Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

How Can Floor Covering Influence Buildings’ Demand Flexibility?

Although the thermal mass of floors in buildings has been demonstrated to help shift cooling load, there is still a lack of information about how floor covering can influence the floor’s load shifting capability and buildings’ demand flexibility. To fill this gap, we estimated demand flexibility based on the daily peak cooling load reduction for different floor configurations and regions, using EnergyPlus simulations. As a demand response strategy, we used precooling and global temperature adjustment. The result demonstrated an adverse impact of floor covering on the building’s demand flexibility. Specifically, under the same demand response strategy, the daily peak cooling load reductions were up to 20–34% for a concrete floor whereas they were only 17–29% for a carpet-covered concrete floor. This is because floor covering hinders convective coupling between the concrete floor surface and the zone air and reduces radiative heat transfer between the concrete floor surface and the surrounding environment. In hot climates such as Phoenix, floor covering almost negated the concrete floor’s load shifting capability and yielded low demand flexibility as a wood floor, representing low thermal mass. Sensitivity analyses showed that floor covering’s effects can be more profound with a larger carpet-covered area, a greater temperature adjustment depth, or a higher radiant heat gain. With this effect ignored for a given building, its demand flexibility would be overestimated, which could prevent grid operators from obtaining sufficient demand flexibility to maintain a grid. Our findings also imply that for more efficient grid-interactive buildings, a traditional standard for floor design could be modified with increasing renewable penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microgrid Tiered Circuits Effects for a Planned Housing Community in Puerto Rico

Puerto Rico faced a double strike from hurricanes Irma and Maria in 2017. The resulting damage required a comprehensive rebuild of electric infrastructure. There are plans and pilot projects to rebuild with microgrids to increase resilience. This paper provides a techno-economic analysis technique and case study of a potential future community in Puerto Rico that combines probabilistic microgrid design analysis with tiered circuits in building energy modeling. Tiered circuits in buildings allow electric load reduction via remote disconnection of non-critical circuits during an emergency. When coupled to a microgrid, tiered circuitry can reduce the chances of a microgrid's storage and generation resources being depleted. The analysis technique is applied to show 1) Approximate cost savings due to a tiered circuit structure and 2) Approximate cost savings gained by simultaneously considering resilience and sustainability constraints in the microgrid optimization. The analysis technique uses a resistive capacitive thermal model with load profiles for four tiers (tier 1-3 and non-critical loads). Three analyses were conducted using: 1) open-source software called Tiered Energy in Buildings and 2) the Microgrid Design Toolkit. For a fossil fuel based microgrid 30% of the total microgrid costs of 1.18 million USD were calculated where the non-tiered case keeps all loads 99.9% available and the tiered case keeps tier 1 at 99.9%, tier 2 at 95%, tier 3 at 80% availability, with no requirement on non-critical loads. The same comparison for a sustainable microgrid showed 8% cost savings on a 5.10 million USD microgrid due to tiered circuits. The results also showed 6-7% cost savings when our analysis technique optimizes sustainability and resilience simultaneously in comparison to doing microgrid resilience analysis and renewables net present value analysis independently. Though highly specific to our case study, similar assessments using our analysis technique can elucidate value of tiered circuits and simultaneous consideration of sustainability and resilience in other locations.

building energy modeling↗

Demonstration of Intelligent HVAC Load Management With Deep Reinforcement Learning: Real-World Experience of Machine Learning in Demand Control

We report that buildings account for 40% of total primary energy consumption and 30% of all CO 2 emissions worldwide. A large portion of building energy consumption is due to heating, ventilation, and air-conditioning (HVAC) systems. In the summer, for example, more than 50% of a building’s electricity consumption is used for cooling. With proper energy management, buildings can provide load shifting, peak shaving, frequency regulation, and many other demand response services.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic modelling and control strategy of a temperature-driven metal hydride cooling system for buildings

