Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “biomedical device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

TU-AB-204-04: Partnerships

The responsibilities of the Food and Drug Administration (FDA) have increased since the inception of the Food and Drugs Act in 1906. Medical devices first came under comprehensive regulation with the passage of the 1938 Food, Drug, and Cosmetic Act. In 1971 FDA also took on the responsibility for consumer protection against unnecessary exposure to radiation-emitting devices for home and occupational use. However it was not until 1976, under the Medical Device Regulation Act, that the FDA was responsible for the safety and effectiveness of medical devices. This session will be presented by the Division of Radiological Health (DRH) and the Division of Imaging, Diagnostics, and Software Reliability (DIDSR) from the Center for Devices and Radiological Health (CDRH) at the FDA. The symposium will discuss on how we protect and promote public health with a focus on medical physics applications organized into four areas: pre-market device review, post-market surveillance, device compliance, current regulatory research efforts and partnerships with other organizations. The pre-market session will summarize the pathways FDA uses to regulate the investigational use and commercialization of diagnostic imaging and radiation therapy medical devices in the US, highlighting resources available to assist investigators and manufacturers. The post-market session will explain the post-market surveillance and compliance activities FDA performs to monitor the safety and effectiveness of devices on the market. The third session will describe research efforts that support the regulatory mission of the Agency. An overview of our regulatory research portfolio to advance our understanding of medical physics and imaging technologies and approaches to their evaluation will be discussed. Lastly, mechanisms that FDA uses to seek public input and promote collaborations with professional, government, and international organizations, such as AAPM, International Electrotechnical Commission (IEC), Image Gently, and the Quantitative Imaging Biomarkers Alliance (QIBA) among others, to fulfill FDA’s mission will be discussed. Learning Objectives: Understand FDA’s pre-market and post-market review processes for medical devices Understand FDA’s current regulatory research activities in the areas of medical physics and imaging products Understand how being involved with AAPM and other organizations can also help to promote innovative, safe and effective medical devices J. Delfino, nothing to disclose.

60 APPLIED LIFE SCIENCES↗

An air flow sensor for neonatal mechanical ventilation applications based on a novel fiber-optic sensing technique

In this work, a simple and low-cost air flow sensor, based on a novel fiber-optic sensing technique has been developed for monitoring air flows rates supplied by a neonatal ventilator to support infants in intensive care units. The device is based on a fiber optic sensing technique allowing (a) the immunity to light intensity variations independent by measurand and (b) the reduction of typical shortcomings affecting all biomedical fields (electromagnetic interference and patient electrical safety). The sensing principle is based on the measurement of transversal displacement of an emitting fiber-optic cantilever due to action of air flow acting on it; the fiber tip displacement is measured by means of a photodiode linear array, placed in front of the entrance face of the emitting optical fiber in order to detect its light intensity profile. As the measurement system is based on a detection of the illumination pattern, and not on an intensity modulation technique, it results less sensitive to light intensity fluctuation independent by measurand than intensity-based sensors. The considered technique is here adopted in order to develop two different configurations for an air flow sensor suitable for the measurement of air flow rates typically occurring during mechanical ventilation of newborns: a mono-directional and a bi-directional transducer have been proposed. A mathematical model for the air flow sensor is here proposed and a static calibration of two different arrangements has been performed: a measurement range up to 3.00 Multiplication-Sign 10{sup -4} m{sup 3}/s (18.0 l/min) for the mono-directional sensor and a measurement range of {+-}3.00 Multiplication-Sign 10{sup -4} m{sup 3}/s ({+-}18.0 l/min) for the bi-directional sensor are experimentally evaluated, according to the air flow rates normally encountered during tidal breathing of infants with a mass lower than 10 kg. Experimental data of static calibration result in accordance with the proposed theoretical model: for the mono-directional configuration, the coefficient of determination r{sup 2} is equal to 0.997; for the bi-directional configuration, the coefficient of determination r{sup 2} is equal to 0.990 for positive flows (inspiration) and 0.988 for negative flows (expiration). Measurement uncertainty {delta}Q of air flow rate has been evaluated by means of the propagation of distributions and the percentage error in the arrangement of bi-directional sensor ranges from a minimum of about 0.5% at -18.0 l/min to a maximum of about 9% at -12.0 l/min.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microelectromechanical System (MEMS) Device Being Developed for Active Cooling and Temperature Control

