Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Current distribution monitoring enables quench and damage detection in superconducting fusion magnets

Abstract Fusion magnets made from high temperature superconducting ReBCO CORC ® cables are typically protected with quench detection systems that use voltage or temperature measurements to trigger current extraction processes. Although small coils with low inductances have been demonstrated, magnet protection remains a challenge and magnets are typically operated with little knowledge of the intrinsic performance parameters. We propose a protection framework based on current distribution monitoring in fusion cables with limited inter-cable current sharing. By employing inverse Biot-Savart techniques to distributed Hall probe arrays around CORC ® Cable-In-Conduit-Conductor (CICC) terminations, individual cable currents are recreated and used to extract the parameters of a predictive model. These parameters are shown to be of value for detecting conductor damage and defining safe magnet operating limits. The trained model is then used to predict cable current distributions in real-time, and departures between predictions and inverse Biot-Savart recreated current distributions are used to generate quench triggers. The methodology shows promise for quality control, operational planning and real-time quench detection in bundled CORC ® cables for compact fusion reactors.

47 OTHER INSTRUMENTATION↗

Distributed Acoustic Sensing for Whale Vocalization Monitoring: A Vertical Deployment Field Test

Abstract There is growing interest in floating offshore wind turbine (FOWT) technology, where turbines are installed on floating structures anchored to the seabed, allowing wind energy development in areas unsuitable for traditional fixed-platform turbines. Responsible development requires monitoring the impact of FOWTs on marine wildlife, such as whales, throughout the operational lifecycle of the turbines. Distributed acoustic sensing (DAS)—a technology that transforms fiber-optic cables into vibration sensor arrays—has been demonstrated for acoustic monitoring of whales using seafloor telecommunications cables. However, no studies have yet evaluated DAS performance in dynamic, engineered environments, such as floating platforms or moving vessels with complex, dynamic strain loads, despite their relevance to FOWT settings. This study addresses that gap by deploying DAS aboard a boat in Monterey Bay, California, where a fiber-optic cable was lowered using a weighted and suspended mooring line, enabling vertical deployment. Humpback whale vocalizations were captured and identified in the DAS data, noise sources were identified, and DAS data were compared to audio captured by a standalone hydrophone attached to the mooring line and a nearby hydrophone on a cabled observatory. This study is unique in: (1) deploying DAS in a vertical deployment mode, where noise from turbulence, cable vibrations, and other sources posed additional challenges compared to seafloor DAS applications; (2) demonstrating DAS in a dynamic, nonstationary setup, which is uncommon for DAS interrogators typically used in more stable environments; and (3) leveraging looped sections of the cable to reduce the noise floor and mitigate the effects of excessive cable vibrations and strain. This research demonstrates DAS’s ability to capture whale vocalizations in challenging environments, highlighting its potential to enhance underwater acoustic monitoring, particularly in the context of renewable energy development in offshore environments.

Saw, Jaewon↗

HEMP Testing of Substation Yard Circuit Breaker Control and Protective Relay Circuits

There are concerns about the effects of High-Altitude Electromagnetic Pulses (HEMP) on the electric power grid. Activities to date tested and analyzed vulnerability of digital protective relays (DPRs) used in power substations, but the effect of HEMP on the greater substation environment is not well known. This work establishes a method of testing the vulnerability of circuit breaker control and protective relay circuits to the radiated E1 pulse associated with HEMP based on coupling to the cables in a substation yard. Two DPRs from Schweitzer Engineering Laboratories, Inc. were independently tested. The test setup also included a typical cable in a substation yard with return plane to emulate the ground grid and other ground conductors near the yard cable, cabinetry housing the installed DPRs, station battery and battery charger, terminal block elements, and a breaker simulator to emulate a substation yard configuration. The DPRs were powered from the station battery and the transformer inputs energized with a three-phase source to maintain typical operating conditions during the tests. Vulnerability testing consisted of a conducted E1 pulse injected into the center of the yard cable of the DPR circuits. Current measurements on the yard cable and DPR inputs indicated significant attenuation of the conducted pulse arriving at the control house equipment from the emulated substation yard. This reduction was quantified with respect to the equivalent open-circuit voltage on the yard cable. No equipment damage or undesired operation occurred on the tested circuits for values below 180 kV, which is significantly higher than the anticipated coupling to a substation yard cable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed fiber optic strain sensing of bending deformation of a well mockup in the laboratory

