The Development and Hover Test Application of a Projection Moire Interferometry Blade Displacement Measurement System

Projection moir interferometry (PMI) was employed to measure blade deflections during a hover test of a generic model-scale rotor in the NASA Langley 14x22 subsonic wind tunnel s hover facility. PMI was one of several optical measurement techniques tasked to acquire deflection and flow visualization data for a rotor at several distinct heights above a ground plane. Two of the main objectives of this test were to demonstrate that multiple optical measurement techniques can be used simultaneously to acquire data and to identify and address deficiencies in the techniques. Several PMI-specific technical challenges needed to be addressed during the test and in post-processing of the data. These challenges included developing an efficient and accurate calibration method for an extremely large (65 inch) height range; automating the analysis of the large amount of data acquired during the test; and developing a method to determinate the absolute displacement of rotor blades without a required anchor point measurement. The results indicate that the use of a single-camera/single-projector approach for the large height range reduced the accuracy of the PMI system compared to PMI systems designed for smaller height ranges. The lack of the anchor point measurement (due to a technical issue with one of the other measurement techniques) limited the ability of the PMI system to correctly measure blade displacements to only one of the three rotor heights tested. The new calibration technique reduced the data required by 80 percent while new post-processing algorithms successfully automated the process of locating rotor blades in images, determining the blade quarter chord location, and calculating the blade root and blade tip heights above the ground plane.

Sekula, Martin K.↗

SSME Automated Engine Calibrating System (AECS) alternative algorithm

An algorithm is derived for the real-time calibration of the engine mixture ratio during SSME ground testing. Because currently used calibration methods are post-test operations, there exists no fail-safe way of predicting at what mixture ratio a planned test will run. It is proposed that the algorithm developed here be used as part of an AECS which could ensure that nearly all SSME tests are run at the proper mixture ratio. In this way, AECS has the potential of increasing the efficiency of the SSME ground test program. This algorithm is an alternative to that presented in a previous paper. In addition to the derivation of the algorithm, an overview of this calibration system is presented along with a discussion of a possible single coefficient calibration system and the list of test stand facility instrumentation necessary for AECS implementation.

Greene, William D.↗

Hybrid interferometric diagnostic for the refractive index measurement across nearly discrete shock waves

The measurement of high temperature gas properties is key for characterizing high speed flows. Nearly discrete changes in density across shock waves, in particular, are difficult to resolve through traditional fringe-counting interferometric methods. Existing techniques for estimating large fringe jumps are either resolution limited or require specialized window configurations. In this Letter, we describe a unique hybrid interferometric technique that combines narrowband fringes for high resolution and broadband fringes as an absolute reference to measure changes in refractive index with a resolution of up to 7 × 10 −8 across nearly discrete index changes of up to 1.5 × 10 −4 . By capturing fringes with an ultrahigh-speed camera, the refractive index changes across discrete shock fronts can be estimated inside a shock tube with high accuracy and time resolution. First, a novel hybrid calibration method for tracking finite fringes is discussed. Next, this technique is used to measure the post-initial-shock refractive indices for Mach 2.7 to 4.2 flows (pressures from 90.4 to 228.4 kPa). Results are then compared with theoretical values showing agreement within 2%.

Wang, Gwendolyn T. (ORCID:000000016271893X)↗

Comparison and calibration of dose delivered by 137 Cs and x-ray irradiators in mice

Objective. The Office of Radiological Security, U.S. Department of Energy's National Nuclear Security Administration, is implementing a radiological risk reduction program which seeks to minimize or eliminate the use of high activity radiological sources, including 137 Cs, by replacing them with non-radioisotopic technologies, such as x-ray irradiators. The main goal of this paper is to evaluate the equivalence of the dose delivered by gamma- and x-ray irradiators in mice using experimental measurements and Monte Carlo simulations. We also propose a novel biophantom as an in situ dose calibration method. Approach. We irradiated mouse carcasses and 3D-printed mouse biophantoms in a 137 Cs irradiator (Mark I-68) and an x-ray irradiator (X-Rad320) at three voltages (160 kVp, 225 kVp and 320 kVp) and measured the delivered radiation dose. A Geant4-based Monte Carlo model was developed and validated to provide a comprehensive picture of gamma- and x-ray irradiation in mice. Main Results. Our Monte Carlo model predicts a uniform dose delivered in soft-tissue for all the explored irradiation programs and in agreement with the absolute dose measurements. Our Monte Carlo model shows an energy-dependent difference between dose in bone and in soft tissue that decreases as photon energy increases. Dose rate depends on irradiator and photon energy. We observed a deviation of the measured dose from the target value of up to –9% for the Mark I-68, and up to 35% for the X-Rad320. The dose measured in the 3D-printed phantoms are equivalent to that in the carcasses within 6% uncertainty. Significance. Our results suggest that 320 kVp irradiation is a good candidate to substitute 137 Cs irradiation barring a few caveats. There is a significant difference between measured and targeted doses for x-ray irradiation that suggests a strong need for in situ calibration, which can be achieved with 3D-printed mouse biophantoms. A dose correction is necessary for bone doses, which can be provided by a Monte Carlo calculation. Lastly, the biological implications of the differences in dose rates and dose per photon for the different irradiation methods should be carefully assessed for each small-animal irradiation experiment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement and calibration of differential Mueller matrix of distributed targets

