Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibrated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Automatic Échelle Spectrograph Wavelength Calibration

Time-domain astronomy and the increasing number of exoplanet candidates call for reliable, robust, and automatic wavelength calibration. We present an algorithm for wavelength-calibrating échelle spectrographs that uses order-by-order extracted spectra and a list of laboratory wavelengths. Our approach is fully automatic and does not need the pixel locations of certain spectral features with which to anchor the wavelength solution, nor the true order number of each diffraction order. We use spectral features that are duplicated in adjacent orders to establish the scale-invariant component of the wavelength solution. We then match the central wavelengths of spectral features to laboratory wavelengths to establish the scale and higher-order components of the wavelength solution. We demonstrate our method on the four spectrographs of Las Cumbres Observatory’s Network of Robotic Échelle Spectrographs (NRES), on the High Accuracy Radial Velocity Planet Searcher (HARPS) spectrograph, and on synthetic data. We obtain a velocity-equivalent precision of ∼10 m s{sup −1} on NRES. We achieve ∼1 m s{sup −1} on HARPS, which agrees with the precision reported by the HARPS team. On synthetic data, we achieve the velocity precision set by Gaussian centroiding errors. Our algorithm likely holds for a wide range of spectrographs beyond the five presented here. We provide an open-source Python package, xwavecal, which outputs wavelength-calibrated spectra as well as the wavelengths of spectral features.

79 ASTRONOMY AND ASTROPHYSICS↗

A D-term Modeling Code (DMC) for Simultaneous Calibration and Full-Stokes Imaging of Very Long Baseline Interferometric Data

In this paper we present DMC, a model and associated tool for polarimetric imaging of very long baseline interferometry data sets that simultaneously reconstructs the full-Stokes emission structure along with the station-based gain and leakage calibration terms. DMC formulates the imaging problem in terms of posterior exploration, which is achieved using Hamiltonian Monte Carlo sampling. The resulting posterior distribution provides a natural quantification of uncertainty in both the image structure and the data calibration. We run DMC on both synthetic and real data sets, the results of which demonstrate its ability to accurately recover both the image structure and calibration quantities, as well as to assess their corresponding uncertainties. The framework underpinning DMC is flexible, and its specific implementation is under continued development.

47 OTHER INSTRUMENTATION↗

Calibration of the Hα Age–Activity Relation for M Dwarfs

In this work, we calibrate the relationship between Hα emission and M dwarf ages. We compile a sample of 892 M dwarfs with Hα equivalent width (Hα EW) measurements from the literature that are either comoving with a white dwarf of known age (21 stars) or in a known young association (871 stars). In this sample we identify 7 M dwarfs that are new candidate members of known associations. By dividing the stars into active and inactive categories according to their Hα EW and spectral type (SpT), we find that the fraction of active dwarfs decreases with increasing age, and the form of the decline depends on SpT. Using the compiled sample of age calibrators, we find that Hα EW and fractional Hα luminosity (L {sub Hα}/L {sub bol}) decrease with increasing age. Hα EW for SpT ≤ M7 decreases gradually up until ∼1 Gyr. For older ages, we found only two early M dwarfs that are both inactive and seem to continue the gradual decrease. We also found 14 mid-type M dwarfs, out of which 11 are inactive and present a significant decrease in Hα EW, suggesting that the magnetic activity decreases rapidly after ∼1 Gyr. We fit L {sub Hα}/L {sub bol} versus age with a broken power law and find an index of −0.11{sub −0.01}{sup +0.02} for ages ≲776 Myr. The index becomes much steeper at older ages, but a lack of field age-calibrators (≫1 Gyr) leaves this part of the relation far less constrained. Finally, from repeated independent measurements for the same stars, we find that 94% of them have a level of Hα EW variability ≤5 Å at young ages (<1 Gyr).

