Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

FACET: The New User Facility at SLAC

FACET (Facility for Advanced Accelerator and Experimental Tests) is a new User Facility at SLAC National Accelerator Laboratory. Its high power electron and positron beams make it a unique facility, ideal for beam-driven Plasma Wakefield Acceleration studies. The first 2 km of the SLAC linac produce 23 GeV, 3.2 nC electron and positron beams with short bunch lengths of 20 {mu}m. A final focusing system can produce beam spots 10 {mu}m wide. User-aided Commissioning took place in summer 2011 and FACET will formally come online in early 2012. We present the User Facility, the current features, planned upgrades and the opportunities for further experiments. Accelerators are our primary tool for discovering the fundamental laws to the universe. Each new frontier we probe requires a new, more powerful method. Accelerators are therefore increasing in size and cost. The future of this field requires new accelerating techniques that can reach the high energies required over shorter distances. New concepts for high gradient acceleration include utilizing the wakes in plasma and dielectric and metallic structures. FACET was built to provide a test bed for novel accelerating concepts with its high charge and highly compressed beams. As a test facility unlike any other, it has also attracted groups interested in beam diagnostic techniques and terahertz studies. The first phase of the construction was completed in May 2011. Beam commissioning began in June and was interleaved with the installation of five experiments. Users were invited to aid with the commissioning for the month of August during which time experimental hardware and software were checked out and some first measurements were taken. FACET is currently in the process of becoming a Department of Energy User Facility for High Energy Physics.

43 PARTICLE ACCELERATORS↗

The photon analysis, delivery, and reduction system at the FERMI-Elettra free electron laser user facility

The FERMI-Elettra free electron laser (FEL) user facility is currently under construction at the Sincrotrone Trieste laboratory in Trieste (Italy). It will cover the wavelength range from 100 to about 5 nm in the fundamental and 3 or 1 nm using the third harmonic. We report the layout of the photon beam diagnostics section, the radiation transport system to the experimental area, and the photon beam distribution system. Due to the peculiar characteristics of the emitted FEL radiation (high peak power, short pulse length, and statistical variation of the emitted intensity and distribution), the realization of the diagnostics system is particularly challenging. The end users are interested in parameters such as the radiation pulse intensity and spectral distribution, as well as in the possibility to attenuate the intensity. In order to accomplish these tasks, a photon analysis, delivery, and reduction system is now under development and construction and is presented here. This system will work on-line producing pulse-resolved information and will let users keep track of the photon beam parameters during the experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developments of fast emittance monitors for ion sources at RCNP

Recently, several developments of low energy beam transport line and its beam diagnostic systems have been performed to improve the injection efficiency of ion beam to azimuthally varying field cyclotron at Research Center for Nuclear Physics, Osaka University. One of those is the fast emittance monitor which can measure within several seconds for the efficient beam development and a Pepper-Pot Emittance Monitor (PPEM) has been developed. The PPEM consists of pepper-pot mask, multichannel plate, fluorescent screen, mirror, and CCD camera. The CCD image is taken via IEEE1394b to a personal computer and analyzed immediately and frequently, and then real time measurement with about 2 Hz has been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Accelerator and Beam Physics of the Muon g-2 Experiment at Fermilab

The physics case of the Muon g-2 Experiment at Fermilab is outstanding and has recently attracted significant attention from its first official results. Although its measurements involve high energy physics methods, such as counting positron production rates with the use of calorimeters and beam diagnostics with tracking detectors, this experiment is strongly bound to accelerator and beam physics. This paper reviews the principles of the experiment and the details necessary to provide a solid ground for the beam-dynamics uncertainties and the corrections of the systematic effects influencing the output of the experiment: a single numerical value, which may unveil new physics.

43 PARTICLE ACCELERATORS↗

Simple Low-Frequency Beam Pickup

Detection of the field induced by a beam outside of the beam pipe can be used as a beam diagnostic. Wires placed in longitudinal slots in the outside wall of the beam pipe can be used as a beam pickup. This has a very small beam-coupling impedance and avoids complications of having a feedthrough. The signal can be reasonably high at low frequencies. We present a field waveform at the outer side of a beam pipe, obtained as a result of calculations and measurements. We calculate the beam-coupling impedance due to a long longitudinal slot in the resistive wall and the signal induced in a wire placed in such a slot and shielded by a thin screen from the beam. These results should be relevant for impedance calculations of the slot in an antechamber and for slots in the PEP-II distributed ion pump screens. The design of the low-frequency beam position monitor is very simple. It can be used in storage rings, synchrotron light sources, and free electron lasers, like LINAC coherent light source.