High-capacity cooling options remain limited for many small-scale applications such as microelectronic components, miniature sensors, and microsystems. A microelectromechanical system (MEMS) using a Stirling thermodynamic cycle to provide cooling or heating directly to a thermally loaded surface is being developed at the NASA Glenn Research Center to meet this need. The device can be used strictly in the cooling mode or can be switched between cooling and heating modes in milliseconds for precise temperature control. Fabrication and assembly employ techniques routinely used in the semiconductor processing industry. Benefits of the MEMS cooler include scalability to fractions of a millimeter, modularity for increased capacity and staging to low temperatures, simple interfaces, limited failure modes, and minimal induced vibration. The MEMS cooler has potential applications across a broad range of industries such as the biomedical, computer, automotive, and aerospace industries. The basic capabilities it provides can be categorized into four key areas: 1) Extended environmental temperature range in harsh environments; 2) Lower operating temperatures for electronics and other components; 3) Precision spatial and temporal thermal control for temperature-sensitive devices; and 4) The enabling of microsystem devices that require active cooling and/or temperature control. The rapidly expanding capabilities of semiconductor processing in general, and microsystems packaging in particular, present a new opportunity to extend Stirling-cycle cooling to the MEMS domain. The comparatively high capacity and efficiency possible with a MEMS Stirling cooler provides a level of active cooling that is impossible at the microscale with current state-of-the-art techniques. The MEMS cooler technology builds on decades of research at Glenn on Stirling-cycle machines, and capitalizes on Glenn s emerging microsystems capabilities.

Beach, Duane E.↗

Retrospective comparison of outcomes and associated complications between large bore radiologically inserted gastrostomy tube types

Purpose: Multiple approaches to radiologically inserted gastrostomy (RIG) exist. The goal of this study was to compare 30-day outcomes and associated complications between large bore balloon-retained (BR), loop-retained (LR), and pull-type (PT) RIG devices. Methods: Data on 1477 patients who underwent RIG between January 1, 2005 and December 31, 2016 were collected retrospectively using a dedicated interventional radiology database and electronic medical record. Statistical analysis was performed to compare complication rates between BR, LR, and PT devices. Results: Ninety-eight percent (1477/1507) of the procedures were successfully performed. A total of 752 BR, 323 LR, and 402 PT gastrostomy tubes were placed. The overall complication rate for BR catheters was 5.7% (25 major [3.3%] and 18 minor [2.4%]). The overall complication rate for PT catheters was 3.7% (8 major [2.0%] and 7 minor [1.7%]). The overall complication rate for LR catheters was 1.6% (4 major [1.4%] and 1 minor [0.8%]). Compared to BR catheters, LR catheters had significantly fewer total complications (P = 0.01) but not minor complications (P = 0.052). There were no significant differences in the number of complications between LR and PT catheters or between BR and PT catheters. Conclusions: Use of BR, LR, and PT devices for RIG is safe with a low incidence of complications. Compared to BR catheters, primary insertion of a LR gastrostomy was associated with significantly fewer overall complications within the first 30 days. Therefore, for initial tube placement, large bore LR catheters may be preferred over BR devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Repair of Abdominal Aortic Aneurysms in the Presence of a Transplanted Kidney

PurposeTo present our experience performing endovascular repair of abdominal aortic aneurysms in kidney transplanted patients.MethodsA retrospective review of all patients who underwent endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA) performed at our institution from 2007 to 2014. We identified all patients who had previously undergone a kidney transplant. Data collected included: comorbidities, preoperative imaging modalities, indication for surgery, stent graft configurations, pre- and postoperative renal function, perioperative complications, and survival rates.ResultsA total of 267 EVARs were performed. Six (2 %) had a transplanted kidney. Mean age was 74 (range, 64–82) years; five were males. Mean time from transplantation to EVAR was 7.5 (range, 2–12) years. Five underwent preoperative planning with noncontrast modalities only. Devices used included bifurcated (n = 3), aortouniiliac (n = 2), and tube (n = 1) stent grafts. Technical success was achieved in all patients. None experienced deterioration in renal function. Median follow-up was 39 (range, 6–51) months. Four patients were alive at the time of the study. Two patients expired during the period of follow-up from unrelated causes.ConclusionsEVAR is an effective modality for the management of AAAs in the coexistence of a transplanted kidney. It can be performed with minimal morbidity and mortality without harming the transplanted kidney. Special consideration should be given to device configuration to minimize damage to the renal graft.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved Solid-State Microanemometer