79 ASTRONOMY AND ASTROPHYSICS↗

Using an Absolute Cavity Pyrgeometer to Validate the Calibration of a Secondary Standard Pyrgeometer Outdoors, Independent from the Reference Value of the Atmospheric Longwave Irradiance

Accurate measurements of broadband outdoor longwave irradiance are important for renewable energy applications and the study of the atmosphere and climate change. A unique method of pyrgeometer calibration has been developed to improve the measurement uncertainty [1]. The results of this method yielded irradiance values within ±3 W/m 2 of those traceable to the World InfraRed Standard Group (WISG). This article describes a technique for validating this pyrgeometer calibration method using two Absolute Cavity Pyrgeometers (ACPs). The ACPs and pyrgeometer model PIR were deployed outdoors and the irradiance measured by the PIR was compared against the average irradiance measured by the two ACPs. The irradiance measured by the PIR was calculated using two equations, NREL equation and the Physikalisch Meteorologisches Observatorium Davos (PMOD) equation. The uncertainty with 95% confidence level ( U 95 ) of the irradiance measured by the PIR using NREL equation equaled ±3.51 W/m 2 with respect to SI and using PMOD equation U 95 equaled ±2.99 W/m 2 with respect to SI. These results suggest that the PIR calibration method might be useful in addressing the international need for a secondary standard pyrgeometer traceable to SI.

54 ENVIRONMENTAL SCIENCES↗

Verification, Validation, and Calibration Through a Causal Lens

While typical validation and verification approaches focus on identifying the associations between data elements using statistical and machine learning methods, the novel methods in this paper focus instead on identifying causal relationships between data elements. Statistical and machine-learning-based approaches are strictly data-driven, meaning that they provide quantitative comparison measures between data sets without explicitly considering the hypotheses behind them. This can lead to the erroneous conclusion that, if two data sets are close enough, the models that generated them are similar. In addition, when experimental and simulated data differ to an extent that fails to meet the acceptance criteria, calibration techniques are used to tweak simulation model parameters to reduce the gap between the two types of data. This produces the false expectation that a simulation model will match reality. The methods presented in this paper move away from these strictly data-driven methods for validation and calibration toward more robust, model-driven methods based on causal inference. Causal inference aims to identify the possible mechanisms that might have generated data. Thus, this analysis targets the prediction of the effects when one (or more) of the identified mechanisms are altered. There are many approaches to identify, quantify, and illustrate causal relationships. For the scope of this paper, directed graphs are employed as causal models. If the directed graph lacks cycles, it is known as a directed acyclic graph. A node in such a graph represents an observed data element while a directed edge connecting two nodes represents a causal relationship between two variables. The developed causal methods are designed to extract causal models from simulation models and experimental data. Causal models capture the causal relationships between data elements (e.g., simulated and experimental data). In this context, validation and verification are performed by comparing causal models. The proposed approach does not only inform system analysts on how a simulation model matches real-world data, but also identifies elements of the simulation model that should be revised when discrepancies between simulation and experimental data are observed. Through these causal methods, analysts can identify the portion of the model equation(s) that are behind an edge connecting two variables. Hence, once the structural differences between causal models have been determined, model calibration can occur by changing only those model parameters that impact the identified causal relationships.

97 MATHEMATICS AND COMPUTING↗

Calibration of the Solid‐State Nuclear Magnetic Resonance Search for Axion‐Like Dark Matter

Abstract Calibration of nuclear‐magnetic‐resonance‐based searches for axion‐like dark matter can be performed by free induction decay (FID) measurements. This manu‐ script describes FID experiments on several solid materials, motivated by the Cosmic Axion Spin Precession Experiment (CASPEr) program. Experiments with 207 Pb nuclear spins in ferroelectrics, lead magnesium niobate‐lead titanate (PbMg 1/3 Nb 2/3 O 3 ) (PbTiO 3 ) 1/3 (PMN‐PT) and lead zirconium titante PbZr 0.52 Ti 0.48 O 3 (PZT) are directly relevant to the CASPEr‐electric search for the electric dipole moment interaction of axion‐like dark matter. Experiments with 31 P nuclear spins in gadolinium‐doped hydroxypyromorphite Pb 4.95 Gd 0.05 (PO 4 ) 3 OH (HPM:Gd) are used for apparatus calibration. The measurements characterized the nuclear spin ensemble coherence time and the magnetic resonance detection sensitivity for these samples. Calibration is performed using small tip‐angle pulses.

Winter, Andrew J.↗

Bayesian calibration of strength model parameters from Taylor impact data

Materials strength plays a key role in determining the mechanical response of engineered structures. As such, accurate strength models are crucial in simulations involving complex loading conditions, particularly when deformation in the plastic regime is deemed important. In this work, a Gaussian process based surrogate for a finite element simulation of a Taylor impact test is developed and used for Bayesian calibration of the Preston–Tonks–Wallace strength model. Here, the surrogate model is shown to closely approximate the salient features of the Taylor cylinder deformation and is validated against simulation output before being used in the strength model calibration routine. The results show that Taylor impact test data can be used in the calibration of constitutive equations through the use of a combination of data science techniques, namely Gaussian processes and Bayesian inference.