A temperature-driven coupled metal hydride (MH) based thermal energy storage (TES) system can allow to shave and shift the peak energy demand in buildings. The high energy density and long-term (seasonal) energy storage capability are its major advantages over other energy storage methods. The dynamic nature of the MH operation, however, requires controlled hydrogen transfer between the coupled MHs at a rate needed to meet the building's transient load. While temperature-driven MH systems are studied in the literature, their application in buildings and control are scarcely reported. Here, this paper presents a control-based dynamic modeling of the temperature-driven coupled MH-TES system for building cooling applications. The dynamic model is developed in MATLAB(R) Simulink environment, considering the thermodynamic and kinetic behaviors of the MH systems. Based on a preliminary analysis of a property database of over 337 hydrides, we select around 1600 MH pairs suitable for building cooling applications. Each of these MH pairs is studied for their performance using the dynamic model, and among all, Zr 0.76 Ti 0.24 Ni 1.16 Mn 0.63 V 0.14 Fe 0.18 -Ti 0.85 Zr 0.15 Cr 1.2 Mn 0.8 MH pair showed fast dynamics along with high coefficient of performance (COP) of 0.71. A parametric investigation is performed on this MH pair to understand the effect of operating temperatures. Finally, three proportional-integral (PI) feedback controllers are investigated to regulate the temperature, pressure and mass exchange between the coupled MH pairs. The developed PI controller is sufficiently capable of rejecting the signal noise from the hydrogen flow and internal heat exchange processes with root mean square error of 5.78 W between reference and actual cooling load.

08 HYDROGEN↗

Optimal operation of multi-plant steam district heating systems for enhanced efficiency and sustainability

Despite their crucial role in supplying heat and power to universities, industries, and healthcare facilities, many steam-based district heating systems rely on outdated control methods. Among these, multi-central plant districts are particularly challenging due to the complexities of coordinating multiple plants, optimizing load distributions, and managing system downtime. In response, new operational strategies are developed to enhance the efficiency and sustainability of steam districts while utilizing existing resources. These strategies include reducing plant operational pressure without compromising the reliable supply to buildings and optimizing load allocation across multiple plants. The load allocation considers boiler part-load efficiency, runtime, network losses, and building pressure set points, and is compared with traditional multi-boiler controls. To support this exploration, new dynamic Modelica models are developed. In addition, methods to reduce modeling complexities are incorporated, enhancing their suitability for practical applications. A holistic district-wide analysis using a real university case study demonstrates a 4.7% fuel savings by lowering boiler operational pressure from 900 kPa to 600 kPa, along with a 13.3% reduction in condensation losses across the distribution network. Furthermore, the load allocation approach results in a 13.1% reduction in fuel consumption during peak winter periods and 15.3% during shoulder periods, with corresponding decreases in carbon emissions and fuel costs. This approach can also save maintenance costs by reducing the boiler runtime by 49.6%. In conclusion, this research underscores the benefits of retrofitting aging steam district heating systems, offering immediate operational improvements by enhancing efficiency, meeting regulatory compliance, and extending infrastructure lifespans while delaying costly overhauls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

End-Use Savings Shapes: Public Dataset Release for Residential Round 1 [Slides]

The End-Use Load Profiles project created a public database of 900,000 individual building end-use load profiles. Load profiles were modeled to represent the U.S. building stock as it was in 2018, as nearly as possible based on the best available data. The End-Use Savings Shapes follow-on project adds measure impact profiles for energy efficiency and electrification packages to the public dataset. This presentation details the public dataset release on September 20, 2022.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Maximizing the Benefits of On-Site Renewable Energy Generation Using On-Site Energy Storage

The commercial and industrial building sectors have a major role to play in a U.S. low-carbon future. Building owners can make a difference by deploying on-site renewable generation and storage technologies, which facilitates future-proofing their buildings as well as more effectively meeting the service requirements of the building. This resource provides an overview of common generation, storage, and load management technologies in behind-the-meter systems, and serves as a primer to demonstrate the impact on net building loads required from the grid for different sizes of renewable generation along with on-site electrical and thermal storage. These discussions can help commercial building owners communicate the value of these systems to project teams and develop innovative behind-the-meter solutions to achieve their energy goals.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

A bi-level advanced control framework for large-scale control of buildings with system-level impact