Improved solid-state microanemometer suitable for measuring flows in variety of biomedical, industrial, and other applications. Small size, unique design, and one-piece construction provides combination of short response time, structural rigidity, optimal dissipation of heat, and versatility in application. Device includes four integral sensing resistors exposed to flow measured and serves as hot-film anemometer subunits. Sensing resistors connected to external excitation-and-measurement circuits operating in any of standard hot-film-anemometer modes; constant input voltage, constant input current, or constant resistance with feedback.

Henderson, H. Thurman↗

Design and Analysis of Shape Memory Spring Tires for Martian and Lunar Rover Vehicles

Shape memory alloys (SMAs) have played an important role in various innovative engineering and medical applications, such as aerospace actuators, vibration damping devices, and coronary stents. In applications, shape memory alloys are commonly utilized in two fundamentally different ways: (i) making use of the superelasticity/ pseudoelasticity (SE/PE) phenomena, as in applications in biomedical engineering, and (ii) taking advantages of the shape memory effect (SME), as is used for actuators. Their ability to act in such vastly different capacities is mainly due to their unique capability to recover large amounts of deformation produced by either applied stresses or temperature changes. One recent emerging application in use of SMAs has been in the area of non-pneumatic tire designs for Martian or Lunar roving vehicles. These vehicles require tires that are capable of traversing rugged terrain while withstanding extreme temperatures and atmospheric conditions. Inspired by the flexible wire mesh tires used on three Lunar Roving Vehicle (LRV) missions to the Moon on Apollo 15, 16, and 17, a new compliant tire technology was developed by the NASA Glenn Research Center (GRC) and Goodyear Tire & Rubber, known as the Spring Tire. The Spring Tire consists of several hundred coiled springs woven into a flexible mesh and formed into the shape of a tire. Like the LRV wire mesh tires, the original Spring Tires were made from spring steel and were prone to permanent deformation when undergoing high localized loads. Later, a new iteration of this technology was invented, known as the ‘Superelastic Tire’. This new technology incorporated the use of superelastic SMA springs, which could effectively undergo approximately 30 times more reversible deformation than the steel spring. It also provided even greater durability and allowed for more flexibility in design, such as the use of other structural forms to reduce mass or increase load carrying capacity. Because of the unique nature of both the SMA material and the complex interactions between the springs, designing Spring Tires for a specific application requires extensive effort. Historically, design decisions have relied on full-scale empirical testing; however, this is very expensive and time consuming, especially when multiple iterations are needed. Therefore, developing a large-scale, robust, and predictive numerical model entailing complex spring interactions and the shape memory material behavior within a tire construct is the first essential step towards a successful design program. The current work focuses on implementation of the user-defined Shape Memory Alloy (SMA) model, otherwise known as SMA-GVIPs, in the Finite Element analysis (FEA) program ABAQUS for large-scale simulations of the GRC-developed Spring Tires made of SMA. The novelty of this work lies in the thorough, detail-oriented, and computationally efficient finite element analysis of full-scale SMA tires. A well-thought material characterization plan followed by model validation and a systemic sensitivity study on SMA tires has never been reported in the previous literature. The main objective of this study is to help the team improve and optimize the structural design of the SMA tires through in-depth numerical analysis and sensitivity studies. Various design variables (wire diameter, coil diameter, pitch, bead angle, and number of springs) were varied to study their influence on the global load-displacement response of the tire construct. A detailed investigation of the three-dimensional stress states was also carried out to enhance our understanding of the local changes as the tire goes through global deformation. It was concluded that a robust numerical model with a good predictive capability, together with a thoughtfully crafted sensitivity study can result in improved design iterations required to reach a desired tire performance while, significantly reducing manufacturing, labor and testing expenses. A summary of the Finite Element (FE) model construction will be presented together with a description of the user-defined SMA model, characterization process, experimental results, model validation, and numerical sensitivity study results.

shape memory alloys↗

Summer Biomedical Engineering Institute 1972

The five problems studied for biomedical applications of NASA technology are reported. The studies reported are: design modification of electrophoretic equipment, operating room environment control, hematological viscometry, handling system for iridium, and indirect blood pressure measuring device.