A rigorous method for calibrating polarimetric backscatter measurements of distributed targets is presented. By characterizing the radar distortions over the entire mainlobe of the antenna, the differential Mueller matrix is derived from the measured scattering matrices with a high degree of accuracy. It is shown that the radar distortions can be determined by measuring the polarimetric response of a metallic sphere over the main lobe of the antenna. Comparison of results obtained with the new algorithm with the results derived from the old calibration method show that the discrepancy between the two methods is less than 1 dB for the backscattering coefficients. The discrepancy is more drastic for the phase-difference statistics, indicating that removal of the radar distortions from the cross products of the scattering matrix elements cannot be accomplished with the traditional calibration methods.

Sarabandi, Kamal↗

A New Method to Cross Calibrate and Validate TOMS, SBUV/2, and SCIAMACHY Measurements

A unique method to validate back scattered ultraviolet (buv) type satellite data that complements the measurements from existing ground networks is proposed. The method involves comparing the zenith sky radiance measurements from the ground to the nadir radiance measurements taken from space. Since the measurements are compared directly, the proposed method is superior to any other method that involves comparing derived products (for example, ozone), because comparison of derived products involve inversion algorithms which are susceptible to several type of errors. Forward radiative transfer (RT) calculations show that for an aerosol free atmosphere, the ground-based zenith sky radiance measurement and the satellite nadir radiance measurements can be predicted with an accuracy of better than 1 percent. The RT computations also show that for certain values of the solar zenith angles, the radiance comparisons could be better than half a percent. This accuracy is practically independent of ozone amount and aerosols in the atmosphere. Experiences with the Shuttle Solar Backscatter Ultraviolet (SSBUV) program show that the accuracy of the ground-based zenith sky radiance measuring instrument can be maintained at a level of a few tenth of a percent. This implies that the zenith sky radiance measurements can be used to validate Total Ozone Mapping Spectrometer (TOMS), Solar Backscatter Ultraviolet (SBUV/2), and The SCanning Imaging Absorption SpectroMeter for Atmospheric CHartographY (SCIAMACHY) radiance data. Also, this method will help improve the long term precision of the measurements for better trend detection and the accuracy of other BUV products such as tropospheric ozone and aerosols. Finally, in the long term, this method is a good candidate to inter-calibrate and validate long term observations of upcoming operational instruments such as Global Ozone Monitoring Experiment (GOME-2), Ozone Mapping Instrument (OMI), Ozone Dynamics Ultraviolet Spectrometer (ODUS), and Ozone Mapping and Profiler Suite (OMPS).

Ahmad, Ziauddin↗

In situ detection of tropospheric OH, HO2, NO2, and NO by laser-induced fluorescence in detection chambers at reduced pressures

For detection of OH and HO2, we have met or exceeded most of the goals of the proposal for this grant. We have succeeded in building a prototype instrument for the detection of OH and HO2 that has a detection sensitivity of about 2 x 10 exp 4 (OH molecules/cc)/(ct/s), about five times greater than proposed. The current minimum detectable OH of 1.4 x 10 exp 5 OH molecules/cc (S/N=2; 30 second integration) is less than half that proposed, and will be much lower once scattered light levels are reduced. The instrument displays other important properties. First, interfering signals from other gases and OH losses on the inlet appear to be small under laboratory and field conditions. Second, three different calibration methods, two external to the inlet, give similar results, to within 30 percent. Third, the chemical conversion efficiency of HO2 to OH by addition of reagent NO is better than 90 percent. All of these factors give us great confidence that this technique works. The instrument has gone through several variations that have not affected its potential performance but have affected its use. We were able to undergo the first field trials away from State College in June 1992, when we were able to participate informally in the ROSE experiment in rural Alabama, a year ahead of the proposed schedule for field studies. Because this field experiment was our first and the data analysis was complicated by instrument instabilities, we have not yet released the observations. None-the-less, we have gained insight into instrument design. We have not yet completed all of the proposed work. The calibration systems need to be improved to reduce the 50 percent to 100 percent uncertainties to less than 30 percent. Interference signals from ambient gases and possible losses on the inlet under field conditions need to be quantified. Finally, the detection of NO2 and NO with laser induced fluorescence is only now being seriously pursued.