Increased electricity consumption combined with new forms of generation is testing the reliability of our grid infrastructure. This work describes a method to improve the reliability of the grid through large-scale advanced building control. This paper develops a bi-level distributed control framework to shift the load of 153 buildings to achieve a system-level objective of tracking a power reference signal. This bi-level control is based on the previously-developed ANPV-MPC, a predictive controller that uses a Bayesian neural network to generate an accurate control model and adapt to changing conditions over time. By shifting the building electricity demand to better match the available power, the grid system supplying the buildings is more reliable as evidenced by the analysis of node voltages across an IEEE 13-bus distribution system. The proposed bi-level control framework tracks the system-level power reference with enough accuracy to regulate node voltages across the IEEE 13-bus distribution system within ANSI limits of ±5%. Additionally, the adaptive nature of ANPV-MPC allows each building across the system to adapt to changing conditions, further amplifying the system-level reliability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Performance of Awnings in Residential Buildings

Residential buildings consume approximately 20% of the total primary energy in the United States. More than 50% of this energy is spent in heating, cooling, and lighting these buildings. Solar heat gain is one of the largest and most variable sources of cooling load in these buildings, while it can also provide passive heating during the heating season. Shading devices can be used to control the amount of solar heat gain in buildings. Various studies have considered how different shading devices and their applications affect energy and occupant comfort in buildings. However, most of these studies were limited to planar shading devices such as roller shades, cellular shades, and blinds. Although some theoretical studies have been performed for awnings, the energy performance of awnings has rarely been studied via either energy simulation or field measurement. In this study, the authors evaluated the energy performance of typical operable awnings by using field data, aided by simulation. Awnings were installed on a real house, and measurements were performed to evaluate the thermal performance of the awning. The measured data were then used to develop a calibrated energy model and evaluate the awning’s energy performance. The annual simulation of the building model used showed that awnings left in the closed position from April to September can reduce annual HVAC energy consumption by 15% compared with a building without any shades. The validated model was used in US Department of Energy prototype buildings to evaluate awning energy performance in climate zones 1A through 4B via energy simulation. For these prototype buildings, energy savings of up to 1,034 kWh were achieved for a building with a conditioned floor area of 2,377 ft 2 .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Overall chilled water system energy consumption modeling and optimization

The emergence of increasingly affordable variable-speed drive technology has changed the approach used to control chilled water systems equipped with these drives. The purpose of this research was to develop an integrated chilled water modeling technique that can determine the optimal system setpoints and estimate the energy saving potential of chiller system. The chiller system equipped with Variable Frequency Drives (VFDs) on cooling tower fans and condenser water pumps. To accomplish the objective, physical component models of the centrifugal chiller, cooling tower and condenser water pump were established with the goal of incorporating the system’s condenser water flow rate and cooling tower fan speeds as optimization variables. Furthermore, a cooling load prediction algorithm was developed using a multiple non-linear regression model to approximate the building’s cooling load subject to a range of environmental conditions. The inputs and outputs of the individual component models were linked to estimate how adjusting the cooling tower fan and condenser water pump speed would influence the system’s comprehensive performance. Here, the overall system model was then optimized using a generalized reduced gradient optimization algorithm to determine the potential energy savings through speed control with VFDs and to ascertain a control logic strategy for the building automation system to operate the heating and cooling system. A case-study was performed on a single chiller system at a museum and the model was calibrated according to logged data collected over four months. Results showed that for the system analyzed, the energy saving of optimizing the cooling tower fan system was found to be 12–15%, while the energy saving potential of optimizing the condenser water pump with the cooling tower fan was negligible. Additionally, comparing different cooling tower fan control strategies showed that a wet-bulb approach-based cooling tower control strategy was shown to have the highest correlation to the optimized fan speed with an R 2 of 0.924.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Expert system development for probabilistic load simulation

A knowledge based system LDEXPT using the intelligent data base paradigm was developed for the Composite Load Spectra (CLS) project to simulate the probabilistic loads of a space propulsion system. The knowledge base approach provides a systematic framework of organizing the load information and facilitates the coupling of the numerical processing and symbolic (information) processing. It provides an incremental development environment for building generic probabilistic load models and book keeping the associated load information. A large volume of load data is stored in the data base and can be retrieved and updated by a built-in data base management system. The data base system standardizes the data storage and retrieval procedures. It helps maintain data integrity and avoid data redundancy. The intelligent data base paradigm provides ways to build expert system rules for shallow and deep reasoning and thus provides expert knowledge to help users to obtain the required probabilistic load spectra.