Deloatch, E. M.↗

Nuclear Science Symposium, 19th, and Nuclear Power Systems Symposium, 4th, Miami, Fla., December 6-8, 1972, Proceedings.

Major topics covered include radiation monitoring instrumentation, nuclear circuits and systems, biomedical applications of nuclear radiation in diagnosis and therapy, plasma research for fusion power, reactor control and instrumentation, nuclear power standards, and applications of digital computers in nuclear power plants. Systems and devices for space applications are described, including the Apollo alpha spectrometer, a position sensitive detection system for UV and X-ray photons, a 4500-volt electron multiplier bias supply for satellite use, spark chamber systems, proportional counters, and other devices. Individual items are announced in this issue.

Source record↗

Influence of surface pattern on the biological properties of Ti grade 2

Highlights: • Laser modification causes changes in chemical composition of the surface. • Laser treatment creates roughness in a range from nano- to micrometers. • The surface modification presented results in a multimodal topography. • A hierarchical topography promotes protein adsorption. - Abstract: This paper presents a detailed characterization of Ti surface geometries as produced by non-contact laser functionalization and its impact on the process of protein adsorption. The proposed surface modification is designed for the local treatment of implantable devices with original roughness. In this work, titanium plates were initially modified by the two most common mechano-chemical treatments, shot peening and acid etching. The material under study was next functionalized DLIL (Direct Laser Interference Lithography) in order to obtained two different surface patterns: grooves and islands. The modified surfaces were characterized in terms of their shape, roughness, wettability, surface energy and chemical composition. For this purpose, the following methods were used: scanning electron microscopy, optical profilometry, atomic force microscopy, contact angle measurements, and X-ray photoelectron spectroscopy. Protein adsorption tests were conducted to consider the potential of the proposed methodology in biomedical applications and to compare the influence of the two different surface patterns on the initial state of ossointegration. To this end, XPS and FTIR studies were conducted. The systematic analysis presented will be useful when selecting an appropriate surface geometry for the local surface functionalization of implantable devices.

36 MATERIALS SCIENCE↗

Nondisruptive Dissolution of Hyperpolarized 129 Xe into Viscous Aqueous and Organic Liquid Crystalline Environments

Studies of hyperpolarized xenon-129 (hp- 129 Xe) in media such as liquid crystals and cell suspensions are in demand for applications ranging from biomedical imaging to materials engineering but have been hindered by the inability to bubble Xe through the desired media as a result of viscosity or perturbations caused by bubbles. In this paper a device is reported that can be reliably used to dissolve hp- 129 Xe into viscous aqueous and organic samples without bubbling. This method is robust, requires small sample volumes (<60 μL), is compatible with existing NMR hardware, and is made from readily available materials. Experiments show that Xe can be introduced into viscous and aligned media without disrupting molecular order. We detected dissolved xenon in an aqueous liquid crystal that is disrupted by the shear forces of bubbling, and we observed liquid-crystal phase transitions in (MBBA). This tool allows an entirely new class of samples to be investigated by hyperpolarized-gas NMR spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Femoral Artery Stenosis Following Percutaneous Closure Using a Starclose Closure Device

Starclose (Abbott Vascular Devices, Redwood City, CA) is a new arterial closure device that seals a femoral puncture site with an extravascular star-shaped nitinol clip. The clip projects small tines into the arterial wall which fold inward, causing the arterial wall to pucker, producing a purse-string-like seal closing the puncture site. The case history is that of a 76-year-old female patient who underwent day-case percutaneous diagnostic coronary angiography. A Starclose femoral artery closure device was used to achieve hemostasis with subsequent femoral artery stenosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Remotely Controlled Mixers for Light Microscopy Module (LMM) Colloid Samples

Developed by NASA Glenn Research Center, the LMM aboard the International Space Station (ISS) is enabling multiple biomedical science experiments. Techshot, Inc., has developed a series of colloid specialty cell systems (C-SPECS) for use in the colloid science experiment module on the LMM. These low-volume mixing devices will enable uniform particle density and remotely controlled repetition of LMM colloid experiments. By automating the experiment process, C-SPECS allow colloid samples to be processed more quickly. In addition, C-SPECS will minimize the time the crew will need to spend on colloid experiments as well as eliminate the need for multiple and costly colloid samples, which are expended after a single examination. This high-throughput capability will lead to more efficient and productive use of the LMM. As commercial launch vehicles begin routine visits to the ISS, C-SPECS could become a significant means to process larger quantities of high-value materials for commercial customers.