Well integrity is critical to the safety and success of subsurface energy exploration and management, as leakage of fluids from subsurface reservoirs is often induced by compromised wells. This study investigates bending deformation of a mockup of an oil/gas well that is subjected to loads expected in deviated wells under reservoir compaction and assesses the feasibility of utilizing distributed fiber optic strain sensing to monitor the deformation. Here, a well mockup, which consists of outer and inner steel pipes with a cemented annulus, is tested under three-point bending loading and its strain and curvature development is monitored by Brillouin optical time domain reflectometry/analysis (BOTDR/A) as well as optical frequency domain reflectometry (OFDR). The primary objective of this research is to assess the strain sensing performance of newly fabricated fiber optic cables and to identify key cable characteristics which could improve the quality of distributed strain measurements with BOTDR/A. Results show that the tight-buffered cable is best suited for strain sensing as its maximum errors in the strain measurement were -36% and -24% against conventional sensors at the maximum elastic and plastic bending loads, respectively, whereas those of the non-tight-buffered cable were -45% and -71%, respectively. Similar trends were obtained in the bending curvature measurement. The detailed design of the tight-buffered cable is presented to elucidate key characteristics of such a cable, which will facilitate accurate distributed strain sensing in oil and gas wells.

42 ENGINEERING↗

Reference floating wind array designs for three representative regions

This work presents the systematic development of three open-source reference floating wind array designs. The designs are tailored to representative site conditions for three regions of the United States: Humboldt Bay off the coast of California, the Gulf of Maine, and the Gulf of America. We adopted existing reference designs for the individual 15 MW turbines, semisubmersible floating platforms, substations, mooring systems, and power cables – integrating and adapting them as needed for each location. We adapted existing dynamic cable designs to use larger conductor sizes to meet the arrays' power transmission requirements, and we set up redundant mooring systems for each substation. The layout of each array is a uniform-grid design optimized to approximately minimize the levelized cost of energy (LCOE) within a square lease area while satisfying spatial constraints. These constraints ensure adequate clearances between adjacent turbines and between underwater components during the layout optimization to prevent clashing and ensure that all components reside within the lease boundaries. Substations are included to allow accounting for intra-array cable costs. They are placed within the uniform grid to maintain the navigability of the arrays. For each feasible layout considered, annual energy production and cable routing costs are calculated and updated in the LCOE objective function. After the optimization, we refined the cable routing with a mix of algorithmic and manual methods to ensure that the cables avoid mooring system components and approach the substation with adequate clearances. We confirmed the suitability of each reference array's layout by comparing the wake losses at each wind heading angle to the wind rose, observing that the optimized layouts largely avoid wake losses in the predominant wind directions. These reference arrays provide open-source baseline designs to enable future research and innovation of floating wind technology at the array scale.

17 WIND ENERGY↗

Flexible Fabric-Based IDC Sensors for Conformal Curved Surface Applications

Interdigital capacitor (IDC) sensors are attractive in-situ sensors that can be used to measure permittivity variations in materials. Such sensors could be powerful enablers for cable insulation aging detection. Since insulation aging is correlated with a change in its material permittivity an IDC can measure that change via its measured capacitance. A new thin, flexible fabric-based IDC sensor is introduced for application on conformal curved surfaces such as an electrical cable surface. A multielectrode IDC and its backplane were fabricated using conductive copper polyester taffeta fabrics that were adhesively bonded to nonconductive polyester fabric. The sensor because of its soft flexible structure eliminates the problem of sensor conductor damage which is common for printed circuit board (PCB) type sensors when conformed to the surface of a cable. It also significantly reduces the airgap between the electrodes and the surface that they must contact in order to measure the capacitance. Airgap reduction and consistency are important in order to accurately predict permittivity variations in cable insulation material due to aging. Both PCB-based sensors and the new fabric-based sensors were built and tested on unaged cables and cables that underwent accelerated aging. Results demonstrate the proposed advantages of the novel fabric-based IDC sensor.

interdigital capacitor sensor, IDC, NDE, PCB senso↗

Wind Turbine Lightning Mitigation System Radar Cross Section Reduction

Modern wind turbines employ Lightning Mitigation Systems (LMSs) in order to reduce costly damages caused by lightning strikes. Lightning strikes on wind turbines occur frequently making LMS configurations a necessity. An LMS for a single turbine includes, among other equipment, cables running inside each blade, along the entire blade length. These cables are connected to various metallic receptors on the outside surface of the blades. The LMS cables can act as significant electromagnetic scatterers which may cause interference to radar systems. This interference may be mitigated by reducing the Radar Cross-Section (RCS) of the wind turbine's LMS. This report investigates proposed modifications to LMS cables in order to reduce the RCS when illuminated by Re locatable Over the Horizon Radar (ROTHR) systems which operate in the HF band (3 - 30 MHz). The proposed modifications include breaking up the LMS cables using spark gap connections, and changing the orientation of the LMS cable within the turbine blade. Both simulated analyses of such RCS mitigation techniques is provided as well as recommendations on further research.

