + CaO < 0.5) exhibited a linear relationship with the Fe{sup 2+} content because Fe{sup 2+} had a stronger affinity with S{sup 2−} compared to that with Ca{sup 2+}. However, in the Fe{sub t}O-rich slags (Fe{sub t}O/(Fe{sub t}O + CaO > 0.5), the sulfide capacity decreased with the increase of the Fe{sup 2+} content owing to the Q{sup n} unit affinity of the Fe{sup 2+} ion. The sulfide capacity was determined by the competition between the Q{sup n} unit affinity and stability of the S{sup 2−} ion, depending on the type of cation. Therefore, the partial covalent bonding between the M{sup 2+} cations (M: Ca, Fe) and aluminosilicate affected the ionic interactions with the S{sup 2−} ions.

36 MATERIALS SCIENCE↗

Applying design principles to improve hydrogen storage capacity in nanoporous materials

Hydrogen is an attractive option for energy storage because it can be produced from renewable sources and produces environmentally benign byproducts. However, the volumetric energy density of molecular hydrogen at ambient conditions is low compared to other storage methods like batteries, so it must be compressed to attain a viable energy density for applications such as transportation. Nanoporous materials have attracted significant interest for gas storage because they can attain high storage density at lower pressure than conventional compression. Here, we examine how to improve the cryogenic hydrogen storage capacity of a series of porous aromatic frameworks (PAFs) by controlling the pore size and increasing the surface area by adding functional groups. We also explore tradeoffs in gravimetric and volumetric measures of the hydrogen storage capacity and the effects of temperature swings using grand canonical Monte Carlo simulations. We also consider the effects of adding functional groups to the metal–organic framework NU-1000 to improve its hydrogen storage capacity. We find that highly flexible alkane chains do not improve the hydrogen storage capacity in NU-1000 because they do not extend into the pores; however, rigid chains containing alkyne groups do increase the surface area and hydrogen storage capacity. Finally, we demonstrate that the deliverable capacity of hydrogen in NU-1000 can be increased from 40.0 to 45.3 g/L (at storage conditions of 100 bar and 77 K and desorption conditions of 5 bar and 160 K) by adding long, rigid alkyne chains into the pores.

08 HYDROGEN↗

Role of H{sub 2}O{sub 2} on the kinetics of low-affinity high-capacity Na{sup +}-dependent alanine transport in SHR proximal tubular epithelial cells

Research highlights: {yields} H{sub 2}O{sub 2} in excess is required for the presence of a low-affinity high-capacity component for the Na{sup +}-dependent [{sup 14}C]-L-alanine uptake in SHR PTE cells only. {yields} It is suggested that Na{sup +} binding in renal ASCT2 may be regulated by ROS in SHR PTE cells. -- Abstract: The presence of high and low sodium affinity states for the Na{sup +}-dependent [{sup 14}C]-L-alanine uptake in immortalized renal proximal tubular epithelial (PTE) cells was previously reported (Am. J. Physiol. 293 (2007) R538-R547). This study evaluated the role of H{sub 2}O{sub 2} on the Na{sup +}-dependent [{sup 14}C]-L-alanine uptake of ASCT2 in immortalized renal PTE cells from Wistar Kyoto rat (WKY) and spontaneously hypertensive rat (SHR). Na{sup +} dependence of [{sup 14}C]-L-alanine uptake was investigated replacing NaCl with an equimolar concentration of choline chloride in vehicle- and apocynin-treated cells. Na{sup +} removal from the uptake solution abolished transport activity in both WKY and SHR PTE cells. Decreases in H{sub 2}O{sub 2} levels in the extracellular medium significantly reduced Na{sup +}-K{sub m} and V{sub max} values of the low-affinity high-capacity component in SHR PTE cells, with no effect on the high-affinity low-capacity state of the Na{sup +}-dependent [{sup 14}C]-L-alanine uptake. After removal of apocynin from the culture medium, H{sub 2}O{sub 2} levels returned to basal values within 1 to 3 h in both WKY and SHR PTE cells and these were found stable for the next 24 h. Under these experimental conditions, the Na{sup +}-K{sub m} and V{sub max} of the high-affinity low-capacity state were unaffected and the low-affinity high-capacity component remained significantly decreased 1 day but not 4 days after apocynin removal. In conclusion, H{sub 2}O{sub 2} in excess is required for the presence of a low-affinity high-capacity component for the Na{sup +}-dependent [{sup 14}C]-L-alanine uptake in SHR PTE cells only. It is suggested that Na{sup +} binding in renal ASCT2 may be regulated by ROS in SHR PTE cells.