Brune, William H.↗

Calibration verification for stochastic agent-based disease spread models

Accurate disease spread modeling is crucial for identifying the severity of outbreaks and planning effective mitigation efforts. To be reliable when applied to new outbreaks, model calibration techniques must be robust. However, current methods frequently forgo calibration verification (a stand-alone process evaluating the calibration procedure) and instead use overall model validation (a process comparing calibrated model results to data) to check calibration processes, which may conceal errors in calibration. In this work, we develop a stochastic agent-based disease spread model to act as a testing environment as we test two calibration methods using simulation-based calibration, which is a synthetic data calibration verification method. The first calibration method is a Bayesian inference approach using an empirically-constructed likelihood and Markov chain Monte Carlo (MCMC) sampling, while the second method is a likelihood-free approach using approximate Bayesian computation (ABC). Simulation-based calibration suggests that there are challenges with the empirical likelihood calculation used in the first calibration method in this context. These issues are alleviated in the ABC approach. Despite these challenges, we note that the first calibration method performs well in a synthetic data model validation test similar to those common in disease spread modeling literature. We conclude that stand-alone calibration verification using synthetic data may benefit epidemiological researchers in identifying model calibration challenges that may be difficult to identify with other commonly used model validation techniques.

60 APPLIED LIFE SCIENCES↗

Toward Improved Regional Hydrological Model Performance Using State-Of-The-Science Data-Informed Soil Parameters

Accurate soil moisture and streamflow data are an aspirational need of many hydrologically relevant fields. Model simulated soil moisture and streamflow hold promise but models require validation prior to application. Calibration methods are commonly used to improve model fidelity but misrepresentation of the true dynamics remains a challenge. In this study, we leverage soil parameter estimates from the Soil Survey Geographic (SSURGO) database and the probability mapping of SSURGO (POLARIS) to improve the representation of hydrologic processes in the Weather Research and Forecasting Hydrological modeling system (WRF-Hydro) over a central California domain. Our results show WRF-Hydro soil moisture exhibits increased correlation coefficients ( r ), reduced biases, and increased Kling-Gupta Efficiencies (KGEs) across seven in situ soil moisture observing stations after updating the model's soil parameters according to POLARIS. Compared to four well-established soil moisture data sets including Soil Moisture Active Passive data and three Phase 2 North American Land Data Assimilation System land surface models, our POLARIS-adjusted WRF-Hydro simulations produce the highest mean KGE (0.69) across the seven stations. More importantly, WRF-Hydro streamflow fidelity also increases, especially in the case where the model domain is set up with SSURGO-informed total soil thickness. The magnitude and timing of peak flow events are better captured, r increases across nine United States Geological Survey stream gages, and the mean KGE across seven of the nine gages increases from 0.12 to 0.66. Our pre-calibration parameter estimate approach, which is transferable to other spatially distributed hydrological models, can substantially improve a model's performance, helping reduce calibration efforts and computational costs.

54 ENVIRONMENTAL SCIENCES↗

Comparison of CERES-MODIS Stratus Cloud Properties with Ground-Based Measurements at the DOE ARM Southern Great Plains Site