Ho, H.↗

The Future of Zero Energy Buildings: Produce, Respond, Regenerate: Preprint

The zero energy buildings concept is more than 20 years old, and the paradigm shift from buildings as energy consumers to buildings as energy producers is underway. Buildings also consume land and material resources, however, with attendant environmental impacts. Another paradigm is emerging: a built environment that produces energy and is environmentally responsive and regenerative. This paper investigates an updated framework for thinking about zero energy buildings that includes discussions of prioritizing renewables; determining on-site versus off-site generation; exploring how and when buildings should use energy; and balancing renewables, storage, and energy efficiency. Buildings are typically connected to the utility grid and the utility grid develops largely in response to the built environment. If more buildings’ real time electricity use aligned with renewable generation, more renewables would be added to the grid. Ultimately, the goal for zero energy buildings will be to use 100% renewables, 100% of the time, matching loads with energy storage and renewable generation at each discrete timestep over a year. This target is beyond the current zero energy definitions, which focus on an annual balance of renewable supply and energy demand and use the grid to “store” excess production to make up for hours without sufficient on-site renewable generation. This paper expands this upgraded concept and outlines simple metrics to evaluate the alignment of renewable sources and storage with building loads. This process can provide insights on building design considerations, including the use of flexible loads and optimal resource management.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

A Modified Sequence-to-point HVAC Load Disaggregation Algorithm

This paper presents a modified sequence-to-point (S2P) algorithm for disaggregating the heat, ventilation, and air conditioning (HVAC) load from the total building electricity consumption. The original S2P model is convolutional neural network (CNN) based, which uses load profiles as inputs. We propose three modifications. First, the input convolution layer is changed from 1D to 2D so that normalized temperature profiles are also used inputs to the S2P model. Second, a drop-out layer is added to improve adaptability and generalizability so that the model trained in one area can be transferred to other geographical areas without labelled HVAC data. Third, a fine-tuning process is proposed for areas with a small amount of labelled HVAC data so that the pre-trained S2P model can be fine-tuned to achieve higher disaggregation accuracy (i.e., better transferability) in other areas. The model is first trained and tested using smart meter and sub-metered HVAC data collected in Austin, Texas. Then, the trained model is tested on two other areas: Boulder, Colorado and San Diego, California. Simulation results show that the proposed modified S2P algorithm outperforms the original S2P model and the support-vector machine based approach in accuracy, adaptability, and transferability.

Ye, Kai↗

NECAP 4.1: NASA's Energy-Cost Analysis Program input manual

The computer program NECAP (NASA's Energy Cost Analysis Program) is described. The program is a versatile building design and energy analysis tool which has embodied within it state of the art techniques for performing thermal load calculations and energy use predictions. With the program, comparisons of building designs and operational alternatives for new or existing buildings can be made. The major feature of the program is the response factor technique for calculating the heat transfer through the building surfaces which accounts for the building's mass. The program expands the response factor technique into a space response factor to account for internal building temperature swings; this is extremely important in determining true building loads and energy consumption when internal temperatures are allowed to swing.

Jensen, R. N.↗

Integrated and Advanced Lighting Controls: The Next Frontier in Energy Savings?

Lighting energy use has significantly declined as a portion of overall building energy usage due largely to the uptake of more efficient light-emitting diode technology. Although the per unit cost of lighting controls has declined, the installation and use of lighting controls are low and the installation and use of advanced controls are abysmally low. Increased use of advanced and connected lighting controls, and the ability to integrate lighting with other building systems (e.g., heat and air, plug loads, miscellaneous loads) that make the building “smarter,” offer the potential for additional energy savings. Studies into the performance of new, advanced lighting control technologies in commercial buildings have generated new findings. Although each field evaluation has interesting results individually, an analysis of their collective findings across a spectrum of commercial building types will help establish the current state of the technology and implications related to market readiness. This paper will analyze results from available field evaluation studies (recently completed as well as ongoing) of retrofit sites and share findings and insights including: • The amount of energy savings that may be expected from these systems. • Cost effectiveness, monetization, and cost points of these systems. • Ideal characteristics of these systems the most viable. • Lessons learned from the installation, commissioning, and occupant response of these systems. The results will support Department of Energy research investments and help inform efficiency programs of the potential of these emerging technologies and how they may fit within the clean energy future.