60 APPLIED LIFE SCIENCES↗

Proteins contribute insignificantly to the intrinsic buffering capacity of yeast cytoplasm

Highlights: Black-Right-Pointing-Pointer We predicted buffering capacity of yeast proteome from protein abundance data. Black-Right-Pointing-Pointer We measured total buffering capacity of yeast cytoplasm. Black-Right-Pointing-Pointer We showed that proteins contribute insignificantly to buffering capacity. -- Abstract: Intracellular pH is maintained by a combination of the passive buffering of cytoplasmic dissociable compounds and several active systems. Over the years, a large portion of and possibly most of the cell's intrinsic (i.e., passive non-bicarbonate) buffering effect was attributed to proteins, both in higher organisms and in yeast. This attribution was not surprising, given that the concentration of proteins with multiple protonable/deprotonable groups in the cell exceeds the concentration of free protons by a few orders of magnitude. Using data from both high-throughput experiments and in vitro laboratory experiments, we tested this concept. We assessed the buffering capacity of the yeast proteome using protein abundance data and compared it to our own titration of yeast cytoplasm. We showed that the protein contribution is less than 1% of the total intracellular buffering capacity. As confirmed with NMR measurements, inorganic phosphates play a crucial role in the process. These findings also shed a new light on the role of proteomes in maintaining intracellular pH. The contribution of proteins to the intrinsic buffering capacity is negligible, and proteins might act only as a recipient of signals for changes in pH.

60 APPLIED LIFE SCIENCES↗

Impact of the strength and spatial distribution of adsorption sites on methane deliverable capacity in nanoporous materials

The methane deliverable capacity of adsorbent materials is a critical performance metric that will determine the viability of using adsorbed natural gas (ANG) technology in vehicular applications. ARPA-E recently set a target deliverable capacity of 315 cc(STP)/cc that a viable adsorbent material should achieve to yield a driving range competitive with incumbent fuels. However, recent computational screening of hundreds of thousands of materials suggests that the target is unattainable. In this work, we aim to determine whether the observed limits in deliverable capacity (similar to 200 cc(STP)/cc) are fundamental limits arising from thermodynamic or material design constraints. Our efforts focus on simulating methane adsorption isotherms in a large number of systems, resulting in a broad exploration of different combinations of spatial distributions and energetics of adsorption sites. All systems were classified into five adsorption scenarios with varying degrees of realism in the manner that adsorption sites are created and endowed with energetics. The scenarios range from methane adsorption on discrete idealized lattice sites to adsorption in metal-organic frameworks with coordinatively unsaturated sites (CUS) provided by metalated catechol groups. Our findings strongly suggest that the ARPA-E target is unattainable, although not due to thermodynamic constraints but due to material design constraints. On the other hand, we also find that the currently observed deliverable capacity limits may be moderately surpassed. For instance, incorporation of CUS in IRMOF-10 is predicted to yield a 217 cc(STP)/cc deliverable capacity. The modified material has a similar to 0.85 void fraction and a heat of adsorption of similar to 15 kJ/mol. This suggests that similar, moderate improvements over existing materials could be achieved as long as CUS incorporation still maintains a relatively large void fraction. Nonetheless, we conclude that more significant improvements in deliverable capacity will require changes in the currently proposed operation conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessing electrification readiness in U.S. single-family homes based on a nationwide survey of electrical panel capacities