17 WIND ENERGY↗

Intelligent Monitoring System for Real-time Geologic Storage, Optimization, and Reservoir Management

The objective of the subtask was to develop a near-real-time monitoring system for seismic data at the Decatur, IL, geologic carbon sequestration (GCS) site and specifically include fiber-optic cable derived distributed acoustic signal (DAS) data in the process. Owing to the large volumes of data, we opted to utilize existing deep borehole conventional seismic sensors for detection and pull DAS and shallow borehole seismic data once a detection has been made. Unfortunately, the horizontal fiber-optic cables did not yield microseismic signals for use in locating events near the GCS site. Various stacking and filtering approaches were tested without any coherent detection becoming apparent. We attribute the insensitivity to local microseismic events to a lack of coupling in downhole, vertical cable and the non-ideal alignment of the horizontal fiber-optic cable to the vertically polarized seismic energy. Despite the inability to detect and utilize the DAS data from the fiber-optic cables, we developed a general processing framework that enables easy adaptation for future deployment of fiber-optic cables with better suited alignment at Decatur or elsewhere.

Kaven, J. Ole↗

Return on Investment and Sustainability of HVDC Links: Role of Diagnostics, Condition Monitoring, and Material Innovations

HVDC cable systems are becoming an upscaled technical option, compared to AC, because of various factors, including easier interconnections, lower losses, and longer transmission distances. In addition, renewables providing direct DC energy, electrified transportation, and aerospace where DC can be favored because of higher carried specific power all point in the direction of broad future usage of HV and MV DC links. However, contrary to AC, there is little return from on-field installation as regards long-term cable reliability and aging processes. This gap must be covered by intensive research, and contributing to this research is the purpose of this paper. The focus is on key points for HVDC (and MVDC) cable reliability and sustainability, from design modeling able to account for voltage transients and extrinsic aging (such as that caused by partial discharges) to the impact of aging on insulation conductivity (which rules the electric field distribution, thus aging rate). Also, recyclable and nanostructured materials, as well as health conditions, are considered. It is shown how cable design can account for accelerated aging due to voltage transients, as well as for aging-time dependence of conductivity, and how design can be free of extrinsic aging caused by PDs. Algorithms for health condition evaluations, which have additional value in a relatively new technology such as HVDC polymeric cables, are applied to insulation system aging under partial discharges, showing how they can provide an indication of insulation degradation globally or locally (weak spots) and of possible maintenance times. All of this can effectively contribute to reducing the risk of major cable breakdown and damage under operation, which would significantly affect the return on investment (ROI).

Montanari, Gian Carlo (ORCID:0000000320258693)↗

Enhanced critical axial tensile strain limit of CORC ® wires: FEM and analytical modeling

Abstract Conductor on Round Core (CORC ® ) cables and wires are composed of spiraled high-temperature superconducting (HTS) rare-earth barium copper oxide (REBCO) tapes, wound in multiple layers, and can carry very high currents in background magnetic fields of more than 20 T. They combine isotropic flexibility and high resilience to electromagnetic and thermal loads. The brittle nature of HTS tapes limits the maximum allowable axial tensile strain in superconducting cables. An intrinsic tensile strain above about 0.45% will introduce cracks in the REBCO layer of straight HTS tapes resulting in irreversible damage. The helical fashion at which the REBCO tapes are wound around the central core allows tapes to experience only a fraction of the total axial tensile strain applied to the CORC ® wire. As a result, the critical strain limit of CORC ® wires can be increased by a factor of more than 10 that of REBCO tapes. Finite element (FE) and analytical models are developed to predict the performance of CORC ® wires under axial tensile strain. A parametric analysis is carried out by varying the winding angle, the Poisson’s ratio of the CORC ® wire core, the core diameter, and the tape width. The results show that a small variation in winding angle can have a significant impact on the cable’s axial tensile strain tolerance. While the radial contraction of the helically wound tapes in a CORC ® wire under axial tensile strain depends on its winding angle, it is mostly driven by the Poisson’s ratio of the central core, affecting the tape strain state and thus its performance. Contact pressure from multiple layers within the CORC ® wire also affects the CORC ® wire performance. The FE model can be used to optimize the cable design for specific application conditions, resulting in an irreversible strain limit of CORC ® cables and wires as high as 7%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of CORC Conductors With Respect to Individual Tape Properties