43 PARTICLE ACCELERATORS↗

BEAM INSTRUMENTATION FOR HIGH POWER HADRON BEAMS

This presentation will describe developments in the beam diagnostics which support the understanding and operation of high power hadron accelerators. These include the measurement of large dynamic range transverse and longitudinal beam profiles, beam loss detection, and non-interceptive diagnostics.

Aleksandrov, Alexander V↗

Remote Synchrotron Light Instrumentation Using Optical Fibers

By coupling the emitted synchrotron light into an optical fiber, it is possible to transmit the signal at substantial distances from the light port, without the need to use expensive beamlines. This would be especially beneficial in all those cases when the synchrotron is situated in areas not easily access because of their location, or due to high radiation levels. Furthermore, the fiber output can be easily switched, or even shared, between different diagnostic instruments. We present the latest results on the coupling and dispersion measurements performed at the Advanced Light Source in Berkeley. In several cases, coupling synchrotron light into optical fibers can substantially facilitate the use of beam diagnostic instrumentation that measures longitudinal beam properties by detecting synchrotron radiation. It has been discussed in with some detail, how fiberoptics can bring the light at relatively large distances from the accelerator, where a variety of devices can be used to measure beam properties and parameters. Light carried on a fiber can be easily switched between instruments so that each one of them has 100% of the photons available, rather than just a fraction, when simultaneous measurements are not indispensable. From a more general point of view, once synchrotron light is coupled into the fiber, the vast array of techniques and optoelectronic devices, developed by the telecommunication industry becomes available. In this paper we present the results of our experiments at the Advanced Light Source, where we tried to assess the challenges and limitations of the coupling process and determine what level of efficiency one can typically expect to achieve.

43 PARTICLE ACCELERATORS↗

Effects of delta ray electrons on measurement uncertainties of harp system

A harp system, which is a multi-wire beam profile monitoring (MWPM) system, is planned upstream of the spallation target to make in situ calibration of beam current density configuration on the target along with beam imaging from luminescent coating on the beam entrance window at the Second Target Station (STS) of the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). This beam interception-based beam diagnostics system on the target will be used to ensure that the maximum beam loads on the target are within the design range during neutron production. Current design of the harp consists of three layers of measurement wires each of which is sandwiched between voltage biasing wire planes. The signal obtained from each measurement wire layer is disturbed by secondary electrons (SE) and delta rays produced by beam-matter interactions in neighboring wires and ionization of residual gases in accelerator vacuum. While the backgrounds from SE can be suppressed by voltage biasing, the delta-ray electrons with kinetic energies above keV ranges overcome the electric potential bias. In this paper, we study the effects of delta-rays on the measurement uncertainties of MWPM using the particle transport simulation code FLUKA. Furthermore, the cases where the harp system is installed in the proximity of a large delta ray sources such as proton beam window or in the core vessel filled with sub-atmospheric gas have been studied.

Lee, Yong Joong↗

Diagnostics of ion beam generated from a Mather type plasma focus device

Diagnostics of ion beam emission from a 3 kJ Mather-type plasma focus device have been performed for deuterium discharge at low pressure regime. Deuterium plasma focus was found to be optimum at pressure of 0.2 mbar. The energy spectrum and total number of ions per shot from the pulsed ion beam are determined by using biased ion collectors, Faraday cup, and solid state nuclear track detector CR-39. Average energy of the ion beam obtained is about 60 keV. Total number of the ions has been determined to be in the order of 10{sup 11} per shot. Solid state nuclear track detectors (SSNTD) CR39 are employed to measure the particles at all angular direction from end on (0°) to side on (90°). Particle tracks are registered by SSNTD at 30° to 90°, except the one at the end-on 0°.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical characterization of the on-target OMEGA focal spot at high energy using the full-beam in-tank diagnostic