36 MATERIALS SCIENCE↗

Calibration of a compact ASIC-based data acquisition system for neutron/$γ$ discrimination and spectroscopy with organic scintillators

Segmented neutron detectors that use silicon photomultipliers (SiPMs) are receiving significant attention in nuclear security applications. Some of these detectors employ hundreds of channels and would therefore benefit from the use of high-channel-density and low-cost-per-channel data acquisition (DAQ) systems. Candidate DAQ systems that meet these requirements exist, but few perform full waveform digitization, which permits neutron and gamma-ray interaction discrimination via pulse shape. In this work, we study the performance of the TOFPET2 (PETsys Electronics), an ASIC-based DAQ designed for positron emission tomography, which has been adapted to provide sensitivity to pulse shape by the use of variable-period charge integration. We use a light-emitting diode to calibrate a combination of an ON Semiconductor (SensL) 60035-64P J-Series SiPM and TOPFET2 DAQ and evaluate the linearity of their response and dynamic range. Here, the calibration curve was obtained by comparing the DAQ response to that measured with a photodiode interfaced with a traditional waveform digitizer. This calibration process was used for rudimentary spectroscopy of various neutron and sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model calibration of the liquid mercury spallation target using evolutionary neural networks and sparse polynomial expansions

The mercury constitutive model predicting the strain and stress in the target vessel plays a central role in improving the lifetime prediction and future target designs of the mercury targets at the Spallation Neutron Source. We leverage the experiment strain data collected over multiple years to improve the mercury constitutive model through a combination of large scale simulations of the target behavior and the use of machine learning tools for parameter estimation. We present two interdisciplinary approaches for surrogate-based model calibration of expensive simulations using evolutionary neural networks and sparse polynomial expansions. The newly calibrated simulations achieve 7% average improvement on the prediction accuracy and 8% reduction in mean absolute error compared to previously reported reference parameters, with some individual sensors experiencing up to 30% improvement. The calibrated simulations can aid in fatigue analysis to estimate the mercury target lifetime, which reduces abrupt failure and saves tremendous amount of costs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Amundsen Sea Embayment ice-sheet mass-loss predictions to 2050 calibrated using observations of velocity and elevation change

Mass loss from the Amundsen Sea Embayment of the West Antarctic Ice Sheet is a major contributor to global sea-level rise (SLR) and has been increasing over recent decades. Predictions of future SLR are increasingly modelled using ensembles of simulations within which model parameters and external forcings are varied within credible ranges. Accurately reporting the uncertainty associated with these predictions is crucial in enabling effective planning for, and construction of defences against, rising sea levels. Calibrating model simulations against current observations of ice-sheet behaviour enables the uncertainty to be reduced. Here we calibrate an ensemble of BISICLES ice-sheet model simulations of ice loss from the Amundsen Sea Embayment using remotely sensed observations of surface elevation and ice speed. Each calibration type is shown to be capable of reducing the 90% credibility bounds of predicted contributions to SLR by 34 and 43% respectively.

54 ENVIRONMENTAL SCIENCES↗

Timing Calibration and Windowing Technique Comparison for Lightning Mapping Arrays

Abstract Since their introduction 22 years ago, lightning mapping arrays (LMA) have played a central role in the investigation of lightning physics. Even in recent years with the proliferation of digital interferometers and the introduction of the LOw Frequency ARray (LOFAR) radio telescope, LMAs still play an important role in lightning science. LMA networks use a simple windowing technique that records the highest pulse in either 80 μs or 10 μs fixed windows in order to apply a time‐of‐arrival location technique. In this work, we develop an LMA‐emulator that uses lightning data recorded by LOFAR to simulate an LMA, and we use it to test three new styles of pulse windowing. We show that they produce very similar results as the more traditional LMA windowing, implying that LMA lightning mapping results are relatively independent of windowing technique. In addition, each LMA station has its GPS‐conditioned clock. While the timing accuracy of GPS receivers has improved significantly over the years, they still significantly limit the timing measurements of the LMA. Recently, new time‐of‐arrival techniques have been introduced that can be used to self‐calibrate systematic offsets between different receiving stations. Applying this calibration technique to a set of data with 32 ns uncertainty, observed by the Colorado LMA, improves the timing uncertainty to 19 ns. This technique is not limited to LMAs and could be used to help calibrate future multi‐station lightning interferometers.