CEA has been studying the advantages of a conductor based on an assembly of CORC cables in the high field zone of a hybrid Central Solenoid (CS) magnet for EU-DEMO. To this end, the detailed study of geometrical and electrical parameters of a CORC structure are studied in order to evaluate the cable’s electrical performance as well as to determine a number of important parameters (crossing points, contact surface etc…) as function of the cable structure. The paper first presents these geometrical and performance analyses. It will then try to introduce smeared models in order to reduce the cable’s performance to 1D tape scaling law using effective parameters. That reduction is of importance for use in thermohydraulic models. Finally, the paper will present the case study of a particular CORC conductor that is being procured and is foreseen to be tested in SULTAN in 2025. The paper also will try to give some predictive estimate of the cable performance and identify some of the unknowns related to current redistribution and joint resistance.

CORC↗

Operational and Mission Highlights A Monthly Summary of Top Achievements April 2022

When the Laboratory’s Detonator Production team originally completed manufacturing two ALT939 DEV#1 functional cables — the first development units produced in this lot, team members quickly hit an obstacle when electrical testing for these cables failed. Team members sent the cables out for further testing, which revealed the root cause of failure involved the cables’ connectors. Although a challenging issue to resolve, the team worked together and solved the issue ahead of a stipulated deadline, with the cables completed and shipped to support system tests. The team responsible for this challenging work included members from Detonator Production, Nondestructive Testing & Evaluation, and collaborators from Sandia National Laboratories.

42 ENGINEERING↗

The ICARUS light detection system (Fermilab Italian summer student program 2023)

The ICARUS T600 detector is the largest Liquid Argon Time Projection Chamber ever used on a neutrino beam, and it acts as the far detector of the Short Baseline Neutrino program at Fermilab. Its purpose is the study of the possibility of the existence of a fourth sterile neutrino in the O(eV2) mass range that could take part in the neutrino oscillations. The light detection system of the ICARUS detector plays the role of localising in space and time the neutrino interactions taking place inside the detector, collecting the argon scintillation photons generated when an event occurs. This light detection system also has a crucial role in the trigger system and the rejection of the huge amount of background cosmic events, working together with the trigger request signals sent by the beam complex. In August 2023 part of the cables that are used to carry the signals from the photomultipliers to the electronics were replaced with a new model, because a deterioration of the quality of the signal inside the cables had previously been observed. An analysis of the performance of the new cables was carried out, comparing laser run data collected before and after the change of the cable model, and it was proved that the introduction of the new cables lead to a general improvement of the quality of the signals reaching the electronics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advanced Diagnosis and Accelerated Testing of Balance of System Components for Utility Scale PV Installations: October 1, 2022-September 30, 2024

A study of the durability of PV Balance of System components was performed. Specifically, wire cable jackets and cable connectors were examined within the direct current (DC) PV Power Transmission Chain (PTC). Degraded and failed samples have been obtained from utility PV installations to provide feedback on the degradation modes and the related damage-enabling considerations in today's PV systems. An industry interface group (including system owners, system inspectors, component manufacturers, and test labs) was used to help identify and obtain field-failed samples, for feedback (including samples and experimental design), and to facilitate the subsequent dissemination of the results of this study. Samples were empirically studied using accelerated stress testing with steady-state conditions (cable jackets) in addition to combined-accelerated stress testing (cable jackets, connectors and uncapped connectors). Steady-state accelerated testing has been performed using at least one applied stressor (e.g. UV light) to aid understanding of jacket durability relative to its application. Component- and material-focused failure analysis was conducted to develop an understanding and advise the PV industry. In-depth characterization will be applied selectively to field- and artificially aged-samples, to gain scientific understanding of the structural, chemical, electrical, mechanical, and thermal properties enabling degradation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solution and sensitivity analysis of nonlinear equations using a hypercomplex-variable Newton-Raphson method