Overcast stratus cloud properties derived for the Clouds and the Earth's Radiant Energy system (CERES) Project using Terra and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) data are compared with observations taken at the Atmospheric Radiation Measurement (ARM) Southern Great Plains site from March 2000 through December 2004. Retrievals from ARM surface-based data were averaged over a 1-hour interval centered at the time of each satellite overpass, and the CERES-MODIS cloud properties were averaged within a 30-km x 30 km box centered on the ARM SGP site. Two datasets were analyzed: all of the data (ALL) which include multilayered, single-layered, and slightly broken stratus decks and a subset, single-layered unbroken decks (SL). The CERES-MODIS effective cloud heights were determined from effective cloud temperature using a lapse rate method with the surface temperature specified as the 24-h mean surface air temperature. For SL stratus, they are, on average, within the ARM radar-lidar estimated cloud boundaries and are 0.534 +/- 0.542 km and 0.108 +/- 0.480 km lower than the cloud physical tops and centers, respectively, and are comparable for day and night observations. The mean differences and standard deviations are slightly larger for ALL data, but not statistically different to those of SL data. The MODIS-derived effective cloud temperatures are 2.7 +/- 2.4 K less than the surface-observed SL cloud center temperatures with very high correlations (0.86-0.97). Variations in the height differences are mainly caused by uncertainties in the surface air temperatures, lapse rates, and cloud-top height variability. The biases are mainly the result of the differences between effective and physical cloud top, which are governed by cloud liquid water content and viewing zenith angle, and the selected lapse rate, -7.1 K km(exp -1). Based on a total of 43 samples, the means and standard deviations of the differences between the daytime Terra and surface retrievals of effective radius r(sub e), optical depth, and liquid water path for SL stratu are 0.1 +/- 1.9 micrometers (1.2 +/- 23.5%), -1.3 +/- 9.5 (-3.6 +/-26.2%), and 0.6 +/- 49.9 gm (exp -2) (0.3 +/- 27%), respectively, while the corresponding correlation coefficients are 0.44, 0.87, and 0.89. For Aqua, they are 0.2 +/- 1.9 micrometers (2.5 +/- 23.4%), 2.5 +/- 7.8 (7.8 +/- 24.3%), and 28.1 +/- 52.7 gm (exp -2) (17.2 +/- 32.2%), as well as 0.35, 0.96, and 0.93 from a total of 21 cases. The results for ALL cases are comparable. Although a bias in R(sub e) was expected because the satellite retrieval of effective radius only represents the top of the cloud, the surface-based radar retrievals revealed that the vertical profile of r(sub e) is highly variable with smaller droplets occurring at cloud top in some cases. The larger bias in optical depth and liquid water path for Aqua is due, at least partially, to differences in the Terra and Aqua MODIS visible channel calibrations. methods for improving the cloud-top height and microphysical property retrievals are suggested.

Dong, Xiquan↗

Simulation, Challenge Testing and Validation of Solutions for Residential and Commercial Occupancy Sensing/Counting and CO2 Sensing (Final Report)

Carbon dioxide sensors used for monitoring and control applications in buildings are known to be sensitive to long term drift and can be affected by variations in temperature, humidity, other gas interferents, pressure and other factors that cannot be corrected through the typical auto-calibration methods often embedded in the sensor electronics. This investigation was part of the Category D defined in the ARPA-E Saving Energy Nationwide in Structures With Occupancy Recognition (SENSOR) Financial Assistance Funding Opportunity Announcement No. DE-FOA-0001737, FFDA No. 81.135, January 18, 2017. The FOA defined target criteria for the evaluation of the Category C commercial CO2 sensors selected for review and development through the ARPA-E SENSOR program and charged the Iowa State Category D team with developing an evaluation methodology for Category C sensors in accordance with these criteria. As part of the work, the Iowa State team chose to engage the standards community in the development of the evaluation methodology. Standard development work in the D22.05 Indoor Air and D22.03 Ambient Atmospheres and Source Emissions subcommittees of ASTM International Committee D22 on Air Quality on the evaluation of low cost sensors and provision of guidance for using indoor carbon dioxide concentrations to evaluate indoor air quality and ventilation is of particular relevance to the Category D efforts. To date, three draft standards with specific input by the Iowa State Category D team have passed the subcommittee balloting stage and are being balloted in December 2022 and January 2023 in the main D22 committee. In addition to the aforementioned standards to which the PI was a contributing author, intellectual property developed in this project pertaining to “An Automated System for Evaluation of the Long Term Performance of Carbon Dioxide Sensors” and “An Automated Ground Truth System for Real-Time Reliability Assessment, Capture of Control Decisions and Energy Savings Measurements for Occupancy Recognition Systems and Other Applications” are the other major deliverables of the project. These standards and the developed intellectual property are expected to benefit the public in a number of ways stemming from their provision of means to benchmark the performance of carbon dioxide and other sensor systems. In particular, there is high interest in techniques to demonstrate the performance of low-cost carbon dioxide sensors which can be used for typical HVAC applications (e.g., demand controlled ventilation, outdoor and indoor air monitoring, estimation of occupancy, etc.).