Hare, Brian M.↗

Calibration and Initial Results of Space Radiation Dosimetry Using the iMESA-R

The integrated Miniaturized Electrostatic Analyzer-Reflight (iMESA-R) is a space weather instrument designed to measure plasma density, temperature, and spacecraft charging, along with total ionizing dose and dose rate. A constellation consisting of five nearly identical instruments has been designed and developed to act as science payloads hosted on-board Department of Defense satellites operating in low-Earth orbit. To validate the dosimetry component of the iMESA-R, a radiation test study was performed to calibrate the dosimeter and ascertain the attenuation due to the instrument aluminum housing. An 80 curie Cobalt-60 radioisotope source emitting beta, X-ray, and gamma ray radiation decay products was used to calibrate the dosimeter response as a function of distance and instrument shielding. We present results of the calibration study along with initial on-orbit data presented from the first operational iMESA-R hosted on-board Space Test Program Satellite 5 in a polar Earth orbit. The initial on-orbit data demonstrate the ability to map the radiation environment, particularly the South Atlantic Anomaly and the auroral regions using total ionizing dose rate due to electrons of E > 1.5 MeV and protons of E > 25 MeV.

79 ASTRONOMY AND ASTROPHYSICS↗

From calibration to parameter learning: Harnessing the scaling effects of big data in geoscientific modeling

Abstract The behaviors and skills of models in many geosciences (e.g., hydrology and ecosystem sciences) strongly depend on spatially-varying parameters that need calibration. A well-calibrated model can reasonably propagate information from observations to unobserved variables via model physics, but traditional calibration is highly inefficient and results in non-unique solutions. Here we propose a novel differentiable parameter learning (dPL) framework that efficiently learns a global mapping between inputs (and optionally responses) and parameters. Crucially, dPL exhibits beneficial scaling curves not previously demonstrated to geoscientists: as training data increases, dPL achieves better performance, more physical coherence, and better generalizability (across space and uncalibrated variables), all with orders-of-magnitude lower computational cost. We demonstrate examples that learned from soil moisture and streamflow, where dPL drastically outperformed existing evolutionary and regionalization methods, or required only ~12.5% of the training data to achieve similar performance. The generic scheme promotes the integration of deep learning and process-based models, without mandating reimplementation.

54 ENVIRONMENTAL SCIENCES↗

Training calibration-based counterfactual explainers for deep learning models in medical image analysis

The rapid adoption of artificial intelligence methods in healthcare is coupled with the critical need for techniques to rigorously introspect models and thereby ensure that they behave reliably. This has led to the design of explainable AI techniques that uncover the relationships between discernible data signatures and model predictions. In this context, counterfactual explanations that synthesize small, interpretable changes to a given query while producing desired changes in model predictions have become popular. This under-constrained, inverse problem is vulnerable to introducing irrelevant feature manipulations, particularly when the model’s predictions are not well-calibrated. Hence, in this paper, we propose the TraCE (training calibration-based explainers) technique, which utilizes a novel uncertainty-based interval calibration strategy for reliably synthesizing counterfactuals. Given the wide-spread adoption of machine-learned solutions in radiology, our study focuses on deep models used for identifying anomalies in chest X-ray images. Using rigorous empirical studies, we demonstrate the superiority of TraCE explanations over several state-of-the-art baseline approaches, in terms of several widely adopted evaluation metrics. Our findings show that TraCE can be used to obtain a holistic understanding of deep models by enabling progressive exploration of decision boundaries, to detect shortcuts, and to infer relationships between patient attributes and disease severity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calibration of a versatile multi-energy soft x-ray diagnostic for WEST long pulse plasmas