Electrification of residential buildings is a key strategy for increasing the use of renewable energy sources. Central to this transition is understanding the capacity of existing electrical infrastructure—specifically electrical panels—to safely and effectively manage increased electricity demands from electrification technologies. However, comprehensive nationwide data on electrical panel capacities in U.S. single-family homes is currently lacking. To address this gap, we conducted a nationwide survey of single-family homes, collecting detailed data on electrical panel capacities, breaker slot availability, major electric and gas appliances, electrical panel models, and home characteristics such as construction year and floor area. Photographic documentation was used to verify electrical panel data and appliance information. Results show that approximately 60% of surveyed homes have electrical panels rated at ≥200 amperes (A), indicating that a significant portion of the existing housing stock can accommodate additional electric loads. However, 31% of homes possess panels rated at ≤100 A, potentially restricting their ability to adopt new electric appliances without significant upgrades. Panel capacities positively correlate with both home size and construction year, with newer and larger homes generally better suited for electrification. Homes with higher-capacity panels tend to have fewer gas appliances, reflecting a gradual shift toward electric technologies. Conversely, homes with lower-capacity panels frequently rely on multiple gas appliances, highlighting substantial electrification challenges. Additionally, approximately 3% of surveyed homes had potentially hazardous electrical panel models, emphasizing important safety considerations in the residential electrification process. Our findings underscore the need for targeted policies, financial incentives, and infrastructure investments designed specifically to address infrastructural and safety barriers, particularly in older and smaller homes, to support equitable and efficient electrification across the U.S. residential sector.

Gul, Sadia↗

Heat capacity, enthalpy and entropy of ternary bismuth tantalum oxides

Heat capacity and enthalpy increments of ternary bismuth tantalum oxides Bi{sub 4}Ta{sub 2}O{sub 11}, Bi{sub 7}Ta{sub 3}O{sub 18} and Bi{sub 3}TaO{sub 7} were measured by the relaxation time method (2-280 K), DSC (265-353 K) and drop calorimetry (622-1322 K). Temperature dependencies of the molar heat capacity in the form C{sub pm}=445.8+0.005451T-7.489x10{sup 6}/T{sup 2} J K{sup -1} mol{sup -1}, C{sub pm}=699.0+0.05276T-9.956x10{sup 6}/T{sup 2} J K{sup -1} mol{sup -1} and C{sub pm}=251.6+0.06705T-3.237x10{sup 6}/T{sup 2} J K{sup -1} mol{sup -1} for Bi{sub 3}TaO{sub 7}, Bi{sub 4}Ta{sub 2}O{sub 11} and for Bi{sub 7}Ta{sub 3}O{sub 18}, respectively, were derived by the least-squares method from the experimental data. The molar entropies at 298.15 K, S{sup o}{sub m}(298.15 K)=449.6{+-}2.3 J K{sup -1} mol{sup -1} for Bi{sub 4}Ta{sub 2}O{sub 11}, S{sup o}{sub m}(298.15 K)=743.0{+-}3.8 J K{sup -1} mol{sup -1} for Bi{sub 7}Ta{sub 3}O{sub 18} and S{sup o}{sub m}(298.15 K)=304.3{+-}1.6 J K{sup -1} mol{sup -1} for Bi{sub 3}TaO{sub 7}, were evaluated from the low-temperature heat capacity measurements. -- Graphical Abstract: Temperature dependence of {Delta}{sub ox}C{sub pm} for bismuth tantalum mixed oxides. Display Omitted Research highlights: > Heat capacity, enthalpy and entropy of ternary bismuth tantalum oxides Bi{sub 4}Ta{sub 2}O{sub 11}, Bi{sub 7}Ta{sub 3}O{sub 18} and Bi{sub 3}TaO{sub 7}. > Heat capacity by DSC calorimetry and heat-pulsed calorimetry. > Enthalpy increments by drop calorimetry. > Einstein-Debye model for low-temperature dependence of the heat capacity. > Application of Neumann-Kopp rule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of bearing capacity of axially loaded monopiles based on centrifuge tests

The monopile has been widely used to support offshore and coastal structures. A series of centrifuge tests has been performed to investigate the bearing capacity of large diameter monopiles in sandy soil. Both static tests and cyclic tests have been conducted for open-ended and close-ended model piles, and the effects of influence factors, such as loading rates, embedment depths, and loading histories are considered. The piles are then loaded by a sequence of compressive-tensile loadings to estimate the tension capacity, from which the shaft friction is derived. The cyclic load tests are performed with five varying load intensities, and the accumulated settlement is assessed. The centrifuge tests indicate that the pile bearing capacity tends to increase with the initial penetration depth, and the stress state of soil greatly influences the pile behavior. The tensile shaft friction is smaller compared to the compression test. The capacities of the piles reduce significantly under the axial cyclic load, and the maximum cyclic load intensity should be limited to 75% of the ultimate bearing capacity. The API design method is used to calibrate with the centrifuge test results. The method overestimates the bearing capacity at larger depths, and a conservative reduction factor is required.

17 WIND ENERGY↗