42 ENGINEERING↗

Lightning radiometry in visible and infrared bands

Calibrated measurements of lightning optical emissions are critical for both quantifying the impacts of lightning in our atmosphere and devising detection instruments with sufficient dynamic range capable of yielding close to 100% detection efficiency. However, to date, there is only a limited number of investigations that have attempted to take such calibrated measurements. Here, in this work, we report the power radiated by lightning in both visible and infrared bands, assuming isotropic emission, and accounting for atmospheric absorption. More precisely, we report peak radiated power and total radiated energy in the combined visible plus near-infrared range (VNIR, 0.34–1.1 μm), around the H α line (652–667 nm), and for the 2–2.5 μm infrared band. The estimated peak power and total energy radiated by negative cloud-to-ground return strokes in the VNIR range is 130 MW and 20 kJ, respectively. Additionally, we detected peak radiated powers of 12 and 0.19 MW in the H α and infrared bands, respectively. We cross-reference the optical data set with peak current reported by a lightning detection network. The resulting trend is that optical power emitted around the H α line scales with peak return stroke current according to a power law with exponent equal to 1.25. This trend, which should be approximately true across the entire visible spectrum, can be attributed to the plasma negative differential resistance of the lightning return stroke channel. We conclude by discussing the challenges in performing calibrated measurements of lightning optical power in different bands and comparing the results with previously-collected data with different experimental setups, observation conditions, and calibration methods.

54 ENVIRONMENTAL SCIENCES↗

A predictive discrete-continuum multiscale model of plasticity with quantified uncertainty

Multiscale models of materials, consisting of upscaling discrete simulations to continuum models, are unique in their capability to simulate complex materials behavior. The fundamental limitation in multiscale models is the presence of uncertainty in the computational predictions delivered by them. In this work, a sequential multiscale model has been developed, incorporating discrete dislocation dynamics (DDD) simulations and a strain gradient plasticity (SGP) model to predict the size effect in plastic deformations of metallic micro-pillars. The DDD simulations include uniaxial compression of micro-pillars with different sizes and over a wide range of initial dislocation densities and spatial distributions of dislocations. An SGP model is employed at the continuum level that accounts for the size-dependency of flow stress and hardening rate. Sequences of uncertainty analyses have been performed to assess the predictive capability of the multiscale model. The variance-based global sensitivity analysis determines the effect of parameter uncertainty on the SGP model prediction. The multiscale model is then constructed by calibrating the continuum model using the data furnished by the DDD simulations. A Bayesian calibration method is implemented to quantify the uncertainty due to microstructural randomness in discrete dislocation simulations (density and spatial distribution of dislocations) on the macroscopic continuum model prediction (size effect in plastic deformation). Here, the outcomes of this study indicate that the discrete-continuum multiscale model can accurately simulate the plastic deformation of micro-pillars, despite the significant uncertainty in the DDD results. Additionally, depending on the macroscopic features represented by the DDD simulations, the SGP model can reliably predict the size effect in plasticity responses of the micropillars with below 10% of error.

36 MATERIALS SCIENCE↗

The CLAS12 drift chamber system

The CEBAF Large Acceptance Spectrometer at 12~GeV (CLAS12) is located in Hall~B, one of the experimental halls at Jefferson Lab. The forward part of CLAS12 is built around a superconducting toroidal magnet. The six coils of the toroid divide the detector azimuthally into six sectors. Each sector contains three multi-layer drift chambers for reconstructing the trajectories of charged particles originating from a fixed target. Each of the 18 planar chambers has two ``superlayers'' of six layers each, with the wires in the two adjacent superlayers oriented at ± 6° stereo angles. Each layer has 112 hexagonal cells spanning a range from about 5° to 40° in polar angle. The six-layer structure provides redundancy in track segment finding and good tracking efficiency even in the presence of some individual wire inefficiency. The design, construction, operation, and calibration methods are described, and estimates of the efficiency and resolution are presented from in-beam measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Representing Global Soil Erosion and Sediment Flux in Earth System Models

Abstract Soil erosion produces enormous amounts of sediment, carbon, and nutrient fluxes from land to rivers, thus playing crucial roles in global biogeochemical cycles and food security. To predict soil erosion in the context of climate and land use changes, we explicitly parameterize cropland management actions (i.e., irrigation, conserved agriculture, and crop residue management) and geological factors (i.e., lithology and glacier) in the Energy Exascale Earth System Model (E3SM) soil erosion module. The erosion model is calibrated using a global‐scale regionalized parameter calibration method. The spatial variabilities of the modeled and the Revised Universal Soil Loss Equation (RUSLE) based benchmark soil erosion are consistent across vegetation, climate and soil properties. Compared with independent data, our model shows a bias reduction in 59% of the observations relative to the RUSLE‐based soil erosion, with 53% of the bias reduction exceeding 50%. This improvement is mainly due to a better representation of the topographic effect on soil erosion. Our results indicate that conserved agriculture practices have effectively reduced soil erosion in cropland by over 25% in the United States and Argentina. In contrast, irrigation has increased soil erosion in many Asian countries. For upland sediment flux, our model is consistent with the WBMsed benchmark data in inter‐basin variability but could be more skillful in simulating intra‐basin variability because it couples soil erosion and sediment flux explicitly. The developed model provides useful skills for more realistic predictions of soil erosion and river sediment dynamics under environmental changes.