The full-beam in-tank (FBIT) diagnostic has been deployed to directly measure the target-plane beam fluence profile, when operated at high energy, of the OMEGA Laser System at the University of Rochester’s Laboratory for Laser Energetics. This article presents the results of early measurements taken with this diagnostic and discusses an improvement that has overcome performance limitations discovered during the initial testing. The diagnostic gives new insight into the ability of the OMEGA Laser System to provide uniform fluence profiles that are consistent across all 60 beams in the laser. Overall, the ultimate goal of the FBIT diagnostic is to allow accurate assessment of the fluence uniformity on a spherical target in 60-beam implosion experiments

47 OTHER INSTRUMENTATION↗

A novel nondestructive diagnostic method for mega-electron-volt ultrafast electron diffraction

Abstract A real-time, nondestructive, Bragg-diffracted electron beam energy, energy-spread and spatial-pointing jitter monitor is experimentally verified by encoding the electron beam energy and spatial-pointing jitter information into the mega-electron-volt ultrafast electron diffraction pattern. The shot-to-shot fluctuation of the diffraction pattern is then decomposed to two basic modes, i.e., the distance between the Bragg peaks as well as its variation (radial mode) and the overall lateral shift of the whole pattern (drift mode). Since these two modes are completely decoupled, the Bragg-diffraction method can simultaneously measure the shot-to-shot energy fluctuation from the radial mode with 2·10 −4 precision and spatial-pointing jitter from the drift mode having wide measurement span covering energy jitter range from 10 −4 to 10 −1 . The key advantage of this method is that it allows us to extract the electron beam energy spread concurrently with the ongoing experiment and enables online optimization of the electron beam especially for future high charge single-shot ultrafast electron diffraction (UED) and ultrafast electron microscopy (UEM) experiments. Furthermore, real-time energy measurement enables the filtering process to remove off-energy shots, improving the resolution of time-resolved UED. As a result, this method can be applied to the entire UED user community, beyond the traditional electron beam diagnostics of accelerators used by accelerator physicists.

43 PARTICLE ACCELERATORS↗

Performance Test of the Next Generation X-Ray Beam Position Monitor System for The APS Upgrade

The Advanced Photon Source is developing its next major upgrade (APS-U) based on the multi-bend achromat lattice. Improved beam stability is critical for the upgrade and will require keeping short-time beam angle change below 0.25 µrad and long-term angle drift below 0.6 µrad. A reliable white x-ray beam diagnostic system in the front end will be a key part of the planned beam stabilization system. This system includes an x-ray beam position monitor (XBPM) based on x-ray fluorescence (XRF) from two specially designed GlidCop A-15 absorbers, a second XBPM using XRF photons from the Exit Mask, and two white beam intensity monitors using XRF from the photon shutter and Compton-scattered photons from the front end beryllium window or a retractable diamond film in windowless front ends. We present orbit stability data for the first XBPM used in the feedback control during user operations, as well as test data from the second XBPM and the intensity monitors. They demonstrate that the XBPM system meets APS-U beam stability requirements.

Yang, B.↗

Synchronization and Jitter Studies of a Titanium-Sapphire Laser at the A0 Photoinjector

A new titanium-sapphire laser has recently been installed at the A0 photoinjector for use in ongoing beam generation and ultra-fast beam diagnostics experiments. Where the system is used as the photoinjector drive laser, jitter and drift in t he laser pulse time of arrival with respect to the low-level RF master oscillator and other beam components are known to degrade beam performance. These same fluctuations can also impact the temporal resolution of laser-based diagnostics. To resolve this, we present the results of some beam-based timing experiments as well as current progress on a synchronization feedback loop being adapted to the new laser system.

43 PARTICLE ACCELERATORS↗

Present Status and First Results of the Final Focus Beam Line at the KEK Accelerator Test Facility

ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

43 PARTICLE ACCELERATORS↗

Tunable Q-Factor Gas-Filled RF Cavity

Fermilab is the main institution to produce the most powerful and wide-spectrum neutrino beam. From that respective, a radiation robust beam diagnostic system is a critical element in order to maintain the quality of the neutrino beam. Within this context, a novel radiation-resistive beam profile monitor based on a gas-filled RF cavity has been proposed. The goal of this measurement is to study a tunable Q-factor RF cavity to determine the accuracy of the RF signal as a function of the quality factor. Specifically, the measurement error of the Q-factor in the RF calibration is investigated. Then, the RF system will be improved to minimize signal error.

43 PARTICLE ACCELERATORS↗

Present Status And First Results of the Final Focus Beam Line at the KEK Accelerator Test Facility

ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

43 PARTICLE ACCELERATORS↗