Kurk, Michael A. (Andy)↗

Recent Advances in 3D Printed Sensors: Materials, Design, and Manufacturing

Sensors are of great importance in different aspects of research and industry. Future sensors will require high-efficient and low-cost manufacturing, as well as high-performance functionality in areas, such as mechanical sensing, biomedical, and optical applications. Recent advances in 3D printing open a new paradigm for sensors fabrication as a precision, customizable, and seamless process. Here, in this article, the state-of-the-art 3D printing methods in sensors manufacturing is reviewed and the performance of the 3D printed sensing materials and devices is summarized. Special attention is paid to emerging multimaterial printing and 4D printing technologies, which will benefit the fabrication of a new generation of structures with multifunctionalities. The content on 3D printed sensors covers piezoelectric sensors, medical, and optical sensing devices. The performance of 3D printed sensors in comparison with the sensors made by traditional manufacturing is also covered. Finally, section 4 provides the viewpoints on the future development of 3D printed sensors.

36 MATERIALS SCIENCE↗

Carbon Nanofiber Nanoelectrode Arrays for Neural Implant Devices

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable smart therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

carbon nanotubes↗

MO-C-BRB-05: Translating NIH funding to a [potential] clinical device in breast cancer radiation therapy

Diagnostic radiology and radiation oncology are arguably two of the most technologically advanced specialties in medicine. The imaging and radiation medicine technologies in clinical use today have been continuously improved through new advances made in the commercial and academic research arenas. This symposium explores the translational path from research through clinical implementation. Dr. Pettigrew will start this discussion by sharing his perspectives as director of the National Institute of Biomedical Imaging and Bioengineering (NIBIB). The NIBIB has focused on promoting research that is technological in nature and has high clinical impact. We are in the age of precision medicine, and the technological innovations and quantitative tools developed by engineers and physicists working with physicians are providing innovative tools that increase precision and improve outcomes in health care. NIBIB funded grants lead to a very high patenting rate (per grant dollar), and these patents have higher citation rates by other patents, suggesting greater clinical impact, as well. Two examples of clinical translation resulting from NIH-funded research will be presented, in radiation therapy and diagnostic imaging. Dr. Yu will describe a stereotactic radiotherapy device developed in his laboratory that is designed for treating breast cancer with the patient in the prone position. It uses 36 rotating Cobalt-60 sources positioned in an annular geometry to focus the radiation beam at the system’s isocenter. The radiation dose is delivered throughout the target volume in the breast by constantly moving the patient in a planned trajectory relative to the fixed isocenter. With this technique, the focal spot dynamically paints the dose distribution throughout the target volume in three dimensions. Dr. Jackson will conclude this symposium by describing the RSNA Quantitative Imaging Biomarkers Alliance (QIBA), which is funded in part by NIBIB and is a synergistic collaboration between medical physicists, radiologists, oncologists, industry representatives, and other stakeholders. The mission of QIBA is to improve the accuracy and practicality of quantitative image-based biomarkers by increasing precision across devices, patients, and time, an essential step in incorporating quantitative imaging biomarkers into radiology practice. Validated quantitative imaging biomarkers are necessary to support precision medicine initiatives, multimodality / multiparametric applications in medicine, treatment planning and response assessment, and radiogenomics applications. Current applications in the QIBA portfolio extend to cancer diagnosis and treatment, pulmonary diseases, and neurological disorders. The overall goal of this symposium is to illustrate the bidirectional exchange between medical research and clinical practice. Revitalizing scientific excellence in clinical medical physics challenges practitioners to identify clinical limitations, which then drive research innovation; research funded by the NIH and other agencies develops technological solutions to these limitations, which are translated to the care environment to ultimately improve clinical practice in radiology and radiation oncology.

60 APPLIED LIFE SCIENCES↗