58 GEOSCIENCES↗

Ground far-red sun-induced chlorophyll fluorescence and vegetation indices in the US Midwestern agroecosystems

Abstract Sun-induced chlorophyll fluorescence (SIF) provides an opportunity to study terrestrial ecosystem photosynthesis dynamics. However, the current coarse spatiotemporal satellite SIF products are challenging for mechanistic interpretations of SIF signals. Long-term ground SIF and vegetation indices (VIs) are important for satellite SIF validation and mechanistic understanding of the relationship between SIF and photosynthesis when combined with leaf- and canopy-level auxiliary measurements. In this study, we present and analyze a total of 15 site-years of ground far-red SIF (SIF at 760 nm, SIF 760 ) and VIs datasets from soybean, corn, and miscanthus grown in the U.S. Corn Belt from 2016 to 2021. We introduce a comprehensive data processing protocol, including different retrieval methods, calibration coefficient adjustment, and nadir SIF footprint upscaling to match the eddy covariance footprint. This long-term ground far-red SIF and VIs dataset provides important and first-hand data for far-red SIF interpretation and understanding the mechanistic relationship between far-red SIF and canopy photosynthesis across various crop species and environmental conditions.

59 BASIC BIOLOGICAL SCIENCES↗

J-PLUS: Systematic impact of metallicity on photometric calibration with the stellar locus

Here, we present the photometric calibration of the twelve optical passbands for the Javalambre Photometric Local Universe Survey (J-PLUS) second data release (DR2), comprising 1088 pointings of two square degrees, and study the systematic impact of metallicity on the stellar locus technique. The [Fe/H] metallicity from the Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST) for 146 184 high-quality calibration stars, defined with signal-to-noise ratio larger than ten in J-PLUS passbands and larger than three in Gaia parallax, was used to compute the metallicity-dependent stellar locus (ZSL). The initial homogenization of J-PLUS photometry, performed with a unique stellar locus, was refined by including the metallicity effect in colors via the ZSL. The variation of the average metallicity along the Milky Way produces a systematic offset in J-PLUS calibration. This effect is well above 1% for the bluer passbands and amounts 0.07, 0.07, 0.05, 0.03, and 0.02 mag in u, J0378, J0395, J0410, and J0430, respectively. We modeled this effect with the Milky Way location of the J-PLUS pointing, also providing an updated calibration for those observations without LAMOST information. The estimated accuracy in the calibration after including the metallicity effect is at 1% for the bluer J-PLUS passbands and below for the rest. Photometric calibration with the stellar locus technique is prone to significant systematic bias in the Milky Way for passbands bluer than λ = 4500 Å. The calibration method for J-PLUS DR2 reaches 1–2% precision and 1% accuracy for 12 optical filters within an area of 2176 square degrees.

79 ASTRONOMY AND ASTROPHYSICS↗

Alternatives to NIST Cf-252 Iirradiations for Transfer Calibration of S-32 Neutron Monitors

Gas-flow proportional counting systems are used by the Radiation Metrology Laboratory (RML) at Sandia National Laboratories for reactor fluence monitoring with the 32 S(n,p) 32 P reaction. Calibration of these systems has traditionally been accomplished by fluence-transfer irradiations at the NIST 252 Cf facility. Such calibrations have become increasingly difficult as the NIST 252 Cf source decayed to unusable levels. To minimize the risk to the testing programs from an inability to properly calibrate these systems, the RML has developed two alternative calibration techniques: 1) development and implementation of certified 32 P sources for activity calibrations and subsequent calculation of neutron fluence, and 2) direct counting of non-certified reactor-irradiated sulfur pellets by liquid scintillation counting to determine 32 P activity for the subsequent calibration of gas-flow proportional counters. Preliminary comparisons show that the several calibration methods are capable of overall uncertainties within about 5 percent.

Vehar, David W.↗