Here, the classical Newton-Raphson (NR) method for solving nonlinear equations is enhanced in two ways through the use of hypercomplex variables and algebra. In particular, i) the Jacobian is computed in a highly accurate and automated way, and ii) the derivative of the solution to the nonlinear equations is computed with respect to any parameter contained within the system of equations. These advances provide two significant enhancements in that it is straightforward to provide an accurate Jacobian and to construct a reduced order model (ROM) of arbitrary order with respect to any parameter of the system. The ROM can then be used to approximate the solution for other parameter values without requiring additional solutions of the nonlinear equations. Several case studies are presented including 1D and 2D academic examples with fully functioning Python code provided. Additionally, a case of study of the catenary of an elastic cable subject to its own weight and a vertical point load. Derivatives up to 10th order were computed with respect to material, loading, and geometrical parameters. The derivatives were used to generate reduced order models of the cable deformation and reaction forces at its ends with respect to multiple input parameters. Results show that from a single hypercomplex evaluation of the cable under a single vertical point load, it is possible to generate an accurate reduced order model capable of predicting the cable deformation with 1.5 times the load in the opposite direction and with 3.5 times the load in the same direction without resolving the system of equations.

97 MATHEMATICS AND COMPUTING↗

Minimum Quench Energy of Nb 3 Sn Wires With High Specific Heat Tape

A major problem of state-of-the-art Nb3Snaccelerator magnets is their long training due to thermo-mechanical perturbations. Increasing the specific heat, Cp, of the Rutherford cable would reduce and/or eliminate training by limiting the coils temperature rise. This paper studies feasibility of increasing the Cp of Rutherford-type cables by using thin composite Cu/Gd 2 O 3 and Cu/Gd 2 O 2 S tapes produced by HyperTech Research, Inc. The tape can be either wrapped around the cable, placed on the cable wide faces under the insulation, and/or inserted as a core. Wire samples outfitted with these high-Cp ribbons, or tapes, were prepared and tested at FNAL for their Minimum Quench Energy (MQE). At 90%Ic and 15 T, the average gain of MQE of the Nb 3 Sn wire soldered to the Cu/Gd 2 O 2 S 55 μm thick ribbon was 2.5, and further increased at larger transport currents.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electrical Infrastructure Cost Model for Marine Energy Systems

The National Renewable Energy Laboratory's Electrical Infrastructure Cost Model is an Excel-based tool designed to estimate the electrical infrastructure costs of marine energy components and subsystems. It incorporates data collected from offshore wind projects, utility projects, and other relevant sources to provide accurate and comprehensive cost projections. With its user-friendly interface, the model allows users to input various parameters related to the system array, electrical cables, and substations. By leveraging industry data, cost trends, and technological advancements, the model generates outputs that include system array sizing, electrical cable specifications and costs, substation specifications and costs, and total electrical infrastructure costs. One of the notable strengths of the model is its flexibility in covering multiple-orders-of-magnitude scaled systems, accommodating projects ranging from proof-of-concept or pilot-scale installations to large-scale offshore systems. By collecting data largely from offshore wind reports and utility projects, the model incorporates real-world conditions and accounts for industry-specific factors. It incorporates cost trends and sizing relationships to deliver cost estimations for electrical infrastructure components, such as electrical cables and substation equipment.

16 TIDAL AND WAVE POWER↗

Conceptual design of HTS magnets for fusion nuclear science facility

Second-generation high temperature superconductors (HTS) are available for producing >20 T at the magnet bore compared to 13–16 T for lower temperature superconducting (LTS) toroidal field magnets proposed in recent fusion energy systems studies (FESS) of Fusion Nuclear Science Facility (FNSF). HTS may enable higher fusion power density and smaller device size. High current density cables of multi-layered REBCO tapes have achieved >10 kA at 4–20 K operation in short sample tests for fusion. High current density cables are required for engineering design of FNSF to allow space for interior plasma components. High current density HTS magnets are particularly attractive in reducing the size of a fusion device, beneficial for compact tokamaks, due to their space constraints. Successful HTS magnet development may enable the design of smaller and cheaper fusion pilot plants with a mission of demonstrating net electricity. It may also offer significant cost and performance advantages in non-fusion applicants such as nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI). Furthermore, we developed HTS magnet design concepts for a compact FNSF radial build in order to define the coil size, winding pack mechanical loading and engineering requirements. Partnering with vendors in the US, PPPL is also testing high current cable prototypes aiming at enabling low cost cable technology toward 100 A/mm 2 engineering current density over the winding pack desired in high field model coil development for compact fusion pilot plants.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