Myer, Michael↗

Techno-Economic Assessment of Residential Heat Pump Integrated with Thermal Energy Storage

Phase change material (PCM)-based thermal energy storage (TES) can provide energy and cost savings and peak demand reduction benefits for grid-interactive residential buildings. Researchers established that these benefits vary greatly depending on the PCM phase change temperature (PCT), total TES storage capacity, system configuration and location and climate of the building. In this study, preliminary techno-economic performance is reported for a novel heat pump (HP)-integrated TES system using an idealized approach. A simplified HP-TES was modeled for 1 year of space heating and cooling loads for a residential building in three different climates in the United States. The vapor compression system of the HP was modified to integrate with TES, and all heat transfer to and from the TES was mediated by the HP. A single PCM was used for heating and cooling, and the PCT and TES capacity were varied to observe their effects on the building’s energy consumption, peak load shifting and cost savings. The maximum reduction in electric consumption, utility cost and peak electric demand were achieved at a PCT of 30 °C for New York City and 20 °C for Houston and Birmingham. Peak energy consumption in Houston, New York City, and Birmingham was reduced by 47%, 53%, and 70%, respectively, by shifting peak load using a time-of-use utility schedule. TES with 170 MJ storage capacity allowed for maximum demand shift from on-peak to off-peak hours, with diminishing returns once the TES capacity equaled the daily building thermal loads experienced during the most extreme ambient conditions.

25 ENERGY STORAGE↗

A three-year dataset supporting research on building energy management and occupancy analytics

Abstract This paper presents the curation of a monitored dataset from an office building constructed in 2015 in Berkeley, California. The dataset includes whole-building and end-use energy consumption, HVAC system operating conditions, indoor and outdoor environmental parameters, as well as occupant counts. The data were collected during a period of three years from more than 300 sensors and meters on two office floors (each 2,325 m 2 ) of the building. A three-step data curation strategy is applied to transform the raw data into research-grade data: (1) cleaning the raw data to detect and adjust the outlier values and fill the data gaps; (2) creating the metadata model of the building systems and data points using the Brick schema; and (3) representing the metadata of the dataset using a semantic JSON schema. This dataset can be used in various applications—building energy benchmarking, load shape analysis, energy prediction, occupancy prediction and analytics, and HVAC controls—to improve the understanding and efficiency of building operations for reducing energy use, energy costs, and carbon emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing Customer Experience and Business Models around Price-to-Device Communication and Smart Control Pathways in CalFlexHub

California is facing three major challenges in electrical grid operation: renewable overgeneration, steep evening ramping, and growing peak demand. The state has identified dynamic retail price response as a key strategy evidenced by CPUC’s Dynamic Rates proceeding and CEC’s Load Management Standards. Furthermore, the CEC launched a $16M “California Load Flexibility Research and Deployment Hub (CalFlexHub)” administered by Berkeley Lab to accelerate price-response flexible load technologies in buildings and EV charging. There are more than 16 laboratory and field demonstration projects in CalFlexHub, each demonstrating innovative automated price-response technologies. CalFlexHub tests various pathways through which hourly price signals and triggered control commands are communicated to load-flexible devices such as smart thermostats, heat pumps, water heaters, and EVs. We identified seven unique communication and control pathways, which involve combinations of third-party cloud, device OEM’s cloud, building central gateway, and local controller in between the price server and the load-flexible devices. It is important for utilities and policy makers to understand the long-term implications of each pathway in designing future programs and creating related policies and mandates for market transformation. We propose an evaluation framework including the following aspects: ● Functionality: connectivity and uptime, resilience, and optimization; ● Customer experience: simplicity in setup, troubleshooting support, continuity, customer choice, first cost, and ongoing cost; ● Business model and scalability: advance interoperability, holistic solution, bridge unique gap, customer base, and value streams and pricing structures. In this paper, we identify emerging business models associated with each communication pathway and discuss their positive features and challenges from the above aspects.

Liu, Jingjing↗