A compact multi-energy soft x-ray diagnostic is being installed on the W Environment in Steady-state Tokamak (WEST), which was designed and built to test ITER-like tungsten plasma facing components in a long pulse (~1000 s) scenario. The diagnostic consists of a pinhole camera fielded with the PILATUS3 photon-counting Si-based detector (≲100 kpixel). The detector has sensitivity in the range 1.6–30 keV and enables energy discrimination, providing a higher energy resolution than conventional systems with metal foils and diodes with adequate space and time resolution (≲1 cm and 2 ms). The lower-absorption cut-off energy is set independently on each one of the ~100 kpixels, providing a unique opportunity to measure simultaneously the plasma emissivity in multiple energy ranges and deduce a variety of plasma parameters (e.g., T e , n Z , and ΔZ eff ). The energy dependence of each pixel is calibrated here over the range 3–22 keV. The detector is exposed to a variety of monochromatic sources—fluorescence emission from metallic targets—and for each pixel, the lower energy threshold is scanned to calibrate the energy dependence. The data are fit to a responsivity curve (“S-curve”) that determines the mapping between the possible detector settings and the energy response for each pixel. Here, the calibration is performed for three energy ranges: low (2.3–6 keV), medium (4.5–13.5 keV), and high (5.4–21 keV). We determine the achievable energy resolutions for the low, medium, and high energy ranges as 330 eV, 640 eV, and 950 eV, respectively. The main limitation for the energy resolution is found to be the finite width of the S-curve.

47 OTHER INSTRUMENTATION↗

In situ calibration of charged particle spectrometers on the OMEGA Laser Facility using 241 Am and 226 Ra sources

Charged particle spectrometry is a critical diagnostic to study inertial-confinement-fusion plasmas and high energy density plasmas. The OMEGA Laser Facility has two fixed magnetic charged particle spectrometers (CPSs) to measure MeV-ions. In situ calibration of these spectrometers was carried out using 241 Am and 226 Ra alpha emitters. The alpha emission spectrum from the sources was measured independently using surface-barrier detectors (SBDs). The energy dispersion and broadening of the CPS systems were determined by comparing the CPS measured alpha spectrum to that of the SBD. The calibration method significantly constrains the energy dispersion, which was previously obtained through the measurement of charged particle fusion products. Overall, a small shift of 100 keV was observed between previous and the calibration done in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying uncertainty in analysis of shockless dynamic compression experiments on platinum. II. Bayesian model calibration

Dynamic shockless compression experiments provide the ability to explore material behavior at extreme pressures but relatively low temperatures. Typically, the data from these types of experiments are interpreted through an analytic method called Lagrangian analysis. Here, in this work, alternative analysis methods are explored using modern statistical methods. Specifically, Bayesian model calibration is applied to a new set of platinum data shocklessly compressed to 570 GPa. Several platinum equation-of-state models are evaluated, including traditional parametric forms as well as a novel non-parametric model concept. The results are compared to those in Paper I obtained by inverse Lagrangian analysis. The comparisons suggest that Bayesian calibration is not only a viable framework for precise quantification of the compression path, but also reveals insights pertaining to trade-offs surrounding model form selection, sensitivities of the relevant experimental uncertainties, and assumptions and limitations within Lagrangian analysis. The non-parametric model method, in particular, is found to give precise unbiased results and is expected to be useful over a wide range of applications. The calibration results in estimates of the platinum principal isentrope over the full range of experimental pressures to a standard error of 1.6%, which extends the results from Paper I while maintaining the high precision required for the platinum pressure standard.

Brown, Justin Lee↗

Calibration improvements expand filterscope diagnostic use

The filterscope diagnostic on DIII-D utilizes photomultiplier tubes to measure visible light emission from the plasma. The system has undergone a substantial upgrade since previous attempts to cross-calibrate the filterscope with other spectroscopic diagnostics were unsuccessful. The optics now utilize a dichroic mirror to initially split the light at nearly 99% transmission or reflectance for light below or above 550 nm. This allows the system to measure D α emission without degrading visible light emission from the plasma for wavelengths below 550 nm (to measure D β , D γ , W–I, C-III, etc.). Additional optimization of the optical components and calibration techniques reduce the error in the signal up to 10% in some channels compared to previous methods. Cross-calibration measurements with two other high resolution spectroscopic diagnostics now show excellent agreement for the first time. This expands the capabilities of the filterscope system allowing measurement of divertor detachment, emission profiles, edge-localized mode behavior, and plasma–wall interactions. Additionally, it enables direct comparisons against calculations from boundary plasma simulations. These were not possible before.

47 OTHER INSTRUMENTATION↗